Loading...
HomeMy WebLinkAboutProject InformationLoad Short Form Job Date: 1128/20 Entire House By: MECHANICAL A/C Plan: BRIDGEPORT GR 1373 N. KILLIAN DR., LAKE PARK, FL 33403 EnnA M AECHANICALAC.COM Web: LIG-CAC18ma81 Project Information For: BRIDGEPORT_GR_CUST 2020_WHITAKER, PORT ST LUCIE PROPERTIES 5004 PINETREE DR, FT. PIERCE, FL 34982 Htg Clg Infiltration Outside db(°F) 41 91 Method Simplified Inside db (°F) 70 74 Construction quality Semi -loose Design TD (°F) 29 17 Fireplaces Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 2 56 HEATING EQUIPMENT Make Franklin Trade FRANKLIN Model GSZ160361B• AHRI ref 201667770 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacitybalance point= 36 OF 9.5 HSPF 35000 Btu h @ 47° F 27 OF 1200 cfm 0.041 cm/Btuh 0.50 in H2O Backup: Goodman Mfg. FRANKLIN HKSC10XC Input = 9 kW. Cutout = 29459 Btuh. 100 AFUE COOLING EQUIPMENT Make Franklin Trade FRANKLIN Cond GSZ160361B' Coil ASPT37C14A' AHRI ref 201667770 Efficiency 13.0 EER, 16 SEER Sensible cooling 28386 Btuh Latent cooling 5814 Btuh Total cooling 34200 Btuh Actual air flow 1200 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 ROOM NAME Area (ft') Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MB 139 1399 1331 57 58 MBR 268 2932 2323 119 101 KITCHEN 150 274 1971 11 86 DINING 229 3590 5314 146 231 BDRM 3 171 2132 1752 87 76 BTH2 66 963 623 39 27 FAMILY 239 4927 4643 201 202 H 34 0 0 0 0 BDRM 2 155 2435 1660 99 72 GARAGE 420 0 0 0 0 MC2 53 1076 447 44 19 MCDE 40 1759 742 72 32 LR 278 2128 nnen 2292 .Ienn 87 enn 100 cn JV GJOO IJJJ ILG VJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t wrt. 9�� � Right -Suite® Universal 201919.0.15 RSU08764 ..: w takerlBRIDGEPORT_GR_CUST 2020 WHITAKER.mp Cale=10J8 Front Doorfaces: N 2020Jan-28 21:04:41 Page 1 LAUN MBRS 44 33 OU4 2349 1104 1803 LI 96 4w 78 Entire House 2352 29459 27628 1200 1200 Other equip loads 0 0 Equip. @ 1.00 RSM 27628 Latent coaling 5711 1 I 1200 1 1200 OTALS 2352 29459 33339 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wWghtsoft• 202(Wan-2821:04:41 ....v........,_r.,.... Right -Suite® U nlversel 201919.0.15 RSU08764 ,Page2 ..: WhitakeMRIDGEPORT_GR CUST_2020 WHITAKER.rup Coto =MA Front Door faces: N Project Summary ry Date: 1128120 Entire House By: MECHANICAL A/C Plan: BRIDGEPORT GR 1373 N. KILLIAN DR., LAKE PARK, FL 33403 Email: WN XIV ECHANICALAC.COM Web: U6 CAC1816081 For: BRIDGEPORT GR CUST 2020 WHITAKER, PORT ST LUCIE PROPERTIES 5004 PINETREE DR, FT. PIERCE, FL 34982 Notes: Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 91 OF Inside db 70 OF Inside db 74 OF Design TO 29 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 56 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23703 Btuh Structure 20732 Btuh Ducts 5756 Btuh Ducts 6896 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29459 Btuh Use manufacturer's data y Rate/swing multiplier Equipment load 1.00 27628 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -loose Fireplaces 0 Structure 4249 Btuh Ducts 1461 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Pre (ft� 1933 1933 Equipment latent load 5711 Btuh Volume (ft3) 17632 17632 Air changes/hour 0.59 0.31 Equipment Total Load (Sen+Lat) 33339 Btuh Equiv. AVF (cfm) 173 91 Req. total Capacity at 0.83 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Franklin Make Franklin Trade FRANKLIN Trade FRANKLIN Model GSZ160361B• Cond GSZ160361B' AHRI ref 201667770 Coil ASPT37C14A` AHRI ref 201667770 Efficiency 9.5 HSPF Efficiency 13.0 EER, 16 SEER Heating Input Sensible cooling 28386 Btuh Heating output 35000 Btuh@47"F Latent cooling 5814 Btuh Temperature rise 27 OF Total cooling 34200 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.043 dmBtuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacitybalance point= 36 OF Backup: Goodman Mfg. FRANKLIN HKSCIOXC Input = 9 kW, Output = 29459 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fi&-wrrghtsof — 202Wan-2821:04:41 �[�+'• M—.