HomeMy WebLinkAboutCONTE PERMIT APP620/22 kW
GENERAC`
Specifications
Generator
G007038-1, G007039-1 G007042-2, G007043-2 G007038 -3,G007039-3 G007042-3, G007(143-3
Model
(20 kW) (22 kW) (20 kW) (22 kW)
Rated maximum continuous power capacity (LP)
20,000 Watts" 22,000 Watts' 20,000 Watts` 22,000 Walts'
` 18,000 Watts" 19,500 Watts "
Rated maximum continuous power capacity (NG)
18.000 Watts" 19,500 Watts
240
Rated voltage
Rated maximum continuous load current — 240 volts (LP/NG)
83.3 / 75.0 91.7 / 81.3 83.3 / 75.0 9'.7 ! 81.3
Less than 5%
Total Harmonic Distortion
90 amp p 90 amp 100 amp
100 am
Main line circuit breaker
1
Phase
2
Number of rotor poles
60
Rated AC frequency
1.0O
Power factor
12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CGA minimum
Battery requirement (not included)
4481/203 4661/ 211 436 / 198 445/202
Unit weight (lb / kg)
48 x 25 x 29 / 121.9 x 63.5 x 73.7
Dimensions (L x W x H) in / cm
67 67 67 67
Sound output in dB(A) at 23 it (7 m) with generator operating at normal load"
57
Sound output in dB(A) at 23 it (7 m) with generator in Quiet -Test" low -speed exercise mode" `
55 57 55
Exercise duration
5 min
Engine
GENERAC G -force 1000 Series
Engine type
2
Number of cylinders
999 cc
Displacement
Aluminum w/ castiron sleeve
Cylinder block
Overhead valve
Valve arrangement
Solid-state w/ magneto
Ignition system
Electronic
Governor system
9.51
Compression ratio
12 VDC
Starter
Approx. 1.9 1.8 L
Oil capacity including filter
3,500
Operating rpm
Fuel consumption
Natural gas ft3/hr (m3/hr)
V2 Load
204(5.78) 228 (6.46) 164 (4.64) 203 (5.75)
Full Load
301 (8.52) 327 (9.26) 287 (8.13) 306 (8.66)
Liquid propane 10/hr (gaVhr)
87 (2.37) [8.99] 92 (2:53) [9.57] 86 (2.36) (8.95] 92 (2.53) (9.57]
Load
Ful
Ful Loadl Load
130 (3.56) [13.48] 142 (3.90) (14.77] 136 (3.74) [14.15] 142 (3.90) [14.77]
Note Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all
load ranges - 3.5-7 In water column (0.87-1.74 kPa) for NG. 10-12 In water column (2.49-2.99 kPa) for LP gas.
For BTU content, multiply 10/hr x 2500 (LP) or 113/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG).
Controls
Two-line plain text multilingual LCD
Simple user interface for ease of operation.
Automatic start on utility failure. Weekly, Bi -weekly, or Monthly selectable exerciser.
Mode buttons: AUTO
Start with starter control unit stays on. If utility fails, transfer to load takes place.
MANUAL
Stops unit. Power is removed. Control and charger still operate.
OFF
Standard
Ready to Run/Maintenance messages
Standard
Engine run hours indication
Standard (programmable by dealer only)
Programmable start delay between 2-1500 seconds
Utility Voltage Loss/Return to Utility adjustable (brownout setting)
From 140-171 V / 190-216 V
Future Set Capable Exerciser/Exercise Set Error warning
Standard
Run/Alarm/Maintenance logs,''
50 events each
Cyclic cranking 16 sec on, 7 rest (90 sec maximum duration).
Engine start sequence
Starter cannot re-engage until 5 sec after engine has stopped.
Starter lock -out
Standard
Smart Battery Charger
Standard
Charger Fault/Missing AC warning
Standard
Low Battery/Ba,tery Problem Protection and Battery Condition indication
Automatic Voltage Regulation with Over and Under Voltage Protection' `
Standard
Under-Frequency/Overload/Stepper Overcurrent Protection
Standard
Safety Fused/Fuse Problem Protection
Standard
Automatic Low 011 Pressure/High Oil Temperature Shutdown
Standard
Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown
Standard
High Engine Temperature Shutdown
Standard
Internal FaulUlncorrect Wiring protection
Standard
Common external fault capability
Standard
Field upgradable firmware
"Sound levels are taken from the front of the generator. Sound levels taken from other sides of
Standard
the generator may be higher depending on installation parameters. Rating definitions - Standby: Applicable lot supplying
for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514,1S03046 and DIN6271). " Maximum kilovolt amps and current are
emergency power
subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.506 for each 1,000 it (304.8 m) above sea
level, and also will decrease approximately 1% for each 10 IF (6 °C) above 60 IF (16 °C).