Loading...
HomeMy WebLinkAboutBuilding PlansE 0 F —R —OR t4 —V—V —v— V — V — _ 53 2.5"-- t✓j 4j)V PR)4I jV-•-M -- $I j 2"-- WIN IN ER 2"-- 514(JfsP4ER 2.5"-- (q) RETOR06 0 0 R I ► R LIED I 1 RBtER 1 I I all 33 rFi I;L'% R 6 A CEPT14 I I u I ` R X 351 )2!LF 51 &[ C 5Q FT R D1-=PT14 O C s i 1 / B s rusr W11 4 FO&TER Ez�va�a-r9A7r #Z 8asur�JW6 1c717iE c> q arm AtD.210 (c� IE COPY iInnI''��II��\�'W VV V EVIEWEi) ibF CODE COMPLIANCE ST. soc ® � POOL SPECIFICATIONS Max Width I(Pt Max Length 35� Min Depth =Co`= Max Depth 6; Perimeter jpa.= Area 64t1=T Elevation FIOLD SJr Dirt from Exc. LFAIIF- Returns Lf Vac Stub %/E$ Cleaner Other Plumbing LF-D L'st? 3�LFR Fill Line NC= Overflow NO Tile as X a' Step Tile YE.5 Cantilever FVO Bullnose YE`j Raisebean(s) - - Lightc> »sr sJ Transformer (e�}P.D PUO =�atw7 p d Jbox 3 Timerp Automatic Controls j-AVrEL?Fi{f� '7JLf3?l�% PFfosl�� Patio Type ID4I/ R& Sq.Ft. $18!6QF7- Color away> Rj CNd(GJ Existing A30 sq. Ft. Footers YL-6 vv/steel #5 YES NO Termite Treat K) C'g Interiorfinish GEM Pump 'PEA?rfi41R H.P. V3$06c:l, Chlorinator YES NO TCgZ> 6N4. - Bench YEJ Handrail X)0 Gallons I& 100 Tumover Time Hrs. 5Mins. Cleaning Kit DELO A`E Heater IR4 '2,e I+{i�or✓$'�$iYt3 Foimboard Survey QDS NO FOOTER Final Survey YES NO - - Compaction YES NO _ BAZJ j CQMMENT-; d ALt. AIa F VCF tk 6ATE,.a` JOB SITE 2,4 vto � y�(p1,0 J c A YESc NEg 6-7T-kVD%,4d tLrER FT, PI E CCI FL 9 a CONTRACTOR JM FORM & STEEL INCORPORATED dba JM CUSTOM POOLS INCORPORATED #772-486 L c #C1 5$LI56 06-09-2020 X21 M. Randall Rodgers, P.E FL Lic. No. 68212 1801 Hazelwood Drive Ft. Pierce, FL 34982 PH: (772) 201-1634 NOTE ROM CRATE a BRICK YC PER FL MN SLOPE IW11 POW HIM FROM MAIN COPING OM & ATTACHeE WHENAF HAUX. POOL UNIP lHFN E//PIW1G PaGL 6':6- TU ` ','..:. •.�':mot < -PQoi construction complies with FBC 2017 ANSI-7 ANSI-15 GRTTE SHALL BRICK PAVER PATIO BE S-TURED IN :. ater Barrier Max ply8ft/sec as per FBC 2017-R4501 it3 >, CUSTOM POOLS THAT TOOLS INNS 41¢' TYP. WALL-3,000 PSI GUNfIE .`,',. `. r •,a "�. JM -fool Barrier to comply with Section R4501.17-6th edition FBC �, REouITTm -Skimmers comply with F8C 2017-R4501 21 2 FOR REMOVAL - srm.-ra FORM -Soil bearing capacity assumed 2 000psi 095% compaction OR KRAFT WALL -Equipment foundation 3'x7' conc...slab min 3 5" thick our in 3,000 ooR12 —P 'TRENCH DRAIN GUNNE I3 0 FOR O.C.B.W. • • CPC 14 5 8 4 5 6 place or approved Hurricane Rated recast equipment OdS NOTE FOR DEPTHS PP PP 1; GREATER THAN 6' ADD -Water Heating equipment to comply with FBC 2017-R4501 P°� , .; - ' ` (1)I3 OOVE BAR 06• G.C. PAVERS GRAVEL B t �r TO PUMP 12 TYP. WALL SECTION & WELL POINT FOOTER DETAIL (ND SCALE) (NO SCALE) 18 CO PIPER 7 AD G1m WHEN PROMIDED DECK 1 ROW OF WATERLINE TILE SHALL BE AT 20" MAX PRESSURE GAUGES INSTALLED I ON HEATER FILTER BELOW THE FILTER PUMP FOR FINAL INSPECTION CHLORINATOR IT IT THU HORIZONTAL INSTALL » ZOI N MAXIxaTr WATERLINE Pull w/ � a 3 —6 6.