HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door AssembliesI
fBusiness & Professional
_
r
BcisHome I Login I User Registration I Hot Topics
Submitsurchame I statsaFacts
I Publications I ContectUs I BUS See Map I Nnks I Search
• dbpr
Product Approval
� OSER: Public Dzer
SHOPSTAMPREVIEW wt1/mn Emerald
Review is for general compliance with the Construction Documents.
t=U=
Responsibility for correctness of dimensions, details, quantities and safety
product Approval Menu> Application Detail
during fabrication lies solely with the contractor.
CO No Exceptions Taken Reviewed Br. Dawn Boggio-Korbelak
FRIM FL It
FL20461-113
O Rejected:
Application Type
Revision
Code Version
2017
11/22/19Application
Status Status
Approved
QI!•'1
Comments
Archived
❑
Product Manufacturer Therma-Tiu Corporation
Address/Phone/Email 118 Industrial Drive
Edgerton, OH 43517
(419) 298-1740
rickw@mbldgconsultants.com
Authorized Signature Vivian Wright
rlckw@mbidgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed
Lyndon F. Schmidt, P.E.
the Evaluation Report
Florida License
PE-43409
Quality Assurance Entity
National Accreditatlon and Management Institute
Quality Assurance Contract Expiration Date
12/31/2021
Validated By
Ryan 1. King, P.E.
2 Validation Checklist - Hardcopy Received
Certificate of Independence FL20461 RT COI fd1 Certificate
of Indepandence.l
Referenced Standard and Year (of Standard) Standard
Year
101/I.S.2
1997
ASTM E330
2002
ASTM E331
2000
TAS 202
1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date
Submitted
12/13/2017
Date
Validated
12/13/2017
Date
Pending FBC Approval
12/21/2017
Date
Approved
02/13/2018
Date
Revised
10/09/2018
Summary of Products
Go to Page = 0
0 O Pagel/20
FL #
Model, Number or Name
Description
20461.1
a. Therma-Tru Fiber -Classic and
Nominal 6e "Nan -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single. Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 II (e) Inst 20461.1.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.1 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.I.Ddf
additional use limitations, installation Instructions and product
Created by Independent Third Party: Yes
Particulars. (Far Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of Installation.
20461.2
b. Thera-Tru Fiber -Classic and
Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sldelite(s) (Inswing/Outswing; XO, OX or
OXO configurations)
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL20461 R3 11 (el Inst 20461.2.odF
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Parry: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.2 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.2.odf
additional use limitations, Installation Instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "I" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.3
c. Therma-Tru Fiber -Classic and
Nominal 6'8 "Non -Impact" Opaque Fiberglass Composite Edge
Smooth -Star
Double Door with or without Sldelltes (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 11 (e) Inst 20461.3.ndf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.3 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.3.Ddf
additional use limitations, Installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of'O" part numbers for
these doors, which have been stained or painted within six
months of installation.)
20461.4
d. Therma-Tru Fiber -Classic and
Smooth -Star
Nominal VC "Non -Impact" Opaque Composite Edge Fiberglass
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 II (e1 Inst 20461.4.udf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.4 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.4.pd
additional use limitations, Installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of'7" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.5
e. Therma-Tm Fiber -Classic and
Nominal TO "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sldelite(s) (Inswing/Outswing; XO, OX or
ONO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 11 (e) Inst 20461.5..Ddf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.5 for Design Pressure Ratings, any
additional use limitations, installation Instructions and product
FL20461 R3 AE M Eval 20461.5.odf
Created by Independent Third Party: Yes
particulars. (Far Fiber -Classic and Smooth -Star doors, this
product approval requires the use of'7" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.6
f. Therma-Tm Fiber -Classic and
Nominal WO "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 11 (e) Inst 20461.6.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.6 for Design Pressure Ratings, any
FL20461 R3 AE M Eval 20461.6.odf
additional use limitations, Installation Instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "3' part numbers for
these doom, which have been stained or painted within six
months of installation.)
20461.7
g. Thera-Tru Fiber -Classic and
Nominal B'0 "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sldelite(s) (Inswing/Outswing; XO, OX or
ONO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 II (e) Inst 20461.7.ndf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.7 for Design Pressure Ratings, any
additional use limitations, Installation Instructions and product
FL20461 R3 AE (d) Eval 20461.7.odf
Created by Independent Third Party: Yes
particulars. (Far Fiber -Classic and Smooth -Star doors, this
pmduct approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.8
h. Therma-Tm Fiber -Classic and
Nominal 8'0 "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelites (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL20461 R3 II (e) inst 20461.8.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.8 for Design Pressure Ratings, any
additional use limitations, Installation Instructions and product
FL20461 R3 AE (d) Eval 20461.8.odf
Created by Independent Third Party: Yes
particulars. (For Fiber{lasslc and Smooth -Star doors, this
product approval requires the use of 'I" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.9
I. Therma-Tru Fiber -Classic and
Nominal VS "Non -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 11 (e) Inst 20461.9.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.9 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.9.odf
additional use limitations, Installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "I" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.10
1. Therma-Tm Fiber -Classic and
Nominal 6'8 "Nan -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or
ONO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 it (e) Inst 20461.10.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.10 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.10.odf
additional use limitations, Installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of installation.)
20461.11
k. Therma-Tru Fiber -Classic and
Nominal 6'8 "Non -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelltes (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL20461 R3 If (e) Inst 20461,11.ndf
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.11 for Design Pressure Ratings, any
additional use limitations, Installation instructions and product
FL20461 R3 AE (d) Eval 20461.11.ndf
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "I" part numbers for
these doors, which have been stained or painted within six
months of installation.)
20461.12
I. Therma-Tru Flber-Classic and
Nominal 7'0 "Non -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door(Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 II (el Inst 20461.12.edf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.12 for Design Pressure Ratings, any
FL20461 R3 AE (dl Eval 20461.12.odf
additional use limitations, Installation Instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.13
on. Therma-Tru Fiber -Classic and
Nominal 7'0 "Non -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door with Sldellte(s) (Inswing/Outswing; XO, OX or
OXO configurations)
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL20461 R3 II (e) Inst 20461.13.odF
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Parry: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.13 for Design Pressure Ratings, any
FL20461 R3 AE (dJ Eval 20461.13.od(
additional use limitations, installation Instructions and product
Created by Independent Third Party: Yes
particulars. (For Flber-Classic and Smooth -Star doors, this
product approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.14
n. Therma-Tru Fiber -Classic and
Nominal 8'0 "Non -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door (Inswing/Outswing; X configuration)
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL20461 R3 11 (e) Inst 20461.14.Rdf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.14 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.14.odf
additional use limitations, Installation Instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.15
0. Therma-Tru Fiber -Classic and
Nominal TO "Non -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Single Door with Sldellte(s) (Inswing/Outswing; XO, OX or
OXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
EL20461 R3 II (e) Inst 20461.15.odF
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.15 for Design Pressure Ratings, any
FL20461 R3 AE (dl Eval 20461.15.odf
additional use limitations, Installation Instructions and product
Created by Independent Third Party: Yes
particulars. (Far Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "J" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.16
p. Therni Fiber -Classic and
Nominal 8'0 "Non -Impact" Glazed Composite Edge Fiberglass
Smooth -Star
Double Door with or without Sidelltes (Inswing/Outswing; XX
or OXXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 II (a) Inst 20461.I6.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.16 for Design Pressure Ratings, any
FL20461 R3 AE (d) Eval 20461.16.odf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product, approval requires the use of'7" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.17
q. Therma-Tru Fiber -Classic and
Nominal 6'e "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Transom (Inswing/Outswing; O/X
configuration)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 It (e) Inst 2O461.17.ndf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See INST 20461.17 for Design Pressure Ratings, any
additional use limitations, Installation Instructions and product
FL20461 R3 AE (d) Eval 20461.17.ndf
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "I" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.18
r. Therma-Tru Fiber -Classic and
Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sideilte(s) and Transom (Inswing/Outswing;
O/XO, O/OX or O/OXO configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20461 R3 II re) Inst 20461.18.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: INST 20461.18 for Design Pressure Ratings, any
FL20461 R3. AE (d) Eval 2O461.18.nd/
additional use limitations, Installation Instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "I" part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.19
s. Therma-Tru Fiber -Classic and
Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sldelite(s) (Inswing/Outswing; XO, OX or
OXO Continuous Head and SIII conFlguratlons)
Limps of Use
Installation Instructions
Approved for use In HVHZ: No
FL20461 R3 II (e) Inst 20461.19.odf
Approved for use outside HVHZ: Yes
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: INST 20461.19 for Design Pressure Ratings, any
FL2O461 R3 AE (d) Eval 20461.19.ed!
additional use limitations, Installation Instructions and product
Created by Independent Third Parry: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of "P' part numbers for
these doors, which have been stained or painted within six
months of Installation.)
