Loading...
HomeMy WebLinkAboutCompaction Test :" In-Place Density Report Client: Project: &Associates, Inc. Permit#2007-0311 Renar Development Corp. 113-15-66-5434B Report Date: 8/13/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce Florida CA No.5950 Fort Pierce, FL 460 NW Concourse Place,Unit Port St.Lucie,FL 34986 Phone:772-878-0072 Test Results Optimum Maximum In Place In Place Probe Retest Test Soil Moisture Dry Density Moisture Dry Density Depth Percent Min Comp. Test# Of Date Proctor ID Method Classification N (pcf) N (pcf) (in) Compaction N Remark 328 8/7/20 20-223 A -- 10.5 113.0 9.8 109.3 12 97 95 Pass (Modified) 329 8/7/20 20-223 A -- 10.5 113.0 10.0 112.6 12 100 95 Pass (Modified) 330 8/7/20 20-223 A -- 10.5 113.0 10.8 109.2 12 97 95 Pass (Modified) 331 8/7/20 20-223 A - 10.5 113.0 10.5 110.4 12 98 95 Pass (Modified) 332 8/7/20 20-223 A - 10.5 113.0 11.4 110.7 12 98 95 Pass (Modified) 333 8/7/20 20-223 A - 10.5 113.0 10.7 111.3 12 98 95 Pass (Modified) 334 8/7/20 20-223 A -- 10.5 113.0 10.2 109.7 12 97 95 Pass (Modified) 335 8/7/20 20-223 A -- 10.5 1 113.0 12.4 1 110.2 12 98 95 Pass (Modified) Test Information Gauge Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician 328 Foundation: House Pad for Lot 117,312 Palm Breezes Drive.SW Corner -1.0 Top of Pad Troxler/T-3430/21330/ Tech,Port St.Lucie 329 Foundation:House Pad for Lot 117,312 Palm Breezes Drive.NW Corner -1.0 Top of Pad Troxler/T-3430/21330/ Tech,Port St.Lucie 330 Foundation:House Pad for Lot 117,312 Palm Breezes Drive.NE Corner -1.0 Top of Pad Troxler/T-3430 121330/ Tech,Port St.Lucie 331 Foundation:House Pad for Lot 117,312 Palm Breezes Drive.SE Corner -1.0 Top of Pad Troxler/T-3430/21330/ Tech,Port St.Lucie 332 Footings:House Pad for Lot 117,312 Palm Breezes Drive.W Side -2.0 Top of Pad Troxler/T-3430/21330/ Tech,Port St.Lucie 333 Footings:House Pad for Lot 117,312 Palm Breezes Drive.E Side -2.0 Top of Pad Troxler/T-3430/21330/ Tech,Port St.Lucie 334 Footings:House Pad for Lot 117,312 Palm Breezes Drive.N Side -2.0 Top of Pad Troxler/T-3430/21330/ Tech,Port St.Lucie 335 Footings:House Pad for Lot 117,312 Palm Breezes Drive.S Side -2.0 Top of Pad Troxler/T-3430/21330/ Tech,Port St.Lucie Remarks Comments Pass: Density Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as "Backscatter".Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. Ak-` In-Place Density Report Client: Project: &Associates, Inc. Permit#2007-0311 Renar Development Corp. 113-15-66-5434B Report Date: 8/13/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D 6938 Stuart, FL 34996 Fort Pierce Florida CA No.5950 Fort Pierce, FL 460 NW Concourse Place,Unit 1 Port St.Lucie,FL 34986 Phone:772-878-0072 X01%1I![)///I NN "''''ffffff s i � �. / N �:o.63911 i r ETA OF00. ,'a ref//r��A►��4, This item has been digitally signed and sealed by Branch Manager Dan J.Zrallack, P.E.on Aug 13, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.