Loading...
HomeMy WebLinkAboutConstruction PlansPHUTOVOLTAk, RuOF MOUNT SYSTEM 34 MODULES -ROOF MOUNTED-11.560 kW DC, 8.160 kW AC, 6801 COQUINA AVE, PIERCE, FL 34951 PHOTOVOLTAIC SYSTEM SPECIFICATIONS: SYSTEM SIZE: 11.560 kW DC 8.160 kW AC MODULE TYPE & AMOUNT: (34) HANWHA Q.PEAK DUO BLK-G6+340W MODULE DIMENSIONS: (LIW/H) 68.5-140.6'/1.26- INVERTER: (34) ENPHASE ENERGY 1Q7-60-2-US [240V] INTERCONNECTION METHOD: LOAD BREAKER GOVERNING CODES ALL WORK SHALL CONFORM TO THE FOLLOWING CODES a. 2014 NATIONAL ELECTRICAL CODE b. 2017 FL BUILDING CODE - 6TH EDITION C. 2017 FL RESIDENTIAL CODE - 6TH EDITION d. 2017 FL PLUMBING CODE-6TH EDITION e. ANY OTHER LOCAL AMENDMENTS PROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT ROOF #' (05) HANWHA Q.PEAK DUO BLK-G6+ 340VN SLOPE:17' AZIM.: 360' EXISTING INTERIOR MAIN SERVICE PANEL TIED TO EXTERIOR UTILITY METER# -- CONFLICT WITH OVERHEAD OBSTRUCTIONS ROOF#3 SUCH AS TREE LIMBS, WIRES OR SIGNS. (04) HANWHA Q.PEAK DUO BLK-G6+ 34OW GENERAL NOTES: SLOPE:17° 1. APPLICABLE CODE: 2017 FLORIDA BUILDING CODE AZIM.:270° (6TH EDITION) & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. LAG SCREW DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF RAFTERS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 23° (5112 TO A MAXIMUM 7112 PITCH) ROOF IN SCHEDULE. CONTRACTOR TO FIELD VERIFY THAT MEAN ROOF HEIGHT DOES NOT EXCEED 15'-0°. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT DRILL AND FILL ALL HOLES. 5. ALL DISSIMILAR MATERIALS SHALL BE SEPARATED WITH NEOPRENE WASHERS, PADS, ETC OR SIMILAR. 6. ALL ALUMINIUM COMPONENTS SHALL BE ANODIZED ALUMINIUM 6105-T5 UNLESS OTHERWISE NOTED. 7. ALL LAG SCREW SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 9. CONTRACTOR SHALL ENSURE ALL R00� OPERTYLINE PENETRATIONS TO BE INSTALLED AND SEALED PE 2017 FLORIDA BUILDING CODE (6TH EDITION) OR LOCAL GOVERNING CODE, 1 PLOT PLAN A oo SCALE: 1/16'=17 T 6801 COQUINA AVE FRONT OF HOUSE 75-On .S ILE COPY ROOF ACCESS POINT I'41N. SETE FRONT 81DE8 .��� CNq DIDtfII SHEET INDEX: PV0.0: COVERSHEET PV 1.0: SITE PLAN E S 1.1: MOUNT DETAILS E 1.1: 3-LINE DIAGRAM E 1.2: ELECTRICAL NOTES E 1.3: WARNING LABELS DS-01+ DATA SHEET CLIMATIC SOLAR ,em.°ema,°rer.wwn. 650 2nd LANE VERO BEACH, FL 32962, USA PHONE: 772-567-3104 FAX: V72) 567-4553 wwwAimaticsolamom 11 oEsauPnDN I DATE I REV 11 W W Q m Z w CyLLZ 0 LaO Z U_ w _ W w co a SATELLITE VIEW 2 A-00 SCALE: NTS SHEET NAME Vero Beach IOOF#1 )4) HANWHA Q.PEAK DUO BLK-G6+ COVER , ,,._ .,!� I,I � � \+, , 40w SHEET ;LOPE: 17o I -Oslo - } 4- i ^ - 'R.0daRldge`- •1. y+ ^?' S { r SHEET SIZE 68a7uina Avenue - ANSI B W6 F L` n n DQF #4 r o' - 'snkewood I11 ,' v 11 X 17 2) HANWHA Q.PEAK DUO BLK-G6+ m i 1?a; , 'r �i, ' SHEET NUMBER 10W n LOPE: 18i.LUCIE COUNTY I " �^ ;,;7 �'7 „-00 ZIM.: 180° PLAN REVIEW - _ r "^ `' Tressuro Ccaatr (: riIntemaRonal ;SIGNATURE WITH SEAL Al endt( ts1`i�t BLDG: Business Park,j SttLu DATE ELE �' 3 _ VICINITY MAP DATE: !i^' PLUMB: A-0D SCALE: NTS Sf DATE: DATE:, ��; � _.. - - t: ';', ? .. .. ' ,,; I , . 'r c� ` 4� � ��.� .-` �\' � q �-�./_ f � � / +' 1 _\` �� � �� J � l _-• \ �� E 6801 COQUINA AVE FRONT OF HOUSE • 01 �?�C,a 1 SITE PLAN MODULE RATING IS -55.6 PSF SO MODULES aa1 SCALE: 3132' =17 MAY BE INSTALLED IN ALL 3 ROOF ZONES ROOF SECTIONS ROOF MODULE - 04 #01 I SLOPE - 176 IVAZIMUTH 900 MATERIAL COMPSHINGLE RAFTER SIZE - 2'X4' @ 24' O.C. FR—OO—Fl MODULE - 05 #02 SLOPE 17° ITAZIMUTH 360° MATERIAL COMPSHINGLE RAFTER SIZE - 2'X4' @ 24" O.C. ROOF MODULE - 04 SLOPE - 170 AZIMUTH 2700 MATERIAL COMPSHINGLE RAFTER SIZE - 2'X4' @ 24' O.C. ROOF MODULE - 22 #04 SLOPE - 170 AZIMUTH - 1800 MATERIAL - COMPSHINGLE RAFTER SIZE - 2'X4' @ 24' O.0 CIRCUIT(S) ® CIRCUIT #1-12 MODULES ®CIRCUIT#2-11 MODULES ® CIRCUIT #3 -11 MODULES PRESSURES DERIVED FROM PAGE 25 COMPONENTS AND CLADDING TABLE 2017 FBC 6TH ED RESIDENTIAL RISK II ENCLOSED STRUCTURE USING 18 SQ FT AFFECTED AREA 160MPH WIND ADJUSTMENT FACTOR FROM EXPOSURE B TO EXPOSURE C MEAN ROOF HEIGHT 12 FT FT OF 1.21 ROOF PITCH 17.0 DEGREES KD=.85 KZT =1.0 TERRAIN IS FLAT GENERAL INSTALLATION PLAN NOTES: 1) ROOF ATTACHMENTS TO SEE RAFTERS SHALL BE INSTALLED AS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WIND ZONE: WIND ZONE 