HomeMy WebLinkAboutHealth Dept APPLICATION #:AP 1407311 STATE OF FLORIDA PERMIT #:56-SF-1938802 DEPARTMENT OF HEALTH DOCUMENT #.FI1395997 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:04/05/2019 we • 515.00 FEE PAID: RECEIPT #:56-PID-3896058 APPLICANT: Glenn Theobald AGENT: MICHAEL STUHR(ASHTON SEPTIC TANKS, INC.) PROPERTY ADDRESS: TBD Anita St Fort Pierce, FL 34982 LOT: BLOCK: SUBDIVISION: ID#: 3403-331-0007-000-2 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER FT [ ] [02] -TANK MATERIAL Polyethylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ . l [04] MULTI-CHAMBERED [ Y N ] I ] [30] PUBLIC WELLS FT [ ] [05] OUTLET. FILTER Polylok PL-68 [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 38 FT [ ] [07] WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 5 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 71 FT [ ] {09] DEPTH TO LID [ ] (35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 509.4 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER x [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. I ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 04/06/2020 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ A80VE / BELOW ]BM 8.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR MICHAEL W STUHR(ASHTO [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED i Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / c St. Lucie CHD DATE: 02/25/2020 DISAPPROVED ]' Enyrr-cpr; ngram(ENVIRONMENTAL HEALTH),_Otal Specialist 11 FINAL SYSTEM [ APPROVED / DISAPPROVED 1: r St. Lucie CED DATE: 04/06/2020 Environmental Specialist II an J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1407311 EID1938802 dt APPLICATION #:AP1407311 ` STATE OF FLORIDA PERMIT #:56-SF-1938802 ' DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:F11395997 • � CONSTRUCTION INSPECTION AND FINAL,APPROVAL DATE PAID:04/05/2019 W9 FEE PAID:515.00 RECEIPT #:56-PID-3896058 Violation Number Comment Comments The system is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of 300 gpd. New ST,filter,and 5x9 long BED DF installed. No violation,system ok to cover. Contractor notified by phone. Needs final inspection for mound system,gutters,and final site grading: Final system approved. Contractor emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1,0.1 AP1407311 EID1938802