-0» t v LEVEL n --T 1 :13EW. 6� 6' THICK 18' Ia G E% BY-PASS HEATER 3pMT ( am FLOOR ORS >dAN_Ll_ VERTICAL WWe3t Vacuum (In HHe 1.13 Pressure (PSI) 231 - Feet Of Headd Feet Of Hand THIN)5A3 n€ amr--... a O FNty PoolBond PB-2008 ,� «__.� D OPAM Install in Plumbing T at least 3' Below Potty- Y's'! cep( UWE I MES THEDEEP WA cxor MU rxam 1 rpm M 7 mw Vacuum Head + Pressure Head Water level in Return Piping.Install eEL DVO » = Total Dynamic Head in sprinkler box for easy access C 7 —0 23'-0" SJ'-0" 35'-0" 5W (NO WATER BOND DETAILS FOR PIPING SCHEMATIC TYPICAL SECTION THRU POOL NICHLESS LIGHT SYSTEM (tap SCALE) POOL RATIO CUSTOM MOLDED PRODUCTS INC. WATER LEVEL -_: ti'�; •yam ' �,.�,;;'i...� HYDRO -STATIC RnJff •:'s:'�:. z: Lt.: ;'F7 DEVICE INSTALLED IN SINGLE CHANNEL DUAL am Fr CMP 25506-32X VGB PER FRC4501.t:s AREAS THAT Exc®r COMPLIANT 32" CHANNEL DRAIN WATER TAME IN SHELI :'..a; GOMPLVVa WaH 12 VAC FROM 2017 FLORIDA BUILDING CODE _ •.� POWER SUPPLY TRENCH DRAIN ME -i- a UM To /ANSI A112,19a UNDERWATER IJGFT32' 1" PVC CHANNEL DRAIN AND SUMP » 2.5 CONDUIT 25506-320-000 L== POOL FINISH *THREE 2- SOCKET x 2.5" SPIGOT PORTS ro awn ran -I *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA 2.5» PVC*IAMPO PENTAIR GLOBRITE-S :' tFIR SCHEDULE40 sLEFTE LISTED ROW RATES *WHITE PVC BODY MAIN DRAIN AMP 30 7 ;�%, NO BONDING *COVER GOES OVER BODY TO GIVE FINISHED LOOK 10 PITS OR GROUND FUSION -FUSION PPROD - WL REQUIRED The maximum flow rating for this suction rifting with the center port plugged and outer MODEL G4/U ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5" plumbing and 268 GPM (flour) POOL DETAIL NICHLESS UNDERWATER LIGHT DETAIL and 192 GPM (wall) when using 2' plumbing. The maximum flow rating for this suction (Nor SCALE) fining with the outer ports plugged and the center port open is 200 GPM (floor) and 168 GPM (NO SCALE) (wan) when using 2.5 plumbing and 184 GPM (flow) and 176 GPM (wall) when using 2' plumbing - Pipe Size 6 fps 8fps 1' 16 gpm-0.14' 21 9Pm 0.23' 1,5' 37 gpm 0,08' 50 gpm 0.14' 2' 62 gpm 0.06' 82 0.10' 2.5' 88 gpm 0.05' 117 gpm 0.09' 3' 136 gpm 0,04 ' 181 gpm 0.0E 4' 234 gpm 0,03' 313 gpm 0.05' 6' 534 gpm 0.02' 712 gpm 0.03, OUTSIDE ANGLE OF REPOSE 6' AND FURTHER - 4- THICK WAILS W/13 REHM 012- O.C. EACH WAY 3' TO 6' - 6' THICK