Loading...
HomeMy WebLinkAboutConstruction Plans; Single Hung WindowsNOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1 X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6063—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS RE -Ir_'N . A.rUR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REVISIONS I REV I DESCRIPTION I DATE I APPROVED 15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE #6 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16.FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.. 19. ALL FASTENERS TO BE CORROSION RESISTANT. 20. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KSI .048" THICK MINIMUM I TABLE OF CONTENTS 1 ISHEET NO.1 DESCRIPTION 1 1 NOTES 2 — 3 ELEVATIONS 4 — 9 INSTALLATION DETAILS 10 1COMPONENTS MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT NOTES A.R. REV 08-03383 1 — SCALE NTS I DATE 01 /17/ 1 9 I SHEET 1 OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-668-0609 rllomasa@lrlomaspe.com SIGNED: 0210712019 Luis R. Lomas P.E. FL No.: 62514 71 5/8" FRAME HEIGHT 36" FRAME WIDTH FT 10I MAX. O.C. 3 1/2" —{ 1 i 10" MAX O.C. 3 1/2" 71 FF HE 36" FRAME WIDTH 10" MAX. O.C. 3 1/2" MAX. / a 3 1/-2A 10" O MAX O.C. 5/8" AME IGHT 4 3 1 A 185 ALUMINUM SINGLE HUNG WINDOW 185 EXTERIOR VIEW FLANGE & FINLESS INSTALLATION — 3 1/2" MAX. JNG WINDOW DESIGNER EXTERIOR VIEW FLANGE & FINLESS INSTALLATION DESIGN PRESSURE RATING IMPACT RATING +60.01-70.OPSF NONE 36" X 71 518" UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS FRAME AREA DOES NOT EXCEED 17.9 FT2 NOTES: 1. SASH SIZE: 34 15/16" X 36 1/16" 2. D.L.O.: 33 1/4" X 32 7/16" REVISIONS I REV I DESCRIPTION I DATE I APPROVED MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT FLANGE & FINLESS ELEVATIONS DRAWN: DWG NO. A.R. 1 08-03383 SCALE NTS DATE 01/17/19 1 SHEET OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-698-0609 illomas@lrlomaspe.com REV SIGNED: 0210712019 O�\J�S R I I Ll0 /z Q v •`,�G E NSF•gcP -�� •; STATE III Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS APPROVED SEALANT BEHIND FLANGE EXTERIOR APPROVED SEALANT BEHIND FLANGE WOOD FRAMING OR 2X BUCK BY OTHERS 1/2" MIN. EDGE DISTANCE 1 1/4" MIN. METAL EMBEDMENT STRUCTURE BY OTHERS 1 /4" MAX. SHIM SPACE APPROVED SEALANT BEHIND FLANGE #10 WOOD SCREW INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. SHIM SPACE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 EXTERIOR APPROVED SEALANT BEHIND FLANGE M ETP STRUCTUR BY OTHER REVISIONS 1/2" MIN. REV DESCRIPTION DATE EDGE DISTANCE 1 1/4" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE 1/4" MAX. �— r SHIM SPACE 1/2 MIN INTERIOR + EDGE T DISTANCE #10 WOOD SCREW #10 SMS OR SELF DRILLING WOOD FRAMING SCREW OR 2X BUCK BY OTHERS I#10 SMS OR INTERIOR SELF DRILLING SCREWS SILL TO BE SET IN A BED OF APPROVED SEALANT VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION 1/4" MAX. SHIM SPACE 1/2" MIN. EDGE DISTANCE EXTERIOR APPROVED SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 1/4" MAX. SHIM SPACE INTERIOR EXTERIOR APPROVED METAL J STRUCTURE APPROVED BY OTHERS SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION SIGNED: 0210712019 MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT FLANGE INSTALLATION DETAILS DRAWN: DWG NO. REV A.R. 08-03383 — SCALE NTS DATE 01/17/19 SHEET OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@lrlomaspe.com \\\\\5 11R1 