HomeMy WebLinkAboutTANK SPECS - 7-14-20Quality Steel Corporation AG/UG Propane Tanks
1450 wg. AND UP
APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS
WATER
CAPACITY
DIAMETER
(OD)
HEAD
TYPE
OVERALL
LENGTH
OVERALL
HEIGHT
LEG*
WIDTH
LEG**
SPACING
WEIGHT
(Ibs.)
**QUANTITY
FULL LOAD POt STACK
*120 wg.
24"
Ellip.
51-8"
3'
1'-11/2"
2'-101/2"260
or 3'-11"
108196
16112
*250 wg.
30"
Hemi.
7'-10"
31-8"
1'-5"
4'-11"
480
54
9
*320 wg.
1
30"
Hemi.
9'-7"
3'-8"
1'-5"
5'
620
45
9
500 wg.
371/2"
Hemi.
10'
4'-2"
1'-8"
5'
950
37130
8 1 6
1000 wg.
41"
Hemi.
16'
4=S"
11-8"
10'-1"
11800
17 15
615
1450 wg.
461/2"
Ellip.
17'-4"
4'-11"1'-9"
11'-7"
2,650
12
4
1990 wg.
461/2"
Ellip.
23'-11"
4'-11"
1'-9°
16'
3,520
8
4
gn►enstans and specifications shown are appy d mate. Individual vessels may vary.
Leg spacing +/- 2'. Leg widths and spacing may vary based an mfg. location. Check with your salesperson for detaits. 120,250, 320 wg. standard tanks
- no holes In kegs (one center hole an requestl. SW and 2000 wg. standard tanks - 2 holes 16" an center. 1450 wg. and up as shown above.
'• Full load and stack quantities vary by shlpping location. Check with your salesperson for details.
General Sceciflcations
- Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1.
Complies with NFPA 58.
- Rated at 250 prig from -20" F to 125" F. All vessels registered with National Board.
- Two service options available:
Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish
or !'squid applied epoxy primer coat followed by urethane top coat, supplied with composite
AG/UG dome.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome.
- All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated lute 30, 2015
PROPANE CONSTRUCTION NO
, TES
1. All pipe and fittings above round and d
SCH..40 Galvanized9 Inside building shall be
ASTM A120 or AGA approved.corrugated
stainless steel •(C.S.S.T.) pipe.
2. All polypipe and f7ttin9s shalt be ASTM D25 f 3 or ASTM D25
and shalt be b q ed -outside u 17
nderground at a depth of 18" with
wa
ming tape and tracer wire.
3. All pipe and meter locations are approximate and subject
change.- t to
.4. All polypipe shaft be joined by heat fusion ora
couptin s. approved mechanical.
. 5
coupling
. Alt galvanized pipe shall be threaded.
B. A. pipe shag be pressure tested to 20 PSI for a period of 24
hours.