1:4'-0" O.C. WIND ZONE 2: 2'-0" O.C. WIND ZONE 3:2'-O" O.C. SYSTEM LEGEND EXISTING INTERIOR MAIN SERVICE PANEL& POINT OF INTERCONNECTION. TIED TO EXTERIOR UTILITY METER. NEW SOLADECK JUNCTION BOX J NEW DEDICATED PV SYSTEM COMBINER PANEL 34 NEW HANWHA QPEAK DUO BLK-G6+340W MODULES WITH NEW 34 - ENPHASE ENERGY I07-60-2-US 1240A INVERTERS, MOUNTED ON THE BACK OF EACH MODULES. ]O = ROOF OBSTRUCTIONS = ATTACHMENT POINTS _- =RAFTER -- =RACKING SYSTEM = CONDUIT EXTERIOR RUN -- = CONDUIT ATTIC RUN = WIND ZONE 1 = WIND ZONE 2 = WIND ZONE 3 MODULE, ARRAY WEIGHT (LOAD CALC'S) :r of Modules 34 a Weight 43.9 LBS dodule (Array) Weiahl 1 1492.60 1 LBS of Attachment point 71 1 System Weight 1.5 1599.10 21.02 Array Area 656.65 iuted Load 2.35 M WaAITMkWAm+) Roof Area 1008 Percentage or Roof Covered 65.14% YAmIWRa°l )"w DESIGN CRITERIA ND SNOW LOAD (psf) SPEED (mph) SURE CATEGORY HEIGHT (ft.) LENGTH (ft.) WIDTH (ft.) 'ET HEIGHT (ft.) DESIGN CALCULATION 2) THE PERIMETER WIDTH DIMENSION IS CALCULATED AS FOLLOWS: LEAST HORIZINTAL DIMENSION OF BUILDING:15 FT X.1 =1.5 FT ZONE WIDTH 40% OF MEAN ROOF HEIGHT (12 FT) = 4.8 FT WIND ZONE I USE THE SMALLER OF THE TWO, 3 FT WHICH IS GREATER THAN THE MINIMUM OF 3 FT. WIND ZONE I LBS LBS LBS LBS SgFt SgFt Per SgFt SgFt 20 0 160 B 12 63 15 0 1 OF PRESSURE COEFFICIENT X10%(ft.) 1 1.5 4.0' -73.900 CLIMATIC SOLAR rme.."eieme,yywwas 650 2nd LANE VERO BEACH, FL 32962, USA PHONE: 772-567-3104 FAX: (772) 5674553 www.dimatiesolar.com REVISIONS DEWFUPIION DAIS REV PROJECT NAME LU LU W Q rn I z LuZ O � Z � d LLI LL 00 a cc C9 SHEET NAME SITE PLAN SHEET SIZE ANSI B 11" x 17" SHEET NUMBER A; Q1 SIGNATURE WITH SFALI /�y�zo SEE ENE ' 1 \ ATTACHMENT DETAIL (SIDE VIEW)_ gDt / SCALE: NTS 130 IRONRIDGE END / MID CLAMP PV MODULES IRONRIDGE XR-100 RACKING SYSTEM QUICKMOUNT L-FEET QUICKMOUNT FLASHING WASHER SEALING 5116" ID x 3/4"OD EPDM BONDED SS 2"X4" RAFTERS @ 24" OC LAG BOLT, 5/16" LAG BOLT TO BE SUPPLIED BY QUICK MOUNT IN THE FLASHING KIT AND IS 5/16" X 4" WITH 2-1/2" THREADS AND EMBEDDED INTO TRUSS 3-1/2" ao� 150 115 wamm HMm Nadis"n ub"y R snanrcs Wablla F med Dme � Notes: 1. Values are nominal design 3-second gust 1 wind speeds in miles per hour (m/s) at 33 ft (iem) above ground for Exposure [ cat- egory. 2. Linear interpolation between contours I is permitted. 1 3. Islands and coastal areas outside the last contour shall use the last wind speed contour of the coastal area. 4. Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind condi- tions. $, wind speeds correspond to approximately a 7% probability of exceedance in 50 years i (Annual Exceedance Probability = 0.00143, MRI = 700 years). _ s AA��.� 15 130 NW% CLIMATIC SOLAR ren.�m.�,�,W�650 2nd LANE VERO BEACH, FL 32962, USA PHONE: 772567.3104 FAX: (772) 567-4553 140 www.dimaticsolar.com I REVISIONS DESCRIPTON DAIS REV 0LU i �, V LU C3 Q Dade W N Lfi _j U_ W W _ aMlh IL W d U_ O W d 18/0 co ° ° I MOUNT DETAIL Figure 1609A Wind -Borne Debris Region, Category II and III Buildings and Structures except health care facilities 11" x 17" SHEET NUMBER S-01: SI.NATUREMNSEALp WIRE WIRE WIRE WIRE TYPE TEMP WIRE TEMP CONDUIT WIRE TERMINAL INVERTER NOC: NEC: STRING GRND GRND WIRE TAG# WIRE FROM-- CONDUIT QTY GAUGE: NCLUDESp1]GROOUallo RATING: AMP DE -RATE: FILL: OCP: 75°CRATING: CITY: AMPS SIZE TYPE O1 ARRAY TO JUNCTION BOX PV WIRE 6 #10 TRUNK CABLE 90, 40A x 0.96A x 0.80A = 30.72A 35A 12 x 1.0 x 1.25 = 15.00A #6 SBC O2 JUNCTION BOX TO COMBINER PANEL 3/4 ELECTRICAL 6 #10 THWN-2 90, 40A x 0.76A x 0.80A = 24.32A 35A 12 x 1.0 x 1.25 = 15.00A #8 THWN-2 CONDUIT O COMBINER PANEL TO MSP ELECTRICAL 3 #8 THWN-2 75" 50A x 0.94A x 1.00A = 47.OA 50A 34 x 1.0 x 1.25 = 42.50A #8 THWN-2 CONDUIT Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9 Location specific temperature obtained from ASHRAE 2017 data tables RECORD LOW TEMP 0"C AMBIENT TEMP (HIGH TEMP 2%) 330C CONDUIT HEIGHT 0.51 ROOF TOP TEMP 550C CONDUCTOR TEMPERATURE RATE ON ROOF 900C CONDUCTOR TEMPERATURE RATE OFF ROOF 75°C i......mono, 1.0.01 Ieeeeeeeei Ieeeeeeeeeei IeeeeE E 04.1eee flip 12 I= .... TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) ENPHASE Q CABLE TO BE ATTACHED TO RAIL MIN. 3-1/2" ABOVE ROOF SURFACE Solardeck box or UL 1741 Approved Equivalent to transition from Q-Cable to THWN-2 wire no fuse required r (N) Combiner Panel Enphase IQ Combiner X-IQ- AMl-240-3 64AI240V 16A 15A I Envoy-S I CLIMATIC SOLAR .,nmrc"be^SOY Wulbw 650 2nd LANE VERO BEACH, FL 32962, USA PHONE: 7725673104 FAX (772) 567-4553 v .cfhaticsolar.com I REVISIONS I DE$Q%PRON DATE I REV Point of Interconnect, Supply Side ILu EXISTING 240V/225A BUS BAR z ¢ rn RATING, Main Service Panel, Single LLI `-J' Phase, with a 200A Main Disconnect N z . LJJ lL' ZD U- LLi Cpw0 Z U W _ M LL.LL � dCID 200A (E)LOADS 45A J 0------------------- --- --------------------- ti G — I Existing Grounding Electrode System 120% RULE BUS BAR RATING X 120%) - MAIN BREAKER RATING = MAX. PV OCPD (225A x 120%) - 200 = 70A KINE DIAGRAM 11" x 17" SHEET NUMBER E-01 3NATURE WITH f Ek, , CI. i= .;1 WIRE WIRE WIRE WIRE TYPE TEMP WIRE TEMP CONDUIT WIRE TERMINAL INVERTER NOC: NEC: STRING GRND GRND WIRE TAG# WIRE FROM -- CONDUIT CITY GAUGE: IINNCWDDEESa1zGROUNDD RATING: AMP DE -RATE: FILL: OCP: 75°CRATING: QTy; AMPS SIZE TYPE O1 ARRAY TO JUNCTION BOX PV WIRE 6 #10 TRUNK CABLE 900 40A x 0.96A x 0.80A = 30.72A 35A 12 x 1.0 x 1.25 = 15.00A #6 SEC O2 JUNCTION BOX TO COMBINER PANEL 3/4 ELECTRICAL 6 #10 THWN-2 900 40A x 0.76A x 0.80A = 24.32A 35A 12 x 1.0 x 1.25 = 15.00A #8 THWN-2 CONDUIT O3 COMBINER PANEL TO MSP 3/4° ELECTRICAL 3 #8 THWN-2 75° 50A x 0.94A x 1.00A = 47.00A 50A 34 x 1.0 x 1.25 = 42.50A #8 THN-2 W CONDUIT ® [COMBINER PANEL TO MSP ELECTRICAL 3 #6 THWN-2 750 65A x 0.94A x 1.00A = 61.10A 65A 34 x 1.0 x 1.25 = 42.50A #8 THWN-2 CONDUIT Rooftop conductor ampacities designed in compliance with art. 690.6, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9 Location specific temperature obtained from ASHRAE 2017 data tables RECORD LOW TEMP 0°C AMBIENT TEMP (HIGH TEMP 2%) 33°C CONDUIT HEIGHT 0.5' ROOF TOP TEMP 55°C CONDUCTOR TEMPERATURE RATE ON ROOF 90°C CONDUCTOR TEMPERATURE RATE OFF ROOF 75°C 11 MICRO -INVERTERS IN BRANCH CIRCUIT#3 11 MICRO -INVERTERS IN BRANCH CIRCUIT#2 12 MICRO -INVERTERS IN BRANCH CIRCUIT#1 TERMINATOR CAP ON LAST CABLE CONNECTOR AC TRUNK CABLE (TYP) ENPHASE Q CABLE TO BE ATTACHED TO RAIL MIN. 3-1/2" ABOVE ROOF SURFACE (N) Combiner Panel Enphase IQ Combiner X-IQ- AM1-240-3 64A/240V Continuous, protection max 80A breaker on solar ouput; with 10 KAIC circuit breakers Solardeck box or UL 1741 Approved Equivalent to transition from Q-Cable to THWN-2 Wire no fuse required 2 I Envoys 3 l�� CLIMATIC SOLAR nn°waplamerpywlW°na 650 2nd LANE VERO BEACH, FL 32962, USA PHONE: 772567-3104 FAX (772) 5674553 www.climalicsolar.com It1 DESCRIPRDN I DAIS I REV I Point of Interconnect, Supply Side ul EXISTING 240V/225A BUS BAR W Q RATING, Main Service Panel, Single z i Phase, with a 200A Main Disconnect V5 W w Z) LLLU O LLI ZO Z U of _ (N) Lockable Blade Type M LL w a Fusible AC Disconnect L 00 a NEMA 3R 60A-2P 120/240VAC 45 A FUSES 200A (E) LOADS Existing Grounding Electrode System 120% RULE BUS BAR RATING X 120%) - MAIN BREAKER RATING = MAX. PV OCPD (225A x 120%) - 200 = 70A 3-LINE DIAGRAM 11" x 17" SHEET NUMBER E-01.1 : I C) "Ir SIGNATUREWITH SEAL' dl� 2 � I /��010 ELECTRICAL NOTES: 1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4. WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. B. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY -IN LUG. 10. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 11. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC ARTICLE 110.26. 12. ALL EQUIPMENT INSTALLED SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL) PER NEC ARTICLE 110.3. 13. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. 14. ALL LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION. THE LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 9.5 MM (3/8 IN) IN WHITE ON A RED BACKGROUND. 15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.8 (D). 16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.8 (C). SYSTEM NOTES: 1. ENPHASE IQ7 / 7PLUS MICROINVERTERS DO NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS OR EQUIPMENT GROUNDING CONDUCTORS. THE MICROINVERTERS ITSELF HAS CLASS II DOUBLE -INSULATED RATING, WHICH INCLUDES GROUND FAULT PROTECTION. 