HomeMy WebLinkAboutDesign pressure calcs.,
ALL AIERICA►N
SHU71`T�RS GLASS
1038 Donna Road, Ms1 (palm Beach, FL 33409
(561) 712-9882 - tiuwwallamericanshwers-com
Property Information Building Information
Owner: MARCELLO, MARY PAT Wind Zone: 170 MPH,
Address: 1948 WILDCAT COVE DR Exposure Category: B
FORT PIERCE, FL 34949 Minimum.. Building Dimension: 47 ft.
Mean Roof Height: 20 ft.
IL Risk Category: lI
Design Pressure Calculations
Opening Location Device Device Device Max Positive 1EMax Negative
Number Zone Width (in) Height (in) [Elevation (ft) 11 Pressure (psf) Pressure (pst)
1 Int _ 7 0.0 0.0
2 Int 164 -- 113$ — 7 — 25.6 -2.8.2
3 Int 218.5 f 138 7 ----- 25.0 -27.6
Prepared in accordance whit: ASCE 7-10, Chapter 30. Wind Loads - Componenis and Cladding. Oh Edition (2017) Florida Building Code.