WALLS W/13 REHM 012- O.C. EACH WAY V TO 3' - 8' THICK WALLS w/13 NERAR 012. D.C. EACH WAY Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer 1. Calculate Pool Volume: XXX ft XXX x 7.48(gal/Ft) = XXXX gal s rt. (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: XXX got / XXX = XXX + Xxx = XXX e Fc (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) Determine i Pipe Sizes: (System Flow Rate) 3 R• T Trunk Pipping to be 2_5 inch to keep velocity @ 8 fps max. at_117 gpm Maximum System now Rate. Return Piping to be 2.5 inch to keep velocity 0 8 fps max. at T17—gpm Maximum System Flow Rate. J• J: J Main Drain Cover( SEE _ABOVE) System Flow Rate must not exceed approved cover flow rate. 3 g (Make and Model) See Engineering Page for Drain Configuration O�� Q`Q OF EXCAVATION S IN THE ALKAE X REPOSE IS ALLOWABLE HOULPROVIDEB SHORING IS EXCAVATION AND Pump Model PENTAIR INTELLIFLO VS-3050 N.P+ 3 SECURE IL OR SETT EMENTD SUFFICIENT i0 SECURE SOILS FROM EROSION OR SET1lF1AEM ER DOM OR ORGINEER APPROVED FDOES �AACEONNiESEST Taal H.P=H.P.xsmim lepor. l H.p.ormommutbe2speedorvwMhlespeed BACKFTTTD NATOW ARE PROVIDED Flker Make PENTAIR C&C SIZE 150 PRIOR TO THE POURING OF THE PATIO Fear mot anaa based an 6hc hmxv boa, rate pod gal. /9H0 min.=Flow RALe Dike GP.M. by Cartridge =.375 a Sand =15 or D.E = 2 Time Controller make ON PUMP Model — COnlyds must Wanda a mnimun of two speeds. MISC. NOTES ,, .,\tit. EU FOR The hiherspeed ovemde is not to exceed are namal 0or24h whichever is less ILv! r 1-1 1. ALL STEPS AND SWTMWF BENCH EDGES MILL HAVE 2.6 CAPPIE BORDER OF OPPOSITE M CO \\\111I111/IJ NNN ALL Roo., PLIANCE N o .,fi o , COLOR OF GEM FRESH FOR VISIBILITY 2 MERGED To EE INSTALLED ARE WHERE s00E 4;,,-T. LUCI .. `� Q'P •"\C E Ng ••CF - � COUNTY HECK RAISED +6' ABOVE POOL 70' MEN R IC IC NL! RLTWM t 2 4. 37. UCcme No. 68212 — .: 801 Razelwoad Drive* 06-09-202( FL34g82 : %2O1L TE OF DESIGNED FOR: +.. STEP DETAI > . 1. TREAD IS MIN OF ID• WIDE 2. RISER iA� !�!� IM CUSTOM O0LS NOT GREATER THAN 12' EXCEPT IF i MORE THAN (3) TREADS ARE USED YFS(,+IIEI� RESIDENCE •" TRIC NOT INCLUDED"+# \.BEK RESIDENCE 3. ALL STEPS TO BE SOLID GUNK 3000 P.S.L 3411 S. INDIAN RIVER DR PWAREDBY: SHEET: STEPS Fr PIERCE, FL STEVE HORST 2 <ND SCALE) R N S R DESIGN VICES (772)201-7846 horsuteve@yahoocom ,*PENTAIR TDH nK-YEscamuGH ICALtULATOR STEP1 STEP 2 FOOLSPECfFICAT10N5 SELFCTF,OmPMENT - STEP 3O,SF� 3: TOH CALCULATION , Peel Volumef9aealale CA1a.Gr'diem SuceeR Lift: t.5na Turn Owr HAtumt: r.wlNwa -. Mention Ftow Rate: 44.72 GPM } Naximam nowRde ''. 