20461.20
t. Therma-Tru Fiber -Classic and
Nominal 8'0 "Non -Impact" Opaque Composite Edge Fiberglass
Smooth -Star
Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or
OXO Continuous Head and SIII configurations)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL20461 R3 II (e) Inst 20461.2O.od(
Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: INST 20461.20 for Design Pressure Ratings, any
FL2O461 R3 AE (dl Eval 20461.70.odf
additional use limitations, installation instructions and product
Created by Independent Third Party: Yes
particulars. (For Fiber -Classic and Smooth -Star doors, this
product approval requires the use of'P' part numbers for
these doors, which have been stained or painted within six
months of Installation.)
Go to Page 0 ® 0 Page 1/ 2 0 0
Bavk PER
ooitaaa Us :: 2601 Blair Stone Road Tallahassee R 32399 Phone : 050487.1824
The Rate ar Bodda Ia an AA/EW employer. SuvvdaM1[ 000yda13 state of Fladtla.:: Ptiva,v Statement :: Aaesslbillty statement :: Refund Statement
can
MER®®®
md..ay Senmaay pnPma
R W R W Building Consultants, Inc.
B Consulting and Engineering Services for the Building Industry
C P.O. Box 230 Valrico, FL 33595 Phonegl3.659.9197
Florida Board off'rofessional Engineers Certificate ofAuthoriration No. 9813
Product
Category
Category
Sub Categ- -
Manufacturer
Product Name
- -
Swinging
Therma-Tru Corporation
Fiber-Classle and Smooth-Star
Exterior
Exterior Door
118 Industrial Or
Composite Edge Opaque Fiberglass Single Door
Doors
Assemblies
Edgerton, OH 43517
Inswing r Outswing
Phone 419.2984740
"Non -Impact"
Scope., Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for
Therma-Tru Corporations, based on Rule Chapter No. 61G20-3, Method 1D of the State of Florida Product Approval, Dept
of Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have norwill acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named
herein.
Urnitatfons:
1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements
excluding the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown an details. Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. For 2z stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction.
4. Site conditions that deviate from the details of drawing FL-20461.1 require further engineering analysis by a licensed engineer or
registered architect
S. Fiber -Classic & Smooth -Star Door panels require the use of "J" part numbers and must be stained or painted within six months of
Installation
6. See drawing FL-20461.1 for size and design pressure limitations.
Supporting Documents:
1. Test Report No. Test Standard Testing Laboratory
TEL 01460145 ASTM E330(02), ASTM E331(00) Testing Evaluation Lab.,lnc.
TEL 01461573 ASTM E330.02 & ASTM E331-00 Testing Evaluation Lab.,lnc.
2. Drawing No. Prepared by
No. FL-20461.1 RW Building Consultants, Inc. (CA #9813)
3. Calculations Prepared by
Anchoring RW Building Consultants, Inc. (CA#9813)
4. Quality Assurance
Certificate of Participation issued by National Accreditation &
Management Institute, certifying that Thera-Tru Corporations is
manufacturing products within a quality assurance program that
complies with ISOAEC 17020 and Guide 53.
SHOP STAMP REVIEW wal
Review Is for general compliance with the Construction Documents.
Responsibillty for correctness of dimensions, details, quantldes and safety
during fabrication lies solely with the contractor.
Pill No Exceptions Taken Reviewed By. Dawn Boggio-Korbelak
❑ Refected:
11 /22119 Da,.n $.
Sheet 1 of 1
Slqned by
V.K. Wright
V.K. Wright
Signed & Sealed b
Lyndon F. Schmidt, P.E.
Signed & Sealed by
Lyndon F. Schmidt, P.E.
Lyndon F. scnmiot, P.t.
FL PE No. 43409
121712017