2. ENPHASE Q CABLE HAS NO NEUTRAL WIRE -(2 WIRE DOUBLE INSULATED CABLING) 3. MODULES ARE BONDED TO RAIL USING IRON RIDGE INTEGRATED GROUNDING. 4. RAILS ARE BONDED WITH UL 2703 RATED LAY -IN LUGS 5. SYSTEM IS UNGROUNDED 6. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA IRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC 250.64(C) 7. SUB -BRANCHES ARE CENTER -FED AT JBOX TO MAKE ONE TOTAL BRANCH CIRCUIT. 8. ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRAL TO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PER ENPHASE INSTALLATION INSTRUCTIONS, 9. ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READY PER NEC 690.12 SYSTEM DATA # STRINGS: 03 SMALLEST STRING: 11 LARGEST STRING: 12 TOTAL MODULES: 34 TOTAL INVERTERS: 34 SYSTEM RATINGS: 11.560kW DC STC BATTERY RATING: N/A INVERTER SPECIFICATIONS MANUFACTURER ENPHASE ENERGY IQ7-60-2-US MAX. DC VOLT RATING 48 VOLTS MAX. POWER AT 40 C 240 WATTS NOMINAL AC VOLTAGE 240 VOLTS MAX. AC CURRENT 1.0 AMPS MAX. OCPO RATING 20 AMPS MAX. PANELS/CIRCUIT 16 SHORT CIRCUIT CURRENT 15 AMPS PV MODULE RATING @ STC MANUFACTURER HANWHAQ.PEAKDUO BLK-G6+34OW MAX. POWER -POINT CURRENT (IMP) 10.02AMPS MAX. POWER -POINT VOLTAGE (VMP) 33.94 VOLTS OPEN -CIRCUIT VOLTAGE (VOC) 40.66VOLTS SHORT-CIRCUIT CURRENT (ISC) 10.52AMPS NOM. MAX. POWER AT STC (PMAX) 340 WATT MAX. SYSTEM VOLTAGE 1000 VDC VOC TEMPERATURE COEFFICIENT -0.27' °/d°C FSEC CIRTIFICATION # 401259 LABLES PHOTOVOLTAIC DC PER INVERTER RATED MPP CURRENT 10.02 A RATED MPP VOLTAGE 33.947V MAX SYSTEM VOLTAGE 40.66 V SHORT CIRCUIT CURRENT 10.52 V PHOTOVOLTIAC AC OUTPUT AC OUTPUT CURRENT 34.00A NOMINAL AC VOLTAGE 240V I JOHN ALGER, A PE #74730 PURSUANT TO CHAPTER 471 OF THE FLORIDA STATUTES, HAVE EVALUATED THIS SYSTEM AND IT'S INDIVIDUAL COMPONENTS AND CERTIFY THAT IT MEETS OR EXCEEDS THE MINIMUM STANDARDS IN 2017 FLORIDA BUILDING CODE 6TH EDITION 2017 FLORIDA BUILDING CODE 6TH EDITION RESIDENTIAL 2014 NEC CERTIFICATE OF AUTHORIZATION# 31930 ENGINEER OF RECORD JOHN L. ALGER PROFESSIONAL ENGINEER FL. LICENSE NO.74730 kilill* CLIMATIC SOLAR mn ble CMYWU1 650 2nd LANE VERO BEACH, FL 32962, USA PHONE: 772-567-3104 FAX. (772) 5674553 www.climaUcsolar.com REVISIONS DEB Fnm DATE REV PROJECT NAME W W Q rn o a�i ai Z J .�. W � LL. W 0 0 W LL 0 m C7 SHEETNAME ELECTRICAL NOTES SHEET SIZE ANSI B 11" x 17" SHEETNUMBER E-02 , , SIGNATURE WITH SEAL ,'i _ C, ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.17(B), NEC 2014: 690.17(E), NEC 2011: 690.17(4) DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): NEC 2014:705.12(D)(3), NEC 2011:705.12(D)(4) PHOTOVOLTAIC SYSTEM COMBINER PANEL I DO NOT ADD LOADS I LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2016:705.12(D)(2)(3)(c), NEC 2014:705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019:705.12(B), NEC 2014: 705.12(1))(2)(3)(b), NEC 2011: 705.12(D)(7) LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JBIPULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690A3, NEC 2014: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER COOE(S): CEC 2019: 690.53, NEC 2014: 690.54, NEC 2011: 690.54 NOTES AND SPECIFICATIONS: • SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2014 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. • SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. .LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. .LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. • SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. • DO NOT COVER EXISTING MANUFACTURER LABELS. CLIMATIC SOLAR m,.,.uw•�nvrwmuo,n 650 2nd LANE VERO BEACH, FL 32962, USA PHONE: 772-5673104 FAX: (772) 567-4553 www.dimafesolar.com I DESDWPTION I DATE I � IN W U Z w 0 as W w QLo rn ch Q Z J LL. LLI Cr LLO rya �w ca co co LABELS SHEET SIZE ANSI B 11" x 17" SHEET NUMBER :SIGNATURE WITH SEAL ' powered by lq�WDUO THE IDEAL SOLUTION FOR: LtresideRooftop al buldiays n residential bulMinBs Engineered in Germany I p(ELLS ' I MP BRRND PV- O`ua11��Teeta4 4 .:.. �" \.2019 ,G y. ID.40032 587 ^ Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.5%. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-Ilght and temperature behavior. 7- ENDURING HIGH PERFORMANCE O ` Long-term yield security with Anti LID and Anti PID Technology', Hot -Spot Protect and Traceable Quality Tra.QThe. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). p A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty'. Q� STATE OF THE ART MODULE TECHNOLOGY or '� Q.ANTUM DUO combines cutting edge cell separation and innovative wiring with Q.ANTUM Technology. 1 APT test conditions according to IEC/TS 62804-1:2015, method B (-1500V. 168N 2 See data sheet on rear for further information MECHANICAL SPECIFICATION Format 68.5 x 40.6 x L26 in (Including frame) (1740 x 1030 x 32mm) .. zu`iuu x Weight 43.91bs(19.91g) Front Cover 0.13in(3.2mm) thermally pre -stressed glass + - + with anti -reflection technology „awaew.ealrrl.ar Back Cover Composite film _ aerPumm3 Frame Black anodized aluminum Cell 6. 20 menocrystelline Q.ANTUM solar half cells Junction8ox 2.09-3.98x1.26-2.36 x 0.59-0,71 In (53-101 x 32-60 x 15-18mm), Protection class IP67, with bypass diodes Cable 4mm2 Solar cable; (+) e45.31n (1160 mm), 1-) 1,45.3In(1150mm) Connector Staubil MC4, Hanwha Q CELLS HQC4, Amphenol UTX, Renhe 05-6, Tangling TL-CableOlS, JMTHY JM601; IP68 or Friends PV2e; IP67 O I'0° L .avmmmro e.s ELECTRICAL CHARACTERISTICS j POWER CLASS 330 335 340 345 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE+5 W /-0 W) Powaret MPP1 Fur, IWI 330 335 340 345 Short Circuit Current3 Isc IA] 10.41 10.47 10.52 10.58 Open Circuit Voltage* E Vac IV] 40.15 40.41 40.66 40.92 Cumentat MPP I, (A] 9.91 9.97 10.02 10.07 Voltage at MPP VaRa IV] 33.29 33.82 33.94 34.25 Efficiency` a _ [%] a18.4 a18.7 1,19.0 a19.3 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Power at MPP Pew [W) 247.0 250.7 254.5 258.2 E Short Circuit Current 1¢ [A] 8.39 8.43 8.48 8.52 Open Circuit Voltage Vac IV] 37.86 38.10 38.34 38.59 Currentat MPP I, IAI 780 784 789 Z93 Voltegeat MPP V°°a IV] 31.66 31.97 32.27 32.57 'Meesurememtolerances Pw. s3%: lu: Vae s6%at STC: 1000 W/m; 25x2°C, AM 1_5 according to IEC 60904-3 •'800 W/m2, NMOT, spectrum AM Lb Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE j IS b. ... °3 a --'------"'-"._.--------- Eg ------------- a F °u ^ Po YELRe At least 98%of nominal power during first year. Thereafter max. 0.54% degradation per year. At least93.1% of nominal power up to 10 years. Al least 85%of nominal power up to 25years. All data within measurement toleranc. as. Full warranties in accordance with the warranty terms of the O CELLS sales organization of your respective country. 8°O ----- r---------- n_____- ? I a en zw Rae . Roa 3aoR OO IRR1pLWCarW/mr/ Typical module performance under low trmdlence conditions In comparison to STC conditions (25°C, 1000 W/m2) Temperature Coefficient of l.c a [%/Kl +0.04 Temperature Coefficient of Vw B (%/Kl -0.27 Temperature Coefficient of Puw y (%/K] -0.36 Normal Module Operating Temperature NMOT IT] 109t5.4(43x3°C) PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Veee M 1000(IEC)/1000(UL) Safety Class II Maximum Series Fuse Rating [ADC] 20 Fire Rating based on ANSI/UL 1703 C(IEC)/TYPE2(UL) Max. Design Load, Push/Pull' )Ibs/ftq 75(3600Pa)/55(2667Pa) Permitted Module Temperature -40°F up to+185°F Me.. Test Load, Push/Pull' [Ibs/ftq 113(5400Pa)/84(4000Pa) °^Continuous Duty (-40°C up to+85°C) 3See Installation Manuel QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL1703, VDE Quality Tested. CE-compliant, IEC 61215:2016, IEC 61730:2016. Application Class II, U.S. Patent No. 9.893,215 (solercells) DVE C E Acgus Number of Module. per Pallet KY Number of Pallets per 53' Trailer 28 Number of Pellets per 40' HC-Contalner 24 Pallet Dimensions (LxWx H) 71.5 x 45.3 x 48.0in(1815 x 1150 x 1220mm) Pallet Weight 15051bs(683 kg) Note: Installation insWctions must be followed. See the installation and operating manual or contact our technical service department for further Information on approved Installation and use of this product. Q CELLS 400 Spectrum LLS Center Drive, lne. 400ah.0C Center erica In.. 1400,Irvine, CA 92618, USA I TEL+19497485996 IEMAIL inquiry@us.q-cells.comI WEB www.q-cells.us Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ 7 and IQ 7+ Microinverters N To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro' and Enphase IQ 7+ Micro' dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy'", Enphase IQ Battery'", and the Enphase EnlightenTM monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready • Complies with advanced grid support, voltage and frequency ride -through requirements • Remotely updates to respond to changing grid requirements • Configurable forvarying grid profiles • Meets CA Rule 21 (UL 1741-SA) • The IQ 7+ Micro is required to support 72-cell modules. Enphase IQ 7 and IQ 7+ Microinverters Commonly used module pairings' 235 W - 350 W + 235 W -440 W + I Module compatibility -_ 60-cell PV modules only - - _ _ 60-cell and 72-cell PV modules - MaxiuI mm nput DC voltage - _ , 48 V 60 V Peak power tracking voltage 27 V -37 V - -27 V; 45 V r Operating range 16V-48V 16V-60V Min/Max start voltage 22 V / 48 V 22 V / 60 V 'Max DC short circuit current (module lsc) 15.A -_--__15A Overvoltage class DC port-- � DCporttiackfeedcurrent PV array configuration - 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Maximum continuous output power 240 VA 290 VA ----- - —, -------- — ---- — I Nominal (L-L) voltage/range- '— 240 V // - 206 V % -W - 240 V % 208 V % 211-264V V_ 183-229V -----_-----__._-- Maximum continuous output current 1.0 A (240 V) _183-229V__ 1.15 A (208 V) T211-264 1.21 A (240 V) 1.39 A (208 V) L,Nominal frequency Extended frequency range 47-68 Hz 47-68 Hz -i- --_ Cd hort circuftfaultcurrent ovei35ycles - 5.8Arms ,2 Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (206 VAC) •Overvoltageclass ACportIII----_�__ --III--—.-_.-__.___-__--.---. AC port backfeed current- ) -Power factor setting LO _ ________ Power factor (adjustable) —v_-_._., 0.851eading... 0.85 lagging 0.85 leading... 0.85 lagging pppiriprary fa 240 V 0208 V 0240 V (d208 V CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range. _ _ _ _ - _ _ 40°C to+65°C _ _ _ _ Relative humidity range 4%to 100%(condensing) i____ _ct_- I Connectortype _ —_-1 _ _. __. -- - - to _ ___ _ MC4 (or Amphenol H4 UTXwith additional Q DCGSadapter)'- _ _ _— --_—____ --_ Dimensions (HxWxD) 212 mm x 175 mm x 30.2 mm (without bracket) Weight 1.08 kg (2.3816s) Cooling Natural convection - No fans I Approved for wet locations Pollution degree PD3 .__._-.._ Enclosure _-_- __-.. ___. .____.-____ __. _.__. Class II double -insulated, corrosion resistant polymeric enclosure -- - -_-- _ -Environmental category/ UV exposure rating NEMA Type 6/outdoor Communication Power Line Communication (PLO) I Monitoring __.___. Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. rDisconnecting means The ACand DCconnectorshavebeen evaluatedand approved by UL for use as the load: ea I f required by NEC 690. - -- - -- - Compliance ^` ,disconnect -- - ---- - ----- -- - CA Rule 21 (UL 1741-SA) UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. No enforced DC/AC ratio. Seethe compatibility calculator at https'//ennhas om/n-uW,noort/module-comnatlbllity. 2. Nominal voltage range can be extended beyond nominal if required by the utility. 3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. vEN PHAS E. To learn more about Enphase offerings, visit enphase.com -0:1 EN PHASE. 02020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7, Enphase IQ 7+, Enphase IQ Battery, Enphase Enlighten, Enphase IQ Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. 2020-01-06 Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) U� LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner 3' with Enphase IQ Envoy'' consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart • Includes IQ Envoy for communication and control • Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Simple • Reduced size from previous combiner • Centered mounting brackets support single stud mounting • Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • UL listed IQ Combiner 3 rear data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 far data plan) microinverters. (Available in the US, Canada,Mexico, Puerto Rico, and the US Virgin Islands, d LTE-M/5-year data plan) _where there is adequate cellular service in the installation area.)_ CT Split core current transformers enable whole home consumption metering (+/- 2.5 0). • Consumption monitoring Is required for Enphase Storage Systems _ _ rWireless USB adapter _ - -' � Installed at the Iq E'nvoy. Forcolnmsnicatiolis witft Enphase Encharge"' strrage asd Enphase j ICOMMS-KIT-01 Enpower' smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner' I and allows redundant wireless communication with Encharge and Enpower� _ circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. BRK-10A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 Power lrnecamer(communicatlontindge pair),, quant I7FInepair - J XA-PLUG-120-3� Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) System voltage~' -_—�-_ 120/240 VAC, 60 Hz- ff Eaton BR series busbar rating 125 Max. continuous current rating (output to grid) 65 A rrM''ax.fuse%circuit rabng(output) 90A T r Branch circuits(solar and/or storage) w Upto four 2-pole Eaton BR series Distributed Generation(DG) breakers only (not included) Max. continuous current rating Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included _— _.. _..m --- --- —_-._-._ ._-_.__..______.._____ __-__ ._._ --- __ (PfOdUCl100 Metering CT 200 A solid core pre -installed and wired to IQ Envoy i ht-...__._____­ ent ternperature ran ng (sure environrrental- sizes cm --Natural convection, plus heat shield 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Main lug combined output: 10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors ways follow local code requirements for conductor sizing. !Integrated WI-Fi 802.11b/g/n __--__-- Ethernet Optional, 802.3, CatSE (or Cat 6) UTP Ethernet cable (not Included) 'Cellular Optional, CELLMobEM-01.(3G)or CELLMODEM-03(4G)or CELCMODEM-M1 (4G based LTE-M) -1 f—f lnrh,dndl i compnance, rAmomer " "", ..«. ., ,�,.,. �, , o„ --- i Production metering: ANSI C12.20 accuracy class 0.5(PV prgduction)____�_____,_;�______ Compliance, IQ Envoy �,. UL 60601-1/CANCSA 22.2No. 61010-1-1 To learn more about Enphase offerings, visit enphase.com 0 2018 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the ENPHASE. trademarks of Enphase Energy, Inc. 2019-11-04 0M ENPHASE. AM& IRON RIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather events. Not just the worst storms in years, but the worst storms in 40 years. High winds capable of ripping panels from a roof, and snowfalls weighing enough to buckle a panel frame. A XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads into the building structure. l Their superior spanning capability requires fewer roof attachments,_ reducing the number of roof 1 , penetrations and the amount of installation time. i Force -Stabilizing Curve Sloped roofs generate both vedical and lateral forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails Is specially designed to Increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible with Flat & Pitched Roofs XR Rails are konRidge offers compatible with a range of tilt leg FlashFoot and options for flat other pitched roof roof mounting attachments. applications. XR Rail Family Corrosion -Resistant Materials All XR Rails are made of marine -grade _ o, aluminum alloy, then protected with an anodized finish. Anodizing prevents surface a' and structural corrosion, while also providing a more attractive appearance. �® XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. It achieves 6 foot spans, while remaining light and economical. 6'spanning capability Moderate load capability Clear anodized finish Internal splices available Rail Selection Ir XR100 XR100 is the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8' spanning capability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans 12 feet or more for commercial applications. • 12'spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. L-Mount I QMLM / QMLM-ST Elevated Water Seal Technology® ITEM NO. DESCRIPTION CITY. THIS EDGE TOWARDS ROOF RIDGE FLASHING, ROUNDED CORNERS, 9" X 12" X .040", .438" HOLE, 5052. 1 I MILL 2 L-FOOT, 7' X 3.30" FOR .438" O.D. FASTENER, 2-1 /16" SLOT, 6061- 1 T6 6005A-T61, MILL 3 WASHER, SEALING, 5/16" ID X 3/4" OD, EPDM BONDED SS 1 4 LAG SCREW, HEX HEAD, 5/16" x 4', 18-8 SS 1 30 HEX WASHER HEAD, 5/16" X 4-1/2', P5 STRUCTURAL SCREW, QMPV, T18-BSS 1 12.00 �5 (4.20)RAL 3.00 E ON ST �-- 4.50 ONLY YINISHES 9.00 — 2.00 0.408 1.00 O N MILL, 3.3� .90 FINISHES to Quickly{- PV° 40 TITLE:(25 (354) 4.04 275 QMLM 8 QMLM-SMOUNT, 2 1 /16"SLOT QMLM QMLM-ST UNL OMERWBESPKnED: SIZE DRAWNBY: AAP REV DIMFntI0NSA9EW WCHES rote+AucEs: „ DATE 4/d/2019 9¢puOvw.M"""1l ugowl,tC4wvpg6m[SpevRs9nc(cN6eww'Iw. unPwCCVCIW w9M0ewSwwM ewmIW,11rt wnmr"Pv m9oxaavc""ouwws�aarzP. C0PYRIGR02019GUICKM0UMPV IRAC11011P1: 1/8 00 N01SC/.1E M.