Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product approvals
Florida Building Code Online Page 1 of 3 9. tt a.1. BCIS Home Log In User Registration j Hot Topic Submit Surcharge Stats&Facts t Publications Contact Us i BCIS Site Map Links Search d.. Roflvt3 'ProductApproval P r USER:Public User ,t Product Apprpval Menu>Product or Application Search>Application List>Application Detail FL# FL9806-R6 Application Type Revision Code Version 2017 Application Status Approved i *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer NCFI Div.of Barnhardt Mfg. Co. Address/Phone/Email PO Bois 1528 Mount Airy,NC 27030 (800)346-8229 jason.hoerter@ncfi.net Authorized Signature James Buckner jimmy@cbuckinc.net I Technical Representative Jason Hoerter Address/Phone/Email 1515 Carter Street Mount Airy,NC 27030 (800)346-8229 jason.hoerter@ncfi.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Spray Applied Polyurethane_Roof System Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By James L. Buckner,P.E. @ CBUCK Engineering 21 Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year UL 1897 2012 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 02/14/2018 Date Validated 02/20/2018 Date Pending FBC Approval Date Approved 03/02/2018 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtg5 eLI2bVuK.... 8/12/2020 Florida Building Code Online Page 2 of 3 Summary of Products FL# Model,Number or Name Description 9806.1 1-"NCFI Roofing System,Spray UL TGIK.R7280#1 NCFI Roofing System,Spray Applied Foam' Applied Foam and Coating System" and Coating System on Plywood or Concrete Deck on Plywood or Concrete Deck Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL9806 R6 C CAC 1 NCFI Foam Roof System UL Approved for use outside HVHZ:Yes TKGI.R72.80.pdf Impact Resistant:No FL9806 R6 C CAC UL Follow-Up Svc Agreernent.pdf Design Pressure: +N/A/-80 Quality Assurance Contract Expiration Date Other:Installation shall comply with the conditions for the 12/31/2021 specific assembly type per UL File TGIK.R7280,#1 Installation Instructions FL9806 R6 II 1 NCFI Foam Roof System UL TKG1_R7280.:L_df Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 9806.2 2-"NCFI Roofing System,Spray UL TGIK.R7280 #2 NCFI Roofing System,Spray Applied Foam Applied Foam and Coating System" and Coating System on Steel Deck on Steel Deck Limits of Use Certification Agency Certificate Approved for use in HVHZ:No <f_980G R6 C CAC 2 NCFI Foam Roof System Ul_ Approved for use outside HVHZ:Yes TKGI.R7280.pdf Impact Resistant:No FL9806 R6 C CAC UL Follow-Up Svc Aoreement.pdf Design Pressure: +N/A/-82.5 Quality Assurance Contract Expiration Date Other:Installation shall comply with the conditions for the 12/31/2021 specific assembly type per UL File TGIK.R7280,#2 Installation Instructions. FL9806 R6 I1 2 NCFI Foam Roof System UL TKGI.R7280.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 9806.3 3-"NCFI Roofing System,Spray UL TGIK.R7280#3 NCFI Roofing System,Spray Applied Foam Applied Foam and Coating System" and Coating System on Steel Deck on Steel Deck Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL9806 R6 C CAC 3 NCFI.Foam Roof System UL Approved for use outside HVHZ:Yes TKGI.R7280.odf Impact Resistant:No FL9806 R6 C CAC UL Follow-Up Svc Aareernent.pdf Design Pressure: +N/A/-45 Quality Assurance Contract Expiration Date Other:Installation shall comply with the conditions for the 12/31/2021 specific assembly type per UL File.TGIK.R7280,#3 Installation Instructions FL9806 R6 II 3 NCFI Foam Roof System UL TKGI.R7280.ndf_ Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 9806.4 4-"NCFI Roofing System,Spray UL TGIK.R7280#4 NCFI Roofing System,Spray Applied Foam Applied Foam and Coating System" and Coating System on Plywood Deck PP 9 Y on Plywood Deck Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL9806 R6 C CAC 4 NCFI Foam Roof System UL Approved for use outside HVHZ:Yes TKGI.R7280.Pdf Impact Resistant:No FL9806 R5 C CAC UL Follow-Up Svc Agreement.odf Design Pressure: +N/A/-105 Quality Assurance Contract Expiration Date Other:Installation shall comply with the conditions for the 12/31/2021 specific assembly type per UL File TGIK.R7280,#4 Installation Instructions FL9806 R6 II 4 NCF1 Foam Roof System UL TKGI.R7280.pclf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 9806.5 5-"NCFI Roofing System,Spray UL TGIK.R7280#5 NCFI Roofing System,Spray Applied Foam Applied Foam.and Coating System" and Coating System on Steel Deck on Steel Deck Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL9;906._REi C CAC 5 1CF1Foam Roof Sy„stem UL Approved for use outside HVHZ:Yes TKGI.R7280.pdf Impact Resistant:No FL9806 R6 C CAC UL Follow-Up Svc Acireement.pdf Design Pressure: +N/A/-82.5 Quality Assurance Contract Expiration Date https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtg5 eLI2bV uK... 8/12/2020 Florida Building Code Online Page 3 of 3 � I Other:Installation shall comply with the conditions for the 12/31/2021 specific assembly type per UL File TGIK.R7280,#5 Installation Instructions FL9806 R6 II 5 NCF1 Foam Roof System UL TKGI.R7280.odf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 