Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 4roject Name: THOMPSON RESIDENCE Builder Name: MEL-RY CONSTRUCTION, INC. Street: 2151 NETTLES BLVD. Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH. FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2131.8 sgfl.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - F-xtlnsul,Erderior R=4.1 1898.40fN b. Frame- Wood, Adjacent R=11.0 233.33 ft 3. Number of units, if multiple family 1 c. N/A R= fN 4. Number of Bedrooms 2 d. N/A R= fN 5. Is this a worst case? No 10. Ceiling Types (1635.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1635.00 ft 6. Conditioned floor area above grade (ft� 1635 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A -R= ft' 11. Ducts R ft' 7. Windows(205.3 sqft.) Description Area a. Sup: Attic, Rel: Attic, AH: AHU CLST 6 140 a. U-Factor: Sgl, U=0.30 149.33 ft' SHGC: SHGC=0.20 b. U-Factor: Sgl, U=0.32 56.00 fN 12. Cooling systems kBtumr Efficiency SHGC: SHGC=0.25 a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft, SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A fP a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.214 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1635.0 sgfL) Insulation Area EF: 0.880 a. Raised Floor R=19.0 988.00 fN b. Conservation features b. Slab -On -Grade Edge Insulation R=0.0 647.00 ft' None c. N/A R= ft' 15. Credits None Glass/FloorArea: 0.126 Total Proposed Modified Loads: 61.82 PASS Total Baseline Loads: 62.16 1 hereby certify that the plans and specifications covered by Review of the plans and Q114E STgT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. nnrr (": _-.`. „ O PREPARED BY: Before construction is completed DATE: 3-2-242D this building will be Inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. COD with WEJ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1, 3=020 2:12 PM EnergyGaugep USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7 FORM R405-2017 INF'UI 5UMMAKY GHtGKLISI KtYUKI PROJECT Title: THOMPSON RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1635 Lot# 'Owner Name: Total Stories: 1 Block/Subd!Asion: y�# of Units: 1 Worst Case: No PlatBook: Builder Name: MEL-RY CONSTRUCTION, I Rotate Angle: 0 ,.. Street: 2151 NETTLES BLVD. Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH. Family Type: Single-family FL, New/E)dsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1635 13921.1 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 STAIRS UP 98 784 No 0 1 Yes Yes Yes 2 LIVING ROOM 242 1932 No 0 1 Yes Yes Yes 3 KITCHEN 162 1296 Yes 0 1 Yes Yes Yes 4 W/D 9 72 No 0 1 No Yes Yes 5 A/C CHASE 6 48 No 0 1 No Yes Yes 6 PANTRY 9 72 No 0 1 No Yes Yes 7 LINEN 15 120 No 0 1 No Yes Yes 8 M WIC 56 448 No 0 1 Yes Yes Yes 9 POWDER RM 32 256 No 0 1 No Yes Yes 10 HALLWAY 68 540 No 0 1 No Yes Yes 11 MASTER BEDROO 190 1520 No 0 1 1 Yes Yes Yes 12 ELEV. 2ND FLR 25 200 No 0 1 Yes Yes Yes 13 M TOILET 21 168 No 0 1 Yes Yes Yes 14 M BATH 55 436 No 0 1 Yes Yes Yes 15 SITTING ROOM 233 2166.9 No 0 1 Yes Yes Yes 16 BATH 2 80 744 No 0 1 Yes Yes Yes 17 BEDROOM 2 126 1171.8 No 0 1 1 Yes Yes Yes 18 CLST 2 17 153 No 0 1 No Yes Yes 19 AHU CLST 9 84 No 0 1 No Yes Yes 20 ELEVATOR 1ST FL 20 186 No 0 1 Yes Yes Yes 21 STAIR STORAGE 45 419 No 0 1 Yes Yes Yes 22 FOYER 117 1088 No 0 1 Yes Yes Yes 3/2/2020 2:12 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor STAIRS UP __ 98 ft2 19 1 0 0 _s— 2 Raised Floor LIVING ROOM ___ __ 242 ft' 19 1 0 0 3 Raised Floor KITCHEN __ __ 162 ft2 19 1 0 0 4 Raised Floor W/D -_ _- 9ft' 19 1 0 0 5 Raised Floor A/C CHASE ___ __ Eft' 19 1 0 0 6 Raised Floor PANTRY ____ ___ 9 fP 19 1 0 0 7 Raised Floor LINEN __ __ 15 ft' 19 1 0 0 8 Raised Floor M WIC ___ ___ 56 ft' 19 1 0 0 9 Ralsed Floor POWDER RM __ 32 ft' 19 1 0 0 10Raised Floor HALLWAY ___ __ 68 ft 19 1 0 0 11Raised Floor MASTER BEDRO ____ ___ 190 ft2 19 1 0 0 12Raised Floor ELEV. 2ND FUR ___ _ 25 fN 19 1 0 0 13Raised Floor M TOILET __ -_ 21 ft2 19 1 0 0 14Raised Floor M BATH ____ ___ 55 ft' 19 1 0 0 15SIab-On-Grade Edge Insulation. SITTING ROOM 24.4ft 0 233 ft' __ 1 0 0 16SIab-On-Grade Edge Insulation BATH 2 16.9 It 0 80 ft2 -- 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 2 12.9 It 0 126 ft2 __ 1 0 0 18SIab-On-Grade Edge Insulation CLST 2 1 ft 0 17 ft' 1 0 0 19SIab-On-Grade Edge Insulation AHU CLST 1 It 0 9 ft2 --- 1 0 0 20SIab-On-Grade Edge Insulation ELEVATOR 1ST 5 It 0 20 ft' --- 1 0 0 21Slab-On-Grade Edge Insulation STAIR STORAGE 9 It 0 45 ft2 __ 1 0 0 22SIab-On-Grade Edge Insulation FOYER 18 ft 0 117 ft2 __ 1 0 0 ROOF Roof Gable Roof Rod Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Bair Absor. Tested Tested Insul. (deg) 1 Hip Metal 1829 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1635 ft2 N N 312/2020 2:12 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) STAIRS UP 0 Blown 98 fl' 0.1 Wood - 2 Under Attic (Unvented) LIVING ROOM 0 Blown 242ft 0.1 Wood 3 Under Also (Unvented) KITCHEN 0 Blown 162 ft' 0.1 Wood _ 4 Under Attic (Unvented) W/D 0 Blown 9ft' 0.1 Wood 5 Under Attic (Unvented) A/C CHASE 0 Blown 6 ft' 0.1 Wood 6 Under Attic (Unvented) PANTRY 0 Blown 9ft' 0.1 Wood _ 7 Under Attic (Unvented) LINEN 0 Blown 15 ft' 0.1 Wood _ 8 Under Attic (Unvented) MWIC 0 Blown 56 fl' 0.1 Wood 9 Under Attic(Unvented) POWDER RM 0 Blown 32 ft' 0.1 Wood 10 Under Attic (Unvented) HALLWAY 0 Blown 68 ft' 0.1 Wood _ 11 Under Attic (Unvented) MASTER BEDRO 0 Blum 190 ft' 0.1 Wood 12 Under Attic (Unvented) ELEV. 2ND FLR 0 Blown 25 f' 0.1 Wood 13 Under Attic (Unvented) M TOILET 0 Blown 21 ft' 0.1 Wood 14 Under Attic (Unvented) M BATH 0 Blown 55 fN 0.1 Wood 15 Under Attic (Unvented) SITTING ROOM 0 Blown 233 ft' 0.1 Wood 16 Under Attic (Unvented) BATH 2 0 Blown 80 ft' 0.1 Wood 17 Under Attic (Unvented) BEDROOM 2 0 Blown 126 ft' 0.1 Wood 10 Under Attic (Unvented) CLST2 0 Biam 17 ft' 0.1 Wood 19 Under Attic (Unvented) AHU CLST 0 Blown 9ft' 0.1 Wood _ 20 Under Attic(Unverded) ELEVATOR 1ST 0 Blown 20 ft' 0.1 Wood _ 21 Under Attic(Unvented) STAIR STORAGE 0 Blown 45 ft' 0.1 Wood 22 Under Attic (Unvented) FOYER 0 Blown 117112 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 W Exterior Concrete Block- Ext lnsuSTAIRS UP 4.1 20 0 8 0 160.0 fN 0 0 0.6 0 _ 2 E Exterior Concrete Block- Ext InsdIlVING ROO 4.1 18 0 8 0 144.0 ft' 0 0 0.6 0 _ 3 SW Exterior Concrete Block - Ext InsdIIVING ROO 4.1 •27 6 8 0 2.20.0 fN 0 0 0.6 0 _ 4 W Exterior Concrete Block- Ext Inse11VING ROO 4.1 3 0 8 0 24.0 ft' 0 0 0.6 0 _ 5 E Exterior Concrete Block- Ext Insul KITCHEN 4.1 10 0 8 0 80.0 fN 0 0 0.6 0 6 E Exterior Concrete Block- Ext Insul M WIC 4.1 8 0 8 0 64.0 fN 0 0 0.6 0 _ 7 NE Exterior Concrete Block- Ext InsdBASTER BE 4.1 17 11 8 0 143.3 ft' 0 0 0.6 0 _ 8 E Exterior Concrete Block- Ext InsdMASTER BE 4.1 9 0 8 0 72.0 ft' 0 0 0.6 0 9 W Exterior Concrete Block- Ext InsiELEV. 