Loading...
HomeMy WebLinkAboutEnergy CodeFORM R40512017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Tippins Residence Builder Name: Street: 19105 Okeechobee Road Permit Office: St. Lucie Cc my, RECEIVED City, State, Zip: Fort Pierce, FL, 34945 Permit Number. Owner. Tippins Residence Design Location: FL, Fort Pierce Jurisdiction: �I L •N9 v2 County: St. Lucie (Fit rida Clirrte(e'2one ) T, Lugid t;taNn y, -•. �� 1. New construction or existing New (From Plans) 9. Wall Types (2536.1 sgft.) ---Insula,on - -Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1450.50 ft2 b. Frame - Wood, Exterior R=19.0 1085.60 fl2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3. d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2400.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 2400.00 ft2 6. Conditioned floor area above grade (ft2) 2400 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft' 7. Windows(248.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AH1 6 95 a. U-Factor. Dbl, U=0.4o 188A7 ft2 b. Sup: Attic, Ret: Attic, AH: Attic 6 75 SHGC: SHGC=0.20 b. U-Factor: Dbl, U=0.40 41.00 ft' 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.25 a'. Central Unit 29.4 SEER:16.00 c. U-Factor. Dbl, U=0.40 19.36 ft2 b. Central Unit 18.8 SEER:16.00 SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor. WA ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.465 ft. Area Weighted Average SHGC: - 0.210 14. Hot water systems 8. Floor Types (2400.0 sgft.) Insulation Area a. Natural Gas Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 2400.00 ft2 b. Conservation features EF: 0.600 b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.104 Total Proposed Modified Loads: 72.64 PASS Total Baseline Loads: 74.43 I hereby certify that the plans and specifications covered by Review of the plans and ST this calculation are in compliance with the Florida Energy specifications covered by this OFTHE v Code. calculation indicates compliance y'�,,,, r _ = r �• with the Florida Energy Code. PREPA E Y: Before construction is completed t DATE: _I this building will be inspected for compliance with Section 553.908 I hereby certify that this•building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. 001) WV. t�J OWNER/AGENT: � BUILDING OFFICIAL: DATE: /L1?o 4 1 X DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FILE COPY 1/28/2019 4:00 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Tippins Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2400 Lot # Owner Name: Tippins Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook Builder Name: Rotate Angle: 0 Street: 19105 Okeechobee Ro Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34945 New/Exisfing: New (From Plans) Comment: CLIMATE _ / Design Temp Int Design Temp Heating Design Dally Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VEROBEACH_MUNI 39 90 70 75 299 •62 Low BLOCKS Number Name Area Volume 1 AHU2 933 7761 2 AHU1 1467 13203 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Healed 1 Dining Room 255 2295 No 1 1 Yes Yes Yes 2 Bedroom 2 193 1737 No 1 1 1 Yes Yes Yes 3 Bath 2 60 540 No 0 1 Yes Yes Yes 4 Nook 135 1215 No 1 1 Yes Yes Yes 5 Utility Room 100 900 No 0 