HomeMy WebLinkAboutEval 20468.11VFL20468_R3_AE_(d)R W R W Building Consultants, Inc.
BConsulting and Engineering Services for the Building Industry
C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197
Florida Board of Professional Engineers Certificate of Authorization No. 9813
Product
Category
Sub Category
Manufacturer
Product Name
Therma Tru Corporation
Fiber -Classic and Smooth -Star
Exterior
Swinging
Exterior Door
118 Industrial Drive
Composite Edge Glazed Fiberglass Single Door w/Sidelites
Doors
Assemblies
Edgerton, OH 43517
Inswing/Outswing
Phone 419.298.1740
'Impact'
Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru
Corporation based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florida Product Approval, Department of
Business & Professional Regulation.
RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein.
Limitations:
1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements
excluding the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing
or stucco.
3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does
not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and
FBC Sections 1609.1.2.2 & R301.2.1.2.1.
4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction.
5. Site conditions that deviate from the details of drawing FL-20468.11 require further engineering analysis by a licensed engineer or
registered architect.
6. Fiber -Classic & Smooth -Star Door and Sidelite panels require the use of "J" part numbers and must be stained or painted within six
months of installation
7. See drawing FL-20468.11 for size and design pressure limitations.
Supporting Documents:
1. Test Report No.
Test Standard
Testing Laboratory Signed by
TEL 01460131
ASTM E1886-02, E1996-02
Testing Evaluation Lab.,lnc. V.K. Wright
ASTM E330-02, E331-00
TEL 01460274
ASTM E1886-05, E1996-05
Testing Evaluation Lab.,lnc. V.K. Wright
ASTM E330-02, E331-00
TEL 06-1031-4
ASTM E1886-02, 1996-02, ASTM E330-02
Testing Evaluation Lab.,lnc. V.K. Wright
TEL 06-0831-1
AAMA/WDMA/CSA101/I.S.2/A440-05
Testing Evaluation Lab.,lnc. V.K. Wright
ASTM E1886-02, E1996-02
TEL 01461612
ASTM E1886-05, E1996-09
Testing Evaluation Lab.,lnc. V.K. Wright
ASTM E330-02, E331-00
TEL 01461939
ASTM E330-02, E331-00
Testing Evaluation Lab.,lnc. V.K. Wright
ASTM E1886-05, E1996-09
2. Miami Dade NOA
Materials Testing
16-1117.01
Butacite° PVB Interlayer (Kuraray)
17-0712.05
Saflex® PVB Interlayer (Eastman Chemical
Company®,,,%jU112j;,,,.
3. Drawing No.
Prepared by
``�� ��s�slj49� ®9®® Signed & Sealed by
No. FL-20468.11
RW Building Consultants, Inc. (CA#9813)
®ooLyndon F. Schmidt, P.E.
4. Calculations
Prepared by
eoo�®•
�. o
�`� ned & Sealed by
`�jg*L?don
Anchoring
RW Building Consultants, Inc. (CA#9813)
w PJO 43�ff�9 • F. Schmidt, P.E.
5. Quality Assurance
Certificate of Participation
issued by National Accreditation and
'
Management Institute, certifying that Therma Tru Corporation is
STATE OF •P o ��1.—�
manufacturing products within a quality assurance program that complies 0 A, j,• �o
'oio��`
with ISO/IEC 17020 and
Guide 53.
• L O R ��•�;��� Lyndon F. Schmidt, P.E.
FL PE1 No.3409