Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CARLTON SPECS
XR16 4TTR6 2, 3, 4 & 5 Tons Split System Cooling Product Data PUB. NO. 22-1864-03 © 2013 Trane 2 22-1864-03 Features and Benefits • CLIMATUFF™ 2-stage scroll compressor • Efficiency up to 18.0 SEER • All Aluminum SPINE FIN™ coil • DURATUFF™ weather proof and rust proof base • COMFORT ”R”™ mode approved for better comfort indoors • QUICK-SESS™ cabinet, service access and refrigerant connections with full coil protection • WEATHERGUARD™ fasteners • Glossy corrosion resistant finish tarpaulin gray cabinet with anthracite gray top • Internal compressor high/low pressure & temperature protection • Liquid line filter/drier • Low sound with advanced PSC fan motor • Service valve cover • R-410A refrigerant • From 70 to 100% capacity modulation • 100% run test in the factory • Low ambient cooling to 55° as shipped • Extended warranties available 22-1864-03 3 Contents Features and Benefits 2 General Data 4 Product Specifications 4 A-weighted Sound Power Level [dB(A)] 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 8 Mechanical Specifications 9 4 22-1864-03 Product Specifications Model No. 1 4TTR6024A1000B 4TTR6036A1000B 4TTR6048A1000A 4TTR6060A1000A Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 18 24 28 41 Max Fuse Size (Amps) 20 35 45 60 Compressor CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL No. Compress. – No. Stages 1 -2 1-2 1-2 1-2 RL AMPS - LR AMPS 13.0 - 52 17.0 - 82 21.2 - 104 32.1 - 152.9 Outdoor Fan FL Amps 0.74 0.74 1.00 1.30 Fan HP 1/8 1/8 1/5 1/4 Fan Dia (inches) 27.6 27.6 27.6 27.6 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-410A 9/13-LB/OZ 9/13-LB/OZ 12/9-LB/OZ 12/9-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 3/4 7/8 1-1/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Dimensions H x W x D (Crated) 46.4 x 35.1 x 38.7 51.0 x 35.1 x 38.7 51.0 x 35.1 x 38.7 51.0 x 35.1 x 38.7 Weight - Shipping 276 283 308 312 Weight - Net 240 245 271 275 Start Components NO NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat NO NO NO NO Optional Accessories: 4 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301 BAYCCHT301 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004 Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001 Refrigerant Lineset 5 TAYREFLN9* TAYREFLN7* TAYREFLN3* TAYREFLN4* 1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. General Data A-weighted Sound Power Level [dB(A)] A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] 63 125 250 500 1000 2000 4000 8000 4TTR6024A 72 43.7 52.6 54.3 62.4 60.4 57 54.1 46.6 4TTR6036A 72 38 50.4 56.8 60.4 59.8 57.2 55.2 49.2 4TTR6048A 73 44.2 50.4 58.9 63.1 63 57.4 53.6 47.4 4TTR6060A 74 42.2 53.8 57.8 66 65.7 57.7 58.4 51.7 Note: Rated in accordance with AHRI Standard 270-2008. SOUND POWER LEVEL [dB(A)]MODEL 22-1864-03 5 General Data AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling opera- tion.) Standard Noise Rating number is at 95°F outdoor air. Accessory Description and Usage Rubber Isolators — 5 rubber donuts to isolate condens- ing unit from mounting frame or pad. Use on any application where sound transmission needs to be minimized. Extreme Conditions Mounting Kit — Bracket kits to secure- ly mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial rooftops, etc. Low Ambient Cooling — For low ambient cooling below 55° see Application Guide APP-APG013-EN. 6 22-1864-03 Model Nomenclature Refrigerant Type 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Tw o Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial Family SEER 3 = 13 6 = 16 0 = 20 4 = 14 8 = 18 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier Outdoor Units 4T TR6036A1 000AA T U D 1 B 0 8 0 A 9 H 3 1 A A Furnace ConfigurationTU = Upflow/HorizontalTD = Downflow/Horizontal TypeE = 80% Induced Draft StandardD = 80% Induced Draft Premium C = 90% Condensing Standard X = 90% Condensing Premium H = 95% Condensing Premium Number of Heating Stages 1 = Single Stage2 = Tw o StageM = Modulating Major Design Change Minor Design Change Service Digit - Not Orderable Heating Input in 1000’s (BTUH) 080 = 80,000 BTUH Cabinet Width A = 14.5" Cabinet WidthB = 17.5" Cabinet WidthC = 21.0" Cabinet Width D = 24.5" Cabinet Width Air Capacity for Cooling Standard PSC Va riable Speed High Efficiency 24 = 2 To ns V3 = 3 To ns H3 = 3 To ns 36 = 3 To ns V4 = 4 To ns H4 = 4 To ns42 = 3.5 To ns V5 = 5 To ns H5 = 5 To ns 45 = 4 To ns 48 = 4 To ns 54 = 5 To ns 60 = 5 To ns72 = 6 To ns Vo ltage 9 = 115 Volts / 60 Hertz / Natural Gas A = 115 Volts / 50 Hertz / Natural Gas C = 115 Volts / Natural Gas with Communicating System ControlF = 115 Volts / Natural Gas with Integrated Electronic FilterD = 115 Volts / Natural Gas with Communicating System Control and Integrated Electronic Filter Draft Inducer Speeds 1 = Single Speed 2 = Tw o SpeedV = Variable Speed Gas Furnaces G A M 5 A 0 B 3 6 M 3 1 S A A BrandT = Better G = Good Product Type A = Air Handler Product Tier2 = Good, Entry Level Feature Set 4 = Better, Retail Replacement Mid Effy.5 = Better, Entry Level High Effy., Multi-Speed 7 = Best, Retail Replacement High Effy., Va riable-Speed 8 = Best, Retail Ultimate High Effy., Va riable-Speed Major Design Change Minor Design Change Unit Parts Identifier Airflow Type & CapabilityS = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton) M = Mid Effy Multi-Speed, 1-5 - nom. To nnage (cfm/ton)H = High Effy Multi-Speed, 1-5 - nom. To nnage (cfm/ton) V = High Effy Va riable, 1-5 - nom. To nnage (cfm/ton) No Descriptor0 = Air Handler / Coil System Control TypeS = Standard - 24 VAC C = CLII 13.8 VDC Size (Footprint) A = 17.5 x 21.5B = 21.0 x 21.5 C = 23.5 x 21.5 Cooling Size: Air Handler or Coil0-9 = AH Coil - 1000 BTU’s (18, 24, 30, 36, 42, 48, 60) Power Supply 1 = 208-230/1/60 Convertability M = Multi-poise 4-way F = Upflow Front Return, 3-way T = 3-way Air Handler 4 T X C B 0 3 6 A C 3 H C A A Series T = Premium (Heat Pump or Convertible Coil) C = Standard (Cooling Only) Refrigerant Type4 = R-410A Coil Design X = Direct Expansion Evaporator Coil Coil FeatureC = Cased A Coil A = Uncased A Coil F = Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A = 14.5" /13.3" B = 17.5" / 16.3"C = 21.0" / 19.8"D = 24.5" / 23.3"H = 10.5" Refrigerant Line Coupling 0 = Brazed Nominal Capacity in 1000's (BTUH) Major Design Change EfficiencyC = Standard S = Hi Efficiency (derived from 10 SEER products) Refrigerant Control 3 = TXV - Non-Bleed Coil CircuitryH = Heat PumpC = Cooling Airflow Configuration A = Upflow Only U = Upflow / Downflow H = Horizontal Only C = Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Service Digit - Not Orderable Heat Pump/Cooling Coils 22-1864-03 7 Printed from D157614P01 4TTR6024A, 036A Electrical Data Schematic Diagrams (SEE LEGEND) 8 22-1864-03 Electrical Data Schematic Diagrams (SEE LEGEND) 4TTR6048A, 060A Printed from D156975P03 22-1864-03 9 Electrical Data LEGEND Schematic Diagrams 10 22-1864-03 Dimensions 4TTR6 Outline Drawing Note: All dimensions are in MM (Inches). From Dwg. D152635 MODELS BASE A B C D E F G H J K 4TTR6024A 4 1045 (41 1/8)946 (37-1/4)870 (34-1/4)5/8 3/8 152 (6)98 (3-7/8)219 (8-5/8) 86 (3-3/8)711 (28) 4TTR6036A 4 1147 (45 1/8)946 (37-1/4)870 (34-1/4)3/4 3/8 152 (6)98 (3-7/8)219 (8-5/8) 86 (3-3/8)813 (32) 4TTR6048A 4 1147 (45 1/8)946 (37-1/4)870 (34-1/4)7/8 3/8 152 (6)98 (3-7/8)219 (8-5/8) 86 (3-3/8)813 (32) 4TTR6060A 4 1147 (45 1/8)946 (37-1/4)870 (34-1/4)1-1/8 3/8 152 (6)98 (3-7/8)219 (8-5/8) 86 (3-3/8)813 (32) 22-1864-03 11 Mechanical Specifications General The 4TTR6 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide se- lection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Cor- rosion and weatherproof CMBP-G30 DuraTuff™ base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff® 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include: centrifugal oil pump and modular plugs for electrical connections. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. For low ambient cool- ing below 55° see Application Guide. Trane www.trane.com 01/13 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.