HomeMy WebLinkAboutHealth Dept Approval reportSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Jaar Enterprizes, LLC AGENT: Dave Fowler (Culpepper & Terpening, Inc) PROPERTY ADDRESS: 5809 Spruce Dr Fort Pierce, FL 34982 LOT: 36 BLOCK: 77 APPLICATION # : AP1383621 PERMIT #:56 -SF -1902579 DOCUMENT #: F11465912 DATE PAID" 1 /16/2018 FEE PAID -515.00 RECEIPT #:56 -PID -3804215 SUBDIVISION: Indian River Estates ID#: 3402-610-0221-000-1 DATE: 05/20/2020 CONSTRUCTION [ APPROVED DISAPPROVED CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. FINAL SYSTEM TANK INSTALLATION ] : n� �� St. Lucie CHD SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polypropylene editions which may not be used) [ ] [28] DITCHES 15 FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [04] MULTI-CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL -68 [ ] [31] IRRIGATION WELLS 50 FT [ ] [06] LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 26 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 8 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 5 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 509.4 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 7.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 08/11/2020 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 6.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [47] CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [22] FILL AMOUNT [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [23] FILL TEXTURE [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. / A� � O 1 St. Lucie CHD DATE: 05/20/2020 CONSTRUCTION [ APPROVED DISAPPROVED .ti E vironmental Specialist II Brian J Ingram (ENVIRONMENTALHEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ] : n� �� St. Lucie CHD DATE: 08/11/2020 Environmental Specialist I Hunter A Collier (Florida Department of Hea (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1383627 EID1902579 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1383627 PERMIT #:56 -SF -1902579 DOCUMENT #:F11465912 DATE PAID :11 /16/2018 FEE PAID -515.00 RECEIPT #:56 -PID -3804215 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and 4x6+3x7 long BED DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final nspection for filled system and final site grading. Final system approved. Emailed to contractor and building department. DH 9016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 69E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 NP1363627 EID1902579