Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Evaluation Report; Polyglass SBS and APP Modified Bitumen Roof Systems
RECEIVED File Copy n AUG 0 7 20211 MEMO I eft. Certificate of Authorization Q32455 J✓ Permitting Department 353 Christian Street, Unit #13 (� St. Lucie Count' Oxford, CT 06478 v"(L� rr�� REVIEWED F® (203) 2.62-9245 ENGINEER E ALUATE TESTCODE CIPPIN01 IAk1^CCERTIFY Polyglass USA, Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 ion Rdpbrt P9290.02.08-R24 FL1654-R26 Date of Issuance: 02/11/2008 Revision 24: 10/14/2019 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5, plus an 81-page Appendix Prepared by: saus'~it_ _ec�rsxo Robert I.M. Nieminen, P.E. -•i sF •`.,ces C:�<V The faaimile seal appearing vras authorized by Robert Florida Registration No. 59166, Florida OCAANE1983 "; ,°!; `.••"' Nieminen,P.E.oil 10/14/2019. This does not za,e as an electronically signed document CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 02018, NEMO ETC, LLC WA MEMO I etc Entity Exam Reference Date Kniimt Exam Reference Date FM(TSf1867) FM 4470 3031334 02/15/2000 M-D(CER15921 HVHZ Various Was Various FM(TSf18671 FM 4470 3000857 01122/2000 M-D(CER1592) Prop. for Rev. 30-0823 10/12/2010 FM (TST1867) FM 4470 3004091 01/1212000 I UL (QUA9525) Quality control Service confirm 09/13/2018 This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1: ROLL -GOODS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Base Sheet J Base Ply Elastovent ASTM D4897 N/A N/A Pol lass G2 Base i ASTM D4601 N/A II Dlyflex SA Base ASTM D4601 N/A 11 Elastobase SA ASTM D4601 ASTM D6163, Table 2 N/A S II I Polyglass Base ASTM D6509 N/A N/A SBS Membranes Elastoshield HT ASTM D6162 S III Elastoshield HT G ASTM D6162 G III Elastoshield HT FR ASTM D6162 G III Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V ASTM D6163 S I Elastoflex SA V FR ASTM D6163 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase P ASTM D6164 S I Elastoflex SA Base HD ASTM D6164 S I Elastoflex 56 ASTM D6164 S I Elastoflex 56 HP ASTM D6164 5 II Elastoflex V G ASTM D6163 G I Elastoflex V G FR ASTM 06163 G I Elastoflex S6 G ASTM 06164 G I Elastoflex SG G FR ASTM D6164 G I Polyfresko G SBS ASTM D6164 G I Polyfresko G SBS FR ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G 1 Elastoflex SA P ASTM D6164 G I Elastoflex SAP FR ASTM D6164 G I Polyreflect ASTM D6164 S I NEMO ETC, U.0 Evaluation Report P9290.02,08-RZ4 Certificate nfAuthoruation#32455 6O.EDITION (2017)FBC NON-HVHZ EVALUATION FL3654-1126 Polyglass Modified Bitumen Roof Systems; (954) 233.1330 Revision 24: 10/14/2019 Page 3 of 5 SMEMO I etc. mom m D ofik•coo mar m m :m m m•mo D System Deck (Nat¢1) Primer Roof Cover (Note 15) MDP (psi) No. loin! Treatment Base Ply Ply Cap Ply SVt ADHERING BASE PLY:. - APA rated, 7/16 OSO joints are covered with 4-inch wide strips of Elastoflex SA V, rolled into place to Elastoflex SA V Plus or (Optional) SRS-SA, SBS- SBS-SA, APP-SA, SBS- -52.5 W-206 CAT, 0.418 in., None create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA Exposure 1 OSB Exposure W-207 min. 15/32-Inch None None SBS-SA (Opt S-5A, 505- 50.5-SA, APP-SA,SBS- -90.0 plywood T APP-TA TA, APP-TA Min. 15/32-inch SBS-SA (Opho S-SA, SBS- SBS-SA, APP-SA,SBS- W-208 plywood PG100 None TA, APP-TA TA, APP•TA Min. 15/32-inch Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 975 WQW plywood (onaiPGI00 (Optional) place to create continuous bond. Elastoflex SA V FR TA, APP-TA TA, APP-TA Min. 15/32-Inch POLYBRITE 745 or SBS-SA (Optional)SDS-SA, SBS. SBS-SA, APP-SA,SBS- -1D5.0 W-210 plywood W83D00 None TA, APP-TA TA, APP-TA Min. 15/32-inch Piywoodjoints are covered with 4-Inch wide strips of Elastoflex SAV Plus, rolled into Elastoflex SA V Plus or (Optional)SBS-SA, SBS- SOS -SA, APP-SA, SBS- -135.0 W-231 plywood (Optional) PG300 I I place to create continuous band. Elastoflex SA Plus FR TA, APP-TA TA, APP-TA HYBRID SYSTEMS WITH SELr-ADHERING APP BASE PLY:' W-212 Min. 15/32-inch (Opllonal)PG300 None APP-SA-H (Optional)APP-TA APP-TA -90.0 plywood W-213 Min. 15/32-Inch (Optional) PG30D I PIYWDDdjoimS are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into I APP-SA-H (Optional)APP-TA APP-TA -135.0 plywood place to create continuous bond. HYBRID SYSTEMS WpD SEEP -ADHERING SBS BASE PLY: W-274 Min. 15/32-Inch None None SBS-SA-M (Optional) SBS-TA -90.0 plywood W-215 Min. 15/32-inch pG10D None 565-SA-H (Optional)SBS-TA SBS-TA -97.5 plywood W-216 Min. 15/32-inch (Dplional)PG100 Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into SBS-SA (Optional) SBS-TA SBS-TA -97.5 plywood place to create continuous bond. W 217 Min. 15/32-inch POLYBRITE 745 or None SBS-SA.H (Optional) SBS-TA SBS-TA -105.0 plywood WB3000 NEMO ETC, LLC Certificate of Authorization 932455 ©2018 NEMO ETC, LLC 6n' EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08.R24 