Loading...
HomeMy WebLinkAboutEval 20468.11VFL20468_R3_AE_(d)R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Therma Tru Corporation Fiber -Classic and Smooth -Star Exterior Swinging Exterior Door 118 Industrial Drive Composite Edge Glazed Fiberglass Single Door w/Sidelites Doors Assemblies Edgerton, OH 43517 Inswing/Outswing Phone 419.298.1740 'Impact' Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468.11 require further engineering analysis by a licensed engineer or registered architect. 6. Fiber -Classic & Smooth -Star Door and Sidelite panels require the use of "J" part numbers and must be stained or painted within six months of installation 7. See drawing FL-20468.11 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 01460131 ASTM E1886-02, E1996-02 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E330-02, E331-00 TEL 01460274 ASTM E1886-05, E1996-05 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E330-02, E331-00 TEL 06-1031-4 ASTM E1886-02, 1996-02, ASTM E330-02 Testing Evaluation Lab.,lnc. V.K. Wright TEL 06-0831-1 AAMA/WDMA/CSA101/I.S.2/A440-05 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E1886-02, E1996-02 TEL 01461612 ASTM E1886-05, E1996-09 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E330-02, E331-00 TEL 01461939 ASTM E330-02, E331-00 Testing Evaluation Lab.,lnc. V.K. Wright ASTM E1886-05, E1996-09 2. Miami Dade NOA Materials Testing 16-1117.01 Butacite° PVB Interlayer (Kuraray) 17-0712.05 Saflex® PVB Interlayer (Eastman Chemical Company®,,,%jU112j;,,,. 3. Drawing No. Prepared by ``�� ��s�slj49� ®9®® Signed & Sealed by No. FL-20468.11 RW Building Consultants, Inc. (CA#9813) ®ooLyndon F. Schmidt, P.E. 4. Calculations Prepared by eoo�®• �. o �`� ned & Sealed by `�jg*L?don Anchoring RW Building Consultants, Inc. (CA#9813) w PJO 43�ff�9 • F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and ' Management Institute, certifying that Therma Tru Corporation is STATE OF •P o ��1.—� manufacturing products within a quality assurance program that complies 0 A, j,• �o 'oio��` with ISO/IEC 17020 and Guide 53. • L O R ��•�;��� Lyndon F. Schmidt, P.E. FL PE1 No.3409 Sheet 1 of 1 4