HomeMy WebLinkAboutAPPROVED, Tamko Underlayment 30lbCREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer: TAMKO BUILDING PRODUCTS, INC.
P.O. Box 1404
Joplin, MO 64802
(417)624-6644
http:llwww-ta mkO -cQ'n
Quality Assurance: UL LLC (QUA9625)
SCOPE
'Category: Roofing
Subcategory: Underlayments
Code Sections: 1507.1.1
Properties: Physical properties
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6T" EDITION (2017)
Issued October 19, 2017
PRODUCT DESCRIPTION
TAMKOV ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated
Surfaced Roil Roofing with asphalt and coated on both sides with asphalt and surfaced with granules.
TAMKO@ ASTM Tile ASTM D 6380, Class M, Type it underlayment constructed from an organic felt saturated
underlayment with asphalt then coated on both sides with asphalt and surfaced with granules.
TAMKO@) Master ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated
Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. Far
use in non-HVHZ only
TAMKOR Moisture
Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane
a removable release film on the adhesive side and
Guard®
with a mineral surfacing and
removable selvedge release tape.
TAMKO@ No. 15 ASTM
ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKO@ No. 15 UL
ASTM D 226, Type I underlayment constructed from a non -perforated organic fell that is
Asphalt Saturated
saturated with asphalt.
Organic Felt
TAMKOO No. 3.4.ASTM
ASTM 0226, Type it underlayment constructed from a non -perforated organiq fett.that is
Asphalt S.ejiIprate d
saturated with asphalt.
Organic
TAMKO@) No. 30 UL
ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is
Asphalt Saturated
saturated with asphalt.
Organic Feit
TAMKO@ TW Metal and
Self -adhered, flexible, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane
Tile underlayment
with a polymer film on the surface and a removable release film on the adhesive side.
TAMKO®TW
Self -adhered, flexible, ASTM D 1970, rubberized asphalt sheet membrane with a
a removable release film on the adhesive side.
underlayment
polymer film an the surface and
TBP14001.4 FL12328-R8 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
RAM SCREEK TAMI{O BUILDING PRODCUTS, INC.
TAMKO Undertayments
TECHNICAL SERVICES, LLC
TAMKO@ TAM -FELT Alternate to ASTM D 226, Type l and Type II undertayment constructed from a non -
perforated organic felt that is saturated with asphalt.
APPLICATION METHOD
Installation shall be in accordance with the published manufacturer's installation instructions, the FBC, and the
requirements below.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be
checked for protruslon and corrected prior to undertayment application.
The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction, Plywood deck
shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting
joints.
The minimum application temperature shall be 50°F except as follows:
a) The minimum application temperature of TAMK08 TW Metal and Tile Underlayment and TAMKOO TW
Underlayment shall be 40'F.
bj The minimum application temperature of TAMKOO Moisture Guard® shall be 35°F.
The minimum roof slope shall be in accordance with FBC requirements except as follows:
a) The minimum slope of TAMKOO ASTM State Surfaced Roll Roofing shall be 2.12.
Underlayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shalt
exposure exceed 30 days.
Exception: TAMKO@ TW Metal and Tile Underlayment may be exposed for a maximum 90 days.
Self -adhering underlayments may be adhered to primed or unprimed plywood substrates in the non-HVHZ.
All roof coverings shall be mechanically fastened through the underlayment to the roof deck.
Allowable Roof Covenn s:
Metal Roof
Mineral
Wood
Asphatt
Panels and
Surfaced Roll
Shingles and
Slate
Clay and
Underlayment
Shingles
Shingles
Roofing
Shakes
Shingles
Concrets Tile
TAMKO@) ASTM State
Surfaced Roll Roofing
Y'
N
N
N
N
Y
TAMKO@) ASTM Tile
N
N
N
N
N
Y
Underlayment
TAMKO@) Master Smooth
Y'
N
N
N
N
N
TAMKOO Moisture Guard@)
Y
N
N
N
N
N
TAMKOO No. 15 ASTM
Asphalt Saturated Organic
Y
Y
Y
Y2
N
N
Felt
TAMKO® No. 15 UL Asphalt
Y
Y
Y
YZ
Y
N
Saturated Organic Felt
TAMKO@ No. 30 ASTM
Asphalt Saturated Qrganec
Y
Y
Y
Y
Y
Y
Felt
TAMKO@ No. 30 UL Asphalt
Saturated Organic Felt
Y
Y
Y
N
Y
N
TAMKO@ TW Metal and Tile
Underlayment
Y
Y
N
N
N
Y
TAMKOO TIN Underlayment
Y
Y
N
N
N
N
[TAAtIKO� T:AM-FELT
Y
N
N
N
N
N
Notes: 1] Open valley applications per 1507.2.9.2
2) Wood shingles only
TBP14001.4
FL12328-R8
Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 51 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid,
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
�� TAMKC BUILDING PRODCUTS, INC.
TAMKQ Underlayments
TECHNICAL SERVICES, LLC
L miTATioNs
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance in not within scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Contact the manufacturer when installing at temperatures below the minimum application temperature.
5] Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
6) All underlayments shall be installed with the roll length parallel to the eave, starting at the save, and lapped
in successive courses installed up the deck in a manner that effectively sheds water from the deck. End
laps shall be staggered between courses in accordance with the manufacturer's application instructions.
7] The underlayment may be used as described in other current FBC product approval documents.
8) The underlayment shall not be installed over existing roof coverings.
9) Contact the manufacturer regarding specific exposure limits for each underlayment.
10) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
TAP-192-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-193-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-214-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP-215-02-01
ASTM D 226
2009
PRI Construction Materials Technologies (TST6049)
TAP-216-02-03
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-217-02-01 REV
ASTM ❑ 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-218-02-01
ASTM D 226
2009
PRI Constriction Materials Technologies (TST6049)
TAP-219-02-01
ASTM D 226
2009
PRE Construction Materials Technologies (TST6049)
TAP-220-02-01
ASTM D 6380
2003(2013)
PRI Construction Materials Technologies (TST6049)
TAP-222-02-01
ASTM D 4869
2016
PRI Construction Materials Technologies (TST6049)
TAP-245-02-01
TAS 103
1995
ASTM D 4798
2011
PRI Construction Materials Technologies (TST6049)
TAP-311-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-319-02-01.1
ACC 188
2012
PRI Construction Materials Technologies (TST6049)
TAP-387-02-01
ASTM D 1970
2015a
PRI Construction Materials Technologies (TST6049)
TAP-388-02-01
ASTM D 1970
2015a
UL LLC (TST9628)
13CA12269
ASTM D 226
2009
TSP14001.4 FL12328-R8 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shalt notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
TAMKO BUILDING PRODCUTS, INC.
TAMKO Underlayments
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, a Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
,F�►lilfiillffi
``ttG�P�tY R..
No 74021
Q STATE OF :4J
fff+r111110
CERTIFICATION OF INDEPENDENCE
2017.10.19
12:15:58
-04'00'
Zachary R. Prest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CRFEK Technical Services, LLC is not owned, operated, oreontro]]ed by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E, does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not crave, nor will acquire, a financial interest in any other endty involved in the approval process of the product.
END OF REPORT
TBP14601.A FL12328-RB Page 4 of 4
This evaluation report is provided for State of Florida prod uot approval under Rule 61020-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.