Loading...
HomeMy WebLinkAboutConstruction Materials Testingw\ DES TeNo.: 003rmMUNIVi_-RSAL Date Typed: February 12, 2020 tuENGINEERING SCIENCES d Consultants In: Geotechnical Engineering • Environmental Sciences Geophysical Services • Materials Testing • Threshold Inspection Building Code Administration, Compliance Inspection & Plan Review 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Construction Materials Testing Services FIELD AND LABORATORY REPORT COVER PAGE Client: K. Hovnanian Homes, LLC 3601 Quantum Boulevard Suite 101 Boynton Beach, FL 33426 Project: Waterstone Subdivision Lot 4 5214 Armina Place P1912-0098, Ft. Pierce, St. Lucie County, FL As requested, Universal Engineering Sciences, Inc. (UES) representative(s) performed construction materials testing and/or field inspection services on the above project. Testing results and/or inspection observations are reported on the attached sheets. The contents of this package are summarized below: Scope of Work Work Order No. Date Type of Report 121235-1 1 02/10/2020 In -Place Density Test Report w/Activity Record We hope this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact the undersigned. RECEIVED FF6 2 B ";20 ST. Lucie County, Permitting [CC Email: ECoca@0-lov.com Sincerely, Universal Engineering Sciences, Inc. Certificate of Authorization No. 00000549 Richard E. Hhaglin, P.E. FLORIDA Professional Engineer No. 48796 ! r Vi— A < a e LIES Prl . A No: 0310.2000045.0003 LIES DOCS No: �f J ' ' ! {- I LIES Report No: 121235-1 ARC 021020 L!lENGINEERING SCIENCES On -Site Time (hrs): 1.00 Consultants In: Geotechnical Engineering * Environmental Sciences Lab Time (hrs): 0.00 Geophysical Services 9 Materials Testing • Threshold Inspection Travel Time (hrs): 0.50 Building Code Administration, Compliance Inspection&Plan Review Total Time (hrs): 1.50 820 Brevard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978 Activity Record Client: K. Hovnanian Homes, LLC 3601 Quantum Boulevard Suite 101 Boynton Beach, FL 33426 Project: Waterstone Subdivision Lot 4 5214 Armina Place P1912-0098, Ft. Pierce, St. Lucie County, FL Date of Activity: Monday, 10 February, 2020 Technician: Cliff Cherrnay As requested, a Universal Engineering Sciences Technician was present at the above referenced project site for the purpose of earthwork testing for the Lot 4. While on site, the technician observed the general condition of the areas to be tested and performed 4 density test(s) for Lot 4. All test(s) were performed in accordance with the ASTM D-6938 Nuclear Gauge Method and were found to meet the project compaction requirements of 95% of the maximum dry density per ASTM D-1557. UNIV ENGINEERI Consultants In: Geotechnical Geophysical Services • Mate Building Code Administration, 820 Brevard Avenue, Rockledge, FL 329SS �IRSAL NG SCIENCES Engineering • Environmental Sciences rials Testing • Threshold Inspection Compliance Inspection & Plan Review - P: 321.638.0808 - F: 321.638.0978 i UE',;,�r:uject No: 0310.2000045.0003 UES DOCS No: UES Report No: 121235-1 DT 021020 In -Place Density Test Report Client: K. Hovnanian Homes, LLC 3601 Quantum Boulevard Suite 101 Boynton Beach, FL 33426 Project: Waterstone Subdivision Lot 5214 Armina Place P1912-0098, Ft. Pierce, St. Lucie County, FL Area Tested: Lot 4 Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 02/10/2020 Lab: ASTM D1557 Modified Proctor Technician: Cliff Cherrnay Requirements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions only and do not address the condition of the underlying soils below the tested depths. Test No. _ Location of Test Range Depth (inch) Proctor (2) Field Dry Density (PCF) Field Moisture % % Compaction Comments (3) 1 NMI Test 0-1 it 12.00 25323 108.1 7.8 98 A 2 N/E Test 0-1 ft 12.00 25323 108.3 8.6 98 A 3 S/E Test 0-1 ft 12.00 25323 106.8 8.2 97 A 4 SMI Test 0-1 ft 12.00 25323 107.7 9.1 98 A (1) Ref. Datum: 0 = Top of Final Grade (2) Maximum Optimum Proctor Dry Moisture # Density Content 25323 110.0 11.0 This test was performed without deviation from AS7M procedures. (3) Comments Key A. Compaction meets min. requirements B. Compaction does not meet min. requirements C. Moisture does not meet requirements D. Recompaction required E. Recompacted, Retested, Meets Requirements This report shall not be reproduced, except in full, without the written approval of Universal Engineering Sciences.