Loading...
HomeMy WebLinkAboutPlot Plan SurveyFjA�zF(qQPY MIN. SET13ACK RE . SIDE CNR iA UNIT 5 (OCCUPIED) — � FlR 6• DE ( 7 28`MI 1 gp.09' 6• DE IFIR tee•-C1-� -r � N i 20.89 j _ S YF i 1 '•'' I 1 I �Il 29-9' I _ UNIT 4 ONE—STORY RESIDENCE 30.5' A ^ Z v o tt -0 1 Frool p I _ i 20.01n 1 �wx w Wyy p pto n u n o 0 n� 35.2 m J _ O 0 10 __________ }5.1' i 22.r__ _ 11W WL71 PAVER BRICK_ POOL d Y M 2D.45' 47- _ 23.4'-36.4'yn N cot +�5 VF allot bzzt 1.50'i m23.4• 34.6'_________ N Z CONCRETE- DRIVEWAY wl N I jj I FIR (Basis of BeaIhg N 14p 00' sas X_CU f PROPOSED PAVER BRICKN7a41'2R ) ADDITION (TO BE SCREENED) �• MATCH E1aSRNG PATIO ELEVATION 14 UNIT 3 " 11 (OCCUPIED) I TRANg=ER ig LEGEND DUNE 14, 2020 Date of Signature WILUAM B. BENNETT Professlwal Surveyor & MapPw Florida Certificate No, 6353 LB No. 76M ® = SANITARY MANHOLE 0. - CENTERLINE RIGHT OF WAY EP - EDGE OF PAVEMENT FlRC = FOUND 5/8-IRON ROD & CAP (UNNUMBERED) FIR = FOUND 5/8• IRON ROD (UNNUMBERED) FND = FOUND NAIL (UNNUMBERED) D - DELTA ANGLE L = ARC LENTH R = RADIUS DE = DRAINAGE EASEMENT UE = UTIUTY EASEMENT RECEIVED JUL 10 2020 ST. Lucie County, Permitting J- CIF 0 "SI TE 4 Vicinity Yap (Not To seek) LEGAL DESCRIPTION: Unit 4, HARBOUR RIDGE PLAT 7-BAY13ERRY VILLAGE. according to the map or plat thereof, as recorded In Plat Book 26. at Page 3 ('A' through 'B'). of the Public Records of St Lucie County, Florida. LOT AREA 13.672 Sq. Ft; 0.32 Avert STREET ADDRESS: 1810 NW Buttwbush Circle. Polm City Florida 34990. SURVEYORS' NOTES: n re 1. Bearings shown hereon ore based on the South fine of Unit 4 as platted and beamN 70.41'25' W. 0 S p 2. Written dimensions take precedence over scaed dimensions and distances are not to be styled for construction and/or design purposes 1� 3. All distances and bearings are as field measured and are coincident with as 'PLAT' and description data unless otherwise noted. A 4. This drawing is not valid without the signature and original raised seal of a Florida licensed Surveyor & Mapper. 5. This survey Is based upon a description furnished by the client. there has been no search of the public records done by this office. 6. Property Has In Flood Zone X as scaled from the National Flood Insurance Program Rote Map. Community Panel Number 12111CD406 K. with an effective date of Fcbruary 19. 