Loading...
HomeMy WebLinkAboutPA FL10674-R15SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search db'p'*r j R .�' Product Approval tf USER: Public User Product ADproyal Menu > Product or AplAcation Search > ADolication List > Application Detail FL # FL10674-R15 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com Greg Keeler greg.keeler@owenscorning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Roofing Asphalt Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert J.M. Nieminen PE -59166 PRI Construction Materials Technologies, LLC 01/01/2099 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL10674_R15_COI_2019_O1_COI_NIEMINEN.pdf Standard Year ASTM D1970 2015 ASTM D3161 2016 ASTM D3462 2010 ASTM D7158 2011 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 08/15/2019 Date Validated 08/15/2019 Date Pending FBC Approval 08/21/2019 Date Approved 10/15/2019 Summary of Products FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing Shingles and Starters 3 -tab, 4 -tab, 5 -tab, laminated, starter and hip & ridge shingles Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: YesHIS Impact Resistant: N/A FL10674_RI5_jl_2019_Q$_FINAL_M_Q.C_ASPHALT N I S F 10674-R1 .per Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Other: Refer to ER, Section 5. Created by Independent Third Party: Yes Evaluation Reports ELIDL74_R].S-AE_2U9_QB_EINAL_ER_O-C-A.S -HALF SHINGLES FL10674-R15.pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399Phone: 850-487-1824 The State of Florida is an AA/EEO employer. SQpyright 2007-2013 State of Florida :: Privacy, Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: Credit Card Safe securitynIETRICa NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION O. Owens Corning Evaluation Report 037940.02.12-1110 One Owens Corning Parkway FL10674-1115 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 10: 08/15/2019 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen P.E. �= r= The facsimile seal appearing was authorized by Robert ,,a� .••—••' c';•�E• Nieminen, P.E. on 08/15/2019. This does not serve as an Florida Registration No. 59155, Florida DCAANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMOletc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMOIetc. is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO I etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC (NNEMOJetc. ROOFING SYSTEMS EVALUATION: 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic" and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration', TruDefin(tion Duration, Duration' Premium Cool, Trudefinition' Duration' Designer Color Collection, TruDefinition Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdgell Hip & Ridge Shingles and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate afAutharizatioa 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 n- i, -s in Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations J Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4, 8905.2.3 Physical Properties ASTM D1970 2015 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, 8905.2.6.1 Wind Resistance ASTM D7158 2011 3. REFERENCES: Enti Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI (TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 4.1 ACCESSORY STARTERS: 4.1.1 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter are starter strips for asphalt roof shingles. Meets ASTM D3462. 4.1.2 Starter Shingle Roll is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 7.2 -inch wide x 33 -ft 4 -inch long roll, for use with asphalt shingles. Meets ASTM D1970. 4.2 ASPHALT SHINGLES: 4.2.1 Classic" and Supreme' are fiberglass reinforced, 3 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.2 Berkshire are fiberglass reinforced, 4 -tab asphalt roof shingles. Meets ASTM D3462. 4.2.3 Duration', TruDefin(tion Duration, Duration' Premium Cool, Trudefinition' Duration' Designer Color Collection, TruDefinition Oakridge', Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. Meets ASTM D3462. 4.3 HIP & RIDGE SHINGLES: 4.3.1 Berkshire' Hip & Ridge Shingles with Sealant, DuraRidge® Hip & Ridge Shingles with Sealant, ProEdgell Hip & Ridge Shingles and WeatherGuard° HP Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Meets ASTM D3462. NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate afAutharizatioa 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 n- i, -s in U(4 MEMO I etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The Owens Corning asphalt shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating acceptable use in all wind zones UP to V,,d =150 mph (V"it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. Note: Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.2 Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter noted in Section 4.1.1 and the Owens Corning hip & ridge shingles noted in Section 4.3 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating acceptable use in all wind zones up to Vasd = 150 mph (V,lt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Fahundedavment --Dack 'v SaN-adhered ,Weadt ,Locke undedaynxnt e Drip edge .r. - Nails located 2"-3" imm eave r Instal first Sell -sealing adhesive Starter suip.y positioned along eave rm 1. ad 6"emoved Sorter Strip shingle owhanas eaves and rakes 'A%' Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEW ETC, LLC Evaluation Report 037940.02.12-1110 Certificate ofAuthorizotion#32455 ST" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 D- Zof 1n U(4 MEMO I etc. 