Loading...
HomeMy WebLinkAboutREVIEWED, APPROVED Product approvalsAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: Permit Number: L `L 1.; E f, Planning and Development Services Building and Code Regulation Division Commercial 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR: Metal Re -Roof PROPOSED IMPROVEMENT LOCATION: . Address: 25 Grande Vista Way Property Tax ID #: 426-500-0520-000-3 Site Plan Name: Anastasia McNamara Project Name: McNamara Residential x Lot No.25 Block No. 1 DETAILED DESCRIPTION OF WORK: I 26 ga. 5-V Metal Re -Roof New Electrical Meter Second Electrical Meter CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: _Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Electric _ Plumbing _ Sprinklers Total Sq. Ft of Construction: Cost of Construction: $ 13,917.00 _ Generator Windows/Doors Roof 72( Sq. Ft. of First Floor: Utilities: —Sewer —Septic Building Height: Pitch OWNER/LESSEE: CONTRACTOR: Name Anastasia McNamara Jesus Vasquez, Jr. Name: q Address:25 Grande Vista Way Company:All American Roofing & Coating of FL City: Port Saint Lucie State: _ Zip Code: 34952 Fax: j Phone No. 772-807-7571 ( Address:340 SE Seville St. City: Stuart State: FL Zip Code: 34994 Fax: 772-781-4408 Phone No772-781-4410 E-Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mailoffice@allamericanroofer.com State or County License CCC1329384 If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: X Not Applicable MORTGAGE COMPANY: X Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: X Not Applicable BONDING COMPANY: X Not Applicable Name: Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recoLding your NOfice of Commencement. "of/License Signature of Owner/ Lessee/Contractor as Agent for Owner Holder STATE OF FLORIDA COUNTY OF P/ aXijV1 CCU NTY OF Wa^ 1/1 Sworn to (or affirmed) and subscribed before me of Sw rn to (or affirmed) and subscribed before me of Physical Presence or Online Notarization Physical Presence or Online Notarization " this day of , 2020 by Q_ day off 2020 by moo YN yiamaaict x Name of person making statement. o M1 Z e of person making statement. J� Personally Known OR Produced Identification a O A W A onally Known OR Produced Identification C . w Z R E wo Type of Identification I w .o � of Identification Produced AIR It w a uced/ 1 V Z •AlfAi y0 v • O'. ignature of Nrotary Public State of Florida of Notary Public- State of Florida)v Commission No. (Seal) C fV No. (Seal) J WV`� y�=yy. ":�N. SSp, mission REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. t o- . n � . . Roof g & SE Seville St. Stuart_ FL -4119d � ubnil€tied _o: Aaastas;?a McNamara 15 GranQe:TtSta �ai rM1' Port Saint Lucie, i L 34 5v stacie23@corricast.net t^r_1 b'0!-1J 11 T L i i':ieriCat. Rooi'in�' . Coating ofFlorida, Inc. submits the en, ed p'i'.'nlises as follovis. We -;ill provide all ia? L SCOPE. OF -: A ,-ner?can Roofing will remove and dispose of existing sl.i '; R will inspect existing p?ivNvood sheathing and re -hail accol -_-ti_Alam will Replace Lip to three. (3) sheets 5/8 CDX plywood if i - f R -will histali an ASTIVI modified self -adhered metal roof u :i st._i. 2,6aa. ,aivalil€Tie aGCeSSvey 3llvtasS. -s--J l install new . vents and plumbing, flashings at extstinc, -. ""'.v' 'ns"all a 2bga. Galvalume 5-V Cri€nLpieta' Mill Fill lac Scretivs. -. „'iF tci procure the permit and remove all roofing debris upon c'at' t- oi'IiiTia€iSi�ip WaiTanty and any Manufacturer's td ai p a,,'nleitt. Jot; ',arne: f fasiasia 111.--_ ,..<_.<sa=-. toposal for your cons i `se "atioll to' ip- G�';r iS,aCe4: 1- .nt_ h i oil ,. _ a C a s IU: the e io _ l e ri roof do-vn to plywood sheatll -i`. to Coale. ,ed. I`d/�. rlayinent direct to plyt+.onyd deck. anons. n oo,€ii; System. fasteled to Go iFSin- 2'vyi' `a'to pletion. r es will be tortharde d upon r,ece€pt o ti=la " e ::'all furnish labor and materials for the surn of:......<<<, Discourita rates: i 1 °.a y Work done beyond the scope of this contract Iv ll he in oiled additionally and separately, (r" r'ease See Food & Labor Addenduin & Job (,h eii iO1t=) INITIAL: 14A 2) Please note that any damages determined to be the result of';?"d er trades, or incurred after roof final. will be at an ditto- n a r r s c L' �d�itrJ,la: an.. separate charge to cont_actoc'iiomeotvneF'. ��fi � � I } INto verbal promises inade by any representative of this com)ary are binding unless contained in the s This Proposal becomes a binding contract upon execution by CONTRACTOR. All American Roofing & Coating of Florida, Eric. _. Work -will be scheduled once this Contract is signed, a Notici sD p _ !• OP Tile 0vv7NTIR shall i?lame a £' mc—r ess ?aynient o47' 'iv% ; i th,_ Lipor, conlpletion of Work under this Contract, a final payrne_ EXCLUSIONS. This Contract sped€ically excludes the io l a x E RE FOR: Lu«ers. downspouts and roof mounted objects%including J" l C'L GC' C A-i t" rat is filed, and a 3 % deposit iv received -rice at the n ilc of con; ?etio' v - So o of the contract price is due immediately. a and the Contractor DISCLAIMS ALL z_rAABI L. _Y not limited to Solar `anels, JOSEPH E. SMITH, CLERK OF THE CIRCUIT COURT — SAINT LUCIE COUNTY FILE # 4735573 OR BOOK 4453 PAGE 1508, Recorded 07/29/2020 12:44:45 PM Permit No. State of Florida, County of St. I.ucie NOTICE. OF COMM ENCEIMENT Property "fax 11) No, 3426-500-0520-000-3 The Undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. Legal Description of property and address if available St Lucie Gardens Lot 25 General description of improvements Meal Re -Roof tlwnerltrqcee Anastasia McNamara Address 25 Grande Vista Way Interest in property: owner Fee Simple Title holder (if other than owner) Address Contractor �1 A t V �L Phone—#t� t� ` �) f �i �--1 Zk "1tgtD c��j�YlYtc D �p Fax # 1� Z— t j —Li Surety Phone» Address G}5t (� (_� ��{� �, � 7� Fax Amount of Bond Lender Phone» Address Fax» Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13 (a) 7.. Florida Statues: Nance Phone» Address Fax In addition to himself, owner designates of Phone Fax # to receive a copy of the Lienor's Notice as provided in Section 713.13 (1) (b), Florida Statutes. Expiration date of notice of commencement is one year from the date of recording unless a different date is specified. WARNING TO OWNER: ANY PAYMENTS MADE SY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMNSENCEMEN7 ARE CONSi[)EREI? IMPROPER. C H.'!3.!?. F.S.. AND CAi,: RESULT IN YOUR PAYING TWICE. FOR !MPRO'VEMEN'I'S ' 1-0 YOUR PROPERTY. A NOTICE OF COMMENCEMENT NfUST BE RECORDED AND POSTED ON THE.IOB SITE BEFORE THE FIRST INSPECTION. iF YOU NNTEIMD TO OBTAIN FINANCING. CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDiti(; YMC R '\"OTtC'F. OF t tiMMFN'CMFUT. G OwneriT,essee, or Owner's or t,essee Autt rized Officer/nirectar%ParSncr M1l anaKer Sign atu rc Anastasia McNamara Signatory's Titie/Office State of Florida, County of V\ Acknowledged before me this day of _ 20w, b} Anastasia McNamara wii is per or" lly known tome or who has produced yes° °Ykr, r, as identification. o-ca1�D�nctll�y�ino�/� 'natur of ; y �peor Print NAme of N'otary (Seal) Title: Notary Public Commission Number i�01 "oe . JENNIFER LEE COUT, NHC �'. .Netar ?uolic -State of Flnrda Y :c Tit; :•c Cor^.rr.issior r GG 362000 o`c r'�.�. ' My Cor,.rn, E,zwes Aug E. 2023 3onded through Nat+oral Notary Assn. I tll Kt li}t.I. EI IlI I!fi\ixt(1 ♦IE IHII t\1)t I)Itl<I:t-1 tt 11 tll l\(It'1:1 I.KF (IK!)f)K "Ti �_u _ - --- - --� �_--�� III I'll \\n V i t \! I) Iit_CilRil _ll tIK E-tl h.111\ _ - . III': ntt!( tilft �l.!t'Irt I\Il 'Atli (111 M I HU t: IT t'IIIIt I: IRL1, Ef} I \},. lrl 6df'L 8LtiLLL ti660LLlOLLly�la�s/say��a�{Sa6ew1t6aoa�sednnrlunjj:sd��y dO B t 9£E7 a Wo r LZ ZL r9 A l C 6LLL sve£ oz lo04? oL Ndl D fit (b8£xZLS}6dIL-2LVi/L V660LL OZOZ/L/8 8/7/2020 Florida Building Code Online G:19W_ .. BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCiS Site Map Links Search d Product Approval op- USER:�Public User Product Approval Menu > ProduCL or Application Search > Application List Search Criteria Refine Search Code Version 2017 FL# 17022.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - Applications FL# Type Manufacturer Validated Status gy FL17022- Revision Extreme Metal Fabricators, LLC Zachary R. Approved R7 FL#: FL17022.1 Priest, P.E. History. Model: 1 - "5V Crimp" (R6) (813) 480- Description: 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel 3421 mechanically attached to 15/32" plywood or Wood Deck with fasteners Category: Roofing Subcategory: Metal Roofing "Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail, if you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275(i ). Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The eria:ls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts- 1 ._s:-. Greet Card Safe https://ww�v.floridabuilding.org/pr/pr_app_lst.aspx 1/1 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws, 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 1 METHOD 4� DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF i ROW SPACING 16" o.c. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) ( 12" O.C. 12" O.C. 12" O.C. 12, O.C. FASTENER SIZE ( #9 #10 #10 j #10 Reference Data: ARCHITECTURAL TESTING, INC. TST 1D#: 1527 UL 580-06 & 1897-041 Test Report C05893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-12 *Design pressure margin of safety 2:1 ..,etitfrftrw.. _-_ Locke Bowden, P.E. does not have, not will acquire a financial int n 81 cq 8� facturing or distributing products under this evaluation. " d Locke Bowden, P.E. is not owned, operated, or controlled by at y coaiparN;jrr4iWfa4turer, or Qistributing products under this report. t. FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 61h ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. Panel Overlap 75i32" or greater Plywood. or Wood plank 12" t4 — Panel Profile Nominal12" _ Nominal12" O.C. O.C. Fasten #9 x 1-1/2" Min. or #10 x 1-1/2" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Refer to Table "A" for Spacing Along Panel Length Deck-15/32" or