HomeMy WebLinkAboutTCAP70-20200811-3-8-14-20 14-digitalseal-8-14-203x Place as shown Typical vertical #5 Debar Spacing �„ Align furring Straps to the closest corner & build in to center of each wall for an even 6" spacing for as much of the wall as possable Ancor Screws installed in But before concrete 4" #10 min sizt Galvanized or Epoxy Coated Window & Door Section acing Stager 2" from center uuck Top & Sides detail P.T. 2x 12 trimmed to 11" wide Buck Bottom detail P.T. 2x4 inside & outside Gap inbetween for concrete pour and vibe access 2x #5 Bar Vertical Each side, Lintel / Opening Detail Im Ca (ref :116(.) 1 \ Fluid Applied \Monolithic Flashing & water Barrier on External Cupola galls Ul('F) & window openings P.T. Buck G) Fluid applied Monolithic Flashing on all door & vrindot+ openings Window & Door Stirrup sizes & spacing overhead lintels FLOOR 1 ID A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Fan (Bottom Steel) *NR 1- #5 NR 1- #6 1- #6 *NR 1- #4 1- #4 1- #4 YNR 1- #4 *NR 1- #5 1- #6 (E) *NR *FL NR *FL *FL *NR *FL *NR *NR *NR *FL *NR *FL *FL YNR YNR 1- #5 YFL 1- #5 *FL 2- #6 *FL t- #5 *FL *NR *NR 1- #6 *FL 1- #4 *FL LINTEL DETAIL FLOOR 2 (Bottom Steel) 1- #4 1- #4 *NR ""NR 1- #5 1- #4 1- #4 1- #4 1- #4 1- #4 YNR 1- #4 *NR YNR (E) *NR *NR *NR YNR 12 *NR *NR *NR YNR YNR *NR *NR YNR YNR 1- #4 *NR YNR *NR *NR *NR *NR YNR 1- #5 1- #5 YNR *NR *NR 18 12 *NR Required Lintel and opening reinforcement 3_l -, Max lop Rebar _ #5 I Ypical or S Stirrups -Bottoni rebar Single oi- Double bar Standard Stirrup 7�3 steel - 4" min 19 j, fJ �c r ., u "S" Type Stirrup #3 steel 3!" min A scale none A. 24" Minimum distance. May wrap 90" around corners. B. Bucking System C. vertical reinforcement, 2) #5 vertical rebars each side of opening. D. Locate first stirrup at 1/2 spacing(s) from the face of opening. Remaining Stirrups at "S77 to stirrup end distance. E. Stirrup end distance. Specified in Lintel Tables. F. 900 rebar around all openings in addition to required Lintel and wall reinforcement. G. 2- #5 additional rebar around all openings, in addition to required Lintel and wall reinforcement. H. if lintel table has bottom reinforcing of at least 2 45 rebar, add 1- #5 rebar at top of opening. All shear reinforcement (#3 rebar) is at 6" spacing Lip to end distance at each end of lintel beam. *FL = Stirrups are required the Full Length of the Lintel Beam *NR = Not Required Note: required wall reinforcement, ICF blocks & stem wall (if applicable) not shown for clarity. 1/2" Plywood Gusset with 4-8D nails into top & bottom 2x4's Simpson I13 4/12 • "10" `, i This item has been electronically signed and sealed by Robert F. v �.�,,•ENS•� �, w, Oleck, Ph.D.,PE using a Digital '1 Signature and date. Printed (/ 1 copies of this document are not lJ l�L >, considered signed and sealed / Fi10p,. ` and the signature must o F�' •„ � ,. �°' �iai" i��� 'so verified on any electroniccopies. osfONA 11�l6`,,,a Simpson META 2 Tiedown for o, :rha, Cut away EPS foam, attach continous 2X6 P.T to ICF wall with 1/4" X 4 " Tapcons @ 8" O.C. Stagger top to bottom Front 4' Overhang & Corbel Section Digitally signed by Robert F O Date: 2020.08.14 11:00:06 -04'00' External Staircase detail (North)(S) CMU columns mid spaced inbetween windows "A" & "F 00"! 03.51 Page: 14 Salle: r- L O _ j G M a�w Aga a�� q �`-q uk�c, oM E �� J- r-'. m � r C Q 7 .7 d a "��8'_� � S'a z��`�z O C:°' w u 7 y 12 ti ❑7 G � -V-rI Page: 14 Salle: r- M E It Q r� V •a �0.4 '�4 CA rlM Page: 14 Salle: