Loading...
HomeMy WebLinkAboutProduct approvals, approved cover, metal C 'REEK ��� Certificate of Authorization No.29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017) Manufacturer: DREXEL METALS, INC. Issued October 9, 2018 1234 Gardiner Lane File Copy Louisville, KY 40213 716143 M M� ��l��www. www.drexmet.com Manufacturing: Drexel Metals Association of Regional Manufactures UAIA,&WED FOR Quality Assurance: Architectural Testing, Inc.(QUA1844) CODE COMPLIANCE SCOPE ST. €�L U E C TY Category: Roofing Subcategory: Metal Roofing Code Sections: 1504.3 Properties: Wind Resistance REFERENCES Entity Report No. Standard Year Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995 Architectural Testing(TST1558) 58389.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006 Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003 Architectural Testing(TST1558) 82776.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006 UL 1897 2012 Architectural Testing,Inc(an Intertek Company)(TST1527) H3245.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003 Architectural Testing,Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006 Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006 UL 1897 2012 Force Engineering&Testing(TST5328) 178-0055T-12 UL 580 2006 UL 1897 2012 Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003 -Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003 Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003 PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016 TAS 110 2000 PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2005a TAS 110 2000 PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003 PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006 UL 1897 2012 DRX15001.6 FL17678-R6 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein. ' f DREXEL METALS,INC. CREEK I Metal Roofing TECHNICAL SERVICES, LLC Entitv Report No. Standard Year PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006 UL 1897 2012 PRI Construction Materials;Technologies(TST5878) DMC-037-02-01 UL 580 2006 UL 1897 2012 PRI Construction Materials,Technologies(TST5878) DMC-037-02-02 UL 580 2006 UL 1897 2012 PRI Construction Materials Technologies(TST5878) DMC-038-02-01 UL 580 2006 UL 1897 2012 P CT DESCRIPTIO DMC 100NS/ Profile: 1 in.snap lock seam;kllakl6 in.coverage Description: Non-s mock standing seam roof panel with integral perorated nail strip tructuraI Material: in.24 ga. Fluropon®coated ASTM A792 AZ50,or - ASTM A653 G90; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3 18„ 5}"o.a. DMC 150SL Profile: 1.5 in.snap lock seam; Max. 16 in.coverage Description: Non-structural,snap lock standing seam roof panel Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or ASTM A653 G90; F =min.50 ksi; Shall conform with FBC Section 1507.4.3 12�— i I I DRX15001.6 I FL17678-R6 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not specifically addressed herein.