for F1.1654-R26 Revision 24: 10/14/2019 Appendix 1, Page 33 or 81 System Deck INote 11 Primer Roof Nc. APA rated, 7/16 !Dint Treatment W-182 CAT, 0.418 in., None 058joints are covered with 4-Inch wide strips of Elastoflex SA V, rolled into pl: Exposure 1 OSB create continuous bond. W-183 Min. 15/32-inch plywood None None W-184 Min. 15/32-inch olvwood (Optional) PG100 None W-185 Min. IS/32-inch plywood PG300 JWW-187 Min. 15/32-inch Plywood (Optional) PG300 Min. 15/32-inch POLYBRITE 745Plywood WB3000 Min. 15/32-Inchp!Ywcod (OPn)100Min. 15/32-Inch ei,,,., A (Optional) PG100 NEMO ETC, LLC Certificate of Authorization 832455 Prepared by: Robert Nieminen, PE-59166 None Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rbl!e, place to create continuous bond. None Plywood joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, roller place to create continuous bond. Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Pius, roller place to create continuous bond. ONEMOletc. :over (Note 15)' - - Base Ply Ply Cap Fly MOP (psQ ce to Elastoflex SA V Plus or foptional)SSS-SA, SBS- SBS-SA, APP-SA, SBS. Elastoflex SA V Plus FR TA, APP-TA TA APP-TA -52.5 SBS-SA (Optional)SBS-SA, SBS- SBS-SA, APP-SA,SBS- TA, APP-TA TA, APP-TA -90.0 Polyflex SA Base (Optional) APP-TA APP-TA -90.0 SBS-SA (Optional) SBS-SA, 58S- 5BS-SA, APP-SA, 5BS- TA, APP-TA TA, APP-TA -97.5 1 into Elastoflex SA V or (Optional) 585-SA, SBS- SBS-SA, APP-SA, SBS- Elastoflex SA V FR TA, APP-TA TA, APP-TA -97.5 SBS-SA (Optional) SBS-SA, 5B5- SBS-SA, APP-SA, SBS- TA, APP-TA TA, APP-TA -105.0 into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- Elastoflex SA V Plus FR TA, APP-TA TA APP-TA -135.0 Into Polyflex SA ease (Optional)APP-TA APP-TA -135.0 6t" EDITION (2017) FBC NON-HVHZ EVALUATION Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Evaluation Report P9290.02.08-R22 for FL1654-RZ4 Revision 22: 04/11/2019 Appendix 1, Page 29 of 69 *Nnvio I etc, TABLE DECK APPLICATION TYPE DESCRIPTION PAGE 1A Wood New or Reroof (Tear -Off) A-7 Bonded Insulation, Bonded Roof Cover 5 113 Wood New or Rereef(Tear-Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-10 1C Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 11-12 1D Wood New, Remof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 13 lE Wood New, Reroof (Tear -Of() or Recover C Mech. Attached Insulation, Bonded Roof Cover 13-16 1F Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-20 1G Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 21-25 SH Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 26-32 31 Wood New or Reropf(Tear-Off) F Non -Insulated, Bonded Roof Cover 33 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 34-36 2B Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 37-43 2C Steel or Structural concrete New, Reroof (Teat -Off) or Recover D-1 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 44-45 2D Steel or Structural concrete New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Velociflex, Bonded Roof Cover 46-47 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 48-58 38 Structural concrete New or Reroof(Tear-Off) F Non -Insulated, Bonded Roof Cover 58 4A Lightweight concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 59-62 40 Lightweight concrete New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 63 4C Lightweight concrete New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 64-68 5A Cementitious wood fiber New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 69 59 Cementitious wood fiber Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 70.71 5C Cementitious wood fiber Reroof (Tear -Off) or Recover a Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 72 SO Cementitious wood fiber Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 72 SE Cementitious wood fiber Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 72 6A Existing gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 73.75 6B Existing gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded insulation, Bonded Roof Cover 76 6C Existing gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 76 6D Existing gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 76 A 7il Various Recover A-1 Bonded Insulation, Bonded Roof Cover 77-81 713 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 81 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: Y-Wood: Minimum 0.75-inch penetration. i Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck. > Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published Installation instructions. NEMO ETC, LLC Evaluation Report P9290.02.08-1124 for FL1654.R26 Certificate of Authorization 1132455 6"' EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 10/14/2019 02018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 81