2020, 7. This survey Is not covered by professional liability insurance. & City water & sewer are awiloble in this area. 9. This survey meets the required aoauacy, as shown In Ch. 5J-17.051 (2) (b) r o based on its expected use. 0o sa 6 10. No underground utilities or Improvements were located unless otherwise shown. mD Iz A3 ui 11. Elevations shown hereon, if any are based upon an assumed datum. iv �r m 12. This plan information to be verified by contractor prior to construction. ® = SANITARY CLEANGUT CONIC = CONCRETE A = TELEPHONE RISER • = WATER METER A/C - AIR CONDITIONER PAD WF - WOOD FENCE MF - METAL FENCE _ t = PLUS OR MINUS PEP - POOL EQUIPMENT PAD H20 - WATER TREATMENT PAD 0 = MAILBOX 0 - ELEC11C SERVICE MANHOLE ® - CATCH BASIN CERTIFIED TO: BDC BARCOS INVESTMENT CORPORATION uoro or yam weta wont Boundary Survey & Site Plan l ee n n ett Prepared on the order of: BDC Barcos Bennett Surveying. Inc. Investment Corporation &pHsr. Florida �33458 Plaid: dP B Job No.: 20-0602', bob 772.336AS33 Drmene WB I Date: 08/14 2020 .effwil.aa.cam beftne ffVrjWgOyahSealy. 1'-20' Shaw!: i of 1 Izr o Z U � W w LT. F-+ .F`1. H-I U �cqU xo� U 00 co co ti M t� t� l� Lo ti Q ce) w C/] H c5 w C/D W cojLa -� Z 00 O ti ti 5 a. a rn F H SHEET MBER 60F6 r. STRUCTURE CRITERIA xo DESIGN: RECEIVEa *THIS OVERALL DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 AND 20 OF THE 2017 FLORIDA BUILDING CODE 6TH EDITION, BUILDING AND ALL OTHER APPLICABLE STANDARDS 1 0 JUL 2020 w qw WIND CRITERIA: *VELOCITY: 150 MPH (3 SECOND GUST), EXPOSURE C , RISK CATEGORY I. ST. Lucie county, Permitting W E~ N h FOR VELOCITY >100 MILES PER HOUR, IMPORTANCE FACTOR SHALL = 0.77. U F O SCREEN DESIGN: a *18 X 14 SCREEN WALLS: WW PRESSURE @ 19.6 PSF, LW PRESSURE @ 15.6 PSF, ROOF @ 5.4 PSF DESIGN PRESSURE ON BUILDING ENVELOPE ELEMENTS: *PER THE ALLOWABLE STRESS DESIGN FOUND ON TABLE 2002.4 AND 2002.4A OF THE FLORIDA BUILDING CODE. z c *THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN IN THE DRAWING. THE ACTUAL SPACING BETWEEN ANY TWO BEAMS MUST o Ls ' M a BE THE AVERAGE SPACING, +/_ 20, AND THE CENTER TO CENTER MUST NEVER BE GREATER THAN 8'-0". N o"M *EXTERIOR GLAZED OPENINGS SHALL BE PROTECTED BY PRODUCTS `V EYE "&-, " " z WHICH MEET THE REQUIREMENTS OF SSTD 12. c a a __j Co SCREEN ENCLOSURE ROOF TYPE o U Co o *COMBINATION OF MANSARD ROOF ENCLOSURE WITH 3'0" RISE MAX. AND A FLAT SCREEN ROOF, STRUCTURE IS CONNECTED TO EXISTING SINGLE STORY C.B.S. HOME WITH WOOD FASCIA. (SEE CONNECTION DETAIL 4 ON PAGE 3). *THIS ENCLOSURE WILL BE CONSTRUCTED ON AN EXISTING PAVER PATIO WITH,FOOTER POOL PATIO, AND A NEW ADDITION WITH AN 8" X CONCRETE FOOTER WITH 1 #5 BAR CONTINUOUS. THIS FOUNDATION IS ACCEPTABLE FOR THIS ENCLOSURE. *ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 12" ON CENTER W/2-1/4" MIN. EMBEDMENT INTO CONCRETE.wa ALUMINUM NOTES: MATERIALS SHALL CONFORM TO THE F.B.C., CHANGES SHALL BE DESIGNATED BY THE ENGINEER OF RECORD: 1: ALL EXTRUSIONS: ALUMINUM ALLOY #6005-T5 OR 6061-T6, (NOTE: SPLICE PLATE MATERIAL MAY BE EXTRUDED FROM ALUMINUM ALLOY 6061-T6, IF THIS ALLOY IS MORE READILY AVAILABLE). 2: FASTENERS: ALUMINUM ALLOY # 2024-T4 & #7075-T6 DOUBLE CAD -PLATED STEEL, HOT DIPPED GALVANIZED STEEL OR 300-SERIES STAINLESS STEEL 3: MATERIAL UPGRADES (STRONGER OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME. 4: NO EXPANSION BOLT MAY BE INSTALLED WITHIN 2" OF EDGE OF CONCRETE SLAB. 5: NON STRUCTURAL ALUMINUM SHALL HAVE A MINIMUM THICKNESS NO LESS THAN 0.032" (KICKPLATES ETC.) FILE 6: ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH COPY ALKALI RESISTANT COATING. 7: ALUMINUM IN CONTACT WITH WOOD SHALL BE PAINTED WITH TWO COATS OF HEAVY BODIED BITUMINOUS PAINT. REVIEWED 8: SELF MATING BEAMS (SMB) UP TO 8" TO BE FASTENED WITH BEAM STITCH SCREWS @ 16" O/C FOR BOTH SIDES. (#12 SMS), FOR 9" & 10" SELF MATING BEAMS (SMB) TO BE FASTENED WITH BEAM CODE COMPLIANCE STITCH SCREWS @ 12" 0/C. ST• L CIE COUNTY ATR00,C llgeg U W W za Cn SHEET MMER 1 OF 6 2: a M N ISOLATED FOOTING SEE CONNECTION 3 ON PAGE 5 1 PLAN VIEW Scala• 3l1R" v EXISTING POOL PATIO 53.4' 54'-0" 8" X 8" CONCRETE FOOTER ALONG PERIMETER WITH 1 45 BAR CONTINUOUS CONCRETE SPECIFICATION NOTES AND DESIGN PARAMETERS 1)- 6" X 6" 10/10 WWM OR FIBERMESH ADDED CONCRETE. 2)- TERMITE TREATED SOIL WHEN NEXT TO LIVING SPACE. 3)- FOOTER SHALL BE 8" X 8" FOR PERIMETERS WITH ONE (1) #5 REBAR CONTINUOUS 3000 PSI CONCRETE FILLER N PROPOSED 1'-6" PAVER ADDITION WITH ,FOOTER AROUND PERIMETER ISOLATED FOOTING SEE CONNECTION 3 ON PAGE 5 REVIEWED FOk CODE COMPLIANCE ST. LUCIE COUNTY Rocc 1-#5 BAR CONTINUOUS �FOOTER ELEVATION ELEVATION 4 E O LV O r U Wu00 Um cz cn Ca n ch w0Lt. H E a4 � U U F O � U�p¢., 00 00 rn wst� ate'• rn 1Z-I>co El .�xWE�„a�CS a¢ 00Fa rno w M ti M ti N ti N N ICJ Ll�l� m C w cn a Lo m 00 ao O t- N ti x a SHEET NUMBER 2OF6 1 on x PLAN VIEW ELEVATION B. 2 FRONT WALL B=BEAM P=POST/PURLIN CR=CHAIR RAIL DJ=DOOR JAMB K/B=KAY-BRACE W/B=WIND BRACE O 9- MEMBER SC JEDULE MARK SIZE MAT. THICKNESS DESIGN W. I F. El 2'X S' ALUM. 0.072 0.224 PER ENG. Pi 4'X 4' ALUM. 0. 125 0.125 PER ENG. P2 2'X 3' ALUM. 0.050 0.050 PER ENG. P3 2% 6' ALUM. 0.050 0.116 PER ENG. P4 1% 2' ALUM. 0.046 0.046 PER ENG. CR 2'X 3' ALUM, 0.050 0.050 PER ENG. DJ 2% 2' ALUM. 0.046 0.046 PER. ENG. W/B 2'X 2' ALUM. 0. 