HomeMy WebLinkAboutLoad calcs`P; optional Lead Calculation Heat Larger Than Air � , 2 SF x 3VA Living Only (2) Small appliance ckts 1500VA each Refrigerator @ 1500 Refrigerator @ 1500 Freezer @ 1500 Washing Machine @ 150D Dishwasher @ 1500 Disposal @ 1500 Min€Sewer@ 1500 Clothes Dryer @ 5000 Range @ 12DOO Water heater @ 45ti0 Fixed microwave @ 1.500 Vacuum @ 1500 Trash Compactor @ 1.5D0 Pool Heater @ `name plate' Spa @ 'name plate' Motors 746VA per HP Garage Door t]pener I 1) Total 2) First 10 KVA of general load @ 100% 3) Subtract line 2 from 1 4) Multiply fine 3 @ 40Y 5) Arid lines 2 and 4 S) 60/30arnp breaker for heat (10000) 7) 40/30am p breaker for heat (5000) sj Total heat --Add lines 6 and 7 9) Multiply line 3 @ 55% 10) Add lanes 5 and 9 11) Divide line 10 by 240 Summary. Line 3.0 is the total KW Line 11 is the total Amps t. 1'2, {iSeneratorSize Needed) —7.9 ,3�'� (Breaker size Needed)