Loading...
HomeMy WebLinkAboutTrussOFFICE USE ONLY: DATE FILED: 8/3/2020 REVISION FEE: Aoo� PERMIT # SLC.2029-0084 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 4451 St. Lucie Blve Fort Pierce, FL 34946 DETAILED DESCRIPTION OF PROJECT REVISIONS: 5 of 12, Sheet 6 of 12 and sheet 7 of 12). layout and CONTRACTOR INFORMATION: STATE ofFL REG./CERT. #: GC1522209 BUSINESS NAME: Proctor Construction Compa QUALIFIERS NAME: Rick MacDonald - ADDRESS: 2050 US 1, Suite 200 CITY: Vero Beac STATE: PHONE (DAYTIME): 772-234-8164 OWNER/BUILDER INFORMATION: ST. LUCIE CO CERT. #: ZIP: 32960 FAX: 772-234-8188 NAME: A-1 Truss Supply ADDRESS:4451 St. Lucie Blvd CITY: Fort Pierce STATE: FL ZIP: 34946 PHONE (DAYTIME: 772-409-1010 FAX: 772-409-1015 ARCHITECT/ENGINEER INFORMATION NAME: EDC Engineering ADDRESS: 10250 SW Village Parkway, Suite 201 CITY: Port St. Lucie PHONE (DAYTIME): 772-462-2455 STATE: FL -- FAX: LCCC:9/23/09 RX I Revised 06/30/17 * NOTE: ALL TRUSS TO WALL AND/OR TRUSS TO LEDGER CONNECTIONS BY BUILDER. o s (UNLESS NOTED OTHERWISE) m d 8 — * NOTE: ALL CEILING DROPS BELOW BEAM ARE yM ny a a '00) �> c s BY BUILDER. (UNLESS NOTED OTHERWISE) 2 m ) w v o d m ya `E$" o I = NOTE: THIS TRUSS PLACEMENT DIAGRAM IS TO SHOW W v oo 0p a� Y c o tw 'TRUSS I.D. AND TRUSS LOCATION ONLY. THE BUILDING •Za", c DESIGNER IS RESPONSIBLE FOR THE STRUCTURAL " -_ 0 L W O do .t.. C T C it STABILITY INDIVIDUAL TRUSS ENGINEERING DRAWINGS FORE o E 2 °0 0)Z JGRAVITY AND UPLIFT LOADS. E N o c o m n �V^vdrna8 a L S FOR BRACING & ERECTION DETAILS REFER TO BCSI-03 ¢ o t `o •o AND/OR ENGINEER OF RECORD. aa3cca,n 2 o a d t y 0) O c N 0 #. ._ amREPRESENTS THE LEFT SIDE W — y v OF EACH TRUSS DRAWING E 0 mo .oc > > 2 2 C O y y G C _IM cc a N M. C@ U W Bo1 vw22Z6 c `y 1 (NOTE: REFER TO SIMPSON CONNECTOR 8 " w " o rna = ❑o+ CATALOG FOR INSTALLATION DETAILS) m 2 0 E o----ac 8 =1 -Froa a, B01A A LUS24 H HHUS46 (� - - - w " E ps Bmn LUS26 THA426 - - - 00 m a 3 >". J R 0T�H 1.--= B°, C HUS26 K MUS26 S- _ = M= 2 -- BOi m m p N � '� � N 0 � HUS28 L THJA26 T -- o `3 0 2- a._ s d E HHUS26-2 M A35 U -- oc d 2 c o a .� Sol ca B°, F HHUS28-2 N -- - V -- 0, a m m d O. y E a) } - em G LUS46 PaE9 m °o Bo, - ~ a HBB HANGER BY BUILDER BBB BEAM BY BUILDER ; 2 8 10 3 Bm �d .2 1d -- Bo+ c '-a m"c".cyS Z LSTA12 @ TC & BC NOTE: LSTA STRAP s m R o rn TC INDICATED TO BE USED IN co 00 G E o Zt LSTA12 @ CONCORDANCE WITH 5 2 8 y '2'- - Zb 0._ B°' LSTA12 @ BC CORNERSET DETAIL. e m c F zm o c 2 B°' LOADING ROOF FLOOR WIND LOAD M E N cm E y °sm�CSol LIVE LOAD 20 125 ASCE 7-10 Z m �: N 3 E o a) _ °' BmA a o 00 Q= c rn 0 2 BmA ~ V DEAD LOAD 10 10 160 C = a d & c - 7 ; o p� LIVE LOAD 0 0 Residential CAT II m az 2 a —Sol �0 O,N.O ..ypNL .71 So, � m :C DEAD LOAD 10 12 Closed otm_ B02 Y TOTAL LOAD 40 147 FBC 2017 RES ° O " y w c N o i E 2 2 c 2 0 Q 'O N 2 U W y N w. " ? DURATION FACTOR 1.25 1.00 TPI 2014 N 2 6 d O W E o '� "0 o W Js REV DATE BY REMARKS 0ADD 24" CANTILEVER TOy x y Z J3 1 06/30/202 JS EAST SIDE° 2" y 0= 2 a�-y'H02 pco w m U d N> U 07 t N r O _ _ zlZ dt'g o 0? o � 3" o C 2 07/06/20 JS _ 3 u d La c 2"= rn ADD 0a ID ATTIC;❑ d C O W " _0 s , 3 07/11/20 JS 5 8 _ m�; s _ . o ,c o 0 E o. c . y 0 y E 0 Iu ID 0 - ova,°�mtD e a•. d C — _ b y o�awL - in C F OI_: O d O 0 O ._ dt•-�j N10 10. co.. , � It is understood that above [-]APPROVED c o ` ^� -- w 2 conditions have been reviewed & o d Q L are acceptable for the fabrication APPROVED AS NOTED m m 3 �; g s at trusses, elevations, pitches, N .__ 2 ) ; ° E overhangs, fascias,ceiling ❑ REVISE AND RESUBMIT y 0.0 ° € 0 1 y �v o elevations/pitches, bearing 2 ` ° 2 cm, = E conditions & all detail pertaining REJECTED 2 0 � 0 8 a t A 8 " to this truss placement Ian. N � a " p p o Sv,� "QQ back charges will be accepted ; o o 12 Xfa_ m c w without previous written approval DATE cc y d q, cmN UM — from an A-1 Roof Trusses E E C .__ o 9 o representative. REVIEWED BY m o 2 w y o S o o 'o 'oco"Qp2oo PLAN DATE ARCH: 01/07/2020 STRUCT: 12/30/2019 2 m y> o U '6 ) 0] - CUSTOMER Al TRUSS 2 m c o y L m 0 8a O C L L. 00 R N c0 � N IA 8 E ma-o d E O« ":_ y O a JOB NAME MAINTENANCE BLDG a $ .5 a2 p � E! L � a d O 01 0 y m 2,y N to c OPTION(S) REVIEWED FOR � 8 ~ 062 C r m9 W T�•�= yWo,e &2 0 0„OOQZ- c ov COMMUNITY ST. L.UCIE COUNTY H m c" Q C r / LOT # c 8 2 A M a° y w= B O 0 O"" C 2 O y OCC � l0 a t XX - a C F O U C O L 0 C N O m 01 C O CITY .: a r o '.9 1- .. . rno ° c a"i c �.' 00 COUNTY v y m a aZi .y y 0 a)a y ``4`ltllr,ti, a+i^rut`Jf. BLDG. BLDG. o a c m 3 —° c"¢ O E d m o m Q •s a) p '�f, TYPE #. �8wc•`omLa"= 9 ' �' y -N0. 8$ 6 _ JOB # Al MB MASTER y 2 = 0 H a > ag 8 cm LNNC EC.N Cw t0 ATE 0 €k` DRAWN SCALE w 2' E y d " DATE 1/9/20 oav°o�>8�2m yn �o« 4•fij�A.C+� ....... \ is NTS Z >' m'6 N v° a y ac) %YCjNA)\�"ti*s E d c oredar 8 Q .� N rn= V a) c ° A VISION �E=2 8��52 f Awl ROOFW.aDo mYmam y2 TRUSSES W t y = a9 U �. U c 0 a) E. c= 0 ° �. � Q L L L U y a+" O " r > C r 2 43 - AFLORIDA CORPORATION i m 0 c 0 0 o� =v°4 Ph 772-409-1010 / Fax 772-409-1015 D = 8 ..M.2 " n http://www.aItruss.com G X'cd�rn>od$vm8 A#A-1 ROOF NTRUSSES A FLORIDA CORPORATION Lumber design values are in accordance with ANSIITPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. RE: Job Al MB A-1 Roof Trusses 4451 St Lucie Blvd Site Information: Fort Pierce, FL 34946 Customer Info: A-1 ROOF TRUSS Project Name: MAINTENANCE BLDG Lot/Block: Model: Address: 4451 SAINT LUCIE BLVD Subdivision: City: County: State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 2017 RES / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 40.0 psf Floor Load: 147.0 psf This —1,-ne include- 9e h,li„idual AaleA T--e r1e-inn rtrmuinns —r! 19 AAAM-1 M —4— With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,see ron 5 of the Florida Board of Professional Engineers Rules. . E-9],�*/LTn •Y "• No. Seq # Truss Name Date No. Seq # Truss Name Date No. Seq # Truss Name Date 1 2589 A01 7/13/20 13 3062 FL01 7/13/20 25 2976 PB05 7113/20 2 2592 A01A 7/13/20 14 2547 HA 7/13/20 26 3219 HG5 7/13120 3 2560 A02 7/13/20 15 2522 A 7/13/20 27 STDL01 STD. DETAIL 7/13/20 4 2561 A03 7113120 16 2538 J10 7113/20 28 STDL02 STD. DETAIL 7113/20 5 2562 A04 7/13/20 17 2524 J3 7/13/20 29 STDL03 STD. DETAIL 7/13/20 6 2568 A05 7/13/20 18 2541 J5 7113/20 30 STDL04 STD. DETAIL 7h3/20 7 2564 A06 7/13120 19 2526 J7 7113120 31 STDL05 STD. DETAIL 7/13/20 8 3550 A07 7/13/20 20 2544 J9 7/13120 32 STDL06 STD. DETAIL 7/13120 9 3568 A07A 7/13/20 21 2949 PB01 7/13120 33 STDL07 STD. DETAIL 7/13/20 10 2574 B01 7/13/20 22 2954 PB02 7/13/20 34 STDL08 STD. DETAIL 7/13120 11 2577 B01A 7/13/20 23 2980 PB03 7/13/20 35 STDL09 STD. DETAIL 7/13/20 12 12586 1 B02 7/13/20 124 12983 1 PB04 7/13120 36 STDL10 STD. DETAIL 7/13/20 The buss drawina(s) referenced have been onwared bvAidna Enaineered Products. Inc. undermvdirectsunervision haled an I ie namaretels nrnvided hvA-1 RmfTmsses. Lhl. Truss Design Engineer's Name: Rama Pranav Kristam My license renewal date for the stale of Florida is February 28,2021. NOTE:The seal on these drawings Indicate acceptance of professional engineering responsm0'ity soletyforthe truss components shown. The suhabilityand use of components forany padkularbullding Is the responsibility of the building designer, perANSIMPM Sea 2. TheTruss Design Dawing(s)(TDD[s]) referenced have been prepared based an the construction comments (also referred to at times as'Structural Engineering Documental provided bythe Building Designer Indicating the nature and charaderof the work The design aiteriatherein have been transfened to Rama Panav Kristam PE by [Al Roof Trusses or specific location]. TheaeTDDs (also refened to attmies as'Structual Delegated' Engineering Docum entsl are speclaNystructual component designs and may be part of the pmject's deferred or phased submittals. As aTnrss Design Engineer (Le, Specialty Engineer), the seal here and on the Too represents an acceptance of professional engineering responsibirlyforthe design of the single Truss depicted on the TDD only. The Building Designerrs responsible forand shall coordinate and review the TDDs for wmpat2)Mlywith thebwr tten engineering mquhaments. Please review al TDDs and a➢rebted notes Rama Panav Kcstam, PE 4451 St Lucie Blvd. Suite 201 Fort Pierce, FL 34946 Page 1 of 2 REVISION A-f ROOF TRUSSES A FLORIDA CORPORATION RE: Job Al MB No. Seq # Truss Name Date 37 STDL11 STD. DETAIL 7I13120 38 STDL12 STD. DETAIL 7/13/20 39 STDL13 STD. DETAIL 7113I20 40 STDL14 STD. DETAIL 7/13/20 41 STDL15 STD. DETAIL 7/13/20 42 STDL16 STD. DETAIL 7/13120 Lumber design values are in accordance with ANSIIrPI 1-2014 section 6.3 y These truss designs rely on lumber values established by others. ' Page 2 of 2 Job Truss Truss Type Ory I Ply 07/1112020 Al MB A01 HIPS 1 4 73' } 43W =7X10 =4X6 �6X8 1112X4 =6X8 =4X6 =7X10 13' { 2589 72 o5X6 F 5� G H I J K L a5X6 T SX10 =HW14E M ';5X70 T m E4X6 At D VJ7 E�!nN =010 m n C 0 1 y3 A B AS ZZ x1( yV AA _SX6 Y=4X8 W =H0510 U S P C AF AE ACAD =H0510 =HO510 =5X6 TT 1 =4X10 =H0714 =4X6(Al) S�, PLATE REO. P SEAT PLATE REQ. SEW i _� 8-1- 9' -{ 51'4'{-26--{ 69'4" i-- 11'1"12 11'1"12 --{ Loading Criteria (ps0 Wind Criteria Code I Misc Criteria DeflICSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L#f Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sld: 2014 VERT(LL): -0.880 1873 384 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 1.760 1 436 394 AF 7995 /- /- 1- 14644 I- BCDL: 10.00 Risk Category: ll FT/RT:10(0v10(10) HORZ(LL):-0.274 R - - R 7995 1- I- /- 14644 /- Des Ld: 40.00 EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.536 R - - Wind reactions based on MWFRS Mean Height: 28.00It WAVE, HS Creep AF Br Width = 8.0 Min Re 1.7 9 q = NCBCLL: 10.00 TCDL: 5.0 psf CSI:.2A Max TC CSI: 0.327 R Width = Min Re. = 1.7 Load Duration: 1.25 ° 5.0 psf BCDMWFRS Max BC CSI: 0. 588 ing Bearings AF & R are a rigid surface. are 24.0 Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 Bearings AF & R require a seat plate. C&C Dist a: 6.93 fl Max Web CSI: 0.690 90 Loc. froml: not in 9.00 Maximum Top Chord Farces Per Ply (Ibs) Wgt: 1904.0Ibs Chords Tens.Comp. Chords Tens. Comp. GCpl: pi: 0.10.