Loading...
HomeMy WebLinkAboutDigitally Signed CCI Generic 1-6 01-20-20 - ESS 07-14-20 (1)FBC APPROVED PRODUCTS LIST PRODUCT CATEGORY SUB CATEGORY STRUCTURAL COMPONENTS ROOF DECK STRUCTURAL COMPONENTS I STRUCTURAL WALL STRUCTURAL COMPONENTS I FLOOD VENT EXTERIOR DOORS I SWINGING EXTERIOR DOORS I SWINGING EXTERIOR DOORS I ROLL -UP EXTERIOR DOORS I ROLL -UP WINDOWS I SINGLE HUNG EXTERIOR DOORS I ROLL -UP EXTERIOR DOORS I ROLL -UP EXTERIOR DOORS I ROLL -UP MANUFACTURER CAROLINA CARPORTS, INC. 26 Gauge AG Panel CAROLINA CARPORTS, INC. 26 Gauge AG Panel CRAWL SPACE DOOR SYSTEMS, INC. 16x8 Flood Vent ELIXIR DOOR AND METAL COMPANY Series 402-14 ELIXIR DOOR AND METAL COMPANY Series 407 ASTA INDUSTRIES INC. Model 203 (12' Max. Width) CAROLINA CARPORTS, INC. Steel Roll Up Sheet Door (12' Max. Width) MI WINDOWS AND DOORS Model 185 SH CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door - 8' Wide CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door - 10' Wide CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door - 16' Wide MAXIMUM ALLOWABLE WIND SPEED PARTIALLY OPEN ENCLOSED ENCLOSED 180 180 180 180 180 N/A N/A N/A 139 N/A 165 N/A 180 N/A 158 N/A 175 N/A 180 N/A 180 N/A 1 155 180 N/A 138 147 TABLE 1 RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR MAXIMUM PURLINS, AND POSTS OR GIRTS WIND ULTIMATE NOMINAL POST / RAFTER (INCHES) RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 110 TO 150 89 TO 116 5.0 6 6 1 C 151 TO 180 117 TO 139 4.0 6 6 NOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 gauge hat channel roof purlins. 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27° (1.5:12 to 6:12 pitch). Spacing requirements for other roof heights and/or slopes may vary. GROUND ANCHOR SCHEDULE ULTIMATE WIND SPEED (mph) METAL CARPORT INSTALLATION PLANS 110 120 130 140 150 160 170 180 AND DETAILS AND FRAMING AND FASTENER SPECIFICATIONS 174 QA APPROVAL EXPIRATION No. & DATE DATE FL6596.1-R5 04/05/27 10/10/17 FL6702.1-R5 03/14/27 10/10/17 FL29622.1 09/01/20 05/15/19 F L 17996.3-R 1 09/14/20 01/29/18 9 F L 17996.5-R 1 09/14/20 01/29/18 FL8888.1-R5 12/31/20 10/07/17 z 0 m FL16806.1-R4 11/11/20 06/18/19 F L 17499.1-R5 10/17/23 03/27/19 FL16806.2-R4 11/11/20 06/18/19 FL16806.4-R4 11/11/20 06/18/19 28 FL16806.3-R4 11/11/20 06/18/19 30 MAXIMUM ALLOWABLE WIND SPEED PARTIALLY OPEN ENCLOSED ENCLOSED 180 180 180 180 180 N/A N/A N/A 139 N/A 165 N/A 180 N/A 158 N/A 175 N/A 180 N/A 180 N/A 1 155 180 N/A 138 147 TABLE 1 RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS AVERAGE FASTENER SPACING ON -CENTERS ALONG RAFTERS OR MAXIMUM PURLINS, AND POSTS OR GIRTS WIND ULTIMATE NOMINAL POST / RAFTER (INCHES) RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 110 TO 150 89 TO 116 5.0 6 6 1 C 151 TO 180 117 TO 139 4.0 6 6 NOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 gauge hat channel roof purlins. 