greater Plywood, or -Wood plank 8/7/2020 Florida Building Code Online dt7 dam,; , 1 BCIS Home Loa In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search m j'Product Approval Clio, HE \6 - USER: Public User ;_ \J1 Product Approval Menu > Product or Apphcation Search > Application List Search Criteria Refine Search Code Version 2017 FL# 16048.1 Application Type ALL Product Manufacturer ALL Category ALL Subcategory ALL Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model, Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant ALL Design Pressure ALL Other ALL Search Results - Applications FL# Type Manufacturer Validated By Status FL16048-R6 Revision ! Tri-Built Materials Group, LLC John W. Knezevich, PE Approved History FL#: FL16048.1 (954) 772-6224 Model: TRI-BUILT Roof Underlayments Description: Self -adhering, modified bitumen roof underlayments Category: Roofing Subcategory: Underlayments *Approved by DBPR. Approvals by DBPP, shall be reviewed and ratified by the POC and/or the Commission if necessary. Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emads provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: enr P11— 7 Y1. eC R_t ., - C;rud'. Card Safe https://ww-w.floridabuiiding.org/pr/pr_app_lst.aspx 1 /1 • EVALUATION REPORT TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800)516-1485 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report A42960.10.12-R6 FL16048-R6 Date of Issuance: 10/25/2012 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle, ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59156, Florida DCA ANE1983 `t- 57'`' �•lpt The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/25/2017. This does not serve as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6"' Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations J Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2A / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 3. REFERENCES: gniAy Examination Reference Date ERD (TST6049) Physical Properties S40540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties S40540.11.13 11/19/2013 ERD (TST6049) Physical Properties S40540.03.14 03/26/2014 ERD (TST6049) Physical Properties S44870.04.14-2 04/02/2014 ERD (TST6049) Physical Properties 544870.04.14-3 04/02/2014 ERD (TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD (TST6049) Physical Properties S44870.04A4-4 04/10/2014 ERD (TST6049) Physical Properties S43530.02.14-1-R1 05/14/2014 ERD (TST6049) Physical Properties 543530.05.14 05/28/2014 ERD (TST6049) Physical Properties S40540.10.14 10/31/2014 ERD (TST6049) Physical Properties SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD (TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL, LLC. (QUA9625) Quality Control Multiple -Listing R16814 12/ 10/2015 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 2 of 6 r Ml 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Asphalt ( Wood Shakes Underlayment Shingles I Nail -On Tile Foam -On Tile Metal Slate &Shingles No No No Yes Yes Tri-Built Sand-R SA Shingle Yes Underlayment Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes Underlayment ' See 5.5.1 Tri-Built Smooth HT S/A Yes No No Yes Yes Yes Underlayment I 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS) Adhesive Florida Product Approval Underlayments ICP Adhesives Polyset" AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TileBond'" FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: Y Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: :- Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, Appendix J. Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6 Certificate of Authorization #i9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 3 of 6 ERD 5.6.3 Bond to Mechanically Attached Base Layer: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: i> ASTM D226, Type I or 11 felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on the systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table lA or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #3 Maximum Design Pressure = -150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. #4 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6T' EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 4 of 6 ERD 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Maximum Underlayment Tile Profile Staging Method Slope Flat Max. 10-tile stack 6:12 Max. 10-tile stack 5:12 Lugged Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope as shown below) q Tri-Built S/A HT TU 1 Underlayment Lugged w M Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 5 of 6 6. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlayment Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment: 63.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Tri-Built S/A HT TU Underlayment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for the staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certificate of Authorization #9503 6Tw EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 6 of 6