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A -B 15 -12 I-J 4515 .8331 Lumber Purling B-C 198 -478 J-K 4515 -8331 Top chord 2x6 SP 2400f-2.OE In lieu of structural panels or rigid ceiling use purling, to brace all [ C @ c,�y92 17 K- 25492 Bot chord 2x6 SP 240Of-2.OE all BC @ 60" Do. 2861 M 2861 -5047 Webs 2x4 SP #3 :Wt 2x8 SP 24001-1.8E: E - F 2861 -5047 M - N 492 :W32x4 SP M-30: Wind F-G 4012-7359 N-O 3171 -5517 .W7 2x4 SP #2: Wind loads and reactions based on MWFRS. G - H 4515 -8331 O - P 1-478 H-I 4515 -8331 P-O 15 15 -12 Nailnote Lett and right cantilevers are exposed to wind Nail Schedule:0.131"x3", min. nails Additional Notes Maximum Bat Chord Forces Per Ply (Ibs) Top Chord: 1 Raw @12.00" o.c. Chord..Tens.Comp. ..Tens.Comp. Chords Tens. Comp. Bot Chord: 1 Row @ 8,50" o.c. WARNING: Furnish a copy of this DWG to the Installation conVectol. _ to Webs : 1 Row @ 4" o.c. follow provisions of BCSI in handling and installation oftmsses dBnA€sull In4iMou805 X - W 7389 -40W Repeat nailing as each layer is applied. Use equal Injuries. Do not permit Inexperienced and uninstructed people toAffAgLryWssq;4 See43 W - V 4686 -2655 spacing between rows and stagger nails in each row "WARNING" note below. BCSI recommends retaining a registerWCppgess -2908 V - U 4686 -2655 to avoid splitting. engineer for the design of temporary bracing. AB -AA 4686 -2655 U - S 5066 -2908 In addition apply (1) 112" bolt or 0.22"-0.25" mirdmax dia. X 6.0" AA-Z 4686 -2655 T- R 84 -43 length wood screw at each joint location. Z - Y 7389 -4029 R - P 487 -205 (1) 112" bolts may be used for (2) 0.131"x3", min. nails on Y - X 7389 -4029 Either The Top or Bottom Chords. Maximum Web Forces Per Ply (Ibs) Special Loads P Webs Tens.Comp. Webs Tens. Comp. -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac. 1.25) C -AE 1120 -1833 X- K 1018 .518 TC: From 62 plf at -2.50 to 62 pit at 11.15 TC: From 31 plf at .1to 31 plf at . C -AC 4755 -2781 K - W 239 -416 58 TC: From 62 plf at 58.199 71 to 62 plf at 71.83 83 AE-AC 2fi3 -75 W - L 28SO -1447 BC: From 20 plf at 0.00 to 20 pH at 11.15 AC -AD 31 -28 L - U 777 -481 BC: From 10 plf at 11.15 to 10 plf at 58.19 AC- E 490 -299 U - M 288 -432 BC: From 20 plf at 58.19 to 20 plf at 69.33 E -AB 288 -432 M - S 490 -299 BC: 1280 lb Conic. Load at 11.15,58.19 F -AB 777 -481 S -T 31 .28 BC: 408 lb Conic. Load at 13.06,15.06,17.06,19.06 F-Z 2860-1447 S-R 263 -75 21.06,23.06,25.06,27.06,29.06,31.06,33.06,34.67 Z-G 239 -416 S-0 4755 -2781 36.27,38.27,40.27,42.27,44.27,46.27,48.27,50.27 62.27,54.27,56.27 G-X 1018 -518 R-0 1120 -1883 I-X 70 -87 Plating Notes All plates are 3X6 except as noted. --WARNING" Please thonoughlyreviewthe Wl ROOF TRUSSES("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER("BUYER-)ACKNOWLEDGMENT-form. Verify design parameters and read notes on this Truss Design DraArg (TDD) and the Spedalty Engineer referenes shoat before use. Unless othermse eased! on Ne TDD, only Npine mnneGorplates shall be used for 0e TDD W be valid. Asa Tmss Design Encinee m /l.e. Sp alN Enalneer). n o seal on am TDD mnresenN an av nm nm of Ma nmfxasinnal nnninwnnn and duties s NOT the Job A1MB Truss Truss Type Oty Ply 07/11/2020 A01A HIPS I I4 12 5 T (7 �5X12 -HO? ;+ =4X6(A1) 05X6 C D InBW 1� A AF A B1 -_010 SEAT PLAT i 11'1"12 =7X10 =4X6as6X8 1112X4 =6X8 =4X6 =7X10 F T3 G H I T3 J K T4 L AB AA �4X8 Y�4X8 W =HOStO U ACAD =-HO510 iaH0510 =4X8 2592 r 13' e5x6 Z`r5X12 ,N es4X10 =H07B 14 7 R 4X6(Al) SEAT PLATE REQ. 65'4° 2-1 2', Y'.2', 2', 2'. Z. 2'. 2'. 2' 174742'. 2'. 2'. 2'. 2'. Z. Z 11'1"12--{ N a 0 1 Loading Criteria Mao Wind Criteria Code I Misc Criteria DeflICSI Criteria A Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L#1 Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sld: 2014 VERT(LL): 0.978 1 786 384 Loc R+ / R- / Rh / Rw / U ! RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 1.958 1 392 384 AF 8542 /- /- /- 14644 /- BCDL: 10.00 Risk Category: II FT/RT:10(0)l10(10) HORZ(LL): 0.301 R - - R 8542 (- A 1- /4644 /- Des Ld: 40.00 EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.604 R - - Wind reactions based on MWFRS Mean Height: 28.00 it WAVE, HS Creep Factor. 2.0 AF Big Width = 8.0 Min Req = 2.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.526 R R Big Width = 8.0 MinReq = 2.5 Load Duration: 1.25 BCDL: 5.0 psf Max BC CSI: 0.671 Bearings AF & R are a rigid surface. Spacing: 24.0" MWFRS Parallel Dist: 0 to h/2 Bearings AF & R require a seat plate. C&C Dist a: 6.93 ft Max Web CSI: 0.764 Loc. from endwalnot in 9.00 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 1904.0 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A-B 15 -12 -J 4514 -8916 Lumber Purllns B-C 123 -384 J-K 4514 -8916 Top chord 2x6 SP #2 :T3, T4 2x6 SP 2400f-2.OE: In lieu of structural panels or rig id ceiling p use puffins tins to brace all C 1 1 -5944 K - L 4013 -79112 @ L Bot chord 2x6 SP 24001-2.0E :B1 2x6 SP #2: all BC @ 60" oc. �!"95929 - M 2862 -5468 Webs 2x4 SP #3 :W 1 2x8 SP 2400f-1.8E: E - F 2862 -5468 M - N 3166 -5925 :W32x4 SP M-30: Wind F-G 4013-7982 N-O 3181 -5944 :W7, W9 2x4 SP #2: Wind loads and reactions based on MWFRS. H 4514-8916 O-P 124 H - 4514 -8916 P - O -312 Nailnote Lett and ngnt cantilevers are exposed to wind Nall Schedule:0.131"x3", min. nails Additional Notes Maximum Bat Chord Forces Per Ply (Ibs) Top Chord: 1 Row @12.00" o.c. Chords Tens.Comp. Chords Tens. Comp. Bot Chord: 1 Row @ 7.75" o.c. WARNING: Furnish a copy of this DWG to the Installation contlactan. Failnte to Webs : 1 Row @ 4" o.c. follow provisions of BCSI in handling and installation of trusses X - W 8011 -4030 Repeat nailing as each layer is applied. Use equal injuries. Do not permit inexperienced and uninstructed people tojptAbWsslil£ See50 W - V 5069 -2651 spacing between rows and stagger nails in each row 'WARNING" note below. BCSI recommends retaining a registerWJ)Aess§M -2925 V - U 5069 -2651 to avoid splitting. engineer for the design of temporary bracing. AB -AA 5069 -2651 U - S 5473 .2926 In addition apply (1) 1/2" bolt or 0.22"-0.25" min/max dla. X 6.0" AA- Z 5069 -2651 T - R 105 -50 length wood screw at each joint location. Z-Y 8011 -4031 R-P 392 -129 (1)1/2' bolts may be used for Y - X 8011 -4031 (2) 0.131"x3", min. nails on Either The Top or Bottom Chords. Special Loads -(Lumber Dur.Fac =1.25 / Plate Dur.Fac. 1.25) TC: From 62 plf at -2.50 to 62 plf at 11.15 TC: From 31 plf at 11.15 to 31 plf at 58.19 TC: From 62 plf at 58.19 to 62 plf at 71.83 BC: From 20 plf at 0.00 to 20 plf at 11.15 BC: From 10 plf at 11.15 to 10 plf at 58.19 BC: From 20 plf at 58.19 to 20 plf at 69.33 BC: 1280lb Conc. Load at 11.15,58.19 BC: 408lb Conc. Load at 13.06,15.06.17.06,23.06 25.06,27.06,29.06,31.06,33.06,34.67,36.27,38.27 40.27,42.27,44.27,46.27,52.27,54.27,56.27 BC: 681 lb Conc. Load at 19.06.21.06,48.27,60.27 Plating Notes All plates are 3X6 except as noted. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-AE 1118-2013 X-K 978 -517 C -AC 5266 -2871 K - W 240 -400 AE-AC 132 -10 W-L 3116 -1451 AC -AD 25 -19 L - U 862 -491 AC-E 479 -292 U-M 312 -461 E-AB 312 -460 M-S 479 -292 F-AB 862 -491 S-T 25 -19 F-Z 3117-1452 S-R 133 -10 Z - G 240 -400 S - O 5266 -2871 G-X 977 -517 R-0 1118 -2013 I-X 69 -89 ing Q.a. Speolaxy Engineer), Me seal on any MD represents an acceptance of Me p 1-1. The design assumptions, loading condWons, suitability and use of this Truss fore In Me sonleat of Me IRG Me IBC. local bulldho code and WI-1: The aoMoval of the Job Truss Truss Type Oty Ply 07/11/2020 2560 A1MB A02 I HIPS 12 I 1 �1 m 1 15, 12 5(7 v5 =4X6t5X74 =HO A1) C (a BW Y 33 A AF A BI ACAD =6X10 39'4' =7X10 =4X6 1113X4 =5X8 =7X10 =5X8 =4X6 F T3 G H Is J K T3 L Is, I\I ' i=IMI" �i' AS AA Z Y-4XB �H0510 =5X6 =H0510 Loading Criteria(ps0 Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph SCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category. ll EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 28.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0" MWFRS Parallel Dist: h/2 to h C&C Dist a: 6.93 ft Loc. from endwall: not in 17.01 GCpi: 0.18 Wind Duration: 1.60 Top chord 2x6 SP #2 :T3, T4 2x6 SP 2400f-2.OE: Bot chord 2x6 SP 2400f-2.0E :B1 2x6 SP #2: Webs 2x4 SP #3:W1 2x8 SP 2400f-1.8E: :W3 2x4 SP M-30: : W4, W7 2x4 SP #2: Code I Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 3X6 except as noted. Purlins In lieu of structural panels or rigid calling use pudins to brace all flat TC @ 24" oc, all BC @ 60" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Additional Notes WARNING: Fumish a copy of this DWG to the installation contractor. Failure to follow provislons of BCSI in handling and installation of trusses can result in serious Injuries. Do not permit Inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. and read W V U =5X6 �H0510 K6 �sX14 =600 S P 77 D =H0714 B7 m4X6(A1) SEAT PLATP REQ. 65'4' -1 69'4' T 1 Defl1CSl Criteria ♦Maximum Reactions (Ibs) PP Deflection in too Udefl LN Gravity Nan -Gravity VERT(LL): 0.846 1 908 384 Loc R+ / R- I Rh / RW / U I RL VERT(CL): 1.710 1 449 384 AF 2988 /- 1- 11955 11484 1350 HORZ(LL): 0.303 R - - R 2988 I- 1- 11955 11484 1- HORZ(TL): 0.619 R - - Wind reactions based on MWFRS Creep Factor. 2.0 AF Brg Width = 8.0 Min Req = 3.5 Max TC CSI: 0.781 R Brg Width = 8.0 Min Req = 3.5 Max BC CSI: 0.704 Bearings AF & R are a rigid surface. Max Web CSI: 0.975 Bearings AF & R require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 485.8 lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0616.15 A-B 58 0 1-1 5468 -8679 B • C 645 -1121 J - K 5468 -8679 C - D 4277 -7079 K - L 5006 -7860 D - E 4286 -6978 L- M 3759 -59M E - F 3740 -5958 M - N 4327 -6978 F - G 4989 -7860 N - O 4318 -7079 G - H 5468 -8679 O - P 634 -1119 H -1 5468 -8679 P - O 58 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B -AE 1224 -662 X - W 7919 -4521 AE-AD 135 -71 W-V 5463 -3058 AC -AB 6476-3680 V-U 5463 -305B AB -AA 5463-2984 U-S 6476 -3775 AA-Z 5463-2984 T-R 135 -74 Z-Y 7919-4447 R-P 1222 -652 Y-X 7919 -4447 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C -AE 1853 -2643 X - K 885 -553 C -AC 6452 -4193 K - W 890 -1008 AE-AC 1277 -474 W-L 2707 -1766 AC -AD 88 0 L - U 576 -156 AC- E 576 -136 U - M 763 -1080 E -AB 741 -1080 M - S 576 -153 F -AB 577 -149 S - T 88 0 F - Z 2707 -1766 S - R 1353 -716 Z - G 890 -1008 S - O 6452 -4152 G-X 885 -553 R-0 1840 -2643 I-X 551 -577 CUSTOMER (-BUYER-)ACKNOW4EDGMEN form. e. Unless o1b.Wse slated on the MD. onN Alain. by a Contract agreed upon in wring by all par a es darned N TPI4. Job Truss Tmss Type City Ply 07/11/2020 2561 Al MB I A03 HIPS 2 1 6 I - 17' ) 354' } 17' .7X8 =5X8 =5X8 �7X8 12 Ps 3X6 F G H I J K L X6 �SX6 5 ��5X6 T ( (a) N soH0714 4) X(HO714=H0714 A1=40 a) nn 6(A7) osfi (C Bw P AA Z V X W V U S 39 A 1m p AEA B1 ABAC =4X70=H0510 =H0710�H0510�4X10 aM B7 HTT14 6X40(") 1113X6 1113X6 SEAT PLATE REQ. SEAT PLATE REQ. 65'4' i -{ 6—{— 9' -} 514- -}- 9' 6—{ 69'4" Loading Criteria (ps0 Wind Criteria Code I Misc Criteria De0/CSI Criteria ♦ Maximum Reactions (Ibs) TOLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.751 1 999 384 Loc R+ ! R- / Rh / Rw / U I RL BOLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 1.518 1 506 3S4 AE 2988 !- /- /1974 11482 1385 BCDL: 10.00 Risk Category: 11 FTIRT:10(0)/10(10) HORZ(LL): 0.308 R - - R 2988 I- !- 11974 /1482 1- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.629 R - - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 28.00 It WAVE, HS Creep Factor. 20. AE Br Width = 8.0 Min Re 3.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TO CSI: 0.765 = R Brg Width = 8.0 Min Re 3.5 9 Load Duration: 1.25 BCDL: 5.0 sf P Max BC CSI: 0.618 Bearings AE & R are rigid surface. . Spacing: 24.0' MWFRS Parallel Dist: h/2 to h i Bearings AE 8 R require a seat plate. C&C Dist a: 6.93 ft Max Web CSI: 0.948 Maximum Top Chord Forces Per Ply (Ibs) Loc. from not In 17.00 ft Wgt: 485.8 lbs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18.18 i: Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A-B 58 0 1-1 4507 -7081 Lumber B-C 645 -1137 J-K 4507 -7081 C - D 4291 -7130 K - L 3478 -5235 Top chord 2x6 SP #2 D - E -7003 -5703 L - M Bot chord 2x6 SP 2400f-2.0E :Bi 2x6 SP #2: 3573 4340 E - F 3573 -5703 M - N 4340 -7004 Webs 2x4 SP #3 :W1 2x8 SP 2400f-1.8E: 032x4 SP M-30: F-G 3463-5235 N-O 4336 -7130 :W42x4 SP #2: G-H 4493-7081 O-P 633 -1135 H -1 4493 -7081 P - Q 58 0 Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 4X6 except as noted. ('•) 2 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purlins In lieu of structural panels or rigid ceiling use purims to brace all flat TC @ 24" oc, all BC @ 60' oc. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the Installation contractor. Failure to fallow provisions of SCSI in handling and installation of trusses can result in serious Injuries. Do not permit Inexperienced and uninstructed people to install trusses. See 'WARNING' note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B -AD 1242 -663 X - W 7349 -4160 AD -AC 135 -75 W-V 6B29 -3863 AB -AA 6532-3704 V-U 6829 -3863 AA-Z 6829-3792 U-S 6532 -3797 Z-Y 6829 -3792 T-R 135 -77 Y-X 7349-4160 R-P 1240 -651 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Camp C-AD 1B31 -2633 I-W 402 -398 C -AB 6534 -4244 W - K 635 -179 AD -AB 1296 -483 K-U 1343 -1922 AB -AC 89 0 U - L 1571 -745 AB- E 584 -114 U - M 960 -1387 E -AA 936 -1387 M - S 583 -130 F-AA 1571 -739 S-T 89 0 AA- G 1343 -1922 S - R 1372 -721 G - Y 635 -179 S - O 6535 -4203 Y-1 402 -397 R-0 1817 -2632 rOMER('BUYER°)ACKNOW DGMENP form. id. no SoodalN Enoineer Is NOT Ire Job Truss Truss Type Qty Ply 07/11/2020 A1M6 A04 I HIPS 12 I 1 I 25e2 T n T c 8X8 31'4' 1113X4 =6X8 =4X6 F G H =8X8 19, Iwo p - gH0714 =4X6(Al) (H071 C (a MEN BW a> A ACA B1 ZAA _7X8(") SEAT. PLATE REQ. 6' 1 9, Loading Criteria (ps11 Wind Criteria TCLL: 20.00 Wind Sld: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: ll EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 28.00 It NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 ° MWFRS Parallel Dist: h/2 to h C&C Dist a: 6.93 It Loc. from endwall: not In 17.0( GCpi: 0.18 Wind Duration: 1.60 Top chord 2x6 SP #2 But chord 2x6 SP 2400f-2.OE :B1 2x6 SP #2: Webs 2x4 SP #3:W1 2x6 SP #2: :W3 2x4 SP M-30: :W4 2x4 SP #2: :Lt Splice Block 2x4 SP 03: :Rt Splice Block 2x4 SP #3: Y=7X6 =4X6 Code / Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Bracing (a) Continuous lateral restraint equally spaced on member. Plating Notes All plates are 3X6 except as noted. (++) - This plate works for both joints covered. (")1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. W V U T_46 =4X10=HO510 �4X6 =7X6 Puriins In lieu of structural panels or rigid ceiling use puriins to brace all flat TC @ 24" oc, all BC @ 60° oc. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Additional Notes WARNING: Furnish a copy of this DWG to the installation contractor. Failure to follow provisions of BCSI in handling and installation of trusses can result In serious Injuries. Do not permit Inexperienced and uninstructed people to install trusses. See 'WARNING'note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. n vlew the'A-1 ROOF and „ =H1319 ++) = X6(Al) �i MW1 O" N pp O =H0714 Bi SEAT PLATF REQ. 65'4' 2-1 T rn T DeB/CSI Criteria A Maximum Reactions (Ibs) PP Deflection in foe Udefl L/# Gravity Non -Gravity VERT(LL): 0.676 G 999 385 Loc R+ I R- / Rh I Rw / U I RL VERT(CL): 1.366 G 564 385 AC 2987 A /- /1990 M481 /420 HORZ(LL): 0.291 P - - P 2987 A /- 11990 /1481 /- HORZ(TL): 0.595 P - - Wind reactions based on MWFRS Creep Factor. 2.0 AC Big Width = 8.0 Min Req = 3.5 Max TC CSI: 0.925 P Brg Width = 8.0 Min Req = 3.5 Max BC CSI: 0.487 Bearings AC & P are a rigid surface. Max Web CSI: 0.971 Bearings AC & P require a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 495.6 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A-B 58 0 H-1 4120 -6335 B•C 63B-1129 I-J 4123 -6320 C - D 4373 -7289 J - K 3489 -5500 D - E 3440 -5538 K - L 3454 -5538 E - F 3475 -5500 L - M 4414 -72B9 F-G 4120-6336 M-N 625 -1126 G- H 4120 -6335 N- O 58 0 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B -AB 1236 -658 V - U 6347 -3508 AB -AA 136 -84 U-T 5017 -2754 Z-Y 6690-3781 T-S 5017 -2754 Y-X 6018-2685 S-Q 6690 -3875 X- W 5018 -2685 R- P 136 -86 W - V 6347 -3508 P - N 1234 -645 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-AB 1810-2621 I-U 668 -631 C - Z 6687 -4342 U - J 1565 -1061 AB- Z 1297 -465 S - L 1148 -1714 Z -AA 90 0 J - S 691 -126 Z-D 633 -112 L-Q 634 -129 D-Y 1123-1713 Q-R 91 0 F - Y 696 -123 Q - P 1372 -705 F - W 1577 -1073 Q - M 6686 -4300 W-1 162 -161 P-M 1797 -2621 G-W 645 -617 ACKNOWLEDGMENrfaen. Job Truss Truss Type Qty, Ply 07/11/2020 Al MB A05 HIPS 2 1 zssa r 21' -}- 2T4- 21' i %7X8(R) 1113X4 �5X8 �4X6 107X8(R) H I J K L 12 5 p 1111.5X4 T G M 1111.5X4 T Ti E F (a) (a) ( ( ( N O m 1114X4('°) =4X6(A1) w 9a)P C (a 4 QT7 B a ) R a7 A AA yy Z =H0510 X W U S T A1114XI( ABAC =7X8 =4X8 =4X6 =7X8 yy = =4X6(Ai) -10X1� 1113X6 103X6 113X6 =10X74 _�H7319 SpA PLATE REQ. { BEAT PLAT1F REG. 654° 1 -{ F6—{-9. { 51'4° 26' r 694' Loading Criteria fw0 Wind Criteria Code I Misc Criteria DefIICSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection In loc L/defl LH! Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.616 1 999 384 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 1.182 1 650 384 AE 3161 !- !- /2005 /1479 /455 BCDL: 10.00 Risk Category: 11 FT/RT:10(0)/10(10) HORZ(LL): 0.324 T - - T 3170 /- /- 12005 /1479 /- EXP: C Kzt: NA Des Ld: 40.00 Plate Type(s): HORZ(TL): 0.626 T - - Wind reactions based on MWFRS Mean Height: 28.00 ft WAVE, HS Creep Factor: 2.0 AE Br Width = 8.0 Min Re 2.6 9 q NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.761 T Brg Width = 8.0 Min Req = 2.6 Load Duration: 1.25 BCDL: 5.0 psf " Max SC CSI: 0.430 Bearings AE & T are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: h/2 to h Bearings AE & T require a seat plate. C8C Dist a: 6.93 ft Max Web CSI: 0.966 Loc. from endwall: not in 17.00 ft Maximum Top Chord Forces Per Ply (Ibs) Wgt: 508.21bs Chords Tens.Comp. Chords Tens. Comp. GCpI: 0.18 Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A-B 58 0 J-K 3703 -6155 Lumber B-C 717-1316 K-L 3707 -6177 Top chord SP i!2 :Ti 2x6 SP 2400f-2.OE: C - D 736 -1304 L - M 3340 -5671 chord 2x6 SP x6 D - E 4238 -7862 M - N 4429 -7914 WeBat W1 2x2.OE Webs 2x4 SP2x :Wt 2x8 SP 2400f-1.8E: E - F 4366 -7928 N - O 4412 -7955 :W3, W4, WS 2x4 SP $2: F-G 4384-7887 O-P 4282 -7889 G - H 3327 -5648 P - Q 739 -1304 Bracing H-I 3703-6155 Q-R 720 -1316 (a) Continuous lateral restraint equally spaced on member. 1-1 3703 -6155 R - S 58 0 Plating Notes Maximum But Chord Forces Per Ply (Ibs) All plates are 5X6 except as noted. Chords Tens.Comp. Chords Tens. Camp. (•') 2 plate(s) require special positioning. Refer to scaled plate plot details for B -AD 1425 -722 Y-X 6198 -3034 special positioning requirements. AD -AC 140 -90 X - W 5169 -2497 Loading AB -AA 5918-3056 W-U 59Q -3131 AA-Z 5148-2429 V-T 140 -93 Truss passed check for 20 psf additional bottom chord live load in areas with Z - Y 6198 -3034 T - R 1426 -727 42"-high x 24°-wide clearance Purlins Maximum Web Forces Per Ply (Ibs) In lieu of structural panels or rigid ceiling use pudins to brace all flat TC @ 24" oc, Webs Tens.Comp. Webs Tens. Comp. all BC@60"oc. C-AD 252 -393 K-X 613 -541 AD-D 3050-48M X-L 1322 -839 Wind AD -AB 3316-1425 L-W 858 -332 Wind loads based on MWFRS with additional C&C member design. D -AB 39M -2283 W - M 795 -966 Left and right cantilevers are exposed to wind E -AB 302 -263 M - U 1712 -740 AB -AC 95 0 U - V 95 0 Additional Notes AB-G 1708 -710 U-O 302 -263 WARNING: Furnish a copy of this DWG to the installation contractor. Failure to G -AA 787 -966 U - P 4001 -22% follow provisions of BCSI in handling and installation of trusses can result In serious H -AA 865 -330 U -T 3329 -1497 Injuries. Do not permit inexperienced and uninstructed people to install trusses. See H -Z 1314 -848 P -T 3026 4848 "WARNING' note below. BCSI recommends retaining a registered professional I - Z 584 -556 T - Q 255 -394 engineer for the design of temporary bracing. Z-K 187 -186 0e Too In All caPlteil fi, tiara as dencd In TPI-1. u Fwvfmm Iv nmNN,M nNMi, Mv.uUwn..n.miv°im N<ACM Tn�avm Job Truss Truss Type Al MB A06 HIPS Qty 2 Ply 07/11/2020 1 zssa f 23' { 234' — -( 23' -{ .7X8 �4X6 �5XB =4X6 =7X8 G H I J K T 5 p -5X6 F -5X6 T E (a) M kL H0714 D (a) N �H0714 0 4X6(AI1-H071 a) (a=4X6(Al)ZZ O B W=4X8 t P 1 33 A Y=--4X6 yya W �7X6 U S14= Q AFA B1 ACAD m7X6 =7X8 =4X8 77 =H0714 B1 =7X8(°') =7X8(••) SEAT PLATE REO. SEAT PIA7JE REQ. F 65'4° { 6_+_ 9' 51'4° '1 9' T6LI 69'4° Loading Criteria (psq Wind Criteria Code I Misc Criteria DegICSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in loc Udell Ulf Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.548 X 999 385 LOG R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 1.107 X 696 385 AF 2987 /- /- 12014 /1477 1489 BCDL: 10.00 Risk Category. II FT/RT:10(0)/10(10) HORZ(LL): 0.263 R - - R 2987 /- /- 12014 /1477 /- EXP: C Kzt: NA Plate Type(s): Des Ld: 40.00 HORZ(TL): 0.538 R - - Wind reactions based on MWFRS Mean Height: 28.00 It WAVE, HS Creep Factor: 20. AF Big Width = 8.0 Min Req = 3.5 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.727 R 8.are Min Req = 3.5 Load Duration: 1.25 BCDL: 5.0 psf ° Max BC CSI: 0.455 ing AF &= Bearings AF & R are a rigid surface. Spacing: 24.0 MWFRS Parallel Dist: 4/2 to h Bearings AF & R require a seat plate. C&C Dist a: 6.93 It Max Web CSI: 0.954 Loc. from not in 17.00 ft Maximum Top Chord Forces Per Ply (Ibs) Wgt: 516.6 lbs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 .18 I: Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 A-B 58 0 I-J 3380 -5102 Lumber B-C 627-1118 J-K 3090 -4495 C - D 4135 -7222 K - L 3211 -4928 Top chord 2x6 SP #2 D - E 3585 -5845 L - M 3626 -5807 Bol chord 2x6 SP 2400f-2.OE :B1 2x6 SP #2: E - F 3608 -5807 M - N 3603 -5845 Webs 2x4 SP #3 :Wt 2x6 SP #2: : W3 2x4 SP M-30: F - G 3200 -4928 N - O 4177 -7222 :W42x4 SP #2: G-H 3080-4495 O-P Bit -1115 :Lt Splice Black 2x4 SP #3: H -1 3380 -5102 P - Q 58 0 :Lt Splice Block 2x4 SP 93: :Rt Splice Block 2x4 SP #3: Maximum Sot Chord Forces Per Ply (Ibs) Bracing Chards Tens.Comp. Chords Tens. Comp. (a) Continuous lateral restraint equally spaced on member. B -AE 1223 -644 X - W W51 -2678 AE-AD 135 -70 W-V 5315 -29M Plating Notes AC -AB 6617 -3543 V - U 5315 -2950 All plates are 3X6 except as noted. AB -AA 5315 -2878 U - S 6617 -3637 (••) 2 plate(s) require special positioning. Refer to scaled plate plot details for AA-Z 5315 -2878 T - R 135 -72 special positioning requirements. Z-Y 5051 -2651 R-P 1220 -629 Y - X 5051 .2651 Purlins In lieu of structural panels or rigid ceiling use pudins to brace all flat TC Q 24" oc, all BC Q 60" oc. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind Additional Notes WARNING: Furnish a Copy of this DWG to the installation Contractor. Failure to follow provisions of BCSI In handling and installation of trusses Can result in serious Injuries. Do not permit Inexperienced and uninstructed people to install trusses. See "WARNING" note below. BCSI recommends retaining a registered professional engineer for the design of temporary bracing. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-AE 1605 -2636 X-J 295 -94 C -AC 6576 -4182 J - W 660 - 829 AE-AC 1274 -456 W - K 1412 -718 AC -AD 89 0 W - L 769 -1050 AC- D 638 -139 L - U 523 -114 D -AB 694 -1348 U - N 717 -1348 AB-F 523 -111 N-S 638 -155 F- Z 762 -1050 S- T 89 0 G-Z 1412 -717 S-R 1349 -691 Z - H 660 -829 8-0 6576 -4141 H-X 295 -95 R-0 1792 -2636 S CUSTOMER ("BUYER') ACKNOWLEDGMENT roan. use. Unless otherMse stateE w the TOO, only Npine Ne Too in Me All tapllalized teams ere es darned In TPM. oslNloes end dudes of ft Truss Engineer is NOT Itle Job Truss Truss Type Qry Ply 07/13/2020 Al MB A07 COMN 16 1 asso 25' -}- 19'4' -{ 25' t17X8(R) �4X8 f12X4-6X8=4X8 1117X8(R H 1112X41 s 1 J K L 1112%4 M� Xfi(R) TAJ=5X6(R 5 17 G W10 N T W10 (a)AM AP (a)AS in 25X6E F o g3X6 (a) (a)=7X8(..)(e =7%6(••)IIIpX4= 6x81112x41112XI ( O\P 5%6 �H731$ A =H0714 o a) AKAL AN AO AO AR (a)AT AU a 75 oH1319D 1114XB a)W8 a)a a y IIS--4 (••) =4XII(Ai) -H1014 B2 AF AE AD AC AB AA Z Y X B2 V -4);6(A7) At pGAH =7X8 =fiXfi =4X8 =1­10710 -4X8=6X6=7X8 W 11 U =10X14 103X6 1113X6 =8X14 SEAT PLATE REQ. SEAT PLAJ2� RED. 654' { 51.4- 6--{ 6B'4' Loading Criteria (ps6 Wind Criteria Code / Misc Criteria DeflICSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Bid; ASCE 7-10 Code: FBC 2017 RES PP Deflection In Ioc Udell L#1 Gravity Non -Gravity TCOL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): 0.818 J 944 386 LOG R+ / R- / Rh l Rw l U I RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Varies by Ld C stRT(CL): 1.366 J 565 386 AX 3747 /- /- 12028 11482 1524 BCDL: 10.00 Risk Category: ll FT/RT:10(0)/10(10) HORZ(LL): 0.391 U - - U 3712 !- /- /2013 11469 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.653 U - - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 28.00 ft WAVE, HS Creep Factor: 2.0 AX Brg Width = 8.0 Min Req = 3.1 NCBCLL: 10.00 TCDL: 5.0 psf Max TC CSI: 0.951 U Brg Width = 8.0 Min Req = 3.1 Load Duration: 1.25 BCDL: 5.0 psf Max BC CSI: 0.597 Bearings AX & U are rigid surface. Spacing: 24.0' MWFRS Parallel Dist: h/2 to h Bearings AX 8 U require a seat plate. C&C Dist a: 6.93 it Max Max Web CSI: 0.993 Top Chord Forces Per Ply (Ibs) dwa Lac. from enwalnot in 17.00 ft Wgt: 626.6 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEWVer. 19.01.00A.Ofi18.15 A-B 58 0 K-L 4726 -8113 Lumber Additional Notes B-C 730 -1331 L-M 2921 -6427 Top chord 2x6 SP 240of--2.OE :T5 2x6 SP #2: WARNING: Furnish a copy of this DWG to the installation con Cto DFailu 7 .1319 M - N 3074 -7091 -rE �f)-g618 N-O 3613 -7902 Bot chord 2x6 SP 2400f-2.OE :B2 2x8 SP 2400f-1.8E: follow provisions of BCSI in handling and installation of trussesn Cesult 1�1ogs.,1 injuries. Do not permit Inexperienced and uninsiruct people to illl W S747R�83 O P ,,,586 7940 Webs 2x4 SP #3:W1 2x8 SP 2400f-1.8E: "WARNING" note below. BCSI recommends retaining a registerG 9 fess�76 P Q 428g 8606 289 9606 :W2, W3, W8, W10, W11, W19, W202x4 SP#2: engineer for the design of temporary bracing. H -7083 Q- R :W4, W5, W21 2x4 SP M-30: H - I 2910 -6414 R-S 565 -992 1-1 4726-8113 S-T 58 0 Bracing J - K 4726 -8113 (a) Continuous lateral restraint equally spaced on member Special Loads -(Lumber Dur.Fac =1.25 / Plate Dur.Fac =1.25) TC: From 62 pit at -2.50 to 62 pit at 71.83 BC: From 20 plf at 0.00 to 20 plf at 69.33 PUB: From 80 pit at 25.29 to 80 plf at 32.28 PUB: From 80 pit at 32.28 to 80 plf at 44.04 Plating Notes All plates are 4X6 except as noted. (") 3 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Purling In lieu of structural panels or rigid ceiling use pudins to brace all flat TC @ 24" oc, all BC @ 60" Go. Wind Wind loads based on MWFRS with additional C&C member design. Left and right cantilevers are exposed to wind "WARNING" Please Naroughly review McW1 ROOF TRUSSES("SELLERI, GENERAL TERMS and 'edy design parameters and read notes on Nis Tmss Design Dooming (FDD) and Me specialty Engineer reference s onnecter plates shall W used far the TDD to be valid- As a Truss Design Engineering (I.e. Specialty Engineer), Me ssponsibllity for Me design of the single Truss depicted on the TDD only, under TPI4. The design assumptions, load ssponsibiliy of Me O nor, the Owners autfna i ed agent or Me Building Designer, In Me oonte d of Me IRC, Me IBC, use Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B-AI 1441 -734 AB -AA 7050 -1795 AI-AH 229 -97 AA-Z 5487 -2181 AG -Ale 9087-3713 Z-Y 4274 -2433 AF-AE 4055 -2274 Y-X 4274 -2433 AE-AD 4055-2274 X-V 8901 -3748 AD -AC 5308 -2049 W - U 280 -125 AC -AB 6998 -1738 U - S 2281 -1197 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C-AI 247 -456 J-AP 312 -285 AI-D 29M-5775 AP-L 478 -571 AI -AG 3571 -1317 AP -AS 1219 -1298 D-AG 5361 -2489 AQ-AB 17 -226 AG-AH 103 0 AQ-AR 393 -778 AG-E 934 -222 AR -AA 309 -625 E-AF 935 -2006 AR -AT 864 -771 Ale-G 413 -177 L-AS 12 -11 AF-AK 3124 -993 L-AV 1431 -1344 G-AK 817-1008 AA -AU 1150 -206 H-AJ 2179 -663 AS -AV 1219 -1298 AJ-AK 1847 -303 AT -AA 24 -239 AJ-1 1427 -1341 AT -AU 864 -771 All cePlMllud I J in wv fmn Is Truss Truss Type Qty Ply 07/13/2020 3550 A07 COMN 116 1 "WARNING^ PI... AJ-AM 1206 -1287 AU-Z 209 -1444 AK -AD 945 -78 AU-AW 2322 -1116 AK -AL 2547 -954 Z-AW 907 -78 AD -AL 198 -1502 AV-AW 1851 -305 AL -AC 1220 -199 AV-M 2184 -666 AL -AN 754 -653 AW-N 881 -1092 1-AM 12 -11 AW-X 30M -918 1-AP 492 -583 N-X 458 -149 AC -AO 294 -699 X - P 849 -1705 AM -AP 1205 -1286 P - V 723 -165 AN -AC 16 -231 V-W 144 -3 AN -AO 754 -653 V-Q 4786 -2208 AO -AB 474 -303 V - U 3903 -1557 AO-AQ 392 -778 Q-U 2781 -5394 AB -AR 464 -308 U-R 155 -256 Ne wnn—w en Pm(I.— Job Truss Truss Type Qty Ply 07/13/2020 3568 A1MB A07A COMN 2 1 j- 25' 2 S D aT 5X8(•3X10G c E �H0714D S6X10C 4 -G =4X�(A7)a =_H1014 B2 -C AK AIAJ 1115X8(")a5X14 1113X6 SPLATE REO. �- 12'3' 3004 P 19'4' -{ 25' -1 %7X8(R) a4X8 112X4a6%8=4X8 97X8(R A I__SX6 R J 1112x4 K L M 1112X4 N= 6(R) T2 T H O W12 (a) AP a6X10 (a)AV W22 O (a) (e) h a6X10('•) (a is 0 a •• 1112X4_ 1112X4 AZ QkSX6 _ AN AO a AO AR A a AW AX =H0714 .- e a W10 R35X141114X70(") Safi%i6 AH AG AF AE AD AC AS AA Z B2 X Ta4X�(A1) -7X8 =fiX6 �4%8 aH0710 a4X6 -6 _fiX10 y 111 W6 SEAT PLATE REG. 65'4' 694' 5T1' Loading Criteria (Ps0 Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection In loc Udefl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): 0.818 K 949 388 Loc R+ / R- / Rh / RW / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: No VERT(CL): 1.420 K 546 388 AL 3984 J. 1- /2271 11476 /524 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.366 V - - V 3776 /- /- /2063 /1476 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.635 V - - Wind reactions based on MWFRS Des Ld: 40.00 Mean Height: 28.00 it WAVE, HS Creep Factor: 20. AL Br Width = 8.0 Min Re 3.3 NCBCLL: 10.00 TCDL: 5.0 psf Maz TC CSI: 0.923 V Erg Width = 8.0 r9 Min Re 4.5 Load Duration: 1.25 BCDL: 5.0 sf P Max BC CSI: 0.995 Bearings AL & V are rigid surface. . Spacing: 24.0 ° MWFRS Parallel Dist: hY2 to h i Bearings AL & V require a seal plate. C8C Dist a: 6.93 ft Max Web CSI: 0.995 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 17.00 ft Wgt: 627.2 Ibs Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Wind Duration: 1.60 VIEW Ver. 19.Oi.00A.0618.15 A-B 58 0 K-L 4756 -8312 Lumber Additional Notes B - C 752 -1319 L- M 4766 -8312 CD 1687 -4124 M - N 2944 -6605 Top chord 2x6 SP 2400f-2.OE :T2 2x6 SP #2: (•°•) 20 gage metal shim required between chord ends to distrib e lal f A224 N - O 3103 -7325 Bot chord 2x6 SP 2400f-2DE :B2 2x8 SP joint. E • F 4610-11170 O - P 3642 -8079 2400f-1.8E: :B4 2x6 SP #2: The maximum horizontal reaction is 524# F - G 4616-11129 P - Q 3615 .8117 Webs 2x4 SP #3:Wl 2x8 SP 2400f-1.8E: WARNING: Furnish a copy of this DWG to the installation contralSteiHFailu8623 -8408 Q - R 4368 -9903 :W2, W5, W6, W10, W12, W13, W21 2x4 SP #2: follow provisions of BCSI in handling and installation of trusses can result i0193rie9331 R - S 1680 -3838 :W4, W22 2x4 SP M-30: injuries. Do not permit inexperienced and uninstructed people toliarAall bump( S@%g S - T 756 -1310 'WARNING" note below. BOSI recommends retaining a registerectlKofessi" .8312 T - U 58 0 Bracing engineer for the design of temporary bracing. (a) Continuous lateral restraint equally spaced on member. Maximum Bat Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. Special Loads -(Lumber Dur.Fac =1.25 / Plate Dur.Fac =1.25) B -AL 1444 -760 AD -AC 7181 -19N TC: From 62 plf at -2.50 to 62 plf at 71.83 AL -AK 1240 -376 AC -AB 5416 -2316 BC: From 20 plf at 0.00 to 20 plf at 69.33 AK-AJ 156 -78 AB -AA 4139 -248B PLB: From 80 plf at 25.29 to 80 plf at 32.28 AI-AH 8853 -3357 AA-Z 4139 -2488 PLB: From 80 plf at 32.28 to 80 pit at 44.04 AH-AG 4674 -2370 Z - X 9124 -3799 BC: 300 lb Conc. Load at 12.25 AG-AF 4673 .2370 Y- W 177 -81 AF-AE 5647 -2130 W - V 1245 -613 Plating Notes AE-AD 7343 -1799 V - T 1430 -763 All plates are 4X6 except as noted. (") 4 plate(s) require special positioning. Refer to scaled plate plot details for Maximum Web Forces Per Ply (Ibs) special positioning requirements. Webs Tens.Comp. Webs Tens. Comp. Purlins AL-C 2030-3777 AD -AU 630 -315 In lieu ofstructural panels or rigid ceiling use pudins to brace all flat TC @ 24" cc, C -AK 3758 .1999 AS- M 491 -574 all BC @ 60" oc. AK- D 1437 -3362 AS -AV 1178 -1277 AK -AI 3993 -1399 AT -AD 17 -227 Wind D-AI 6439-2506 AT -AU 393 -784 Wind loads based on MWFRS with additional C&C member design. E -Al 177 -61 AU -AC 308 -742 Left and right cantilevers are exposed to wind AI-AJ 86 -10 AU-AW 982 -790 AI-G 2115 -742 M-AV 12 .11 G -AH 615 -1408 M -AY 1435 -1348 AH-H 858 -236 AC-AX 1262 -276 AH-AN 3063.1063 AV -AY 1178 -1277 H-AN 834-1351 AW-AC 25 -243 '•WARNING" Please thoroughly raNm the 'A-1 ROOF TRUSSES('SELLER'), GENERAL TERMS and CONDITIONS CUSTOMER('BUYER) ACxNOWLEDGMENP farm Job AlMB I NSS B01 I was I ype EJAC Uly I Vly Ulf I-nLULU 42 1 2574 1 Loading Criteria (p rI TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Sld: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 28.00 It TCDL: 5.0 psf BCDL: 5.0 lost MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpI: 0.18 Wind Duration: 1.60 SEAT RAZE REd —r'j Code I Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0y10(10) Plate Type(s): WAVE Top chord 2x6 SP 2400f-2.0E Bot chord 2x4 SP 2400f-2.OE :B2 2x4 SP #2: Webs 2x4 SP #3:W1 2x6 SP #2: Hangers I Ties (J) Hanger Support Required, by others Purlins In lieu of rigid ceiling use purlins to brace BC Q 60" oc. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. "WARNING- Please �edfy design parameters and 1 Deb/CSI Criteria ♦ Maximum Reactions (Ibs) PP DeOeclion in loc Udell L/# Gravity Non -Gravity VERT(LL): -0.204 H 627 240 Loc R+ / R- / Rh / Rw / U / RL J 845 /- /- /660 1394 1319 VERT(CL): 0.471 H 271 180 HORZ(LL):-0.140 E - - G 408 /- /- /217 1209 /- HORZ(TL): 0.302 E - - Wind reactions based on MWFRS Creep Factor: 2.0 J Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.467 G Brg Width = - Min Req = - Max BC CSI: 0.267 Bearing J is a rigid surface. Max Web CSI: 0.299 Bearing J requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 67.2 lbs Chords Tens.Comp. Chords Tens. Camp. VIEW Ver. 19.01.00A0618.15 A-B 55 0 D-E 6 -192 B-C 80 -398 E-F 134 -163 C-D 0 -230 TERMS and CONDITIONS CUSTOMER Maximum got Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Camp. B-J 449 -65 H-G 0 0 J -1 22 -20 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-J 737 -689 H-1 112 -3 E-H 185 0 F-G 378 -348 In wignp by all pelves involved. Job A1MB Loading Criteria (psi) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0 ° Truss B01A Wind Criteria Wind Std: ASCE7-10 Speed: 160 mph Enclosure: Closed Risk Category. II EXP: C Kzt: NA Mean Height: 28.00 It TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: h/2 to It C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 - Lumber Top chord 2x6 SP 2400f-2.0E :T2 2x6 SP #2: Bot chord 2x4 SP #2 :132 2x6 SP #2: Webs 2x4 SP #3 :W1 2x6 SP #2: :W2 2x4 SP M-30: Special Loads —(Lumber Dur.Fac. 1.25I Plate Dur.Fac. 1.25) TC: From 62 plf at -2.50 to 62 plf at 13.00 BC: From 20 plf at 0.00 to 20 plf at 13.00 BC: 300 lb Conc. Load at 12.06 Hangers I Ties (J) Hanger Support Required, by others Purlins In lieu of rigid ceiling use During to brace SC @ 60" oc. Truss Type EJAC Qty Ply 07/11/2020 4 1 F i c J 2577 12M11 114 3004' Code / Miss Criteria Defl/CS1 Criteria ♦ Maximum Reactions (Ibs) Code: FSC 2017 RES PP Deflection In loc Udell L#t Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.095 J 294 240 Loc R+ / R- / Rh l Rw I U / RL Rep Factors Used: No VERT(CL): 0.174 H 737 180 J 871 /- /- 7703 /680 1319 FT/RT:10(0)/10(10) HORZ(LL):-0.058 G - - G 681 /- 1- /473 /209 /- Plate Type(s): HORZ(TL): 0.143 G - - Wind reactions based on MWFRS WAVE Creep Factor. 