FL #
FL17420-R4
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE -74021
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL1742 _94_COI OCR14004.4 2017 FBC Eva[ Report ProArmor final.pjf
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
1507.1.1
Date Submitted
09/30/2017
Date Validated
10/03/2017
Date Pending FBC Approval
10/04/2017
Date Approved
12/12/2017
Summary of Products
I
FL #
Model, Number or Name
( Description
17420.1
ProArmor
Synthetic underlayment for use with asphalt shingles in steep
slope roofing
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17420_84_II OCR14004.4 2017 FBC Eval Report ProArmor
final.pddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
II Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
E
1111 FL17420_R4 AE_QCR14004.4 2017 FBC Eval Report
ProArmor final.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyri ht 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter
455, F.S., please click here .
Product Approval Accepts:
RNNOW ® £tecM r
Credit Card
Safe
CREEK Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 6T" EDITION (2017)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued September 30, 2017
1 Owens Corning Parkway
Toledo, OH 43657
(800) 438-7465
www.owenscorning.com
Quality Assurance: Intertek Testing Services NA, Inc. (QUA1673)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
REFERENCES
Entity Report No.
Standard
Year
Intertek Testing Services NA Ltd. (TST1509) 102389161 COQ -002A
AC 188
2012
Intertek Testing Services NA Ltd. (TST1509) 102389161 COQ -003b
ASTM E 108
2011
Intertek Testing Services NA Ltd. (TST1509) 102389161 COQ -004
ASTM D 226
2009
PRI Construction Materials Technologies (TST5878) OCR -259-02-01
ASTM D 1970
2015a
PRODUCT DESCRIPTION AND APPLICATION
ProArmor'm A mechanically attached, synthetic underlayment consisting of a woven polypropylene
base with a non -woven polypropylene laminate on the topside of the underlayment, and
a coating on the back side (nominal weight = 2.15 Ib/100ft). The underlayment shall be
used an alternative to ASTM D 226, Type II roofing underlayments and has
demonstrated a minimum tear strength of 20 pounds when tested in accordance with
ASTM D 1970- The product is supplied in 9.2 -sq rolls with nominal dimensions of 4 -ft x
250.5 -ft. Unless otherwise noted, the following application details shall be followed for
New and Existing construction. See manufacturer's installation instructions for further
detail.
Roof Deck: The roof deck shall be constructed of closely fitted
wood sheathing for new or existing construction.
Plywood deck shall be installed in accordance with
FBC requirements. Roof decks shall have no more
than 1/8" gap at abutting joints.
Attachment method: Underlayment shall be attached in accordance with
the FBC Table 1507.1.1 and manufacturer's
installation instructions.
Allowable roof coverings: Mechanically attached roof systems as prescribed in
FBC Section 1507.1.1.
OCR14004.4 FL17420-R4 Page 1 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
GREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
OWENS CORNING ROOFING AND ASPHALT LLC
ProArmorTM
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Roof slope limitations shall be in accordance with FBC requirements.
7) The underlayment may be used as described in other current FBC product approval documents.
8) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
9) The underlayment shall not be installed over existing roof coverings.
10) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps
shall be staggered between courses in accordance with the manufacturer's application instructions.
11) The underlayment shall not be exposed on the roof deck for longer than 30 days.
12) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code 6`h Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
",%V11111111r1s
R
No 74021
: 3STATE OF UJ
:O�• �:
CERTIFICATION OF INDEPENDENCE
2017.09.30
���15:21:14
-04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT