HomeMy WebLinkAboutProduct approvals, approved cover, metal C
'REEK
��� Certificate of Authorization No.29824
17520 Edinburgh Dr
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE,C EDITION(2017)
Manufacturer: DREXEL METALS, INC. Issued October 9, 2018
1234 Gardiner Lane File Copy
Louisville, KY 40213
716143 M
M� ��l��www.
www.drexmet.com
Manufacturing: Drexel Metals Association of Regional Manufactures UAIA,&WED FOR
Quality Assurance: Architectural Testing, Inc.(QUA1844) CODE COMPLIANCE
SCOPE ST. €�L U E C TY
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Architectural Testing(TST1558) 56840.02-122-18 TAS 100 1995
Architectural Testing(TST1558) 58389.01-122-44 UL 580 2006
Architectural Testing(TST1558) 58459.01-122-44 UL 580 2006
Architectural Testing(TST1558) 58461.01-122-44 TAS 125 2003
Architectural Testing(TST1558) 82776.01-109-44 UL 580 2006
UL 1897 2012
Architectural Testing(TST1558) 82784.01-109-44 UL 580 2006
UL 1897 2012
Architectural Testing(TST1558) 83296.01-109-44 UL 580 2006
UL 1897 2012
Architectural Testing,Inc(an Intertek Company)(TST1527) H3245.01-450-18 TAS 125 2003
Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.02-450-18 TAS 125 2003
Architectural Testing,Inc(an Intertek Company)(TST1527) H9058.01-450-18 TAS 125 2003
Architectural Testing,Inc(an Intertek Company)(TST1527) 13391.01-450-44 UL 580 2006
Force Engineering&Testing(TST5328) 178-0054T-12 UL 580 2006
UL 1897 2012
Force Engineering&Testing(TST5328) 178-0055T-12 UL 580 2006
UL 1897 2012
Hurricane Test Laboratory(TST1527) 0287-0209-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0308-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0311-07 TAS 125 2003
-Hurricane Test Laboratory(TST1527) 0287-0313-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0512-07 TAS 125 2003
Hurricane Test Laboratory(TST1527) 0287-0706-07 TAS 125 2003
PRI Construction Materials Technologies(TST5878) VLS-005-02-01 ASTM B 117 2016
TAS 110 2000
PRI Construction Materials Technologies(TST5878) VLS-004-02-01 ASTM G 155 2005a
TAS 110 2000
PRI Construction Materials Technologies(TST5878) DMC-004-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-005-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-006-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-007-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-008-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-009-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-014-02-01 TAS 125 2003
PRI Construction Materials Technologies(TST5878) DMC-016-02-01 TAS 100 1995
PRI Construction Materials Technologies(TST5878) DMC-017-02-01 Rev 1 UL 580 2006
UL 1897 2012
DRX15001.6 FL17678-R6 Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.
' f
DREXEL METALS,INC.
CREEK I Metal Roofing
TECHNICAL SERVICES, LLC
Entitv Report No. Standard Year
PRI Construction Materials Technologies(TST5878) DMC-018-02-01 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-024-02-01 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-033-02-01.1 UL 580 2006
UL 1897 2012
PRI Construction Materials;Technologies(TST5878) DMC-037-02-01 UL 580 2006
UL 1897 2012
PRI Construction Materials,Technologies(TST5878) DMC-037-02-02 UL 580 2006
UL 1897 2012
PRI Construction Materials Technologies(TST5878) DMC-038-02-01 UL 580 2006
UL 1897 2012
P CT DESCRIPTIO
DMC 100NS/ Profile: 1 in.snap lock seam;kllakl6 in.coverage
Description: Non-s mock standing seam roof panel with integral perorated nail
strip tructuraI
Material: in.24 ga. Fluropon®coated ASTM A792 AZ50,or -
ASTM A653 G90; Fy=min.50 ksi; Shall conform with FBC Section 1507.4.3
18„
5}"o.a.
DMC 150SL Profile: 1.5 in.snap lock seam; Max. 16 in.coverage
Description: Non-structural,snap lock standing seam roof panel
Material: Min.24 ga. Fluropon®coated ASTM A792 AZ50,or
ASTM A653 G90; F =min.50 ksi; Shall conform with FBC Section 1507.4.3
12�—
i
I
I
DRX15001.6 I FL17678-R6 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use,or other product attributes that are not
specifically addressed herein.