2.0 J Brg Width = 8.0 Min Req = 1.6 Max TC CSI: 0.480 G Erg Width =- Min Req = - Max BC CSI: 0.526 Bearing J is a rigid surface. Max Web CSI: 0.621 Bearing J requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 77.0 lbs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 AIB 55 -62 D-E 104 -300 B - C 73 -465 E - F 263 -520 C - D 226 -407 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-J 499 -136 H-G 12 -15 J -1 267 -195 Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Additional Notes The maximum horizontal reaction Is 442# Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - J 760 -697 H - F 596 -429 E-H 349 -248 F-G 378 -387 H-1 104 -23 s thoroughly review the -A-1 ROOF TRUSSES (°SELLER°), GENERALTERMS and CONDITONS CUSTOMER ('BUYER') ACKNOwLEDGMENr roan. id mad notes on this Truss Design Drewing (TDD) and the Spedalty, Engineer reference sheet before use. Unless othenuse slated on the TOD. only Alpine ed for the TDD to be valid. As a Trvu Design Engineering as. spedalty, Engineer), the seal on any TDD represents an acceptance of the pmfessional enowarl of Ne single Truss depided on the Too only. under TPI-1. The design assumptions, loading cond'Nons, suitability and use of this Truss for any Building Is the the Owners authorized agent orthe Building Designer, In the context of the IRC, the IBC. Jowl building onto and TPI-1. The approval of the TDD and anygeid Job Al MB Truss Truss Type City Ply B02 JACK 4 1 07/11/2020 2586 Loading Criteria (psq TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Sparing: 24.0" Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 28.00 ft TCDL: 5.0 psf BCDL: 5.0 psi MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not In 9.00 GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP 2400f-2.OE :T2 2x6 SP #2: Bot chord 2x4 SP #2 :B2 2x6 SP 2400f-2.OE: Webs 2x4 SP #3 :W 1 2x6 SP #2: 02 2x6 SP 2400f-2.OE: Special Loads —(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25) TC: From 62 plf at -2.50 to 62 pit at 13.00 BC: From 20 plf at 0.00 to 20 pit at 13.00 BC: 1062 Ib Conc. Load at 11.10 Hangers I Ties (J) Hanger Support Required, by others eFAT MIEPEO. I--Y�11 1-1'1m4-i IN" Code I Misc Criteria DeflICSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in loc Udell L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.169 J 165 240 Loc R+ / R- / Rh / Rw / U / RL J 1035 /- /- 1- 1904 /- Rep Factors Used: Vedas by Ld C 16PERT(CL): 0.189 J 147 180 FT/RT:10(Ov10(10) HORZ(LL): 0.079 C - - G 1280 /- /0 /- /1176 /0 Plate Type(s): HORZ(TL): 0.088 C - - Wind reactions based on MWFRS WAVE Creep Factor. 2.0 J Brg Width = 8.0 Min Req = 1.5 Max TC CSI: 0.572 G Big Width = - Min Req = - Max BC CSI: 0.756 Bearing J is a rigid surface. Bearing J requires a seal plate. Max Web CSI: 0.424 Maximum Top Chord Forces Per Ply (Ibs) Wgt: 80.5 lbs Chords Tens.Comp. Chords Tens. Comp. VIEWVer. 19.01.00A.0618.15 A-B 55 -63 D-E 37 -38 B-C 368 -528 E-F 12 -12 C-D 581 -710 Purlins In lieu of structural panels or rigid ceiling use pudins to brace all flat TIC @ 24" oc, all BC @ 60" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Maximum got Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-J 594 -451 H-G 882 -679 J -1 532 -379 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-J 878 -833 D-G 761 -994 H-1 118 0 F-G 220 -224 H - D 560 -422 ACKNOw EDGMENPform. ie BuildIng Designerand Contractor. All notes sel out In the TDD and the pre fenanoadforgeneralguldanm. TPN tlaRrea Ne responvbTdas endtlWes ed upon in wddng by all parties lnv Ned. The Spedalry Engineer is NOT the 1. wnia�uu bl.l Rm(Thnm Truss Job A1MB Truss Truss Type Qty Ply 07/11/2020 FL01 SY42 I14 1 3062 �o =3X4 �8x12 A B AB AA Z III1.5X3 =7X10 4"8 Loading Criteria fp30 Wind Criteria TCLL: 125.00 Wind Std: NA TCDL: 10.00 Speed: NA mph BCLL: 0.00 Enclosure: NA BCDL: 12.00 Category: NA EXP: NA Kzt: NA Des Ld: 147.00 Mean Height: NA ft NCBCLL: 0.00 TCDL: NA psf Load Duration: 1.00 BCDL: NA psf Spacing: 24.0" MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Lumber Top chord 4x2 SP M-30 :T3 4x2 SP 2400f-2.OE :T4 4x2 SP #2: got chord 4x2 SP M-30 Webs 4x2 SP #3 :W 1, W2, W5 4x2 SP 42: :Lt Bearing Leg 4x2 SP #3: At Bearing Leg 4x2 SP #3: Plating Notes All plates are 3X6 except as noted 16'9"12 --4X8 U12X4 =3X3 �5X8 C D E F 30' =5X70 112X4 W=3X6 MX6(R) =5X8 1112X4 =3X3=7XIO G H I J K L M N O "�,}��'m�I i� In Illr�,l� Y X W V iU T =3X10 �4X6 W=H0308 =5X8=6X6 =5X12 17' Code I Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Varies by Ld FT/RT:10(OU10(10) Plate Type(s): WAVE, HS Loading Truss checked for 200# live and 0# dead movable load along Top Chord, non -concurrent vrith any other live loads. Purlins In lieu of rigid ceiling use puriins to brace BC @ 60" oc. Additional Notes + 2x6 continuous strongback. Truss must be installed as shown with top chord up. reWew Me •A-1 ROOF TERMS 30' Deb/CSI Criteria PP Deflection in loc L/dell Lf# VERT(LL): 0.328 D 618 481 4�RT(CL): 0.405 D 501 361 HORZ(LL): 0.126 B - - HORZ(TL): 0.154 B - - Creep Factor. 2.0 Max TC CSI: 0.819 Max BC CSI: 0.782 Max Web CSI: 0.998 Wgt: 193.2 Ibs VIEW Ver. 19.01.00A.0618.15 4"8 13, ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL AS 2231 /• /- /- /- /- U 5253 !- 1- l- I• l- P 1717 /-103 /-/- AS Brg Width =3.0 Min Req =3.0 U Brg Width = 8.0 Min Req = 2.7 P Brg Width = 3.0 Min Req = 3.0 Bearings AS, U. & P are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 0-1829 H-1 630 -1005 B- C 0 -1808 1-1 3326 0 C-D 0-4390 J-K 2157 0 D- E 0 -4390 K- L 838 -2589 E- F 0 -4194 L- M 838 •2589 F - G 630 -1006 M - N 103 -1342 G - H 630 -1006 N - O 103 -1364 Maximum got Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp AA-Z 85 0 V-U 0 -3126 Z-Y 3559 0 U-T 0 -2197 Y- X 4246 0 T- S 1727 -1469 X- W 3056 -212 S - R 2430 -433 W-V 3056 -212 R-Q 63 -4 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A -AB 0 -982 I-U 0 -3013 A-Z 2814 0 U-J 0 -2517 AB -A 0-1339 J-T 1697 0 AB -AA 0 -14 T-K 0 -2707 B-Z 0 -771 K-S 1589 0 Z-C 0-2196 L-S 0 -648 C-Y 1042 0 S-M 200 -508 D-Y 0 -653 M-R 413 -1364 Y-E 330 -77 R-N 0 -726 E- X 0 -886 R- O 2097 -159 X-F 1590 0 P-Q 0 -8 F-V 0-2728 P-O 46 -758 G-V 0 -705 O-P 60 -1026 V -1 42D4 0 M. Job Truss A1MB HC5' T CO �o Truss Type Oty Ply 07/11/2020 3219 SPEC 40 1 f l � 12 3.54 B Loading Criteria (,0 Wind Criteria Code / Misc Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 150 mph TPI Sid: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes BCDL: 10.00 Risk Category. ll FT1RT:10(Ov10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 40.00 Mean Height: 28.00 ft NCBCLL: 0.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psi Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Top chord 2x4 SP 42 Bot chord Purlins In lieu of rigid ceiling use puriins to brace BC @ 60' oc. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Shim all supports to solid bearing. ^WARNING^ 219115 Deg/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc L/defl LJ# Gravity Non -Gravity VERT(LL): 0.000 - - 240 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.000 - - 180 A 113 /- 1- 160 158 157 HORZ(LL):-0.000 B - - B 113 /- 1- /61 777 /- HORZ(TL): 0.000 B - - Wind reactions based on MWFRS Creep Factor: 2.0 A Brg Width = 1.5 Max TC CSI: 0.282 B Brg Width = 1.5 Max BC CSI: 0.000 Maximum Top Chord Forces Per Ply (Ibs) Max Web CSI: 0.000 Chords Tens.Comp. Wgt: 4.2lbs A-B 32 -76 VIEW Ver. 19.01.00A.0618.15 bye aor. All notes set TPI-1 defines the Job Al MB Truss HA 1 Truss Type MONO Qty 4 11y I 07111Y2020 2547 158M i15f4--nr 5�T5'1521 574 15'8T srwrrureaan '�zaa-�-1Tae� .2310 Loading Criteria t on Wind Criteria Code I Misc Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 Code: FBC 2017 RES TCDL: 10.00 Speed: 160 mph TPI Std: 2014 BCLL: 0.00 Enclosure: Closed Rep Factors Used: Varies by Ld BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) EXP: C Kzt: NA Plate Type(s): Des Ld: 40.00 Mean Height: 28.00 R WAVE NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 If Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Top chord 2x6 SP 2400f-2.OE :T2 2x6 SP #2: Bat chord 2x4 SP 2400f-2.0E 32 2x6 SP #2: Webs 2x4 SP #3 :Wi 2x6 SP #2: :W5 2x4 SP M-30: Special Loads -(Lumber Dur.Fac =1.251 Plate Dur.Fac=1.25) TC: From 61 pIf at -3.41 to 61 plf at 1.46 TC: From 30 plf at 1.46 to 30 plf at 9.94 TC: From 61 plf at 9.94 to 61 plf at 15.55 BC: From 10 plf at 0.00 to 10 pif at 9.94 BC: From 20 pIf at 9.94 to 20 plf at 15.55 TC: 378 lb Conc. Load at 1.46 TC: -536 Ito Conc. Load at 4.29 TC: -65 lb Conc. Load at 7.12 TC: 157lb Conc. Load at 9.94 BC: 82 lb Conc. Load at 1.46 SC: -231 lb Conc. Load at 4.29 BC: 17 lb Conc. Load at 7.12 BC: 1191b Conc. Load at 9.94 BC: 455 lb Conc. Load at 12.76 Hangers / Ties (J) Hanger Support Required, by others Purlins In lieu of rigid ceiling use pudins to brace BC @ 60" oc. Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. "WARNING' TPI and 1-T,s--I r zirl. A 4W DeflICSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection In loc Udefl L/# Gravity Non -Gravity VERT(LL): -0.197 1 748 240 Loc R+ I R- / Rh / Rw / U / RL L 808 /- /- /- 15154 1- ,�15RT(CL): 0.157 1 939 180 H0RZ(LL):-0.184 H - - H 739 I- /0 !- 1839 /0 HORZ(TL): 0.187 H - - Wind reactions based on MWFRS Creep Factor: 2.0 L Brg Width = 11.3 Min Req = 1.5 Max TC CSI: 0.589 H Brg Width = - Min Req = - Max BC CSI: 0.706 Bearing L is a rigid surface. Max Web CSI: 0.949 Bearing L requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wg1: 102.2 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 19.01.00A.0618.15 A -B 55 -64 D-E 961 -301 B-C 1995 -2960 E-F 668 -518 C-D 1415 -318 F-G 40 -47 Maximum Bat Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 2597 -1859 K - J 294 -1041 L - K 1972 -1754 I - H 627 -784 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp L-C 4333 -870 J-1 164 -262 C - K 1668 -3077 I - F 386 -483 K - E 761 -451 F - H 974 -778 E-J 619 -131 G-H 176 -151 WSTOMER ('BUYER°) ACKNOWLEDGMENT farm. D. Unless othorcdse stated an the TOD, only Alpine J represents an acceptance of the professional engineed suitability and use of Nis Truss forany Building Is Me sxIi TPl-i. Theepanselof Ale TDDandenyfieid tor. All notes set out in the Too and no pootims and TPI.1 defines to responsibilities and duffles of the Tmss 111 RxJ1-- Job Truss Truss Type Ury Ply U11111202U Al MB J 1 JACK 8 1 2522 T 6"3 Loading Criteria Ipe9 Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 28.00 it NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 6.0 psf Spacing: 24.0" MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpl: 0.18 Wind Duration: 1.60 12 C 5 =2 4(A1l i 2r6" Code I Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Lumber Top chord 2x6 SP #2 Bot chord 2x4 SP #2 Purlins In lieu of rigid ceiling use pudlns to brace BC @ 60" Do. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes The maximum horizontal reaction is 683# ""' BEARING ANALOG MODIFIEDI ••••• [3 / 1 Deft/CSI Criteria A Maximum Reactions (Ibs) PP Deflection in loc Udefl L#t Gravity Non -Gravity VERT(LL): 0.000 - - 240 Loc R+ / R- / Rh / Rw / U / RL VERT(CL): 0.000 - - 180 D 41 /- /683 /34 /32 /821 HORZ(LL): 0.000 - - - C 189 /- /683 /152 /176 (/15 HORZ(TL): 0.000 - - - Wind reactions based on MWFRS Creep Factor. 2.0 D Brg Width = 1.5 Max TC CSI: 0.601 C Big Width = 1.5 Max BC CSI: 0.223 Maximum Top Chord Forces Per Ply (Ibs) Max Web CSI: 0.000 Chords Tens.Comp. Chords Tens. Comp. Wgt: 9.8 lbs A-B 55 0 B-C 700 -2598 VIEW Ver. 19.01.00A.0618.15 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 29M -684 IER CBU W) ACKNOWLEDGMENT' farm. oNenxise slalel an the MD. onW Koine TDD only, under TPI-1 e BuDding Designer in Job Al MB Truss J10 Truss Type JACK City 11y 07/11/2020 2538 Loading Criteria lrsq TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0' Wind Criteria Wind Sld: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzb NA Mean Height: 28.00It TCDL: 5.0 psf BCDL: 5.0 psi MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 It Loc. from endwall: not in 9.00 GCpI: 0.18 Wind Duration: 1.60 Lumber Top chord 2x6 SP 240Gf-2.OE Bot chord 2x4 SP #2 Webs 2x4 SP #3:W1 2x6 SP #2: Hangers I Ties (J) Hanger Support Required, by others Purlins In lieu of rigid ceiling use pudins to brace BC @ 60" oc. PLATE REQ. 11'1" 4 Code / Mlsc Criteria Def11CSl Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection In too Udell L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.135 1 206 240 Loc R+ / R- / Rh / Rw / U / RL 1 782 /- /- 1629 1485 1439 Rep Factors Used: Yes VERT(CL): 0.152 1 184 180 FT/RT:10(Op10(10) HORZ(LL):-0.079 D - - F 323 /- /- /171 /289 !- Plate Type(s): HORZ(IL): 0.105 D - - Wind reactions based on MWFRS WAVE Creep Factor. 2.0 1 Brg Width = 8.0 Min Req = 1.5 Max TCCSI: 0.427 F Brg Width= - Min Req=- Max BC CSI: 0.451 Bearing I is a rigid surface. Max Web CSI: 0.195 Bearing I requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 62.3 Ibs Chords Tens.Comp. Chords Tens. Comp. VIEW Ver. 19.01.00A.0618.15 A-B 55 0 C-D 13 -191 B-C 81 -368 D-E 88 -112 Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-I 411 -62 G-F 18 -17 I-H 29 -21 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Camp. C-1 760 .619 G-H 109 0 D- G 137 0 E- F 305 -270 Na Too In Ue Job Truss Truss Type Qty Ply 07/11/2020 Al MB J3 I JACK 8 1 2524 Loading Criteria (psq TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL: 10.00 Load Duration: 1.25 Spacing: 24.0" Top chord 2x6 SP #2 got chord 2x4 SP #2 Webs 2x4 SP #3 12 1113X10C 5 p 2X4(A1 B HB e 1 A 1113X6(") E F SEAT PLATE REQ. �— 2' i 2'6" 2'3"8 1 8"8 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 28.00 ft TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: not in 4.50 GCD: 0.18 Wind Duration: 1.60 f - 3' -{ Code / Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Plating Notes Plates extending outside the truss perimeter shall be positioned within the tolerance specified on the plate placement polygon only, without use of TPI 1-2007 section 3.7.2.2 alternate positioning. Steel extending above the top chord or below the bottom chord may be trimmed or folded along the outer edge of that chord. Steel extending elsewhere beyond outermost truss members may be folded. ("")1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning requirements. Putting; In lieu of rigid ceiling use purlins to brace BC @ 60" oc. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes Negative reaction(s) of-732# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. DeflICSI Criteria PP Deflection in loc L/defl L/# VERT(LL): -0.099 F 277 24( VERT(CL): 0.127 F 215 18( HORZ(LL): 0.047 D - - HORZ(TL): 0.060 D - - Creep Factor: 2.0 Max TC CSI: 0.710 Max BC CSI: 0.732 Max Web CSI: 0.624 Wgt: 18.21bs VIEW Ver: 19.01.00A.0618.15 fi ♦ Maximum Reactions (Ibs) Gravity Nan -Gravity Loc R+ 1 R- / Rh / Rw / U / RL F 1401 /- /- /1427 11246 /169 E - /489 /- /299 1330 /- D - /-732 I- 1683 f753 /- Wind reactions based on MWFRS F Big Width = 8.0 Min Req = 1.7 E Brg Width =1.5 Min Req = - D Big Width = 1.5 Min Req = - Bearing F is a rigid surface. Bearing F requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 55 0 C-D 546 -296 B-C 116 -219 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-F 302 -83 F-E 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C-F 1801 -991 "WARNING" Please thoroughly reNew the "A-1 ROOF TRUSSES ("SELLER'), GENERALTERMS and CONDITIONS CUSTOMER (-BUYER') ACKNOWLEDGMENT' forth. only design parameters and read notes on this Truss Design Drewing (MD) and the Specialty Engineer reference sheet before use. Unless oNervise stated on the MD. only Npine tg by ell pelves Involved. The Job Al MB Truss J5 Truss Type EJAC Cry Ply 8 1 07/11/2020 2541 i SEAT PLATE REQ. �2� 1 2'6" -'-i 2'6"12 i 2'5"4 Loading Criteria(paq Wind Criteria TCLL: 20.00 Wind Std: ASCE 7.10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt NA Des Ld: 40.00 Mean Height: 28.00 ft NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 5.0 psf Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not In 4.50' GCpi: 0.18 Wind Duration: 1.60 Top chord 2x6 SP 2400f-2.OE Bol chord 2x4 SP #2 Webs 2x6 SP #2 Purlins In lieu of rigid ceiling use purling to brace BC @ 60" oc. i 5' A Code I Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FBC 2017 RES PP Deflection in too Vdefl L/# Gravity Non -Gravity TPI Sid: 2014 VERT(LL): -0.100 F 305 240 Loc R+ / R- / Rh / Rw / U / RL G 797 /- /- 1746 /583 /236 Rep Factors Used: Yes VERT(CL): 0.140 F 218 180 FT/RT:10(0)/10(10) HORZ(LL): 0.046 D - - E 9 1-45 /• /75 /56 /- Plate Type(s): HORZ(TL): 0.065 D - - D - /-244 /- /230 /275 /- WAVE Creep Factor: 2.0 Wind reactions based on MWFRS Max TC CSI: 0.343 G Brg Width = 8.0 Min Req = 1.5 Max BC CSI: 0.469 E Brg Width = 1.5 Min Req = - Max Web CSI: 0.200 D Brg Width = 1.5 Min Req = - Bearing G is a rigid surface. Wgt: 28.0 Ibs Bearing G requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. A-B 55 0 C-D 175 -133 B-C 184 -385 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-F 444 -138 F-E 0 0 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Additional Notes C-F 1017 -632 Negative reaction(s) of -244# MAX. from a non -wind load Case requires uplift connection. See Maximum Reactions. '"WARNING- Please thoroughly review the"A-1 ROOF TRUSSES CSELLER'), GENERAL TERMS and CONDITIONS CUSTOMER("BUYER") ACKNOWLEDGMENT' form. Verity design parameters and need notes antis Truss Design Drawing (TDD) and the Specialty Engineerreference sheet before use. Unless othervdse stated on the TDD, only Alpine connector plates shall be used forthe TOO to be void. As a Truss Design Engineering fie. Specialty Engineer), to seal on any Too represents an accoplance of the professional engineer responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use Athis Truss for any Building Is the responsibliity, of the Cwner, the Cvmefs su0omed agent or the Building Designer, In the content of the IRC, the IBC, local building code and TPI4. The approval of the TDD and anyfield use of to Truss, Including handling, storage, Installation and bracing shall be the responsibility of the Building Designer and Contactor. NI notes set out in the TOD end the pmews end guidelines ofthe Building Component Safety Womation(BSCI) published by TPI and SECA are referenced for general guidance. TPI-1 defines the responsibilifies and dues of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless aNenvise defined by a Contract agreed upon In writing by all parties involved. The Spedaity Engineer Is NOT be BWddngrCochiner or Truss System Engineer of any building. Mrapltallzetlteaµreasdefinedin TPI-1. A "m4 xM11>n1e lRmfTn�amn_ rl".rem 1.nurvm 1.n , Mwlhrv,I a-."nhmnwrmi.—MG.IRmII-- Job Truss Trl Type ury Hly Al MB J7 JACK 8 1 2526 " T 1 SEAT PLATE REQ. 2- ---i 1 2'6" i 2'6"12 7' 4'5"4 0 Loading Criteria (petl Wind Criteria Code / Misc Criteria Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection In loc Udefl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): -0.125 F 245 240 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.177 F 173 180 G 726 /- /- /638 1476 1302 BCDL: 10.00 Risk Category: Il FT/RT:10(0)/10(10) HORZ(LL): 0.058 D - - E 60 /- /- /50 /14 /- EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.082 D - - D 78 /-99 /- /110 /146 /- Des Ld: 40.00 Mean Height: 28.00 ft WAVE Creep Factor: 2.0 Wind reactions based on MWFRS NC13CLL: 10.00 TCDL: 5.0 sf p Max TC CSI: 0.448 G Brg Width =1.5 Min Req = 1.5 Load 1.25 " BCDL: 5.0 psf Max BC CSI: 0.614 E Erg Width = 1.5 Min Req = - 2.Duration: Spacing: Spacing: 24.0 MWFRS Parallel Dist: 0 to hl2 D Erg Width = 1.5 Min Req = - C&C Dist a: 3.00 ft Max Web CSI: 0.196 Bearing G is a rigid surface. Loc. from endwall: not in 9.00 Wgt: 37.1 Ibs Bearing G requires a seat plate. GCpi: 0.18 Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 VIEW Ver. 19.01.00A.0618.15 Chords Tens.Comp. Chords Tens. Comp. Lumber A - B 55 0 C - D 72 -110 Top chord 2x6 SP 2400f-2.OE B - C 164 -429 got chord 2x4 SP #2 Webs 2x6 SP #2 Maximum got Chord Forces Per Ply (Ibs) Purling, Chords Tens.Comp. Chords Tens. Comp. In lieu of rigid ceiling use puriins to brace BC Q 60" oc. B - F 483 -144 F - E 0 0 Wind Wind loads based on MWFRS with additional C&C member design. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp: C-F 850 -572 foam. be the responslbllity of the Building Designer and Contractor. All notes set out In Ne TDD and the pmdlws and by TPl and SBOAamonfemnced forganerel guidance. TPI-1 defines the reeponsibllifies and duties ofthe Truss fined bya Contract agreed upon in writing by all paNas Involved. The Speclalty Engineer Is NOT the oars areas dented h TP61. Job Al MB Loading Criteria (ps8 TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 40.00 NCBCLL' 10.00 Load Duration: 1.25 Spacing: 24.0" Truss Truss Type J9 MONO Wind Criteria Wind Std: ASCE7-10 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt NA Mean Height: 28.00It TCDL: 5.0 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 it Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Top chord 2x6 SP 2400f-2.OE Bot chord 2x4 SP #2 Webs 2x6 SP #2 :W2 2x4 SP #3: Purllns In lieu of rigid ceiling use pudins to brace BC Q 60" oc. SEAT PLATE REQ. Oly Ply 07111121121 8 1 s'1r1a � 8'11'12 i 2544 Code I Misc Criteria De0/CSI Criteria ♦ Maximum Reactions (Ibs) Code: FSC 2017 RES PP Deflection in too L/de8 L/# Gravity Non -Gravity TPI Sld: 2014 VERT(LL): -0.125 F 221 240 Loc R+ / R- I Rh / Rw / U I RL F 723 /- /- /606 /459 1369 Rep Factors Used: Yes VERT(CL): 0.164 F 169 180 FT/RT:10(0Y10(10) HORZ(LL): 0.059 D - - D 227 /- f- /119 1191 /- Plate Type(s): HORZ(TL): 0.078 D - - Wind reactions based on MWFRS WAVE Creep Factor: 2.0 F Big Width = 8.0 Min Req = 1.5 Max TC CSI: OA09 D Big Width = 1.5 Min Req = - Max BC CSI: 0.478 Bearing F is a rigid surface. Max Web CSI: 0.180 Bearing F requires a seat plate. Maximum Top Chord Forces Per Ply (Ibs) Wgt: 49.7 lbs Chords Tens.Comp. Chords Tens. Camp. VIEWVer: 19.01.00A.0618.15 A-B 56 0 C-D 60 -157 B-C 76 -318 Wind Wind loads based on MWFRS with additional C&C member design. Maximum got Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-F 359 -56 F-E 19 -9 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C- F 777 -546 E- D 109 0 lend SBCAammlerenc fargeneralguidarc. TPI-0definm Nerespwsibllifieamdddles bye Contr deg.WuWinw tngbyellpa winvdved. The Spedalty Erowaris NOTihe e es defined in TPN. M.NM.11 ry.n.wxnn wnva�.-nN eA nmlTnn•� Job Truss Truss Type A1MB I PBO1 I GABL Qty y unnauzu 2949 S 11 9'7"6 � � s 9'7"6 D=4X4 11' i 17713 19713 Loading Criteria (pap Wind Criteria Code / Misc Criteria Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection In Ice L/defl L#f TCDL: 10.00 Speed: 160 mph TPI Sid: 2014 VERT(LL): 0.001 D 999 36 SCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL):-0.002 H 999 24 BCDL: 10.00 Risk Category: II FT/RT:10(0y10(10) HORZ(LL): 0.002 E - - EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.002 E - - Des Ltl: 40.00 Mean Height: 28.00 ft WAVE NCBCLL: 10.00 TCDL: 5.0 psf Creep Factor. 2 Load Duration: 1.25 BCDL: 2.0 psf Max TC CSI: 0. 512 Spacing: 24.0 " MWFRS Parallel Dist: h to 2h Max BC CSI: 0.113 C&C Dist a: 4.28 ft Max Web CSI: 0.137 Loc. from endwall: not in 9.00 Wgt: 64.4 lbs GCpi: 0.18 VIEW Ver: 19.01.00A.0618.15 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 2X4(A1) except as noted. Loading Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Purlins In lieu of rigid ceiling use purilns to brace BC @ 60' oc. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. "WARNING" Please thoroughly review the-A-1ROOF TRUSSES ('SELLER'), GENERAL TERMS and ♦ Maximum Reactions (Ibs), or •=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U l RL A 51 I- I- 144 /48 /115 B' 65 I- I- 143 133 1- G 51 /- /- 127 135 /- J /-268 H /-268 Wind reactions based on MWFRS A Brg Width = 8.5 Min Req = 1.5 B Brg Width = 204 Min Req = - G Big Width =8.5 Min Req =1.5 Bearings A, B, & G are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 128 -123 D-E 151 -96 B-C 89 -102 E-F 40 -59 C-D 152 -96 F-G 25 -20 Maximum Got Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-J 67 -29 I-H 82 -24 J-1 82 -24 H-F 58 -17 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C-J 461 -395 H-E 461 -395 D-1 211 -295 At o.wr".... use Job Truss Truss Type Oty I Ply 07/11/2020 A1MB PB02 GABL 2 1 2954 T11"6 3'4" - } T11"6 -i .5X6 =5X6 D E F T 12 T 5 p EliC C] V f`T lh 10 =2 A4(A1)B------------------- H=2X4(At) L K=5X6 J. c_11" i 17'0"13— 19713 Loading Criteria gasp Wind Criteria Code / Misc Criteria DefIfC81 Criteria ♦ Maximum Reactions (Ibs), or •=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Code: FBC 2017 RES PP Deflection in Ioc L/defl L/# Gravity Non -Gravity TCDL: 10.00 Speed: 160 mph TPI Std: 2014 VERT(LL): 0.029 F 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Rep Factors Used: Yes VERT(CL): 0.066 F 999 240 A 45 /- /- /35 135 194 BCDL: 10.00 Risk Category: II FT/RT:10(0)/10(10) HORZ(LL): 0.011 D - - B• 66 /- /- /43 136 /- Des Ld: 40.00 EXP: C Kzt: NA Plate Type(s): HORZ(TL): 0.025 D - - 1 45 I- /- /23 124 /- Mean Height: 28.00 ft WAVE Creep Factor. 2.0 L I-180 : to BCDL: 5.0 psf K /-144 Load Duration:n: 1.25 Load Du BCDL: 2.0 psf Max TC CSI: 0.348 J /-180 Spacing: 24.0" MWFRS Parallel Dist: h to 2h Max BC CSI: 0.128 Wind reactions based on MWFRS C&C Dist a: 4.28 ft Max Web CSI: 0.048 A Big Width = 8.5 Min Req = 1.5 Loc. from endwall: not in 9.00 Wgt: 63.0 Ibs B Brg Width = 204 Min Req = - GCpi: 0.18 1 Brg Width = 8.5 Min Req = 1.5 Wind Duration: 1.60 VIEW Ver, 19.01.00A.0618.15 Bearings A, B, 81 are a rigid surface. Lumber Maximum Top Chord Forces Per Ply (Ibs) Top chord 2x4 SP #2 Chords Tens.Comp. Chords Tens. Comp. got chord 2x4 SP #2 Webs 2x4 SP#3 A-B 104 -101 E-F 429 -294 B-C 307 -333 F-G 413 -378 Plating Notes C-D 414 -378 G-H 306 -333 All plates are 1.5X3 except as noted. D - E 429 -294 H - I 21 -17 Loading Maximum Bot Chord Forces Per Ply (Ibs) Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Chords Tens.Comp. Chords Tens. Comp. Purilns B-L 308 -216 K-J 294 -198 L-K 294 -198 J-H 308 -214 In lieu of structural panels or rigid ceiling use purling to brace all flat TC @ 24' oc, all BC @ 60' oc. Maximum Gable Forces Per Ply (Ibs) Wind Gables Tens.Comp. Gables Tens. Comp. Wind loads based on MWFRS with additional C&C member design. C - L 344 -310 J - G 344 -310 Additional Notes E-K 180 -192 See STD DETAILS for gable wind bracing requirements Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNO am and react notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise state i on to be used far rue TDD to be valid. As a Than Design Engineering I.e. Spetlalty Engineer), the seal on any TDD represents an araeptance ofthe resign of the single Truss depicted on rue TDD only, under TPl-i. The design assumptions, loading cenduces, saleability and use of this Truss for caner, the Owners eutholUed agent orthe Building Designer, in the contan of the IRC, the IBC, IOW building code and TPI-1. The appeoval of tl iding, handling. .1ange, inslaila°on and bracing shall loathe responslbliityof fie Building Deslgnerand Contractor. Al Ludes set out it om TOD a ling Component Safety lMennatian(BSCI) auldished by TPI and SBCA are referenced forgeneed guidance. TPI-1deMes Neresponalbllitiess ngineer and Truss Manufacturer,unless othenwse defined by a Contract agreed upon in welting by all parties iav .d. TheSpedalty Ergineerk use system Engineer of any building. All capitatixed terms era es defined in TP41. nl Tnww-P-nmey,m MlNa rlmmun, Nwimn c nanMN,M UNIw„Xu wlMn wnnleaMn Nl.l nmlTnc"m ",,,,o , .., ....._-- 2980 A1MB PB03 GABL 2 1 j- 5'11"6 -1 7'4" -}- 5'11"6 -j e 5X6 =5X6 12 D E F T 5 T � C G ,_`v(_, ill o as 2A(A1)B ------------ H=2X4(A1) L K=5X6 J 1'1" Loading Criteria trap Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 28.00 It NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 2.0 psf Spacing: 24.0 MWFRS Parallel Dist h to 2h C&C Dist a: 4.28 ft Loc. from endwall: not in 9.00 GCpl: 0.18 Wind Duration: 1.60 Lumber Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 1.5X3 except as noted Code I Misc Criteria Code: FBC 2017 RES TPI Std: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Loading Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Purlins In lieu of structural panels or rigid ceiling use puriins to brace all flat TC @ 24" oc, all BC @ 60' oc. Wind Wind loads based on MWFRS with additional C&C member design. Additional Notes See STD DETAILS for gable wind bracing requirements. Please tlwreughly review the "/ smeters and mad notes on this Truss shall be used for the MD in be valid. 17'0"13 19713 DeflICSI Criteria ♦ Maximum Reactions (Ibs), or •=PLF Ple Deflection in loc Udell L/# Gravity Non -Gravity VERT(LL): 0.029 F 999 360 Loc R+ ! R- ! Rh / Rw / U / RL VERT(CL): 0.065 F 999 240 A 38 /• !- 130 /26 170 HORZ(LL): 0.011 D - - B' 67 /• /- /43 /46 /- HORZ(TL): 0.025 D - - 1 38 /- /- 117 /21 1- Creep Factor. 2.0 B /-147 Max TC CSI: 0.281 L /-115 Max BC CSI: 0.130 K /-294 Max Web CSI: 0.057 J /-113 H /-145 Wgt: 61.61bs in reactions based on MWFRS A Big Width = 8.5 Min Req = 1.5 VIEW Ver. 19.01.00A.0618.15 B Big Width = 204 Min Req = - I Big Width = 8.5 Min Req = 1.5 Bearings A, B, 81 are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 77 -76 E-F 394 -317 B-C 330 -365 F-G 434 -381 C-D 404 -381 G-H 330 -365 D-E 394 -317 H-1 15 -15 TERMS and CONDITIONS C ser reverence sheet bafare use. Maximum But Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-L 326 -229 K-J 317 -219 L-K 317 -219 J-H 325 -227 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - L 245 -252 J - G 245 -252 E - K 320 -289 ACKNOWLEDGMENT' form. n..wrn.".. the Job Al MB 110 Truss PB04 �--- 3'11"6 12 =5X6 5 D C 2A(A1)B Loading Criteria (pan Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 28.00It NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 2.0 psf Spacing: 24.0" MWFRS Parallel Dist: In to 2h C&C Dist a: 4.28 it Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Top chord 2x4 SP #2 Sol chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 1.SX3 except as noted. Truss Type City I Ply 07/11/2020 GABL 2 1 11'4" III1.5X4 =5X6 E FG Code I Misc Criteria Code: FBC 2017 RES TPI Sid: 2014 Rep Factors Used: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Loading Gable end supports 8" max rake overhang. Top chord must not be cut or notched. Puriins In lieu of structural panels or rigid ceiling use pudins to brace all flat TC @ 24" oc, all BC @ 60" oc. Wind Wind loads based on MWFRS with additional CRC member design. Additional Notes See STD DETAILS for gable wind bracing requirements. 17'0"13 19'2"13 Deg/CSI Criteria PP Deflection in loc Udell L14 VERT(LL): -0.008 F 999 36( VERT(CL): 0.011 F 999 24( HORZ(LL):-0.003 J - - HORZ(TL): 0.004 D - - Creep Factor. 2.0 Max TC CSI: 0.424 Max BC CSI: 0.117 Max Web CSI: 0.074 Wgt 60.2 Ibs VIEW Ver. 19.01.00A.0618.15 TERMS and CONDITIONS CI eer reference sheet before use. '.ngineerl, the seal an any Too 3'11"6 1'1" 2983 ♦ Maximum Reactions (Ibs), or`-PLF Gravity Non -Gravity Loc R+ IR- /Rh /Rw I IRL A 37 /- /- 128 /32 145 B• 67 /- I- /43 /53 I- 1 37 /- /- /14 131 /- L /-181 K 1-434 J /-180 Wind reactions based on MWFRS A Erg Width = 8.5 Min Req = 1.5 B Brg Width = 204 Min Req = - I Erg Width = 8.5 Min Req = 1.5 Bearings A, B, & I are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 53 -52 E-F 189 -126 B-C 158 -149 F-G 241 -183 C-D 242 -183 G-H 157 -149 D-E 189 -126 H-1 17 -14 Maximum got Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-L 138 -123 K-J 125 -112 L-K 126 -112 J-H 138 -123 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - L 256 -277 J - G 256 -2T7 E - K 459 -403 ACKNOWLEDGMENT"(ortn. A L.IPMTniaar Truu Job A1MB Truss Truss Type PB05 GABL 1-11-6 12 5 p B C D Loading Criteria (psq Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 10.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 40.00 Mean Height: 28.00 It NCBCLL: 10.00 TCDL: 5.0 psf Load Duration: 1.25 BCDL: 2.0 psi Spacing: 24.0 " MWFRS Parallel Dist: h to 2h C&C Dist a: 4.28 ft Loc. from endwall: not in 9.00 GCpi: 0.18 Wind Duration: 1.60 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #3 Plating Notes All plates are 2X4(At) except as noted. (++) - This plate works for both Joints covered. City Ply 2 1 1 15'4" 1111.5X4(++) E K J=3X4 17'0"13 19713 Code / Misc Criteria Defl/CSI Criteria Code: FBC 2017 RES PP Deflection in loc Udell LN TPI Std: 2014 VERT(LL): -0,009 C 999 36 Rep Factors Used: Yes VERT(CL): 0.012 C 999 24� FT/RT:10(Ov10(10) HORZ(LL):-0.004 C - - Plate Type(s): HORZ(TL): 0.005 C - - WAVE Creep Factor. 2.0 Max TC CSI: 0.316 Max BC CSI: 0.115 Max Web CSI: 0.114 WgI. 58.8 Ibs VIEW Ver: 19.01.00A.0618.15 Purllns In lieu of structural panels or rigid ceiling use puriins to brace all flat TC @ 24" oc, all BC @ 60" oc. Wind Wind loads based on MWFRS with additional G&C member design. 07/11/2020 2976 1'11"6 —� ♦ Maximum Reactions (Ibs), or "=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL A - /-65 I• 155 /48 120 B' 77 A 1- /49 [72 1- H - /-65 /- /55 149 /- C /-245 K /-375 1 /-375 F 1-244 Wind reactions based on MWFRS A Big Width = 8.5 Min Req = 1.5 B Big Width = 204 Min Req = - H Big Width = 8.5 Min Req = 1.5 Beatings A, B, & H are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 43 -23 E-F 208 -189 B - C 254 -234 F - G 254 -234 C-D 208 -189 G-H 43 -21 D - E 208 -189 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-K 189 -167 J - 1 189 -167 K-J 189 -167 I-G 189 -167 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. D-K 383 -337 E-I 383 -337 R T- W. Al1notsssetox1n Ne TDDsndtsprsvfxesend TP ldefinesNeresponslblllllesandd.Uwdthe Tuns rvdved. The apedalty Engineer is NOT the 3(16/2020 HIP/ KING JACK (TYPICAL) STDL 01.0 '9,AA-f RDOF = TRL155E5 AFLORIOACOftPORATION A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL. 34946 (772)409-1010 ATTACH END JACKS USING (4) 0.131" 0 TOE NAILS AT TOP CHORD & (3) 0.131"0 TOE NAILS AT BOTTOM CHORD. ATTACH KING JACK USING (3) 0.131" 0 TOE NAILS AT TOP CHORD & 24" STRAP USING (6) 1 Od X 11'2' AT EACH END OF BOTTOM CHORD. ATTACH CORNER JACKS USING (2) 0.131" 0 TOE NAILS AT TOP & BOTTOM CHORDS (TYP). CORNERSET GENERAL SPECIFICATIONS: MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60' MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT. FEBRUARY 17, 2017 I ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORO 1' - 3' MAX. OIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE SLOG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES e 24' O.C. 2XG DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \ BRACE AND THE TWO TRUSSES ON \ EITHER SIDE AS NOTED. TOENAIL \ \ BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. END WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-9B, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' O.C. - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131'X3') NAILS SPACED G' O.C. (2X4 STUDS MINIMUM). MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL 15 TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE TRUSS / URAL .IvEll AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. 