� Right -Suite® Universal 201919.0.15 RSU08764 Paget ACCk ..: WhifakeZZDGEPORT GR CUST_2020_MITAKER.Min Cale -MJS Front Door faces: N Manual S Compliance Report Date: vzaiso Entire House By: MECHANICAL A/C Plan: BRIDGEPORT GR 1373 N. KILLIAN DR., LAKE PARK, FL 33403 Email: MM MECHANICALACcOM Web: LIG- CAC1816081 For: BRIDGEPORT_GR_CUST_2020_WHITAKER, PORT ST LUCIE PROPERTIES 5004 PINETREE DR, FT. PIERCE, FL 34982 Design Conditions Outdoor design DB: 91.2"F Sensible gain: 27628 Btuh Outdoor design WB: 77.1°F Latent gain: 5711 Btuh Indoor design DB: 74.0°F Total gain: 33339 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Franklin Actual airflow: 1200 cfm Sensible capacity: 28386 Btuh Latent capacity: 5814 Btuh Total capacity: 34200 Btuh Design Conditions Outdoor design DB: 41.0°F Indoor design DB: 70.0°F Model: GSZ160361B'+ASPT37C74A' 103% of load 102a/u of load 103a/a of load SHR: 83% Heat loss: 29459 Btuh Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer. Franklin Model: GSZ160361B•+ASPT37C14A` Actual airflow: 1200 cfm Output capacity: 35000 Btuh 119'/o of load Supplemental heat required: 0 Btuh Backup equipment type: Elec strip Manufacturer: Goodman Mfg. Model: HKSC10XC Actual airflow: 1200 cfm Output capacity: 8.6 kW 100% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. Entering coil DB: 75.5°F Entering coil WB: 62.5°F Entering coil DB: 69.4°F Capacity balance: 36 OF Economic balance: -99 OF -t* wrtghtsoft' 2o204an 28 21:04:42 ^y ...,.. �r,�.., Right-Salte®Unlveraal 281818.8.15 Rsuo97&i Page �� ..: mlmker%BRIDGEPORT GiZpUST 2020 WHITAKER.mp Cale =MJ8 Front Door faces: N GENERAL NOTES To the best of my knowledge these plans and specs do comply With all applicable codes & 2017 Florido Building Codc,Mechanical. Energy calculations done using Energy Gauge- FloRes2010 & Right-JR Right-JO is the automated Version of the 8th edition of the AMA Manual J. RighL--lO computes the sizes of heating and cooling design loads and is thus used for sizing residential HVAC equipment Duct Design done using Right—D¢ Right—D# is the microcomputer Version of the second edition of the AOCA Manual D far Residential duct design. These plans supersede and void all previous plans and specfications. Duct & grille locations may change due to owner's request or structural limitations. ALL CFM'S ARE APPROXIMATE, ACTUAL CFM VARIES UPON CURRENT STATIC PRESSURE OF HVAC SYS Job #: Performed for: BRIDGEPORT GR_CUST 2020 WHITAKER 5004PINETREE DR FT. PIERCE, FL 34982 HVAC NOTES EQUIPMENT SCHEDULE CONDENSER— GSZ16036 FRANKLIN MAX FUSE-30 M,C.A.-16.9 VOLT-23B AIR HANDLER— ASPT37014A NOMINAL CFN-12DO NI.C,A-4.5 VOLT-230 MOTOR SPEED— TAP 3 HEAT-10KW M.C.A— 54 MAX FUSE— 60 TOTAL BTU— 34,200 SEER RATING— 16 HSPF— 9.5 AHRI REF#— 201667770 THERMOSTAT— HONEYWELL T6 REF LINES— 3/4 / 3/8 DEFAIL COMPLIES WITH FLOC MECH , 301,12 r O7C ORRO.I�R Qhrr E1pp�Tp 4 I�Y,II( lOCalq BY 1/ETN 51R1 6' 01K EIFLIwGi. r ` U u MM use / I waH Noah -ORE-nEs• I Fmmotwr PRhCt *E E KYER WEFOX MECHANICAL A/C 1373 N. KILLIAN DR. LAKE PARK, FL 33403 Scale: 1 : 83 Page 1 RightSulteO U nivemal 2019 19.0.15 RSU08764 2020-Jan-28 21:05:05 LIC- CAC1816081 V MN.MECHANICALAC.COM Certificate of Product Ratings AHRI Certified Reference Number: 201667770 Date: 01-28-2020 Model Status: Active Old AHRI Reference Number: 8331282 AHRI Type: HRCU-A-CS Series: GSZ16 Outdoor Unit Brand Name: FRANKLIN Outdoor Unit Model Number (Condenser or Single Package) : GSZ1603618' Indoor Unit Model Number (Evaporator and/or Alr Handler) : ASPT37C14A' The manufacturer of this FRANKLIN product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, Independent, third parry testing: Cooling Capacity (A2) -'Single or High Stage (95F), btuh : 34200 SEER:1&00 EER (A2) - Single or HlghStage.(95F).:-13.00------- Heating Capacity (H12) \Single o_ r� High S i ge (4' 7P) : 35000 O HSPF(Region IMF9 50 E-0 / DER F EV 1:IiI lAJ l'tifOl°SUU �IuJ IJ if��lSOIJ �o 0IUD J/ t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced'Production Stopped' Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratincis that are accompanied by WAS Indicate an Involuntary re -rate. The new published ratno is shown alone with the orevious fi.e, WAS) reline. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any torn or manner or by any means, except for the user's Individual, AM personal and confidential reference. AIR-CONUmONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information forthe model cited on this certificate can be verified at www.shrldirectory.org, click on `Verify Certificate- link we make life better' and enter the AHRI Certified Reference Number and the date an which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed at bottom right ©2020AIr-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132247368398203310