HomeMy WebLinkAboutHealt Dept final approval dFTt APPLICATION #:AP1428406 STATE OF FLORIDA PERMIT #:56-SF-1982159 ti f � DEPARTMENT OF HEALTH 'b ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:FI1466781 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:07/16/2020 son w,e t FEE PAID:95.00 RECEIPT #:56-PID-4503503 APPLICANT: Zafer and Klara Termanini AGENT: Joseph Telese(Telese Builders LLC) PROPERTY ADDRESS: 8047 Spendthrift Ln Port Saint Lucie, FL 34986 LOT: 95 BLOCK: SUBDIVISION: Sabal Creek II ID#: 3321-502-0044-000-6 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1350.00 [21 525.00 [ ] [271 SURFACE WATER FT [ ] [02] TANK MATERIAL Concrete [ ] [281 DITCHES FT [ ] (031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [041 MULTI-CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-122 [ ] [311 IRRIGATION WELLS 100 FT [ ] [06] LEGEND 1. 01-011-16DC3 2. 01-011-97SC4 [ ] (321 POTABLE WATER 100 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 12 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 13 FT . [ ] [091 DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] (101 AREA [1] 660 [21 SQFT [ ] [36] DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 5.00 2. [ ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 08/12/2020 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 23.00 [ ] [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS 1.00 [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING [ ] (221 FILL AMOUNT [ ] [471 CONTRACTOR DAVID WHITESIDE(ACCUR [ ] [231 FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 EQ36(single c [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments; Comments are on page 2. 117 01 CONSTRUCTION [ APPROVED St. Lucie CHD DATE: 07/14/2020 DISAPPROVED Environmental Specialistll ian J Ingram(ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ] : St. Lucie CHD DATE: 08/12/2020 Environmental Specialist II Brian J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1428406 EID1982159 ak` APPLICATION #:AP1428406 try , STATE OF FLORIDA PERMIT #:56-SF-1982159 DEPARTMENT OF HEALTH , ytr ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:FI 1466781 �y CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:07/16/2020 FEE PAID:95.00 RECEIPT #:56-PID-4503503 Violation Number Comment Comments The system is sized for 4 bedrooms with a maximum occupancy of 8 persons(2 per bedroom), for a total estimated flow of 520 gpd. New ST, filter, DT, barnes 1/3 hp pump, and 660 sgft BED DF installed. Permit requires 660 sgft in a TRENCH. Contractor notified onsite. Drainfield reconfigured to TRENCH. Construction inspection approved. System ok to cover. Contractor notified onsite. Final inspection required potable water line setback,well inspections and setback, mound system, and final site grading. Municipal water now available in the area. Potable well may not be constructed. Wells constructed as irrigation wells. residence connected to municipal water. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1428406 EID1982159