090 0. 090 PER. ENG. ELEVATION C. 4 SIDE WALL LEVATION A. 4 SIDE WALL REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY of% s CW?um Z d� WCa N M W C C, F F F � U x C> n SHEET NWER 3OF6 r MITES SPLICES SHOWN FOR MANSARD SPLICES, IDENTICAL SPECIFICATIONS FOR GABLE AND/OR MIGHT BEAN SPLICES O 0 O SLPICE PLATE ALLOY: 6061T6 OR 50521132 6... 6..6: O; O O Oj --*OiINTERNAL SPLICE PLATE ,I7! 4D Z 1� SCREW POSITIONS NEAR MITER l e�gpB>Y' , Y SCREW PoSITI," NEAR LITER JOINT MAY BE ADJUSTED TO ACCOMODATE PURLIN, SPACE BETWEEN FASTENERS ALONG MITER JOINT MAY 1 1/2' TO 2', MANTAIN MAXIMUM AND MINIMUM DISTANCES BETWEEN SCEWS. EDGE DISTANCE FOR SCREWS: 31C MINIMUM SCREW SPACING: 5/8" SPLICE SPECIFICATIONS PER TABLE 109 BELOW Ir IUAL IlLISVRIlVA run 151IRM MlIISX OrL1l,C/ (DETAIL MAY BE ROTATED FOR GABLE RIDGE SPLICE, AND MAY \\1� ALSO SERVE AS SPECIFICATIONS FOR A STRAIGHT SPLICE, MANTAIN PLATE AND CONNECTOR SPECIFICATIONS IN TABLE 109 FOR ALL) BEAM SLPICE DETAILS TABLE 109 BEAM SPLICE PATH DI(ENTIONS #14 SMS PER SIDE PER END TOTAL #14 SMS PER SPLICE FASTENER SPACES rHICKNESS LENGTH HEIGTH NUMBER OF SPACES HORIZONTAL VERTICAL 2X6XO.050XO.120 SMB 3/16' 16' 5 1/4' 14 56 3 3 2X7XO.055XO.120 SMB 3/16' 16' 6 1/4' 14 56 3 3 2X8XO.072XO.224 SMB 3/16 18' 7 I/4' 16 64 4 3 2X9XO.082XO. 306 SMB 3/16 18 8 l/4 18 72 4 4 2X10XO. 092XO. 389 SMB 1/4' 20- 9' 22 88 4 6 IF DESIRED THE 3Z' BOLT SHOWN IN THE WIND BRACING CONNECTION THAT SECURES THE 2 X 2 X 0.90 MEMBER TO THE U-BRACKET AND THE U. BRACKET TO THE ROOF BEAM CAN BE REPLACED WITH FOUR (4) $14 SMS. THE #14 SMS. MUST BE 1fY' FROM THE END OF THE U-BRACKET AND AT LEAST 314' A (STAGGERED) FROM EACH OTHER. 1/4' THROUGH BOLT U-BRACKET \ (CHANNEL) # 14 SMS TWO ON EACH SIDE OF BRACE ROOF BEAM 1/8' OD # 14 SKIS TWO ON EACH SIDE OF BRACE N ALTERNATE % CON'NECIJON OF CHANNEL (4) EACH #14 SUS THRU CHANNEL BFAV GB VERLM WEB TIR U BEAM WEBIN70 BACKIN SECTION PLATE (U-BRACKET CHANNEL) 1/4' THROUGH BOLT PURLIN OR LAVE RAIL 3 SCREEN ROOF DIAGONAL WIND BRACE MS "Z" GUTTER INSERT IN SUPER GUTTER TO HOUSE CONNECTION 10' LNG (0. IM THICK ) EXTRUDED 'Z' BAR 4- 1/4"X 2 1/4' LAGS IN EACH 10' INCH INSERT GUTTER INSERT, TYP. CENTERED ON EACH ROOF AUTO AT 24- 0.C. WAX. SPACING) IN THE REST OF BEAR, WITH (4) FOUR It 14 TEES THIRD TOP LIP OF THE GUTTER (PILOT DRILL FASCIA W/6/32' BIT TO GUTTER AVOID SPLITTING) 6' STRUCTURAL GUTTER n in (CONT.) ?AGAI� X2 SCHEEIR FRAME (TYP.) 'Z' GUTTER INSERT [IS" SUER GUTTER 125' (CUT' 2' TANG) WITH 3-INCH LEG CLIP, SHALL HAVE FOUR (4) # 14 GUTTER ELEVATION F ROOF BEAM AND TWO (2) #14 X 2' TYP. 2V SCREEN ROOF BEAM (WAY BE(PER ANGLE CLIP) THEM GUTTER AND FLAT OR SLOPED) IM1SERI(7YP. O\Ti MULE CLIP ON F EACH BEAM 4 TOP VIEW PLAN CC5 .~+� W 01 G CtW-iUZ �ua a¢ L�..o w REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY SHEET NUMBER IRor.rl 4 OF I SECTION/SIDE ELEVATION FOR 2"M4 SMB THRU 2"X10" SMB G —�_ EMT POST / COLUHN 2' X 3' X 3/I6' ANGLE 2' LONG W/3 EACH # 14 SHS INTO POST WEB 2' X 3' X 3/16' ANGLES 3' LONG 01INIMAD 4'X B" X 23/8" BRICK PAVER PATIO CONCRETE POOTER 04 ' TOP CON 1/2 I/2' EHBEWBAT INTO coN( SITE 4- # 10 S.M.S. FROM INSIDE FACE OF POST INTO SCREW SPLINES OF HOLLOW GIRT ( I' EMBEDMENT MINIMUM.) 2' x 3' PURLIN MAY BE SLOPING OR HORIZONTAL MAXIMUN POST HEIGTH (SPAN) 18' -0' FOR NOWINAL 4' PATIO SLAB, DO NOT EXCEED 2 3/4' DEPTH FOR MICRETE ANCHORS, WHERE CONCRETE DEPTH EXCEEDS 3 1/2' DEPTH, ANCHORS MY BE EIBEDDED UP TO CONCRETE DEPTH DIVIDED BY 1.25 DETAIL — ELEVATIONS SHOW THE FOUNDATION CONNECTIONS FOR VARIOUS DEPTH WU14XS (POST'/UPRIGHTS). COLUIVS (POST/UPRIGRTS) MUST NOT EXCEED ALLOWABLE SPANS 2' X 2'/ 2' X 3' OR 3' X 2' HOLLOW HORIZONTAL (GIRT). SELF MATING POST OR HOLLOW POST. OVERLAP BEAM WITH 2- #12 S. M. S ON EACH SIDE COLUMN (PER TABLE) 2 EACH #10 S.M.S X 4' LONG THRU HAVE RAIL 2X2 INTO SLOPING PURLIN SCREW SPLINES END WALL PERLIN CONNECTION DETAIL 6 ALUM. POST • BRICK PAVERS • As a4R®ir N 0 � 1'-4' X V-4" X 2' 0' IN DEPTH 7�-P CONCRETE FOOTER #5 BAR X IS'LONG EACH WAY TRHU OS T'-4" 9 ISOLATED FOOTING DETAIL Scale: 3 4" = P-0" ROC'= C=AAA PERLIN FRONT VIEW 2-A 3" PERLIN WITH 1 #14 INTO BEAM @ 16" 3"ANGLE EACH SIDE 3EAM WITH 3414 S.M.S. INTO EACH BEAM. -- 5 BEAM ATTACHMENT. TO,FRONT WALL 2' X 3' PURLIN (MAXIMW PURLIN SPACING 7' -0' ) SCREEN ROOF BEAMS - SIZE PER TABLE / MAXIMUM SPACING 8' - 0' 0. C. ROOFBEAM #12 X 3/4' SALS @24'0/C.TOP & BOTTOM - D131-ALUAL BEAM 114 x3/4'SNVS @24- 0/C. TOP AND BOTTOM STAGGERED 4- X 16' X 1/R' ALUM. STRAP EACH SICE. - ALML POW 3/8' T14l000H BOLTS BEAM FASTENING 2" X 3" ANGLE ON EACH SIDE OF BEAM WITH 3414 S.M.S. INTO EACH BEAM. SIDE VIEW BEAM STITCH SCREW 0 24' O.C. TOP AND BOTTOM (#12 SMS TYPICAL) 4 EACH #10 X 2' LONG S.M.S. (TYPICAL) INTO SCREW BOSSES. 0 ROOF/SECTION OF CONCEALED FASTENER CONNECTION 4 O GUHCN 2 U � O O O12M "I w F F F U C� Fob U 0. O Trl Obi Lj Q" N G Uzi i�r tF [as. N "m. mxz �YoU� Siam-E-: � UOOF (L rs. REVIEWED FOR CODE COMPLIANCE ST. LUCIIE COUNTY Roce SHEET N(IMBER 5OF6 Co ti M I t� ti ti