Loading...
HomeMy WebLinkAboutENGINEERING DOC Headquarters Im ANMailing 11345 U.S. Highway 1 WINEFRINGv PO Box 78-1377 Sebastian, FL. 32958 Sebastian, FL. 32978 Orlando 2;4 M AND TESTINO Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.#5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: June 26, 2020 KSM JOB#: 202814-2d/DJ/jo PERMIT#: S LC �CEIVED NUC# 404 ° � CONTRACTOR: Pauley Construction 4uc Model: MC-1 Elite JOB LOCATION: 8310 Andrews Avenue JUL 0 6 2020 uc Serial#: 31404 Fort Pierce, Florida ST. Lucie County, Permitting ITEM TESTED: Compacted Foundation Fill-Barn Pad TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE(P.C.F) COMPACTION 1. S.W. 0" - 12" 40+ 110.3 114.2 96.6% 2. N.W. 112.5 98.5% 3. Center 111.7 97.8% 4: N.E. 111.4 97.5% 5. S.E. 112.5 98.5% Soil Description: W 116.0 I I I I I Brown Silty Sand E i 115.0 -I—• _ I_ _ I _ _I _ I _ I _ In Place Moisture: G I I I I I 9.6% H I I I I I I T Proctor Optimum Moisture: 114.0 —j — j- — 11.0% P Proctor Max. Dry Density: P.C.F. C 114.2 113.0 —.._.I—. —.I.—.._�._..�.._ .�...—... F @ Test Locations the Density& I I I I I Penetrometer readings indicate the 112.0 i — Degree of Compaction Meets Minimum Requirement R I I I I I for Staked Foundation 111.0 Respectfully Sub 8 9 10 11 12 13 14 Moisture-%of Dry Weight Disclaimer: Contractor is responsible to maintain ��O •, �� the tested area in the condition that KSM completed the indicated passed compaction test. •$�439 � KSM is not responsible if the tested area has been tL9; f S1 ��or- l� altered from the approved inspected condition. V.P.o{trimpAering```, PE#81439 6/29/2020 Email to: 1p607@aol.com Proudly Serving Florida since 1990