1 /23/19 PIGGY -BACK TRUSS STDTL04.1 PIGGY -BACK DETAIL 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. "REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE TRUSS SPECIFICATIONS." PIGGY -BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) 2'-0" MAX OPTION NO. T - TEE-LOK 3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X S" TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION NO.2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO.3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION #1: TEE-LOK MULTI -USE CONNECTION PLATE. OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. '• IMPORTANT NOTE •. THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. JULY 17, 2017 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 3494 772-409-1010 VALLEY TRUSS (TYPICAL) SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS W O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO SIMPSON SDS25412 (1/4' X 4.5') OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. DETAIL A GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X 0.131'=10d 2. WOOD SCREW = 4.5'SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24' O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A'. S. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS-01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. BASE TRUSSES E END, COMMON 8S, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6112 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24' O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. FEBRUARY 5, 2018 TRUSSED VALLEY SET DETAIL STDTL06 �! GENERAL SPECIFICATIONS: 1. NAIL SIZE=WX 0.131'=10d 2. WOOD SCREW = 3' SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE PER DETAIL .A. CI 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. S. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. A-1 ROOF TRUSSES 6. NAILING DONE PER NOS -01. 4451 ST. LUCIE BLVD. GABLE END, COMMON 7. VALLEY STUD SPACING NOT TO EXCEED 48'O.C. FORT PIERCE, FL 34946 TRUSS, OR GIRDER 772409-1010 TRUSS SECURI WI( VALLEYTRUSS BASE TRUSSES (TYPICAL) I�11 DETAIL A (NO SHEATHING) N.T.S. GABLE END, COMMON TRUSS, OR GIRDER VALLEYTRUSS TRUSS P �2 (TYPICAL) SEE DETAIL'A' BELOW (TYP.) WIND DESIGN PER ASCE 7-98, ASCE 7-02. ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSUREC WIND DURATION OF LOAD INCREASE: 1.60 ATTACH 2X4 CONTINUOUS #2 MAX TOP CHORD TOTAL LOAD = 50 PSF SYP TO THE ROOF W/TWO MAX SPACING= 24'O.C.(BASE AND VALLEY) SIMPSON SDS25300 (1/4' X 3-) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. JULY 17, 2017 1 IIVJJGU V 11LLC I JC I LJC 1 P11L (HIGH WIND VELOCITY) STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772-0O9-1010 ATTA( WIND DESIGN PER ASCE 7-98, ASCE 7� WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24' O.C. (BASE AND VP SUPPORTING TRUSSES DIRECTLY UNLcn v. IL... .ow i cc DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2'- 10' ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. NON -BEVELED BOTTOM CHORD FOR BEVELED BOTTOM CHORD, CLIP MAYBE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A MAXIMUM 6112 PITCH BC CLIP MUST BE APPLII THIS FACE WHEN I EXCEEDS 6112 (MAN 12112 P �EBIRUARY 17, 2017 STANDARD GABLE END DETAIL STDTL08 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-4019-1010 TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/lOd NAILS, 6' O.C. VERI STUD SECTION B-B TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL 2X6 SP OR SPF STUD #2. DIAGONAL BRACE (4) - 16tivi NAILS 16d NAILS SPACED 6' O.C. (2) lOd NAILS INTO 2X6 2X6 SP OR SPF #2 2X4 SP OR SPF #2 TYPICAL HORIZONTAL BRACE NAILED TO 2X4 VERTICALS SECTION A -A W/(4) - 10d NAILS OIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. TOENAIL BLOCKING TO TRUSSES * WITH (2) - 10d NAILS AT EACH END. N� ATTACH DIAGONAL BRACE TO \ BLOCKING WITH (5) - 10d NAILS (4) 8d NAILS MINIMUM, ** R 3X4= PLYWOOD SHEATHING TO 2X4 STD SPF BLOCK * DIAGONAL BRACING ** L - BRACING REFER V REFER TO SECTION A -A TO SECTION B-B 24' MAX. / GRADEOF #2 MATERIAL IN THE TOP AND BOTTOM 2. HAND CONNECTIONMINIMUM BETWEEN BOTTOM CHORD OF GABLE ENO TRUSS WALL TO 12' MAX. BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG, ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. S. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM / AT 4'-0' O.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIOSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. OIAG. BRACE S. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0.131'X3.5' COMMON WIRE NAILS RESPECTIVELY. 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2%4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4SP#31STUD 12'O.C. 3-8-10 5-6-11 61r11 11-1-13 2X4SP#31STUD 1VO.C. 3.3-10 4-9-12 6-6-11 9.10-15 2X4SP#31STUD 24'O.C. 2-8-6 3.11-3 5A42 8-1-2 2X4SP42 12'0.C. 3.10-15 5&11 6-6-11 11-8-14 2X4 SP#2 WO.C. 3-6-11 4-9-12 W1 10.8.0 2X4 SP #2 24'O.C. 3-1-4 3-11-3 6.2-9 9.3-13 DIAGONAL BRACES OVER 6' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH 10d NAILS 6' O.C., WITH 3- MINIMUM ENO DISTANCE. BRACE MUST COVER 90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. ROOF SHEATHING (2) - 10d NAILS TRUSSES @ 24' O.C. 2X6 DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d NAILS. HORIZONTAL BRACE (SEE SECTION A -A) ENO WALL =30 FEET STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS. -"1 \ w V , . . , .. STDTL09. FEBRUARY17,2017 WITH 2X BRACE ONLY ; NOTES: T-BRACING / I -BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T-BRACE / I -BRACE MUST COVER 90% OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T-BRACE / I -BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-i ROOF TRUSSES 4461 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2114 OR 2116 OR 2X8 10d 6" O.C. NOTE: NAIL ALONG ENTIRE LENGTH OF T-BRACE / I -BRACE (ON TWO-PLY TRUSSES NAIL TO BOTH PLIES) NAILS BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 I -BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T-BRACE 2X4 I -BRACE 2X6 2X6 T-BRACE 2X6 I -BRACE 2X8 2X8 T-BRACE 2X8 1-BRACE T-BRACE / I -BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. I -BRACE NAILS WEB T-BRACE SECTION DETAILS ,FEB RUARY17,2O17 I LATERAL BRACING RECOMMENDATIONS I STDTLIO TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2XS "STRONGBACK" IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. C' NOTE 1: 2XG STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 RF TRUSS ES DF THE METHODS ILLUSTRATED BELOW. 4451 ST.00LUCIE BLVO. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772d09-1016 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO ENO, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENOS. INSERT W000 SCREW THROUGH OUTSIDE FACE OF CHORD INTO ATTACH`\ EDGE OF STRONGSACK (DO NOT TICAL ' WITH USE A C OTO AL FRAMING ATTACH TOPR TO ATTACH CHOROA N IBLS (0103137XR 31)dL \N ILS 4(0131 3KR 3'). USE DRYWALLAILS (0ACH TO VERTICAL \ WEB WITH (3) - 10d BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0.131' X 3') IN EACH CHORD ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA1 USE METAL FRAMING ATTACH TO VERTICAL L ATTACH TO VERTICAL L INSERT SCREW THROUGH ANCHOR TO ATTACH WEB WITH (3) - Uld SCAB WITH (3) - 10d OUTSIDE FACE OF CHORD INTO TO BOTTOM CHORD NAILS (O.131' X 3') NAILS (0.131' X 3') EDGE OF STRONGBACK (00 NOT USE DRYWALL TYPE SCREWS) TRUSS 2XG 4' - STRONGBACK (TYPICAL 0' WALL SPLICE) � (BY OTHERS) THE STRONGBACKS SHALL BE SECURED AT THEIR ENOS TO AN ADEQUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTL1114, ,r w. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES - TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) OIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 z .135 93.5 85.6 74.2 72.6 63.4 0 J .162 108.8 99.6 86.4 84.5 73.8 �i .128 74.2 67.9 58.9 57.6 50.3 0 0 .131 75.9 69.5 60.3 59.0 51.1 in .148 81.4 74.5 64.6 63.2 52.5 N M VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0.162' OIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30` TO 60° 45.00° ANGLE MAY VARY FROM 30° TO 60' THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELDW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00° SIDE VIEW (2X6) 4 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30° TO GO' 45.000 tEB�UARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL U946 772-409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. NOTES TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP OF HF SPF SPF-S LO .131 59 46 32 30 20 Z O J .135 60 48 33 30 20 U7 !7 .162 72 58 39 37 25 J _ C-D .128 54 42 28 27 19 J­ LD z Z O .131 55 43 29 28 19 LU .148 62 48 34 31 21 J N _J Q 17 Z .120 51 39 27 26 17 O Z .128 49 38 26 25 17 O .131 51 39 27 26 17 J O .148 57 44 31 28 20 (7 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED I/3 THE LENGTH OF THE NAIL FROM THE MEMBER ENO AS SHOWN. 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0.162' OIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WINO OOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 1.33 (OOL FOR WINO) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WINO ODL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 IDOL FOR WINO) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WINO IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LEIS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. USE (3) TOE -NAILS ON 2X4 BEARING WALL ... USE (4) TOE -NAILS ON 2XG BEARING WALL NEAR SIDE FAR S )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY IL NAIL NAIL SIDE VIEW END VIEW FEBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT STDTLI3 2x2 NAILER ATTACHMENT �= GENERAL SPECIFICATIONS A•1 ROOF TRUSSES 4RT IE CE,FLUCIE 3494 MAX LOAD: 55 psf Roof Load, 170 mph, ASCE FORT PIERCE, FL 34946 n2-409-1010 7-10, 29'-0" Mean Height, Exp. B, C or D. 0x4 4p§l 11, 2016 TYPICAL ALTERNATE BRACING DETAIL STDTLI4 FO EXTERIOR FLAT GIRDER TRUSS A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT 12 VARIES (4) 12d MAX 30" (21-6") 2x6 #2 SP 2411 O.C. SIMPSON (Both Faces) H5 FEBRUARY 17, ZO17 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES r A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409.1010 .Ulfrx; TOTAL NUMBER OF NAILS EACH SIDE OF BREAK r X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2T47 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24" 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30" 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36" 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42" 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48" 3657 5485 3346 5019 2829 4243 2898 4347 • DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2XS) SPACED 4' O.C. AS SHOWN (.131' OIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN, 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X t C L •10d NAILS NEAR SIDE + 10d NAILS FAR SIDE - BREAK X � X' MIN 6' MIN a TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF So FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). 00 NOT USE REPAIR FOR JOINT SPLICES 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN, THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WODO, 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. B. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. 17,2017 1 SCAB APPLIED OVERHANGS I STDTL16 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772-409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 1.15 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL END GEARING CONDITION NOTES 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, (IF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED 6' D.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL. BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. Ilrll1][4/_Prl THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES