Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPA FL10674-R15SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
db'p'*r
j R .�' Product Approval
tf USER: Public User
Product ADproyal Menu > Product or AplAcation Search > ADolication List > Application Detail
FL # FL10674-R15
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Robert J.M. Nieminen
PE -59166
PRI Construction Materials Technologies, LLC
01/01/2099
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10674_R15_COI_2019_O1_COI_NIEMINEN.pdf
Standard
Year
ASTM D1970
2015
ASTM D3161
2016
ASTM D3462
2010
ASTM D7158
2011
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/15/2019
Date Validated 08/15/2019
Date Pending FBC Approval 08/21/2019
Date Approved 10/15/2019
Summary of Products
FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
Shingles and Starters
3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge
shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: YesHIS
Impact Resistant: N/A
FL10674_RI5_jl_2019_Q$_FINAL_M_Q.C_ASPHALT
N I S F 10674-R1 .per
Verified By: Robert J. M. Nieminen PE - 59166
Design Pressure: N/A
Other: Refer to ER, Section 5.
Created by Independent Third Party: Yes
Evaluation Reports
ELIDL74_R].S-AE_2U9_QB_EINAL_ER_O-C-A.S -HALF
SHINGLES FL10674-R15.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399Phone: 850-487-1824
The State of Florida is an AA/EEO employer. SQpyright 2007-2013 State of Florida :: Privacy, Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
Credit Card
Safe
securitynIETRICa
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
EVALUATION O.
Owens Corning Evaluation Report 037940.02.12-1110
One Owens Corning Parkway FL10674-1115
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 10: 08/15/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen P.E.
�= r=
The facsimile seal appearing was authorized by Robert
,,a� .••—••' c';•�E•
Nieminen, P.E. on 08/15/2019. This does not serve as an
Florida Registration No. 59155, Florida DCAANE1983
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMOletc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMOIetc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
©2018, NEMO ETC, LLC
(NNEMOJetc.
ROOFING SYSTEMS EVALUATION:
4.1 ACCESSORY STARTERS:
4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets
ASTM D3462.
4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip,
nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970.
4.2 ASPHALT SHINGLES:
4.2.1 Classic" and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462.
4.2.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462.
4.2.3 Duration', TruDefin(tion Duration, Duration' Premium Cool, Trudefinition' Duration' Designer Color Collection,
TruDefinition Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof
shingles. Meets ASTM D3462.
4.3 HIP & RIDGE SHINGLES:
4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdgell Hip & Ridge
Shingles and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
Meets ASTM D3462.
NEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate afAutharizatioa 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
n- i, -s in
Product Category:
Roofing
Sub -Category:
Asphalt Shingles
Compliance Statement:
Owens Corning Asphalt Roof Shingles, as produced
by Owens Corning, have
demonstrated compliance
with the following sections of
the 61h Edition (2017) Florida Building Code and Florida
Building Code, Residential
Volume through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations J Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.4, 8905.2.3
Physical Properties
ASTM D1970
2015
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2010
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2016
1507.2.7.1, 8905.2.6.1
Wind Resistance
ASTM D7158
2011
3. REFERENCES:
Enti
Examination
Reference
Date
Owens Corning
Declaration
Equivalency Declaration
08/06/2019
PRI (TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-112453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
4.1 ACCESSORY STARTERS:
4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets
ASTM D3462.
4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip,
nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970.
4.2 ASPHALT SHINGLES:
4.2.1 Classic" and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462.
4.2.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462.
4.2.3 Duration', TruDefin(tion Duration, Duration' Premium Cool, Trudefinition' Duration' Designer Color Collection,
TruDefinition Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof
shingles. Meets ASTM D3462.
4.3 HIP & RIDGE SHINGLES:
4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdgell Hip & Ridge
Shingles and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
Meets ASTM D3462.
NEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate afAutharizatioa 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
n- i, -s in
U(4
MEMO I etc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Wind Classification:
5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones
UP to V,,d =150 mph (V"it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions
outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip
& ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to
ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vasd = 150 mph (V,lt = 194 mph). Refer to
Section 6 for installation requirements to meet this wind rating.
5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Fahundedavment
--Dack
'v SaN-adhered
,Weadt ,Locke
undedaynxnt
e
Drip edge
.r. - Nails located
2"-3" imm eave
r
Instal first
Sell -sealing adhesive
Starter suip.y
positioned along eave
rm
1. ad
6"emoved Sorter Strip shingle owhanas eaves and rakes 'A%'
Figure 1: Minimum Nailing, Starter Strip
Figure 2: Minimum Nailing, Starter Strip Plus
NEW ETC, LLC Evaluation Report 037940.02.12-1110
Certificate ofAuthorizotion#32455 ST" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
D- Zof 1n
U(4
MEMO I etc.
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
Deck
Undedayment
Drip edge
' Drip edge
Starter Shingle Roll adhered
directiy to underlayment and
primed drip edge
Self-sealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
6.3 ASPHALT SHINGLES:
6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire® shingles require minimum five (5) nails per shingle.
➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Classic® & Supreme:
Normal Mansard or Area para
Wind Areas High Wind desvanes y
Area para vientos normal" Areas vientos fuertes
r tr
(A)�
5°Exposure
Exposition
Figure 4: Minimum Nailing, Classic & Supreme
(Standard Size)
Normal Mansard or Area para
Wind Areas High Wind desvenes y
Area para vientos normales Areas vientos fuertes
t (A) p rt• z% (BI r2• t Z
tz tz t
5 51W Exposure
£xposicidn
Figure 5: Minimum Nailing, Classic & Supreme
(Metric Size)
NEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
D-n..F in
6.3.1.2 Berkshire®:
Sealant strip
La fire de seUadar
R Yz" 9 Vt' 9 Srz R kY
Figure 6: 5 -Nail Pattern, Berkshire
UN
MEMO I etc.
Figure 7: 6 -Nail Pattern, Berkshire
Figure 8: Mansard or Steep Slope Pattern, Berkshire
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
D—cnf In
UN
NEMA j etc.
6.3.1.3 Duration®, TruDefinition® Duration, Duration® Premium Cool & Trudefinition` Duration" Designer Color Collection:
4 -Nail Fastening Pattern
SureNaft fastening area width
Nail, Typical
VT 12" 12" 1„
W—C—mg Sue W- • �p ,amg 8mum� sUae.,o _—• G.—C.. S—N 'a • .
6-118" 5.578.•
------------ j
e,Po,u�
Figure 9: Standard 4 -Nail Pattern, Duration
Figure 10: 6 -Nail Pattern, Duration
Fastening for Slopes Greater Than 21:12
9ureNail(J fastening area width
Nail, Typical
1" 12" 12"rt
1"
•}wens Comvng Swrsl...A •s'=�":ams BU4Utn�sea s O,cEn Cwnin9 Snr&7a3
8-178" 5518"
tx„nsnre
Four 1" Spots of Asphalt Roofing Cement i
Figure 11: Mansard or Steep Slope Pattern, Duration
NEW ETC, LLC Evaluation Report 037940.02.12-1110
Certificate afAutharization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1115
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
D>. -n C —4 1n
((4-)
MEMO I etc.
6.3.1.4 TruDefinitione Oakridge®, Oakridge®:
4 Nail Pattern
EsWema con 4 claws
1' V
12" —�►!
55/8" Exposure Nails 5 518" Exposure
Exposidon de v SIe pufg. Clavas Exposition de 5 6/3 pufg.
Figure 12: Standard 4 -Nail Pattern, Oakridge
6 Nail Pattsm
Esquema con 8 clavas
5518" _F__
Exposkba de 551e pufg.
Glavos a ata cayv um
Exposid6t; de 561epufg.
Figure 13: 6 -Nail Pattern, Oakridge
Fastening for Slopes Greater Than 21:12
suraNail06 fastening area width
/r Nat[, Typical
•+m rxi�65wcM1aJT' i �':a�r.5 �:uuro>eit ij i n,Rm <«MnnSwo..,3a •
f:t/8" 5-518"
Four t" Spots of Asphalt Roofing Cement
Figure 14: Mansard or Steep -Slope Pattern, Oakridge
MEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate of Authorization#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
D- 7.,r in
6.3.1.5 WeatherGuard" HP:
N34 cb,%
E 5e• E!< asif4
txpasi il6a de 5 53$ pL:g.
Expo !666 de 5 61 pu1�
Figure 15: 6 -Nail Pattern, WeatherGuard HP
6Na] Pattern
Esruema con 6 clavos Nail 6118" from bottom
of shingle
Clave a 6 118 puke. de la
5 518" Exposure 6 suae a ares parte inferior de la t0a
Exposici6n de 5 5,B pulg. 1
Four 1" Spots of Asphalt Roof Cement
Cuatro punlos de cemeuto de techo de asfa#o de t pulgada
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
(04
NEMO I etc.
6.4 HIP & RIDGE SHINGLES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire® Hip and Ridge Shingles with Sealant and Dura Ridge" Hip & Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard" HP Hip and Ridge Shingles and ProEdge" Hip & Ridge Shingles require minimum four (4)
nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
NEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate of Authorization X32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R1S
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
Dee -4-4: in
U(4
NEMO I etc.
6.4.1.1 Berkshire® Hip & Ridge with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant:
Fig. A
Prevailing Wind Direction
E— Direcci6n del viento predominante
Nails
Clavos -\\ I
"`YYY I I
A I I
IF—
P
GFg Ezgosure I
xpsitidn de 8 paIq
4
4
Figure 17: Isometric View, Berkshire and DuraRidge
6.4.1.2 WeatherGuard® HP Hip & Ridge Shingles:
Fig. Q q q
Prevailing Wind
Direction \ A
Nails A
44
I I
i I I I
1 AA, 1 j I I
Expesum
�y
Figure 19: Isometric View, WeatherGuard HP Hip & Ridge
Fig. B
Top View
Vista superior
I1 H
Nail
25/s' Clavo
I • Owens Corning StweNail` +
I
I—
(D
g'
c I ai
vIc
Iv
I
I
E 12"
Figure 18: Plan View, Berkshire and DuraRidge
Fig. C Hip & Ridge Shingle Fastening
Top View
Nails Nails
T'
1 �r
sy Exposure
Figure 20: Plan View, WeatherGuard HP Hip & Ridge
NEMO ETC, LLC Evaluation Report 037940.02.12-R10
Certificate ofAuthorizotion #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS
Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019
noon a nF to
6.4.1.3 ProEdge° Hip & Ridge Shingles:
Prevailing
Wind Direction Sealant Strip
6" Exposure
Fasten 7112"
Cover Exposed
Fasteners with
N Reof Cement
Figure 21: Isometric View, ProEdge
UN
NEM@ I etc.
Standard
Fastening
tt„
Pattern
Y -•Z.
t2'
Sealant
,s+2"
b" Exposure
Figure 22: Plan View, ProEdge
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table
1507.2.7.1 / R905.2.6.1.
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation
of this product.
90- MANUFACTURING I PLAN 11 TS:
Contact the named CIA entity for information on which plants produce products covered by Florida Rule 61620-3
QA requirements.
t QUALI Ty AssuRANCE ENTITY:
PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777; bwilson@pricmt.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 037940.02.12-1110
Certificate of Authorization #32455 6T" EDITION (2017) FBG NON-HVHZ EVALUATION FL10674-R15
Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019
D- in -f in