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. Deck Undedayment Drip edge ' Drip edge Starter Shingle Roll adhered directiy to underlayment and primed drip edge Self-sealing adhesive positioned along eaves Figure 3: Starter Shingle Roll 6.3 ASPHALT SHINGLES: 6.3.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire® shingles require minimum five (5) nails per shingle. ➢ WeatherGuard® HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Classic® & Supreme: Normal Mansard or Area para Wind Areas High Wind desvanes y Area para vientos normal" Areas vientos fuertes r tr (A)� 5°Exposure Exposition Figure 4: Minimum Nailing, Classic & Supreme (Standard Size) Normal Mansard or Area para Wind Areas High Wind desvenes y Area para vientos normales Areas vientos fuertes t (A) p rt• z% (BI r2• t Z tz tz t 5 51W Exposure £xposicidn Figure 5: Minimum Nailing, Classic & Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization 1132455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 D-n..F in 6.3.1.2 Berkshire®: Sealant strip La fire de seUadar R Yz" 9 Vt' 9 Srz R kY Figure 6: 5 -Nail Pattern, Berkshire UN MEMO I etc. Figure 7: 6 -Nail Pattern, Berkshire Figure 8: Mansard or Steep Slope Pattern, Berkshire NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 D—cnf In UN NEMA j etc. 6.3.1.3 Duration®, TruDefinition® Duration, Duration® Premium Cool & Trudefinition` Duration" Designer Color Collection: 4 -Nail Fastening Pattern SureNaft fastening area width Nail, Typical VT 12" 12" 1„ W—C—mg Sue W- • �p ,amg 8mum� sUae.,o _—• G.—C.. S—N 'a • . 6-118" 5.578.• ------------ j e,Po,u� Figure 9: Standard 4 -Nail Pattern, Duration Figure 10: 6 -Nail Pattern, Duration Fastening for Slopes Greater Than 21:12 9ureNail(J fastening area width Nail, Typical 1" 12" 12"rt 1" •}wens Comvng Swrsl...A •s'=�":ams BU4Utn�sea s O,cEn Cwnin9 Snr&7a3 8-178" 5518" tx„nsnre Four 1" Spots of Asphalt Roofing Cement i Figure 11: Mansard or Steep Slope Pattern, Duration NEW ETC, LLC Evaluation Report 037940.02.12-1110 Certificate afAutharization #32455 6- EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-1115 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 D>. -n C —4 1n ((4-) MEMO I etc. 6.3.1.4 TruDefinitione Oakridge®, Oakridge®: 4 Nail Pattern EsWema con 4 claws 1' V 12" —�►! 55/8" Exposure Nails 5 518" Exposure Exposidon de v SIe pufg. Clavas Exposition de 5 6/3 pufg. Figure 12: Standard 4 -Nail Pattern, Oakridge 6 Nail Pattsm Esquema con 8 clavas 5518" _F__ Exposkba de 551e pufg. Glavos a ata cayv um Exposid6t; de 561epufg. Figure 13: 6 -Nail Pattern, Oakridge Fastening for Slopes Greater Than 21:12 suraNail06 fastening area width /r Nat[, Typical •+m rxi�65wcM1aJT' i �':a�r.5 �:uuro>eit ij i n,Rm <«MnnSwo..,3a • f:t/8" 5-518" Four t" Spots of Asphalt Roofing Cement Figure 14: Mansard or Steep -Slope Pattern, Oakridge MEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization#32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 D- 7.,r in 6.3.1.5 WeatherGuard" HP: N34 cb,% E 5e• E!< asif4 txpasi il6a de 5 53$ pL:g. Expo !666 de 5 61 pu1� Figure 15: 6 -Nail Pattern, WeatherGuard HP 6Na] Pattern Esruema con 6 clavos Nail 6118" from bottom of shingle Clave a 6 118 puke. de la 5 518" Exposure 6 suae a ares parte inferior de la t0a Exposici6n de 5 5,B pulg. 1 Four 1" Spots of Asphalt Roof Cement Cuatro punlos de cemeuto de techo de asfa#o de t pulgada Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP (04 NEMO I etc. 6.4 HIP & RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire® Hip and Ridge Shingles with Sealant and Dura Ridge" Hip & Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard" HP Hip and Ridge Shingles and ProEdge" Hip & Ridge Shingles require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization X32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R1S Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 Dee -4-4: in U(4 NEMO I etc. 6.4.1.1 Berkshire® Hip & Ridge with Sealant and DuraRidge® Hip & Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction E— Direcci6n del viento predominante Nails Clavos -\\ I "`YYY I I A I I IF— P GFg Ezgosure I xpsitidn de 8 paIq 4 4 Figure 17: Isometric View, Berkshire and DuraRidge 6.4.1.2 WeatherGuard® HP Hip & Ridge Shingles: Fig. Q q q Prevailing Wind Direction \ A Nails A 44 I I i I I I 1 AA, 1 j I I Expesum �y Figure 19: Isometric View, WeatherGuard HP Hip & Ridge Fig. B Top View Vista superior I1 H Nail 25/s' Clavo I • Owens Corning StweNail` + I I— (D g' c I ai vIc Iv I I E 12" Figure 18: Plan View, Berkshire and DuraRidge Fig. C Hip & Ridge Shingle Fastening Top View Nails Nails T' 1 �r sy Exposure Figure 20: Plan View, WeatherGuard HP Hip & Ridge NEMO ETC, LLC Evaluation Report 037940.02.12-R10 Certificate ofAuthorizotion #32455 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-RIS Owens Corning Asphalt Roof Shingles Revision 10: 08/15/2019 noon a nF to 6.4.1.3 ProEdge° Hip & Ridge Shingles: Prevailing Wind Direction Sealant Strip 6" Exposure Fasten 7112" Cover Exposed Fasteners with N Reof Cement Figure 21: Isometric View, ProEdge UN NEM@ I etc. Standard Fastening tt„ Pattern Y -•Z. t2' Sealant ,s+2" b" Exposure Figure 22: Plan View, ProEdge 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 90- MANUFACTURING I PLAN 11 TS: Contact the named CIA entity for information on which plants produce products covered by Florida Rule 61620-3 QA requirements. t QUALI Ty AssuRANCE ENTITY: PRI Construction Materials Technologies, LLC—QUA9110; 813 621-5777; bwilson@pricmt.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 037940.02.12-1110 Certificate of Authorization #32455 6T" EDITION (2017) FBG NON-HVHZ EVALUATION FL10674-R15 Owens Corning Asphalt Roof Shingles Revision 30: 08/15/2019 D- in -f in