1 Yes Yes Yes 6 Kitchen 289 2601 Yes 0 1 Yes Yes Yes 7 Living Room 435 3915 No 2 1 Yes Yes Yes 8 Master Suite 288 2592 No 2 1 1 Yes Yes Yes 9 Bedroom 3 172 1376 No 2 1 1 Yes Yes Yes 10 Hall -Stairs 86 688 No 0 1 No Yes Yes 11 Bath 3 72 576 No 1 1 Yes Yes Yes 12 AH1• 9 81 No 0 1 No Yes Yes 13 WIC 56 448 No 1 1 Yes Yes Yes 14 Sitting Room 150 1200 No 2 1 Yes Yes Yes 15 Master Bath 100 800 No 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Dining Room 40.2 ft 0 255 iF _ 1 0 0 2 Slab -On -Grade Edge Insulatio Bedroom 2 29 ft 0 193 ft' ___ 1 0 0 1/28/2019 4:00 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab -On -Grade Edge Insulatio Bath 2 6 ft 0 60 ft' — 1 0 0 4 Slab -On -Grade Edge Insulatio Nook 12 ft 0 135 fN _ 1 0 0 5 Slab -On -Grade Edge Insulatio Utility Room 20 ft 0 100 ft' 1 0 0 6 Slab -On -Grade Edge Insulatio Kitchen 17 ft 0 289 ft' _ 1 0 0 7 Slab -On -Grade Edge Insulatio Living Room 37 ft 0 435 fl' _ 1 0 0 8Slab-On-Grade Edge Insulatio Master Suite 36 ft 0 288 ft' __ 1 0 0 9 Slab -On -Grade Edge Insulatio Bedroom 3 28 ft 0 172 ft' __ 1 0 0 10SIab•On-Grade Edge Insulatio Hall -Stairs 1 ft 0 86 ft' _ 1 0 0 11SIab-On-Grade Edge Insulatio Bath 3 9 ft 0 72 ft' 1 0 0 12SIab-On-Grade Edge Insulatio AH1 1 ft 0 9 fN — 1 0 0 13SIab-On-Grade Edge Insulatio WIC 7 ft 0 56 ft' _ 1 10 0 14SIab-On-Grade Edge Insulatio Sitting Room 31.2 ft 0 150 ft' 1 0 0 15SIab-On-Grade Edge Insulatio Master Bath 20 ft 0 100 ft' — 1 0 0 ROOF _ / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2684 ft' 0 ft2 Light 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2400 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Vented) Dining Room 30 Batt 255 ft' 0.1 Wood _ 2 Under Attic (Vented) Bedroom 2 30 Batt 193 ft' 0.1 Wood 3 Under Attic (Vented) Bath 2 30 Batt 60 ft' 0.1 Wood 4 Under Attic (Vented) Nook 30 Batt 135 ft' 0.1 Wood 5 Under Attic (Vented) Utility Room 30 Batt 100 ft' 0.1 Wood 6 Under Attic (Vented) Kitchen 30 Batt 289 ft' 0.1 Wood 7 Under Attic (Vented) Living Room 30 Batt 435 ft' 0.1 Wood 8 Under Attic (Vented) Master Suite 30 Batt 288 ft' 0.1 Wood 9 Under Attic (Vented) Bedroom 3 30 Batt 172 ft' 0.1 Wood 10 Under Aide (Vented) Hall -Stairs 30 Batt 86 ft' 0.1 Wood 11 Under Attic (Vented) Bath 3 30 Batt 72 fl' 0.1 Wood 12 Under Attic (Vented) AH1 30 Batt 98' 0.1 Wood _ 13 Under Attic (Vented) WIC 30 Batt 56 ft' 0.1 Wood 14 Under Attic (Vented) Sitting Room 30 Batt 150 fP 0.1 Wood 15 Under Alto (Vented) Master Bath 30 Batt 100 ft' 0.1 Wood �T2872019 4:00 PM Ene Gau e® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo Space w 1 N Exterior Concrete Block - Ext InQlning Room 4.1 14 0 9 0 126.0 ft' 0 0 0.6 0 -2 NE Exterior Concrete Block - Ext InDining Room 4.1 3 7 9 0 32.3 ft2 0 0 0.6 0 -3 E Exterior Concrete Block -Ext InSlllning Room 4.1 7 0 9 0 63.0 ft2 0 0 0.6 0 -4 W Exterior Concrete Block- Ext Indi]Ining Room 4.1 12 0 9 0 108.0 ft' 0 0 0.6 0 _S NW Exterior Concrete Block- Ext Indillning Room 4.1 3 7 9 0 32.3 ft2 0 0 0.6 0 -6 E Exterior Concrete Block- Fxd InsiBedroom 2 4.1 16 0 9 0 144.0 ft' 0 0 0.6 0 -7 S Exterior Concrete Block- Ext Ins0edroom 2 4.1 13 0 9 0 117.0 ft2 0 0 0.6 0 -8 S Exterior Concrete Block - Ext Insul Bath 2 4.1 6 0 9 0 54.0 ft' 0 0 0.6 0 -9 S Exterior Concrete Block - Ext Insul Nook 4.1 12 0 9 0 108.0 ft' 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ext Insliltility, Room 4.1 10 0 9 0 90.0 ft' 0 0 0.6 0 _ 11 W Exterior Concrete Block - Ext Instiltility Room 4.1 10 0 9 0 90.0 ft' 0 0 0.6 0 _ 12 W Exterior Concrete Block - Ext Insul Kitchen 4.1 17 0 9 0 153.