113.09 GPM 6ELE'pTNN ,,,.WRT#= NIAMUN PIPEYELWIIY IFT/sECI Sl1mMlOUitEr 8 NMN MUM i MAC MING LENDERS ins lNtEr 52.00 MECRUi 8600 N a. 11HCX RETURN '� I NI pEBREE ELROW INLET 6 __� I DISCHARGE 13 :� IM1ELL10NL4R N-b 1 -. S>`\ TEETflRWGH INLET 0 o1scHARGE 3 (L.5"9 WAY VALVE 3 ULTIGTEMP 1 jINIELLIFLOYARIaeLE SPEED, V5KYR5. Vf.ORYSF 1 I 7 �1y* 0 ,ae3rm+aTya:�a�.itn f. � �. Flow Rah, 113.09 GAL/MIN Head LM 68.00 FT REWIREOMINPRIM PIPE512E i PBNP RPM RoNRateat5eleded Pump RPM 11309 i Had Linsxsgected Pump RPM: 68.00- I SYSr'1' RPM: Pate Reranithu PN: 113.09SAL/MIN satmaxRowRateatMax 68,00FT fill 121 IQ -Clean System Curve -Pump Curve ■ Desired Operation Point - Clean System A Pump Operation Point 11 APSP&rn- cl Iow.o, � ANSYAPSPACC 15a ENERGY EFFICEMY CCIIPWNCE INFORIMMI' ON FOR RE51ME L SWMMNG POOLS PRp1ECT NAME: pappREss YE5CHEK CONTM (N NAME Anoao.RFss: JM CUSTOM POOLS WNER; CIXYFRaCFOR PRONE: PATE: 6-9-20 ......r nn...vw.au. nmN W^rw rrx r.rc n�a.a rcarucrmer amr rvnvg •w mry air moor nrruerrr:Y ararmru nrrrmNcnrrrrrr lLLE nr IM KSWi[prl ar lUm aM ]IB PMesvanaklAP�t. hNnvlpandNw AmetlCan Nadond Shntlard ANL/APSP/I[C ]Sit 2a11 butsirMudedfwinfarmapon wh.CwmacwsshuidawdreaM twnpty wtt11 dNAN51/nPSPACC 15a2a31 stanEardwnidr [an bepurdnseE at www aPWarn 1. §52.1: Calculated pool volume a. Gallons: 16,100 ;or L 16,100 gallome; b. Cakubted GNbnr. /surJvice weofX (average depth) X748(OoW3) 2. §5.2-Lr Calculated filtration flow rate 2. 45 gpm - (Pool volume - 360or36gpm whichever 6 fanner) 3. §S.S.L- Pipe sizing: a. Minimum suction pipe diameter 3a. 2 inches p'nrer Nvsmdkstpipe shehom iebk l with 9 E)psAowzepeary the samewmwe Wnhem 2.) _ b. M4niminn suction branch pipe diameter 31ar WA inches (Coknbte: hemz. _(Wml^ecewb P(pes.__(wmntdyl-bmmAJbwmce Enter the imelkstppe sfmhpm TOUR 1'rsith a 6fPspow roI1aCIN'the mme wmore coon toe rakeloted nxtbn bronrhpowrote.l C. Minimum return pipe diameter 3c. 1.5 inches fEnterW smalkstpoe sluham Tebk l ,In a eJpsJbwtopocitythe samewmore thon into T) d. Minimum return branch pipe diameter 3d. N/A inches AiRcdROPRem2. (gpml*erartch s lguontiryl=brwrh/bw rare fgpm). - £Mtn lhe.Mnplksf ppe5vs f/am Tebk 1 with o BJpsJbwcoporifydwsamewmere men the cakubred rmwnbmmchJbwrwe.) 4. §5A.1: Filhx type and she: a. Fdte,rtype: (Cortridge, DE, Sand) 41. CART b. Minimum filter area 4br 119 Sri it. lmkvwte rtemz._fgpnl "fNmJwror f9PMt"zll fdhrNccors:fdhNpe-9.a>s. Sand=15, zlbfenrmous Eertl�z S. §SA.2: Backwash valve: X Non NIA _Yes, (Woenusage6wkwasowae rater rLSWt aJNem 3ew2iwMsrvhiehevers /wgtd S. inches - Table Iiiiee°c PN. she: I Is I r I ss I r I a4' I r I r• I r- NOMn 10.01¢ ]r I ExI so I1b vo - - $; NOMna1 GPNHa¢ 5f M 119 tit N ] {99 cal 6. Single -speed pump selection (when used): For %ogle-speetl pumps wMl a [oW hwsepower0.99 wfaa, fYtl and ernes rO1RpI1i1R pumphomthe Pod P, Database. a. Pump MGM b. Taal horsepoww 7. Mum -speed pump selection (when used): *532.1: Pools I),(pO'adorn or kss, sekcipump'pom [he daNbose uiM aLlew-Agpmhowequol ro nem2wku §5.12.2: Paoli ]lfm39dbrO a,more,.Y:krtpump•irons aw dwabeu wIM oCwve{gpm/leweaud to AemTwAss. 'MWN-speedpumps murthaveanespeed meted tlwtsotsfres uro re9dremenc a. Pump model b. Pump flow 053.2.1, 53.22: AAP%sx k CtvwA or Cgpn jbw WEM vI dwobae) 3/17/15 W ANv/a3P/ICC-I5 Stallard Writing Cwnminee Form bar N/A I_ fib. NIA or PENTAIR INTELLIFLO VS 7a. _ 7b. 70 OM 1 Of 2 Cam nerd Secewr Chrc 4.4.1.1 Heater has no pilot light 4.4.L2 Readily accessible on -off switch mounted outside of the heater X Heaters 4.3.1.3 No electric resistance,heating unless for hrground spa with tight fitting cover with R-6 insulation, or for pool with 60%of documented pool heating trwn an -site solar or recovered energy. 4.3.2 Heater efficiency: gas/oil fired heater efficiency at least 78%, heat pump COP at least 4.0 X 5.1.1 Pool finer pump listed in database X 5.3.1 Pool filter pump with total horsepower 1.0 or more is multi -speed X 5.3.3 Multi -speed pump controller programmed to default to the filtration flow rate when no auxiliary pool loads are operating within 24 hours and programmed with temporary override capability for servicing. X Pool systems 5.3.4 Single -speed pump controller capable of operating pump during off-peak electric demand. NIA 5.5.2 Pipe before pump has at Last 4 diameters at straight pipe. X 55.3 System installed with solar, or setup for the future addition of solar heating equipment by installing 18 inches of horizontal or vertical pipe after the filter and before a heater, or built -In or built 1p connections, cardedicated pipe to and from the pool. X 5.6 Directional infers for mixing pool water. X 2d2 g$ ggi 1$o ffiRg 801N �I.wI �8¢lig.�� act z Sw an a o �ti mow g� mpzxoQrzOR Z p1 j z W W W �01 E. O01 O r O 0. W n zz an,;N -U q� kmp�q E Or a� CCII a .eao z FPl 3 6 Vv qo z to l e w 0z a LY0.o z xu to 4 o m � m Qt oz a H a NOErti _ S m .a w0C% U LLr�� C1 64^>i ou m cz V O CA w m w MMI z REVIEWED IFOH CODE COMPLIANCL ST. LUCIE COUNTY Ronc, DESIGNED FOR: Ill CUSTOM POOLS YESCEK RESIDENCE 3411 S. INDIAN RIVER DR FT PIERCE, FL 11111111 ALL R4 CEIll; ,p.W618212 NW Drive* FL 34982 -• 1 t-/a7vmfj4y,, kI_ `l01 n1n111 ***ELECTRIC NOT INCLUDED{** PREPARED BY: STnRA�FfIlvOGR&ST 3 / DESIGN SERVICES 01-7846 horsLsteve@yahoocom