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27° (1.5:12 to 6:12 pitch). Spacing requirements for other roof heights and/or slopes may vary. GROUND ANCHOR SCHEDULE ULTIMATE WIND SPEED (mph) METAL CARPORT INSTALLATION PLANS 110 120 130 140 150 160 170 180 AND DETAILS AND FRAMING AND FASTENER SPECIFICATIONS 174 12 138 14 16 30" Anchor Detail1D 157 180 9 18 20 22 48" Anchor Detail 1C 172 z 0 m 24 26 28 60" Anchor 133 30 Detail1C DETAILS 1 C AND 1 D SHOWN ON SHEET 4 OF 6 NOTES: 1. DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET: A. PRODUCT SHALL HAVE A VALID FBC PRODUCT APPROVAL. B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION REQURIEMENTS. 2. FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE SUBSTITUTED PRODUCT. GENERAL NOTES: 1 THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. 2. THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. 3, ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. 4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE LOCATION OF THE BUILDING WITHIN THE STATE OF FLORIDA. 5. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6 -W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION. SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. 8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LDT 1/2" x 5" OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. 9. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SIXTH EDITION (2017) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC SIXTH EDITION (2017) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED. 11. 14 GA FRAMING: 2-1/2" x 2-1/2" TUBE STEEL (TS) WITH 2-1/4" x 2-1/4" TS NIPPLES. 12 GA FRAMING: 2-1/4" x 2-1/4" TS WITH 2" x 2" TS NIPPLES. 12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF OPENINGS SET WITHIN 1 -FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1) FLOOD VENT PER EVERY 305 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6. FOR CONSTRUCTION IN THE STATE OF FLORIDA PREPARED FOR: CAROLINA CARPORTS, INC. P.O. BOX 1263 DOBSON, NORTH CAROLINA 27017 PREPARED BY: BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Certificate of Authorization No. 00005492 THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017). THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING CODE. BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Certificate of Authorization No. 00005492 Digitally signed by Thomas Thomas Bechtol Bechtol Date: 2020.07.14 14:17:08 -04'00' Thomas Bechtol, P.E. President / Principal Engineer Thomas Bechtol, P.E., State of Florida, Professional Engineer, License No. 38538 This item has been digitally signed and sealed by Thomas R. Bechtol, P.E. on the date indicated here. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA FIELD TE 01/20/20 BECHTOL ENGINEERINGE1L, mkb oJ`N° NTS AND TESTING, Inc. ° tb G20001 CONSULTING GEOTECHNICAL. ENVINoNMENTAL, AND MATERIALS TESTING ENGINEERSCe,�fi�a,e4A.-n-No.°°"°5492 "'c" TB SHEET 1 OF 6 BOW FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF BOW FRAME RAFTER UTILITY BUILDING - HORIZONTAL ROOF FLOOD VENT (As applicable) — ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) G—s' ENCLOSED LENGTH VARIES TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) —6' 6„ ENCLOSED LENGTH VARIES TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION Ed TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT -VERTICAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) ENCLOSED LENGTH VARIES TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BECHTOL ENGINEERING AND TESTING, INC. 605 WEST NEW YORK AVENUE DELAND, FLORIDA 32720 Certificate of Authorization No. 00005492 Digitally signed by Thomas Thomas Bechtol Bechtol Date: 2020.07.14 14:15:02 -04'00' Thomas Bechtol, P.E. President / Principal Engineer Thomas Bechtol, P.E., State of Florida, Professional Engineer, License No. 38538 This item has been digitally signed and sealed by Thomas R. Bechtel, P.E. on the date indicated here. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. CAROLINA CARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA TYPICAL BOW RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION FIEM TE. o1/20/20 BECHTOL ENGINEERING D mkb ALE. NTS NOT TO SCALE NOT TO SCALE NOT TO SCALE AND TESTING, Inc. EC" ED tb No G20001 CONSULTING GEOTECHNICAL, ENVIRONMENTAL, AND MATERIALS TESTING ENGINEERS De,�-14A��o� No.DDODW2 'ROVED TB SHEET 2 OF 6 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 2 12 4 a3 24" 16 GA U -CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4" SDF's AT EACH END (4 PER BRACE) x cD 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER 'a >24' TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER O AS SHOWN ON THIS SHEET 4 TYPICAL NOT TO SCALE LENGTH VARIES DEPENDING ON NI IRARFR AND SPA(:INr ()F RAFTFRS TYPICAL RAFTER/POST FRAMING PLAN - BOW FRAME NOT TO SCALE 12' MAX. OPENING FOR ROLL -UP DOOR WITH STRUCTURAL HEADER 10" (TYPICAL) 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 0� 1":::::13 41 a 3 24" 16 GA U -CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4" SDF's AT EACH END (4 PER BRACE) c� w 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER >24' TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER I- AS SHOWN ON THIS SHEET TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOX EAVE - HORIZONTAL ROOF NOT TO SCALE LENGTH VARIES DEPENDING ON NI IMRFR AND SPA(:IN(' nF RAFTFRS TYPICAL RAFTER/POST FRAMING PLAN - BOX EAVE NOT TO SCALE SEE TABLE 1/.—OPENING FOR SWINGING SHEETDOOR WITH NON-STRUCTURAL 1OF6 HEADER OPENING FOR WINDOW WITH NON-STRUCTURAL HEADER TYPICAL SIDE WALL OPENINGS FRAMING PLAN AND WINDOW RAIL (Also AND to End Walls) NOT TO SCALE OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOW NOT TO SCALE 12' MAX. OPENING FOR ROLL -UP DOOR WITH NON-STRUCTURAL HEADER SEE TABLE 1 SHEET 1 OF 6 OPENING FOR SWINGING DOOR WITH NOW STRUCTURAL HEADER T— 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO PURLINS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 1-1/2" 18 GAUGE FURRING CHANNEL (PURLIN) 0 AS SHOWN ON THIS SHEET f— iL TYPICAL INTERIOR RAFTER/POST FRAME SECTION - VERTICAL ROOF NOT TO SCALE 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48" O.C. X24" 16 GA U -CHANNEL BRACE = FASTENED TO RAFTER WITH w (2) #12-14 x 3/4" SDF's AT = EACH END (4 PER BRACE) W SEE TABLE 1 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER 1 OF 6 >24' TO 30' RAFTER SPAN REQUIRES ATRUSSED RAFTER 0 AS SHOWN ON THIS SHEET f— iL TYPICAL INTERIOR RAFTER/POST FRAME SECTION - VERTICAL ROOF NOT TO SCALE 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48" O.C. TYPICAL POST/RAFTER FRAMING PLAN - VERTICAL ROOF NOT TO SCALE TYPICAL END WALL OPENINGS POST/RAFTER FRAMING PLAN NOT TO SCALE OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOX EAVE NOT TO SCALE TYPICAL BOW RAFTER GABLE END FRAMING PLAN NOT TO SCALE 6" SEE MAXIMUM TABLE 1 4' O.C. FOR SHEET VERTICAL 1 OF 6 PANEL w 3 a TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN NOT TO SCALE 24" 16 GA U -CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING SCREWS AT EACH END (4 PER BRACE) ROOF EXTENSION OPTION MAIN STRUCTURE STANDARD LEAN-TO OPTIOf TYPICAL LEAN-TO OPTIONS FRAMING PLAN (BOTH OPTIONS SHOWN) NOT TO SCALE (BOX EAVE RAFTER SHOWN, ONLY STANDARD LEAN-TO IS APPLICABLE TO BOW FRAME RAFTER) 24" 16 GA U -CHANNEL BRACE (5' TO T POST) 48" 16 GA U -CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 30° Tn AAAV AG- CDnIKA WnDl7nK17AI LD 3 LEAN-TO FRAMING PLAN NOT TO SCALE 11 Ir SEE TABLE 1 SHEET 1 OF 6 3 4 LENG VARIES DEPENDING ON NUMBER AND SPACING OF RAFTERS TYPICAL POST/RAFTER FRAMING PLAN - VERTICAL ROOF NOT TO SCALE TYPICAL END WALL OPENINGS POST/RAFTER FRAMING PLAN NOT TO SCALE OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOX EAVE NOT TO SCALE TYPICAL BOW RAFTER GABLE END FRAMING PLAN NOT TO SCALE 6" SEE MAXIMUM TABLE 1 4' O.C. FOR SHEET VERTICAL 1 OF 6 PANEL w 3 a TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN NOT TO SCALE 24" 16 GA U -CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING SCREWS AT EACH END (4 PER BRACE) ROOF EXTENSION OPTION MAIN STRUCTURE STANDARD LEAN-TO OPTIOf TYPICAL LEAN-TO OPTIONS FRAMING PLAN (BOTH OPTIONS SHOWN) NOT TO SCALE (BOX EAVE RAFTER SHOWN, ONLY STANDARD LEAN-TO IS APPLICABLE TO BOW FRAME RAFTER) 24" 16 GA U -CHANNEL BRACE (5' TO T POST) 48" 16 GA U -CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 30° Tn AAAV AG- CDnIKA WnDl7nK17AI LD 3 LEAN-TO FRAMING PLAN NOT TO SCALE 4" MINIMUM INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT ANCHOR OR 1/2" x MINIMUM 5-1/2" EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6" OF EACH RAFTER POSTS ALONG SIDES AND EVERY END WALL POST ALONG END WALL SECTIONS MINIMUM INIMUM 2-1/2" EMBEDMENT a MONOLITHIC CONC. FOOTING (2500 PSI MIN.) REINFORCED WITH 2 45's CONTINUOUS CONCRETE BASE RAIL ANCHORAGE A Not To Scale DRILL 5/8" HOLE THROUGH THE 2" WASHERS BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2" DIAMETER �TS CONTINUOUS LT THROUGH-BOBASE RAIL (SEE GROUND ANCHOR MINIMUM 4" SCHEDULE, SHEET 1 OF 6, FOR REQUIRED ANCHOR) — CONTINUOUS 4" CONCRETE PAVEMENT EYE ANCHOR— S CONCRETE BASE RAIL ANCHORAGE I EE Not To Scale (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL 1B) TS TRUSSED RAFTER CHORD, OR NON-STRUCTURAL HEADER TS END POST OR DOOR/ / WINDOW FRAME POST C TS BASE/WINDOW RAIL OR NON-STRUCTURAL HEADER (12 GA IF ROLL -UP DOOR FRAME) 2"x2"x2" 16 GA ANGLE CLIP SECURE TO POST (EACH SIDE) AND RAFTER CHORD/RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP OR BOTTOM, (2) ON SIDE NOTE: AT ROLL -UP DOOR OPENINGS, POST SHOULD BE FLUSH WITH RAIL END. CLIP POST TO RAIL ONLY ON SIDE OPPOSITE THE OPENING. POST TO RAIL, TRUSS CHORD, OR NON-STRUCTURAL HEADER CONN. DETAIL Not To Scale INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT ANCHOR OR 1/2" x MINIMUM 5-1/2" EXPANSION ANCHOR DRILL 5/8" HOLE THROUGH THE THROUGH BASE RAIL WITHIN 6" OF EACH BASE RAIL AND SECURE TO RAFTER POSTS ALONG SIDES AND EVERY END ANCHOR EYE WITH 1/2" DIAMETER WALL POST ALONG END WALL SECTIONS THROUGH -BOLT IN. 6" �II� W �f��i/fillq�l ]q�7�1q�11 MINIMUM 4" CONTINUOUS 4" CONCRETE PAVEMENT 11 IB�CONCRETE BASE RAIL ANCHORAGE Not To Scale (OPTIONAL - OPEN CARPORTS ONLY) 24" 16 GA U -CHANNEL BRACE (5' TO 7' POST) 48" 16 GA U -CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 45" TO MAX. 60° FROM HORIZONTAL NIPPLE TO\ 3/16" RAFTER TS RAFTER 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDF's RAFTER POST BOX EAVE RAFTER/POST DETAIL �~ Not To Scale TS RAFTER POST 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO POST AND BASE RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP, (2) ON SIDE CONTINUOUS BASE RAIL 5 END POST/BASE RAIL CONN. Not To Scale TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE WASHERS TS CONTINUOUS BASE RAIL EYE ANCHOR 5/8" ROD 48" LONG WITH 6" HELIX OR 5/8" ROD 60" LONG (SEE GROUND ANCHOR WITH 7" HELIX, SCHEDULE, SHEET 1 OF 6, AS APPLICABLE FOR APPLICABILITY) C,�_BAtSnE RAIL DEEP ANCHORAGE TS BOW RAFTER NO SCREWS REQUIRED IN BOW BEND DRILL 5/8" HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2" DIAMETER THROUGH -BOLT TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE 2" WASHERS TS CONTINUOUS BASE RAIL EYE ANCHOR U (SEE GROUND ANCHOR 5/8" ROD 30" LONG SCHEDULE, SHEET 1 OF 6, WITH DBL 4" HELIX FOR APPLICABILITY) 8vBASE RAIL ANCHORAGE Not To Scale 24" 16 GA U -CHANNEL BRACE (5' TO 7' POST) 48" 16 GA U -CHANNEL BRACE (8' TO 14' POST) 9-1/2"r3" BRACE ANGLE SHALL BE MIN. 45" TO MAX. 60" FROM HORIZONTAL NIPPLE TO 3/16" BASE RAIL 6" 6" LONG TS NIPPLESECURE RAFTER AND POST TO NIPPLE WITH (4) #12-14 x 3/4" SELF -DRILLING FASTENERS BOW RAFTER/POST DETAIL F Not To Scale TS POST 2" x 2" x 2" 16 GA ANGLE CLIP SECURE TO POST AND TOP OF HEADER, OR BOTTOM OF WINDOW RAIL/GIRT WITH (4) #12-14 x 3/4" SDF's (2) ON TOP OR BOTTOM, (2) ON SIDE TS NON-STRUCTURAL HEADER TS WINDOW RAIL OR GIRT FOR VERTICAL SIDING OPTION NON-STRUCTURAL HEADER, WINDOW RAIL, OR GIRT TO POST CONN. DETAIL Not To Scale 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDF's RAFTER POST TS CONTINUOUS BASE RAIL POST/BASE RAIL CONN. DETAIL Not. To Scale 2"x2"x2" 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 3/4" SDF's, (2) ON BOTTOM, (2) ON SIDE OR 2"x4" 16 GA PLATE SECURE TO EACH SIDE OF TS END POST – POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" SDF's, A (2) ON POST, (2) ON RAFTER OENDPOST/RAFTER CONN. DETAIL Not To Scale 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's (2) ON TOP, (2) ON SIDE RAFTER POST 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP, (2) ON BOTTOM GABLE RAIL GABLE RAIL TO RAFTER POST CONNECTION DETAIL 11 A Not To Scale 2-1/4" FOR 12 GA FRAMING 2-1/2" FOR 14 GA FRAMING 16 GAUGE U -CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14 x 3/4" SDF'S AT EACH END (4 PER BRACE) BRACE SECTION Not To Scale NIPPLE DBL. HE 5 NIPPLE EACH WITH x 3/4" -LING FASTENERS