I to °�s• � TARE OF , &' O. .kip OR10' G\ilk: Luis R. Lomas P.E. FL No.: 62514 2" MIN. EDGE DISTANCE CONCRETE/MASONRY ° BY OTHERS ° °° d ° 1 1/4" MIN. ° d OPTIONAL 1X BUCK ° ° ° ° d- EMBEDMENT SEE NOTES 3 — 7 SHEET 1 1/4" MAX. APPROVED SHIM SPACE SEALANT BEHIND FLANGE EXTERIOR APPROVED SEALANT BEHIND FLANGE OPTIONAL 1 X BUCK SEE NOTE 3 — 7 SHEET 1 3/16" TAPCON SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. SHIM SPACE CONCRETE/MASONRY BY OTHERS a d„ ° d e a ° d d VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION REVISIONS I REV I DESCRIPTION I DATE I APPROVED 1 1/4" MIN. EMBEDMENT v CONCRETE/MASONRY 1/4" MAX. BY OTHERS SHIM SPACE D� 3/16" TAPCON ?` INTERIOR 0 v v o° v D 2" ° MIN. D EDGE EXTERIOR DISTANCE < D 1 ° APPROVED SEALANT BEHIND FLANGE OPTIONAL 1 X BUCK SEE NOTES 3 — 7 SHEET 1 JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 0210712019 MI WINDOW A AND DDOORET R ET DOORS, ssoT GRATZ, PA 17030 \\\\\\5 tRI�.L�� `\�i•��GENS+F•"9c��-�� =*• 0 51� SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT ;.ps�ttr7T(,z�= FLANGE INSTALLATION DETAILS ��0 • 5 EOF, tug ��0��';�[OA. RIOQ'•G\�� -���isS�ONA DRAWN: DWG NO. O8 83 REV - SCARCE NTS DATE 01/17/19 S03 5 OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@Irlomaspe.mm LUIS R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT FxTl=alnQ BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 1 /2" MIN. EDGE DISTANCE 1 1/4" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE #10 WOOD SCREW INTERIOR M ETAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. F SHIM SPACE r VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 r:yTFRInR BACKER & APPRC SEAL METAL STRUCTURE BY OTHER`: 1/2" MIN. EDGE DISTANCE 1/4" MAX. SHIM SPACE 10 SMS OR SELF DRILLING SCREW INTERIOR VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. SHIM SPACE REV 1 1/4" MIN. EMBEDMENT 1 /2" MIN. EDGE DISTANCE #10 WOOD SCREW % WOOD FRAMING OR 2X BUCK BY OTHERS #10 SMS OR SELF DRILLING SCREWS REVISIONS DESCRIPTION DATE APPROVED 1/4" MAX. SHIM SPACE INTFRInR EXTERIOR BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION T 1 /2" MIN. EDGE DISTANCE 1 L M ETAL STRUCTURE BY OTHERS I r 1/4" MAX. SHIM SPACE I I IAITGRInp EXTERIOR BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS DRAWN: DWG NO. A.R. 1 08-03383 SCALE NTS DATE 01/17/19 1 SH'ET 6 OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasOrlomaspe.com SIGNED: 0210712019 ir• �0%`�� 61• �TAT� OF .� REv �;!°**:c[ORIOP• �� ijl�Ss,ONA 11C�\�� Luis R. Lomas P.E. FL No.: 62514 2" MIN. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS ° ° 1 1 /4" MIN. OPTIONAL 1X BUCK ° ° ° ° °d °. EMBEDMENT SEE NOTES 3 — 7 ° SHEET 1 a 1 /4" MAX. BACKER ROD SHIM SPACE & APPROVED SEALANT BACKER ROD & APPROVED SEALANT OPTIONAL IX BUCK SEE NOTE 3 — 7 SHEET 1 CONCRETE/MASONRY BY OTHERS EXTERIOR 3/16" TAPCON INTERIOR SILL TO BE SET IN A BED OF APPROVED SEALANT L__j 1/4" MAX. F SHIM SPACE a VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION 1 1/4" MIN. EMBEDMENT CONCRETE/MASONRY BY OTHERS ° 3/16" TAPCON REVISIONS REV I DESCRIPTION I DATE I APPROVED I v 1 /4" MAX. e SHIM SPACE ° INTERIOR ° ° 0 v ° I 2" ° MIN. EDGE ° °7BACKER EXTERIOR DISTANCE v ROD °ROVED T 1 X BUCK SEE NOTES 3 — 7 SHEET 1 JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT FINLESS INSTALLATION DETAILS DRAWN: DWG NO. REV A.R. 08-03383 — SCALE NTS DATE 01/17/19 1 SHEET OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomascmirlomaspe.wm SIGNED: 0210712019 db����i v, •v�G E N 5�•9cP�� ONA 11E:V\�� Luis R. Lomas P.E. FL No.: 62514 APPROVED SEALANT BEHIND FIN #6 WOOD SCREW 3/8" MIN EDGE DISTANCE 3/8" MIN EDGE DISTANC #6 WOOD SCREW APPROVED SEALANT BEHIND FIN 1 1/2" MIN. EMBEDMENT VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION WOOD FRAMING BY OTHERS 1/4" MAX. SHIM SPACE 1/4" MAX SHIM SPACE WOOD FRAMING BY OTHERS REVISIONS REV I DESCRIPTION I DATE I APPROVED I 1/4" MAX WOOD FRAMING SHIM SPACE BY OTHERS I 1 1 /2" INTERIOR MIN. EMBEDMENT #6 WOOD SCREW APPROVED SEALANT EXTERIOR BEHIND FIN 3/8" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL OR 2X BUCK INSTALLATION WOOD FRAMING NOTES., 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT FIN INSTALLATION DETAILS DRAWN: DWG NO. A.R. 1 08-03383 SCALE NTS DATE 01/17/19 1SHEET OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rl/omasQalrlomaspe.com SIGNED. 0210712019 it � _...._ _•; '� Luis R. Lomas P.E. FL No.: 62514 APPROV ^ SEALA BEHIND #6 SMS OR SELF DRILLING SCREW 3/8" MIN EDGE DISTAI` FXTFL71ll L7 u 3/8" MIN EDGE DISTANCE INTERIOR #6 SMS OR SELF DRILLING SCREW VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION APPROVED SEALANT BEHIND FIN METAL STRUCTURE BY OTHERS _ 1/4" MAX. SHIM SPACE 1 /4" MAX SHIM SPACE METAL STRUCTURE BY OTHERS REVISIONS REV I DESCRIPTION I DATE I APPROVED I 1 /4" MAX METAL STRUCTURE SHIM SPACE BY OTHERS INTERIOR #6 SMS OR SELF DRILLING SCREW APPROVED SEALANT EXTERIOR BEHIND FIN 3/8" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED 1N ACCORDANCE WITH ASTM E2112 MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT FIN INSTALLATION DETAILS DRAWN: DWG NO. REV A.R. 1 08-03383 — SCALE NTS DATE 01/17/19 1SHEET OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rIlomas@Ulomaspe.com SIGNED: 0210712019 b E N S',:�gsir� TAT E OF �'°F'.'c� ORIOP •G�i�\� Luis R. Lomas P.E. FL No.: 62514 2 3/15" 1 1 5/16" FINLESS FRAME HEAD CM-18553 ALUMINUM 6063-T5.050" THICK 2 3/16" 13 a I FLANGE FRAME HEAD CM-18501 ALUMINUM 6063-T5.050" THICK 2 3/16" 7- 2 5/16" i '�Hl FIN FRAME HEAD CM-18508 ALUMINUM 6063-T5.050" THICK 2 5/16" ---I FINLESS FRAME SILL CM-18554 ALUMINUM 6063-T5.055" THICK 2 5/16" 3 3/8" I _H FLANGE FRAME SILL CM-18502 ALUMINUM 6063-T5.055" THICK 2 5/16" —{ 3 3/4" ll�l FIN FRAME SILL CM-18509 ALUMINUM 6063-T5.055" THICK t•I 2 3/16" 1 FINLESS FRAME JAMB CM-18513 ALUMINUM 6063-T5.050" THICK FLANGE FRAME JAMB CM-18503 ALUMINUM 6063-T5.050" THICK 2 3/8" FIN FRAME JAMB CM-18510 ALUMINUM 6063-T5.050" THICK REVISIONS I REV I DESCRIPTION I DATE I APPROVED I MEETING RAIL CM-18504 ALUMINUM 6063-T5.055" THICK 1 7/16" 2 5/16" SASH BOTTOM RAIL CM-18555 ALUMINUM 6063-T5.050" THICK ---{ I-- 3/16" + II 1' GLAZING NG BEAD V-663 RIGID PVC .050" THICK --{ 1 5/8" rE[ 1 7/4" LOCK RAIUSTILE CM-18505 ALUMINUM 6063-T5.062" THICK �--{ 1 3/8" -- 15/16" SASH STILE CM-18507 ALUMINUM 6063-T5.050" THICK MI WINDOW AND DOORS, LLC. 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 185 ALUMINUM SINGLE HUNG WINDOW 36" X 72" NON —IMPACT COMPONENTS DWG NO. A.R. 1 08-03383 NTS IDATE 01/17/19 ISHEET10 OF 10 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasCOldomaspe.com SIGNED: 0210712019 �,•.y�GENs�.'9sy *• 0 51 •it= o � TATE OF :' REv ORIOP• ONA 1,�aG\�� Luis R. Lomas P.E. FL No.: 62514