2ND F 4.1 5 0 8 6 40.0 ft' 0 0 0.6 0 _ 10 W Exterior Concrete Block- Ext InsulM TOILET 4.1 3 0 8 0 24.0 ft' 0 0 0.6 0 _ 11 N Exterior Concrete Block - Ext Insul M BATH 4.1 7 2 8 0 57.3 ft' 0 0 0.6 0 _ 12 W Exterior Concrete Block- Ext Insul M BATH 4.1 8 0 8 0 64.0 fN 0 0 0.6 0 _ 13 N Exterior Concrete Block- Ext InstSITTING RO 4.1 8 0 9 4 74.7 ft' 0 0 0.6 0 _ 14 NE Exterior Concrete Block - Ext Insd91TTING RO 4.1 5 10 9 4 54A fN 0 0 0.6 0 _ 15 W Exterior Concrete Block - Ext InstSITTING RO 4.1 7 0 9 4 65.3 ft' 0 0 0.6 0 _ 16 NW Exterior Concrete Block- Ext InstSITTING RO 4.1 3 7 9 4 33.4 f' 0 0 0.6 0 _ 17 NE Exterior Concrete Block - Ext Insul BATH 2 4.1 8 11 9 4 83.2 ft' 0 0 0.6 0 18 E Exterior Concrete Block- Ext Insul BATH 2 4.1 8 0 9 4 74.7 fN 0 0 0.6 0 3/2/2020 2:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 19 E Exterior Concrete Block- Ext InstSEDROOM 2 4.1 13 0 9 4 121.3 ft' 0 0 0.6 0 _20 S Garage Frame -Wood BEDROOM 11 10 0 9 4 93.3 ft' 0 0.1 0.6 0 21 S Garage Frame - Wood AHU CLST 11 3 0 9 4 28.0 ft' 0 0.1 0.6 0 _ 22 W Exterior Concrete Block- Ext Ins®LEVATOR 1 4.1 5 0 9 4 46.7 ft' 0 0 0.6 0 _ 23 W Exterior Concrete Block- Ext Ins®TAIR STOR 4.1 9 0 9 4 84.0 ft' 0 0 0.6 0 _ 24 S Exterior Concrete Block - Ext Insul FOYER 4.1 11 0 9 4 102.7 ft' 0 0 0.6 0 _ 25 W Exterior Concrete Block - Ext Insul FOYER 4.1 7 0 9 4 65.3 ft' 0 0 0.6 0 26 E Garage Frame -Wood FOYER 11 11 0 9 4 102.7 ft' 0 0.1 0.6 0 27 N Garage Frame -Wood FOYER 11 1 0 9 4 9.3 f12 0 0.1 0.6 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Law-E Single Yes 0.3 0.2 N 4.0 tN 1 It O to 1 ft 0 in None None _ 2 W 1 Vinyl Low-E Single Yes 0.3 0.2 N 8.0 ft' 1 It 0 in 1 ft O in None None _ 3 E 2 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 fN 1 ft 0In 1 ft O in None None 4 SW 3 Vinyl Low-E Single Yes 0.3 0.2 N 18.3 ft' 1 ft O in 1 ft 0 in None None 5 SW 3 Vinyl Low-E Single Yes 0.3 0.2 N 10.0 ft' 1 It 0 in 1 It 0 in None None 6 W 4 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft' 1 It 0 In 1 ft O in None None 7 E 5 Vinyl Low-E Single Yes 0.3 0.2 N 9.0 ft 1 it 0 in 1 ft 0 in None None 8 NE 7 Vinyl Low-E Single Yes 0.3 0.2 N 30.0 ft' 1 It 0 in 1 It 0 in None None 9 E 8 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft1 ft 0 in 1 It 0 in None None _ 10 W 10 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft' 1 It 0 In 1 It O in None None _ 11 N 13 Vinyl Low-E Single Yes 0.32 0.25 N 32.0 ft' 1 ft 0 in 10 ft 0 in None None _ 12 NE 14 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft' 1 it 0 In 10 ft 0 in None None 13 W 15 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft' 1 ft O in 10 ft O in None None 14 E 18 Vinyl Low-E Single Yes 0.3 0.2 N 4.0 ft' 1 ft O In 10 ft 0 in None None 15 E, 19 Vinyl Low-E Single Yes 0.3 0.2 N 15.0 ft 1 It 0 in 10 ft 0 in None None _ 16 S 24 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft' 1 ft 0 in 11 ft O in None None 17 S 24 Vinyl Low-E Single Yes 0.32 0.25 N 24.0 ft1 ft 0 in 11 ft O in None None 18 W 25 Vinyl Low-E Single Yes 0.3 0.2 N 6.0 ft' 1 It 0 in 10 It 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 247 ft' 247 ft' 25 ft 9 ft . 