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Ext Insblving Room 4.1 21 0 9 0 189.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block - Ext InsW4ng Roam 4.1 16 0 9 0 144.0 ft2 0 0 0.6 0 15 N Exterior Frame - Wood Master Suite 19 14 0 9 0 126.0 ft2 0 0.25 0.6 0 16 E Exterior Frame - Wood Master Suite 19 22 0 9 0 198.0 ft, 0.25 0.6 0 17 S Exterior Frame - Wood Bedroom 3 19 16 0 8 0 128.0 ft' 0 0.25 0.6 0 18 W Exterior Frame - Wood Bedroom 3 19 12 0 8 0 96.0 ft2 0 0.25 0.6 0 19 W Exterior Frame - Wood Bath 3 19 9 0 8 0 72.0 ft2 0 0.25 0.6 0 20 W Exterior Frame - Wood WIC 19 7 0 8 0 56.0 ft2 0 0.25 0.6 0 21 N Exterior Frame - Wood Sitting Room 19 6 0 8 0 48.0 fl2 0 0.25 0.6 0 22 NE Exterior Frame - Wood Sitting Room 19 3 7 8 0 28.8 ft2 0 0.25 0.6 0 23 E Exterior Frame -Wood Sitting Room 19 7 0 8 0 56.0 ft2 0 0.25 0.6 0 24 W Exterior Frame - Wood Sitting Room 19 11 0 8 0 88.0 ft2 0 0.25 0.6 0 25 NW Exterior Frame -Wood Sitting Room 19 3 7 8 0 28.8W 0 0.25 0.6 0 26 E Exterior Frame - Wood Master Bath 19 10 0 8 0 80.0 ft2 0 0.25 0.6 0 27 S Exterior Frame - Wood Master Bath 19 10 0 8 0 80.0 ft2 0 0.25 0.6 0 WINDOWS Orientation shown Is the entered. Proposed orientation. _ / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.4 02 N 20.7 ft2 1 ft 6 in 1 ft 4 in None None 2 NE 2 Vinyl Low-E Double Yes 0.4 0.2 N 10.0 ft2 1 ft 6 in 1 ft 4 in None None 3 NW 5 Vinyl Low-E Double Yes 0.4 0.2 N 10.0 ft2 1 it 6 in 1 ft 4 in None None 4 S 7 Vinyl Low-E Double Yes 0.4 0.2 N 15.0 ft2 1 ft 6 in 1 ft 4 in None None 6 S 8 Vinyl Low-E Double Yes 0.4 0.2 N 4A ft2 1 ft 6 in 1 ft 4 in None None 6 S 9 Vinyl Low-E Double Yes 0.4 0.2 N 24.6 W 1 ft 6 in 1 ft 4 in None None 7 W 11 Mnyl Low-E Double Yes 0.4 0.2 N 6.0 ft2 1 It 6 in 1 It 4 in None None _ 8 W 12 Vinyl Low-E Double Yes 0.4 0.23 N 19.4 ft2 1 ft 6 in 1 ft 4 in None None 9 W 12 Vinyl Low-E Double Yes 0.4 0.2 N 12.0 ft2 1 ft 6 in 1 ft 4 in None None 10 N 13 Vinyl Low-E Double Yes 0.4 0.25 N 20.5 ft2 6 ft 0 in 1 ft 4 in None None 11 N 13 Vinyl Low-E Double Yes 0.4 0.2 N 15.0 ft2 6 ft 0 in 1 ft 4 in None None 12 N 13 Vinyl Low-E Double Yes 0.4 0.2 N 15.6 ft2 6 ft 0 in 1 ft 4 in None None 1/28/2019 4:00 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Pro osed orientation. _ / V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 13 14 15 16 17 E 14 Vinyl Low-E Double Yes E 16 Metal Low-E Double Yes S 17 Vinyl Low-E Double Yes W 19 Vinyl Low-E Double Yes S 27 Vinyl Low-E Double Yes 0.4 0.25 N 20.5 ft2 2 ft 0 in 1 ft 4 in 0.4 0.2 N 31.2 ft' 1 ft 6 in 1 ft 4 in 0.4 0.2 N 15.3 ft' 1 ft 6 in 1 ft 4 in 0.4 0.2 N 4.4 ft' 1 ft 6 in 1 ft 4 in 0.4 0.2 N 4.3 ft- 1 ft 6 In 1 ft 4 in None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000389 2445.8 134.27 252.52 .289 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat/ None Electric