Loading...
HomeMy WebLinkAboutEnergy CodeJob# PedoFmedfor. LONERYAO7MN M GRUIERS FU. FTREFKE, FL ,:�Fcoo 6-N) mini-spli+ NEW OFFICE NEW FAMILY ROOM T 151COO (W e�' Cam. [mini QUICK CALLS, INC. 317ST. LUCIE LME FORTPIERCE, FL34 M Phone:M-466-6799 QUICKCALCS (taIA OL.COM Scale:1.:61 F494-& LilUivasd2119 99 07ML W 2EkU31 izw _ytdtHJAM 111FWAmTIWnp FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LOWERYADDITION Builder Name: Street: 4901 GROVERS RD. Permit Office: ST.LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Owner: ZANE 8 CHRISTY LOWERY Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (928.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 928.00 ft' b. N/A R= ft' 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms (Bedrms In Addition) 0(0) d. NIA R= ft' 10. Ceiling Types (724.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 724.00 ft= 6. Conditioned Floor area above grade (ft') 724 b. N/A R= ft' c. N/A R= ft' Conditioned floor area below grade (ft') 0 11. Ducts R ft' 7. Windows(96.0 sqft.) Description Area a. U-Factor: SgI, U=0.30 56.00 ft' SHGC: SHGC=0.21 b. U-Factor: SgI, U=0.65 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 18.0 SEER:15.50 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 18.0 HSPF:9.25 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Y Area Weighted Average SHGC: 0.227 14. Hot water systems -None required a. Cap: NIA B. Floor Types (724.0 sqft.) Insulation Area EF: 1.21635E008 a. Slab -On -Grade Edge Insulation R=0.0 724.00 ft' b. Conservation features b. N/A R= ft' c. NIA R= ft' 15. Credits None Glass/Floor Area: 0.133 Total Proposed Modified Loads: 19.89 PASS Total Baseline Loads: 21.68 1 hereby certify that the plans and specifications covered by Review of the plans and gtAE ST4l. this calculation are in compliance with the Florida Energy specifications covered by this g FOB Code. calculation indicates compliance with the Florida Energy Code. ti un,r"• ':r=;;;'°°„ O PREPA ED BY: g*RQJ2 Before construction is completed DATE: '- this building will be inspected for compliance with Section 653.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD wr C¢J OWNER/AGENT, BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with EVPEW ISno Fgreat r than 5.00 ACH50 (R402.4.1.2). CODE COMPLIANCE �LE CV PYST. LUCIIECOUNTY ri EnergyGaug@6/16/2020 11:10 AM USA 2KG 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT • Title: LOWERYADDITION Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 724 Lot # Owner Name: ZANE & CHRISTY LOWERY Total Stories: 1 BlocklSubdivision: . # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4901 GROVERS RD. Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: Addition ' Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 724 5792 SPACES Number Name Area Volume Ktchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 NEW FAMILY ROO 600 4800 No 0 1 Yes Yes Yes 2 NEW OFFICE 99 792 No 0 1 Yes Yes Yes 3 TLT. 25 200 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation NEW FAMILY RO 84 ft 0 600 ft' ---- 0 1 - 0 2SIab-On-Grade Edge Insulation NEW OFFICE 20 ft 0 99 ft' ---- 0 1 0 3 Slab -On -Grade Edge Insulation TLT. 12 it 0 25 ft' ---- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 763 ft' 0 ft' Unfinishe N 0.5 No 0.7 No 20 18.4 ATTIC / RBS IRCC V # Type Ventilation Vent Ratio (1 in) Area 1 Full attic Unvented 0 724 ft' N N 6116/202011:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) NEW FAMILY RO 0 Blown 600 ft' 0.1 Wood 2 Under Attic (Unvented) NEW OFFICE 0 Blown 99 ft' 0.1 Wood 3 Under Attic (Unvented) TLT. 0 Blown 25 ft' 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space _ 1 N Exterior Frame -Wood NEW FAMILY 13 24 0 8 0 192.0 ft' 0 0.25 0.6 0 _ 2 E Exterior Frame -Wood NEW FAMILY 13 25 0 8 0 200.0 ft' 0 0.25 0.6 0 _ 3 S Exterior Frame -Wood NEW FAMILY 13 24 0 S 0 192.0 ft' 0 0.25 0.6 0 _ 4 W Exterior Frame - Wood NEW FAMILY 13 11 0 8 0 88.0 ft' 0 0.25 0.6 0 _ 5 N Exterior Frame- Wood NEW OFFICE 13 9 0 8 0 72.0 ft' 0 0.25 0.6 0 6 W Exterior Frame -Wood NEW OFFICE 13 11 0 8 0 88.0 ft' 0 0.25 0.6 0 7 S Exterior Frame -Wood TLT. 13 9 0 8 0 72.0 ft' 0 0.25 0.6 0 8 W Exterior Frame - Wood TLT. 13 3 0 8 0 24.0 ft' 0 0.25 0.6 0 WINDOWS Orientation shown is the entered Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Single Yes 0.3 0.21 Y 20.0 ft' 2 ft 0 in 1 ft 4 in None None 2 E 2 Vinyl Low-E Single Yes 0.3 0.21 Y 12.0 ft' 2 ft 0In 1 ft 41n None None 3 E 2 Vinyl Low-E Single Yes 0.3 0.21 Y 24.0 ft' 2 ft 0 in 1 ft4 in None None 4 W 4 Vinyl Low-E Single Yes 0.65 0.25 Y 40.0 ft' 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 482.7 26.5 49.83 .0881 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heal Pump/Supplemen Split Single HSPF:9.25 18 kBtu/hr 1 Ductless COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Supplemental for a Split Single SEER: 15.5 18 kBtu/hr cfm 0.7 1 Ductless 6/16/2020 11:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF ft' TEMPERATURES Programable[r%Thermostat: N Ceiling Fans:Cooling Jan VentiDec H Feb Feb Mar H Mar Apr Apr May n Jun [ ] [X] Jul f ri Aug �x� Sep NovjrX']NovjX'] Nov Dec ng [ ] Jan Jun [ 1 Jul I Aug Sep Oct [X] [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defauft(B lbs/sq.ft. 0 ft' 0 ft 0.3 NEW FAMILY ROO Defauft(8lbs/sq.ft. ft' ft 0.3 NEW OFFICE Default 81bs/s .ft. ft' ft 0.3 TLT. 6/16/2020 11:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC Sth Edition (2017) Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LOWERYADDITION Builder Name: Street: 4901 GROVERS RD. Permit Office: ST.LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: ZANE & CHRISTY LOWERY Jurisdiction: w x Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be Installed In the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shall be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of RJ per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (Including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided Instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed In the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring a plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipingand wiring. Showedtub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electricallphone box on The air bamer shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of IUC-4U0. 61161202011:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location & insulation level a) Supply ducts R 2. Single-family or multiple -family 2. Single-family b) Return ducts R c) AHU location 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 0 13. Cooling system: Capacity 18.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 724 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.446 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.227 c) Area 7c. 96.0 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) So. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 13.0 10A2. 10B1. 10B2. 118. 0.0 11 b. 11 c. 11d. No 14. Heating system: Capacity 18.0 a) Split system heat pump HSPF 9.3 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans b) Cross ventilation No c) Whole house fan No d) Multizone cooling credit e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Address of New Home: 4901 GROVERS RD. City/FL Zip: FT. PIERCE. FL 6/1612020 11:10:53 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1