11 3/22020 2:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000378 1622.2 89.06 167.49 .1343 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 16 29.4 kBtulhr 882 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SelPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft' DUCTS / — Supply — V # Location R-Value Area — Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 140 ft' Attic 14 ft' Default Leakage AHU CLST (Default) c(Default) c 1 1 TEMPERATURES Programableling lf)C�)Thermostat: N Jan Feb Mar] Venting [ ] Jan Feb X Maarr Ceiling Fans: May ]] 0� [X] �C] (j E j Ixl Apr Pr l 1 Mery l Jun [ ] Jul l 1 AugAul 1 Sep J LJ Jun O Jul l 1 Aug l 1 Sep txl Nov rOC�I Oct [X] Nov H Dec Decec 3/212020 2:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 t Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Ijeating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 88 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft 0 It 0.3 STAIRS UP Default(8 lbs/sq.ft. ft, ft 0.3 LIVING ROOM Default(8 lbslsq.ft. ft' It 0.3 KITCHEN Default(8 lbs/sq.ft. ft' It 0.3 W/D Default(8lbs/sq.ft. ft' ft 0.3 A/C CHASE Default(8 lbs/sq.ft. fN ft 0.3 PANTRY Default(8 lbs/sq.ft. ft' ft 0.3 LINEN Default(81bs/sq.f. to ft 0.3 MWIC Defaull(81bs/sq.fL ft' R 0.3 POWDER RM Default(8 lbs/sq.fL fN It 0.3 HALLWAY Default(8 lbs/sq.ft. fN It 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' It 0.3 ELEV. 2ND FLR Default(8 lbs/sq.ft. ft' It 0.3 M TOILET Default(8 lbslsq.ft. ft' It 0.3 M BATH Default(8 lbslsQ.ft. ft' ft 0.3 SITTING ROOM Default(8 lbslsq.ft. fN It 0.3 BATH 2 Default(B Ibslsq.ft. ft, ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 CLST 2 Default(8 lbs/sq.ft. fN It 0.3 AHU CLST Default(8 lbs/sq.ft. fN It 0.3 ELEVATOR 1ST FL Default(8 lbs/sq.fL ft' ft 0.3 STAIR STORAGE Defaull8lbs/s .ft. ft' it 0.3 FOYER 3/212020 2:12 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" 0 99 The lower the Energy Performance Index, the more efflclent the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 AHU CLST c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 29.4 SEER 16.0 a) Split system 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1635 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor.(welghted average) 7a. 0.305 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.214 c) Area 7c. 205.3 8. Skylights a) U-factor.(welghted average) Be. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and Insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier Installed 9a. 0.0 9b. 1910 9c. 10A1. 10A2. 4.1 1091. 11.0 10B2. 11a. 0,0 l l b. l l c. 11d. No 14, Heating system: Capacity27.0 a) Split system heat pump 'HSPF b) Single package heat pump HSPF c) Electric resistance COP LO d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE B Other 15. Water heating system a) Electric resistance EF 0.98 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f Heat recovery unit HeatReC"/o g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multlzone cooling credit e) Multlzone heating credit 0 Programmable thermostat No -*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, If not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. S � 7C G �� Builder Signature:�/�� Date: Address of New Home: 2151 NETTLES BLVD. City/FL Zip: JENSEN BEACH FL 3=020 2:13:20 PM EnergyGaug& USA 6.0.04 (Rev. 1) - FlaRes2017 FBG eth Edltlon (2017) compliant Software Page 1 of 1 2017EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insula on level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location AHU CLST 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 29.4 5. Is this a worst case? (yes/no) 5. No 3) b) S nlgleystem package SEER SEER 16.0 c) Ground/water source 3EERICOP 6. Conditioned floor area (sq. ft.) 6. 1635 d) Room unitIPTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted average) 7a. 0.305 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.214 14. Heating system: Capacity 27.0 c) Area 7c. 205.3 a) Split system heat pun p HSPF b) Single package heat I ump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural as AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 19.0 15. Water heating system c) Concrete, raised (R-value) 9c, a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tan EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump Nith tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1082. 16. HVAC credits claimed (F erforrnance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling cr t d) Radiant barrier installed 11d. No e) Multizone heating cr ' 0 Programmable thereto tat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through t is above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: r� r-'/� � �' k� Date: !4�` Address of New Home: 2161 NETTLES BLVD. City/FL Zip: 3=020 2:13:20 PM . EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edifion (2017) Compli�nt Software Page 1 of 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential P rformance Method Project Name: THOMPSON RESIDENCE Builder Name: MEL-RY CONSTRUCT ON, INC. Street 2151 NETTLES BLVD. Permit Office: ST LUCIE COUNTY City, State, Tip: JENSEN BEACH. FL, Permit Number: Owner. Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climat Zone 2 ) 1. New construction or eristing New (From Plans) 9. Wall Types(2131.8 sgft) Insulation Area 2 Single family or multiple family Single-family a. Concrete Block- Etd Insul, E:derior R=4.1 1898.40 fP b. Frame - Wood, Adjacent R=11.0 233.33 ft' 3. Number of units, it multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= fN 10. Ceiling Types (1635.0 sgtt.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1635.00 112 6. Conditioned floor area above grade (ft2) 1635 b. N/A R= ft. Conditioned flan area below grade (tt') 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (205.3 sgft.) Description Area a. Sup: Attic, Rat: Attic, AH: AHU CL T 6 140 a. U-Factor. Sgl, U=0.30 149.33 ft2 SHGC: SHGC=0.20 b. U-Factor. SgI, U=0.32 56.00 ft' 12. Coding systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 29.4 SEER:16.00 c. U-Factor. WA fe SHGC: 13. Heating systems kBkdhr Efficiency d. U-Factor: N/A it- a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft Area Weighted Average SHGC: 0.214 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1635.0 sgft.) Insulation Area EF: 0.980 a. Raised Fluor - R=19.0 988.00 fP b. Conservation features b. Slab -On Grade Edge Insulation R=0.0 647.00 ft' None c. WA R= It, 15. Credits None Glass/FloorArea: 0.126 Total Proposed Modified Loads: 61.82 PASS Total Baseline Loads: 62.16 I hereby certify that the plans and specifications covered by Review of the plans and ' this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 3-2-2020 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. _--: with the Florida Energy Code. OWNER(AGENT- BUILDING OFFICIAL: DATE: DATE: Compliance requires certifleation by the air handler unit manufacturer that the air handler enclot ure qualifies as certified factory -sealed in accordance with R403.&2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R4024.1.2). 3/2/2020 2:12 PM EnergyGaugeG USA 6.0.02 (Rev. 1) - RaRes2017 FBC 6th Edition (2017) Compliant S T Page 1 of 7