�WMG N`'OPIA EDEIMN. !.I9 iHRai PIACEDKlwt a09R SCNE 1:1 waGM:0.9565 SHEETI OFI 5 4 3 2 1 BI 7.2.3-44 (wick Mount PV° RESPECT THE ROOF Apr-2019 Rev 6 L-Mount Installation Instructions Installation Tools Required: tape measure, roofing bar, chalk line, stud finder, caulking gun, sealant compatible with roofing materials, drill with 7/32" or 1/8" bit, drill or impact gun with 1/2" socket. Locate, choose, and mark centers of rafters to be Carefully lift composition roof shingle with rooting insert hashing Derween rsc anG am comae. ague mounted. Select the courses of shingles where bar, just above placement of mount. Remove up so top edge of flashing is at least YV higher mounts will be placed. nails as required and backfill holes with aproved than the butt -edge of the 3rd course and lower sealant. See "Proper Flashing Placement" on next flashing edge is above the butt -edge of lst course. page. Mark center for drilling. If attaching with lag bolt use a *ha" bit (Lag). Use a '/e" bit (ST) for attaching with the structural screw. Drill pilot hole into roof and rafter, taking care to drill square to the roof. Do not use mount as a drill guide. Drill a 2" deep hole into rafter. Prepare lag bolt or structural screw with sealing washer. Using a 1k-inch socket on an impact gun, drive prepared lag bolt through L-foot until L-foot can no longer easily rotate. DO NOT over -torque. NOTE: Structural screw can be driven with T-30 hex head bit. BI 7.2.3-44 Clean off anysawdust, and Fit hole with sealant Place L-foot onto elevated flute and rotate L-foot to compatible with roofing materials. desired orientation. You are now ready for the rack of your choice. Follow all the directions of the rack manufacturer as well as the module manufacturer. NOTE: Make sure top of L-Foot makes solid contact with racking. Apr-2019 Rev 6 Reference and Tips flashing positioned tab low: Nails not removed. Keyway allows water'entry: -Remove nails.. � 3rdcour3e Moisture/debris �� 2nd course accumulation can ® �� cause early shingle degradation: e tst course. NOMM INCORRECT Position Correct Position Acceptable Position No, shingle cutting required If shinglecutting is required, a %!' gap between blockand shingle is recommended. Additional tips and information for installing mounts: Is See Quick Tips videos on nail removal, and more at: http://www.quickmountpv.com/support/videos.htmt ■ It is not necessary or advisable to use nails or other fasteners to secure the perimeter of the flashing. ■ The L-Mount is made to work with standard and high -definition composition/asphalt and wood shingle roofs with 5" to 5-5/8" courses. If the exposed surface of the course exceeds this measurement you may need to use our Classic Shake Mount instead. ■ Depending on the season and climate, size and location of seal tabs, and quality of the shingles, the seal tabs that adhere the shingle courses together may not effectively seal the shingles to the flashings. If this is the case, simply add several quarter -sized dabs of manufacturer accepted sealant or asphalt roofing cement, meeting ASTM D 4586 Type II, between the flashing and the shingle above. ■ Mounts should not be installed in areas of the roof susceptible to ice damming. Water ponding under the shingles can reach the bolt penetration. Is Take care not to damage the roofing material while working on the roof. Removing stone granules and deforming the shingles in any way can shorten the lifespan of the roofing. The value of the solar array is directly affected by the condition of the roof it is attached to. ■ CAUTION: Prior to installation, check that proper screw embedment will be achieved for the necessary site load and roofing configurations. Apr-2019 Rev 6 Quick Mount P1 /® RESPECT THE ROOF 925-478-8269 1 www.quickmountpv.com I info@quickmountpv.com 2700 Mitchell Dr. I Walnut Creek, CA 94598 BI 7.2.3-44 0 2019 by Quick Mount PV. All rights reserved.