9806.6 6-"NCFI Roofing System,Spray ULTGIK.R7280#6 NCFI Roofing System,Spray Applied Foam Applied Foam and Coating System" and Coating System on Steel Deck on Steel Deck Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL9806 R6 C CAC 6 NCFI Foam Roof System UL Approved for use outside HVHZ:Yes TKGI.R7280.Ddf Impact Resistant:No FL9806 R6 C CAC UL Follow-Up Svc Aoreernent.odf Design Pressure: +N/A/-45 Quality Assurance Contract Expiration Date Other:Installation shall comply with the conditions for the 12/31/2021 specific assembly type per UL File TGIK.R7280,#6 Installation Instructions FL9806 R6 II 6 NCFI Foarn Roof System UL TKGI.R7280.vdf _ Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::AccessibilitJ Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: 99 M ' Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtg5eLI2bVuK... 8/12/2020 Aug 12 20,02,27p p.3 �` ONLINE CERTIFICkTIONS DIRECTORY TGIK.R7280 Roofing Systems, Uplift Resistance Page Bottom Roofing Systems, Uplift Resistance See General Information for Roofing Systems, Uplift Resistance NCFI POLYURETHANES R7280 1515 CARTER ST PO BOX 1528 MOUNT AIRyr NC 27030 USA SPRAY APPLIED FOAM AND COATING SYSTEMS I. Uplift Resistance:160 psf Deck:— Min 15/32 in.APA rated plywood sheathing or concrete. Insulation:—Two component, "10-011","591 Series" or"692 Series", spray applied foamed plastic insulation, 1 In. thick min. Roof Coatings:—Fluid applied base and top coating or gravel surfacing systems, applied in accordance with specified combinations and Classified as Roofing Systems (TGFU). 2. Uplift Resistance:165 psf Deck:--Steel, min 26 MSG. Insulation:—Two component, "10-011", "591 Series" or"692 Series", spray applied foamed plastic insulation, 1 in.thick min. Roof Coatings:— Fluid applied base and top coating or gravel surfacing systems, applied in accordance with specified combinations and Classified as Roofing Systems (TGFU). 3. Uplift Resistance:90 psf Deck:—Steel, min 22 g. Insulation(Optional):—Any combination,any thickness of Classified polyisocyanurate, polystyrene, mod fiber or perlite. Cover Board:—Min 1/2 in.thick Classified high density rood fiber board. Fasteners:—Min No. 14 steel screws with 2-7/8 in diameter 26 g galvanized steel plates. A total of 8 screws per 4 ft by 4 ft cover board. Membrane:—Hot-mopped or cold applied built-up roof. Gravel surface removed for recover of existing built-up roof. Insulation:—Two component, "10-011", "591 Series"or"692 Series", spray applied foamed plastic insulation, 1 in, thick min. Roof Coatings:—Fluid applied base and top coating or gravel surfacing systems, applied in accordance with specified combinations and Classified as Roofing Systems (TGFU). 4. Uplift Resistance:210 psf Deck:—Plywood, min 19/32 in. Membrane:— Unlnsulated hot-mopped or cold-applied asphaltic built-up roof.As applicable gravel surfacing removed. Fasteners:—Annular ring shank nails, 0.105 min shank diameter, with 1-7/8 in diameter galvanized steel cap in a 7 in. by 7 in. OC square grid. Insulation:—Tm component, "10-011", "591 Series" or"692 Series", spray applied foamed plastic insulation, 1 in. thick m in. Roof Coatings:— Fluid applied base and top coating or gravel surfacing systems,applied in accordance with specified combinations and Classified as Roofing Systems (TGFU). S. Uplift Resistance:165 psf Deck:—Steel, min 22 g. Sealer.—Two component, "10-011", "591 Series"or"692 Series", spray applied foamed plastic used to seal joints in steel deck, vents and penetrations in steel deck (as applicable)and perimeter. Reinforcement:—Asphait coated fiberglass 10 by 20 in.mesh (not UL Classified) laid across steel deck. Insulation:--Two component, "591 Series"or"692 Series", spray applied foamed plastic insulation, 2 in. thick min. Roof Coatings:— Fluid applied base and top coating or gravel surfacing systems, applied in accordance with specified combinations and Classified as Roofing Systems (TGFU). 6. Uplift Resistance:90 psf Deck:—Steel, min 22 g. Cover Board:— Min 1/2 in. thick Classified high density wood fiberboard. Aug 12 20,02;28p p.4 Fasteners:—Min No. 14 steel screws with 2-3/4 in 26 g galvanized steel plates.A total of 8 fasteners per-4 ft by 4 ft cover board. Insulation:—Two component, "10-011", "591 Series" or"692 Series", spray applied foamed plastic Insulation,2 in.thick m in. Roof Coatings:— Fluid applied base and top coating or gravel surfacing systems,applied in accordance with specified combinations and Classified as Roofing Systems (TGFU). Last Uo¢ated on 2013-08-02 Questions? Print this page Terms of Use Page Top ©2013-UL LLC When the UL Leaf Mario is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured underUL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1.The Guide Information, Assemblies, Constructions, Designs,Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner,without any manipulation of the data (or drawings). 2.The statement"Reprinted from the Online Certifications Directory with permission from UL" must appearadjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format. "© 2013 UL LLC" i