Strip Heat/ None COP:1 27 kBtu/hr C0P:1 17 kBtu/hr 2 1 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit/ Split Central Unit/ Split SEER: 16 29A kBtu/hr cfm 0.7 2 SEER: 16- 18.8 kBtu/hr drn 0.7 1 sys#1 sys#2 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Can # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS / V # — Supply — — Return— Air CFM 25 CFM25 Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 _ 2 Attic 6 95 fP Attic Attic 6 75 ft' Attic 25 ft' Default Leakage AH1 (Default) (Default) 20 ft' Default Leakage Attic (Default) (Default) 1 1 2 2 1/28/2019 4:00 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY rWFrK1 IRT RFPnRT TEMPERATURES Programablre'Thermosta((t��Y Ceiling Fans: HeatinDec g Jan [)9 Feb r[[? �,] Mar A AApr € ay Jun 0(I [) Jul �q i 1 Aug X� 4 ] Sep Oct rr Venting L) Jan II ]) Feb L l Ix) Mar lhl May Jun [)Jul [[[ ]]1 Aug [) Sep Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Dining Room Default(8 lbs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 lbs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 lbs/sq.ft. ft2 ft 0.3 Nook Default(8 lbs/sq.ft. ft2 ft 0.3 Utility Room Default(8 lbs/sq.ft. ft2 ft 0.3 Kitchen Default(8 lbs/sq.ft. ft2 It 0.3 Living Room Default(8 lbs/sq.ft. ft2 ft 0.3 Master Suite Default(8 lbs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. ft2 ft 0.3 Hall -Stairs Default(8 lbs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 lbs/sq.ft. ft2 ft 0.3 AH1 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 lbs/sq.R ft2 ft 0.3 Sitting Room Default(8 lbs/sq.ft. ft2 ft 0.3 Master Bath Name: Rating Compant: A il:������:c�� • , .c•�� 1/28/2019 4:00 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 � J r 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Tippins Residence Builder Name: Street: 19105 Okeechobee Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34945 Permit Number: U Owner. Tippins Residence . Jurisdiction: w Design Location: FL, Fort Pierce 0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceilin ceiling/soffit Y9 the Insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor Insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cot neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind olpina and Virina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids I between fire sprinkler cover nlates and walls or ceilinns, I I a. In addition, Inspection of log walls shall be In accordance with the provisions of ICC-400. 1/28/2019 4:01 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 �.J0' r 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No, of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.2 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2400 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.400 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.210 14. Heating system: Capacity 44.0 c) Area 7c. 248.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Gas fired, natural gas EF 0.60 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: z0o -/ -zo! y, Address of New Home: 19105 Okeechobee Road City/FL Zip: Fort Pierce, FL 34945 1/28/2019 4:01:37 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1