GA TS POST RAFTER POST/DBL. HEADER DETAIL Not To Scale 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3/4" SI TOP AND BOTTOM i 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP, (2) ON BOTTOM —6" LONG TS NIPPLE SECURE RAFTER AND POST TS GABLE RAIL TO NIPPLE WITH (4) #12-14 x 3/4" SELF -DRILLING FASTENERS TS RAFTER POST GABLE RAIL TO RAFTER POST CONNECTION DETAIL I I Not To Scale 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SDF SPACED NOT MORE THAN 48" O.C. 26 GA. METAL ROOF PANEL TS RAFTER ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) Not To Scale FTER POST VG TS NIPPLE RE WITH (4) #12-14 x 3/4" DRILLING FASTENERS DOUBLE TS HEADER NIPPLE TO DBL. HDR. RAFTER POST/HEADER DETAIL Not To Scale NIPPLE TO 3/16" RAFTER � TS RAFTER 12" LONG TS NIPPLE. SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDF's, 24" 16 GA U -CHANNEL BRACE (5' TO 7' POST) 48" 16 GA U -CHANNEL BRACE (8' TO 14' POST) BRACE ANGLE SHALL BE MIN. 45° TO MAX. 60° FROM HORIZONTAL TS LEG POST TS RAILS 169:7_F9� L1P 6" LONG TS NIPPLE SECURE WITH (4) 412-14 x 3/4" SDF's TS RAFTER POST SIDE EXTENSION RAFTER/POST DETAIL 12 Not To Scale TYPICAL FLOOD VENT FRAMING PLAN NOT TO SCALE SEE GENERAL NOTE No. 12, SHEET 1 OF 6. 6" LONG TS NIPPLE SECURE EACH WITH (4) #12-14 x 3/4" SELF -DRILLING FASTENERS 12 GA TS POST TS BASE RAIL 3/16" NIPPLETO BASE RAIL RAFTER POST/BASE BASE RAIL CONNECTION DETAIL Not To Scale TS RAFTER POST 2"x4" 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF POST/RAFTER CONNECTION WITH (4) #12-14 x 3/4" SDF's, (2) ON POST, (2) ON RAFTER —TS LEAN-TO RAFTER 2"x2"x2" 16 GA ANGLE CLIP SECURE TO POST AND RAFTER WITH (4) #12-14 x 3/4" SDF's, (2) ON RAFTER, (2) ON POST POST / LEAN-TO RAFTER CONN. DETAIL 1 3 Not To Scale VERTICAL SIDE OPTION SEE TABLE 1 OPENING FOR SWINGING DOOR SHEET WITH NON-STRUCTURAL HEADER 1 OF 6 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING 6" f~ FASTENER SPACED NOT MORE THAN 48" O.C. GIRTS d GIRTS (Typical) q a s � � (Typical) 1 a � \ 12' MAX. OPENING FOR ROLL -UP DOOR WITH 6 5 a NON-STRUCTURAL HEADER a a UPA- A,a a TYPICAL END WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN NOT TO SCALE BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL SIDES TYPICAL SIDE ELEVATION NOT TO SCALE ROLL -UP DOOR SWINGING DOOR !Ac nn Hl Klel !Ae—ii—KI-1 TYPICAL END ELEVATION NOT TO SCALE rOPENING FOR SWINGING DOOR WITH NON-STRUCTURAL HEADER TYPICAL POST/RAFTER/GIRT FRAMING PLAN NOT TO SCALE BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL SIDES TYPICAL SIDE ELEVATION NOT TO SCALE ROLL -UP DOOR SWINGING DOOR /Ac —H—ki-I /Ac �nnlir�4.la\ TYPICAL END ELEVATION NOT TO SCALE g q SEE TABLE 1dE 8 5 gqa q q 6 3 3 SHEET �1OF6 2 ej 12' MAX. OPENING FOR 3 10 ROLL -UP DOOR WITH a 3 a 5 STRUCTURALHEADER q q OPENING FOR WINDOW WITH NON-STRUOT=OHEADER LENGTH VARIES DEPENDING ON NUMBER AND WINDOW RAIL AND SPACING OF RAFTERS (Also applicable to End Walls) TYPICAL POST/RAFTER/GIRT FRAMING PLAN NOT TO SCALE BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL SIDES TYPICAL SIDE ELEVATION NOT TO SCALE ROLL -UP DOOR SWINGING DOOR /Ac —H—ki-I /Ac �nnlir�4.la\ TYPICAL END ELEVATION NOT TO SCALE