Loading...
HomeMy WebLinkAboutConstruction Plans; Sliding Exterior Door AssembliesNOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. 8. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4"- 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED ALUMINUM 6005—T5. 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, WITH SAFETY GLAZING. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14.FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #14 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REVISIONS I REV I DESCRIPTION I DATE I APPROVED 15.FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1 7/8" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16.FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #14 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. ALL FASTENERS TO BE CORROSION RESISTANT. 18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063—T5 FU=30KSI .048" THICK MINIMUM 19. APPROVED CONFIGURATIONS: OX, XO, XX, OXXO, PX, XP, PXXP, PIX, XIP, PIXXIP, XIX, OIX, XIO, PIIX, XIIP, XIIX, OIIX, XIIO, PIIIX, XIIIP 20. DOOR ASSEMBLIES INSTALLED WHERE OVERHANG RATIO IS EQUAL OR GREATER THAN 1.0 DO NOT REQUIRE WATER INFILTRATION RESISTANCE. OVERHANG RATIO = OVERHANG LENGHT/OVERHANG HEIGHT. TABLE OF CONTENTS SHEET NO. DESCRIPTION 1 NOTES 2 — 3 ELEVATION, ANCHORING LAYOUTS AND CHARTS 4 PLAN VIEWS 5 — 23 INSTALLATION DETAILS 24 SILL RISER DETAILS SIGNED: 0611412017 MI DOOREET RS LLC % R.WEST ssoWINDOWS MA ```\J GRATZ, PA 17030 v,•\,\GENSF•gil+ 0 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT — (r NOTES ~� ; STATE OF "J": �CQR�QP DRAWN: DWG NO. REV 08 50E 087 - G\ � s .. ��i/s'ONA 11 t\ SS Luis R. Lomas P.E. SCALE NTS DATE 04/18/17 1 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 FL No.: 62514 434-688-0609 rllomas@Irlomaspe.mm ' REVISIONS 6" MAX 96" MAX FRAME HEIGHT 191" MAX FRAME WIDTH 16" MAX O.C. 6" MAX —1 O � X y X f X 0 ;0// L_ 0 0 SERIES 120 ALUMINUM SLIDING GLASS DOOR NON -IMPACT 2, 3, & 4 TRACK (OXXX) EXTERIOR VIEW FINLESS & FLANGE INSTALLATION WITH STANDARD SILL DESIGN PRESSURE RATING IMPACT RATING +25.01-55.OPSF NONE WHERE WATER PENETRATION RESISTANCE IS REQUIRED NOTES: 1. MAXIMUM PANEL SIZE: 48 518" x 93 112" 2. MAXIMUM D. L.O.: 40 518"x 85 112" WITH 2 518" & 3 112" SILL EXTENDERS DESIGN PRESSURE RATING IMPACT RATING ±55.OPSF NONE WHERE WATER PENETRATION RESISTANCE IS REQUIRED WITH STANDARD SILL 2 518" & 3 112" SILL EXTENDERS DESIGN PRESSURE RATING IMPACT RATING ±55.OPSF NONE WHERE WATER PENETRATION RESISTANCE IS NOT REQUIRED (2) ANCHORS PER LOCATION SEE CHARTS #1, #2 & #3 FOR NUMBER OF LOCATIONS I REV I DESCRIPTION I DATE I APPROVED Chart#1: Units with 2 name is Number of anchor locations required (2 anchors per location) Frame Frame Width (in) Height 48.00 60.00 72.00 84,00 96,00 (in) H& S Jamb H& S Jamb H& S Jamb H& S Jamb H& S Jamb 80.00 4 6 4 6 5 6 6 6 7 6 84.00 4 6 4 6 5 6 6 6 7 6 90.00 4= 6 4 6 5 6 6 6 7 6 96.00 4 7 4 7 1 5 1 7 6 7 7 7 Chart#2: Unitswith 3 nanels Number of anchor locations required (2 anchors per location) Frame Frame Width (in) Height 72.00 90.00 108.00 126.00 144.00 (in) H& S Jamb H& S I Jamb_ I H& S I Jamb I H& S I Jamb I H& S I Jamb 80.00 5 16 6 6 7 6 9 6 10 6 84.00 5 6 6 6 7 6 9 6 10 6 90.00 5 1 6 1 6 1 6 1 7 1 6 1 9 1 6 1 10 1 6 96.00 5 1 7 1 6 1 7 1 7 1 7 1 9 1 7 1 10 1 7 Chart#3: Units with 4 oanels Number of anchor locations required (2 anchors per location) Frame - Frame Width (in) Height 96.00 120,00 144.00 16&00 192.00 (in) H 8 S Jamb H& S Jamb H 8 S Jamb H 8 S Jamb H 8 S Jamb 80.00 7 6 8 6 10 6 11 6 13 6 84.00 7 6 8 6 10 6 11 6 13 16 90.00 7 6 1 8 1 6 1 10 1 6 11 1 6 113 6 96.00 7 1 7 1 8 1 7 1 10 1 7 11 7 13 7 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT ELEVATION DWG NO. A.R. 1 08-03087 SCALE NTS PATE 04/18/17 I SHEET OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasC&Irlomaspe.com SIGNED: 06/14/2017 OF -4 R�s. WRty, ///1141111111 A Luis R. Lomas P.E. FL No.: 62514 191" MAX FRAME WIDTH F" neev __j 1--- I l 16 6" MAX ---I -- —— 6, I I 96" I I I I I I MA MAX FRAME HEIGHT I POCKET UN I SEPARATE] I TO BE REVII BUILDING 0 I I I 1 6' SERIES 120 ALUMINUM SLIDING GLASS DOOR NON -IMPACT 2, 3, & 4 TRACK (PIXXIP) EXTERIOR VIEW FINLESS & FLANGE INSTALLATION WITH HOOK STRIP WITH STANDARD SILL DESIGN PRESSURE RATING IMPACT RATING +25.01-55.OPSF NONE WHERE WATER PENETRATION RESISTANCE IS REQUIRED WITH 2 5/8" & 3 1/2" SILL EXTENDERS DESIGN PRESSURE RATING IMPACT RATING ±55.OPSF NONE WHERE WATER PENETRATION RESISTANCE IS REQUIRED REVISIONS I REV I DESCRIPTION I DATE I APPROVED HOOK STRIP (1) ANCHOR PER LOCATION SEE CHART 1 #1, #2 & #3, I SHEET 2 FOR I NUMBER OF I LOCATIONS 1 I I I )CKET UNDER :PARATEAPPROVAL I ) BE REVIEWED BY I IILDING OFFICIAL I I I J .. VD SILL (2) ANCHORS PER✓LOCATION. SEE CHARTS #1, FOR NUMBER OF LOCATIONS #2 & #3 SIGNED: 0611412017 WITH STANDARD SILL 25/8"&31/2"SILLEXTENDERS MI 650DOWS AWEST RDEDOORST REETLLC `,\`SRII�J/0�Ajv,'// DESIGN PRESSURE RATING IMPACT RATING GRATZ, PA 17030 v •��G E N,96 SERIES 120/130/140 ALUMINUM SLIDING 0 btSo ±55.OPSF NONE GLASS DOOR - NON -IMPACT NOTES: ELEVATION �� • TAT OF 1. MAXIMUM PANEL SIZE., 48 5/8"x 93 1/2" WHERE WATER PENETRATION RESISTANCE IS NOT REQUIRED Q 2. MAXIMUM D.L.0.:405/8"x851/2" DRAWN: DWG N0. REV /Fs,[pR10..,`,G�� SCALE GATE �$ s03087 — '/��SJ O t,�\ NTS 04/18/17 3 OF 24 HARDWARE SCHEDULE L. ROBERTO LOMAS P.E. Luis R. Lomas P.E. DEM ROLLER ASSEMBLY 2 PER PANEL W FROM EACH END OF BOTTOM RAIL 1432WOODFORD RD LEWISVILLE, NC27023 FL No.: 62514 X HANDLE, 1 PER OPERABLE PANEL AT LOCK STILE, 39" FROM THE BOTTOM RAIL _ 434-688-0609 rllomasOolrlomaspe.mm 0=lrPOCKET N OPPOSITE) XI X XIIO (OIIX OPPOSITE) PIIIX (XIIIP OPPOSITE) PIXXIP XIO (OIX OPPOSITE) XIP (PIX OPPOSITE) MIX REVISIONS I REV I DESCRIPTION I DATE I APPROVED PXXP POCKET POCKE- OXXO PIIX (XIIP OPPOSITE) LAYOUTS SHOWN AS REFERENCE ONLY. PANELS MAYBE MIXED & MATCHED AS NECESSARY MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR - NON -IMPACT PLAN VIEWS DRAWN: DWG NO. A.R. 1 08-03087 'CAE NTS DATE 04/18/17 1 SHEET4 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rllomas@Irlomaspe.com SIGNED: 0611412017 0 /Z��i r STATE OF ;•�: REv �i�O��d':c[ORIOP• �� Luis R. Lomas P.E. FL No.: 62514 r WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS /0" MIN. (STANCE MIN. "TT j 0 V ON11 REVISIONS REV DESCRIPTION DATE 1 3/8" MIN. 1/4" MAX. EMBEDMENT SHIM SPACE INTERIOR 5/8" MIN. EDGE DISTANCE #14 WOOD II I I I� � EXTERIOR SCREW / 1 u WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 WOOD SCREW . iAil IilAilSILL TO BE SET II� 1�►y��l_ II. V►1�il_ BED. APPROVED SEALANT SHIM SPACE 5/8" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION BACKER ROD & APPROVED SEALANT ,JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 2 TRACK FINLESS INSTALLATION DETAILS DRAWN: DWG NO. A.R. 08-03087 SCALE NTS DATE 04/18/17 SHEETS OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@lrlomaspe.com APPROVED SIGNED: 0611412017 o v. v�G E NSF•'9P�y REV %�•� �� 'e�5:0._ Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT METAL STRUCTURE BY OTHERS 5/8" MIN. EDGE DISTANCE REVISIONS I REV I DESCRIPTION I DATE I APPROVED 14" MAX. IM SPACE 5/8 MIN. EDGE DISTANCE >MS OR DRILLING V 5/8" MIN. EDGE DISTANCE VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 2 JG ILL TO BE SET J A BED OF ,PPROVED SEALANT 1 /4" MAX. F SHIM SPACE #14 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS BACKER .. & APPROVED SEALANT ­4 1 /4" MAX. JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR - NON -IMPACT 2 TRACK FINLESS INSTALLATION DETAILS DRAWN: DWG NO. A.R. 1 08-03087 SCALE NTS DATE 04/18/17 1 SHEET 6 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@lrlomaspe.c m REV SIGNED: 0611412017 v;•���ENs�, -a 0 ,,61251 TAT OF ' 11111I 111�" Luis R. Lomas P.E. FL No.: 62514 2 3/16" MIN 1 7/8" MIN REVISIONS SEPARATION EDGE DISTANCE r REV DESCRIPTION DATE CONCRETE/MASONRY d BY OTHERS 1 1/4" MIN. 1 1/4" MIN. EMBEDMENT a'. a ' + EMBEDMENT SHIM SPACE OPTIONAL 1 X BUCK e' < a 4 SEE NOTES 3 — 7 SHEET 1 o.. . v 1 7/8" v... o INTERIOR BACKER ROD 1/4" MAX. MIN. v & APPROVED SHIM SPACE EDGE SEALANT DISTANCE 9 1 0� 0 1/4" TAPCON ov ° 2 3/16" MIN SEPARATION o EXTERIOR 1 < a a v 1/4" TAPCON v . EXTERIOR INTERIOR o. ° CONCRETE/MASONRY BY OTHERS ' BACKER ROD & APPROVED OPTIONAL 1X BUCK SEALANT SEE NOTE 3 — 7 6-- ��� SHEET 1 1/4" TAPCON SILL TO BE SET a IN A BED OF APPROVED SEALANT BACKER ROD I�JI 1/4" MAX. & APPROVED r SHIM SPACE SEALANT OPTIONAL 1X BUCK a `. SEE NOTE 3 — 7 w 1 1/4" MIN SHEET 1 . n''e ,d e'er . e'. ,a :. CONCRETE/MASONRY ° ' BY OTHERS �3/ MIN 1 7/8" MIN SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEMASONRY INSTALLATION JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 2 TRACK FINLESS INSTALLATION DETAILS DRAWN: DWG N0. A. R. 08-03087 SCALE NTS DATE 04/18/17 SHEET7 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasC7alrlomaspe.wm APPROVED SIGNED: 0611412017 \��11111 I II!!l�jj `NN�J�S dh����i �r,•���+ENS,�•giP *' e,-6�?61 c (�f1r TAT . OF REv �i��'�'�c►S.'c[�RIQQ•�'� 4 NAIL Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS 9 7a" MIN. IISTANCE MIN. NTT I REW REVISIONS REV DESCRIPTION I DATE 1 3/8" MIN. 1/4" MAX. EMBEDMENT r SHIM SPACE TI INTERIOR 5/8" MIN. EDGE DISTANCE #14 WOOD J 11 II I1 � EXTERIOR SCREW u WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR U U NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. _ 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 WOOD SCREW SILL TO BE S IIII"'III III'''III Ills s dll I II►Y`III I IIi 11I I II�71I_IN A BED OF APPROVED SEALANT SHIM SPACE MIN EMBEDMENT 5/8" MIN EDGE DISTANCE VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION DRAWN: A.R. BACKER ROD J & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 3 TRACK FINLESS INSTALLATION DETAILS DWG NO. 08-03087 NTS JDATE 04/18/17 1 SHEET OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasCo7lrlomaspe.c m APPROVED SIGNED: 0611412017 d/z �r GENe*:._(ems<� REV I %"" • �1JP Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS I BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT METAL STRUCTURE BY OTHERS I 5/8" MIN. EDGE DISTANCE a /4" MAX. IM SPACE SMS OR DRILLING W VERTICAL CROSS SECTION 5/8" MIN. EDGE DISTANCE METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 2 IG ILL TO BE SET I A BED OF ,PPROVED SEALANT 1 /4" MAX. SHIM SPACE REVISIONS I REV I DESCRIPTION I DATE I APPROVED 5/8" MIN. EDGE DISTANCE l #14 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS BACKER . & APPROVED SEALANT 1 1 1/4" MAX. JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 3 TRACK FINLESS INSTALLATION DETAILS A.R. 1 08-03087 SCALE NTS DATE 04/18/17 1 SHEET 9 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rll0MaS@IrI0Masp0.MM SIGNED: 0611412017 RJ!i�FS1 "'111111111�``" Luis R. Lomas P.E. FL No.: 62514 4 7/16" MIN 1 7/8" MIN. SEPARATION EDGE DISTANCE CONCRETE/MASONRY n° <a .. • a ' a a ° BY OTHERS a a' 1 1/4" MIN. < n • ° ° ":. EMBEDMENT 1 1/4" MIN. < &EMBEDMENT OPTIONAL 1 X BUCK a ... ° e' a a 4 SEE NOTES 3 — 7 SHEET 1 1 7/8" &AAPPROVED nn �7� S IM SPACE EDGE SEALANT ffllllttoo33llfflll ,.,I DISTANCE EXTERIOR 0 BACKER ROD & APPROVED SEALANT OPTIONAL 1 X BUCK ' SEE NOTE 3 — 7 SHEET 1 CONCRETE/MASONRY BY OTHERS 1/4" TAPCON NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 4 7/16" 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE MIN DESIGNED IN ACCORDANCE WITH ASTM E2112 SEPARATIC INTERIOR 1/4" TAPCON SILL TO BE SET IN A BED OF / II APPROVED SEALANT y jl yU u U 1/4„ MAX. JL�u r SHIM. SPACE d 7SEPARATION 1 1/4" MIN 44 :EMBEDMENT MIN 1 7/8" MIN EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION REVISIONS I REV I DESCRIPTION I DATE I APPROVED -I v . v' v ' 1/4" TAPCON o' e v CONCRETE/MASONRY n BY OTHERS OPTIONAL 1X BUCK SEE NOTE 3 — 7 SHEET 1 1/4" MAX. SHIM SPACE BACKER ROD & APPROVED SEALANT INTERIOR EXTERIOR JAMB INSTALLATION DETAIL CONCRETE/MASONRYINSTALLATION SIGNED:0611412017 MI WINDOWS 650 WEST ANDDOORSLLC STREET ``` N GRATZ, PA 17030 ` v•`,�GENS�•9�' SERIES 120/130/140 ALUMINUM SLIDING / _ *� Oy6z5 � = GLASS DOOR — NON —IMPACT 3 TRACK FINLESS INSTALLATION DETAILS TATE OF .0 Owc No. ]REV � . �ORia . • � � A.R. 08-03087 — ���S:41_•. • SCALE NTS DATE 04/18/17 SHEET 10 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC27023 434-688-0609 rllomasC lrlomaspe.com '�Illllllll"- Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT EXTERIOR BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION G /a" MIN. ]STANCE REV 3/8" MIN MIN. EMBEDMENT "ENT T �{ 5 MIN. EDGE DISTANCE ;REW #14 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 #14 WOOD SCREW 5/8" MIN EDGE DISTANCE SILL TO BE SET IN A BED OF APPROVED SEALANT 1 /4" MAX. r SHIM SPACE `` I 1 3/8" MIN EMBEDMENT BACKER ROD & APPROVED SEALANT REVISIONS DESCRIPTION DATE 1 /4" MAX. r SHIM SPACE INTERIOR EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 4 TRACK FINLESS INSTALLATION DETAILS DRAWN: DWG NO. RE% A.R. 08-03087 — scALE NTS DATE 04/18/17 SHEET11 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NO 27023 434-688-0609 rllomas@7/rlomaspe.c0m APPROVED SIGNED: 0611412017 �vJ•��CENS�•gJ 'o TATAfTT OF Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT I METAL STRUCTURE BY OTHERS 5/8" MIN. EDGE DISTANCE /4" MAX. IM SPACE SMS OR DRILLING N 5/8" MIN. VERTICAL CROSS SECTION EDGE DISTANCE METAL STRUCTURE INSTALLATION IG REVISIONS I REV I DESCRIPTION I DATE I APPROVED 5/8" MIN. EDGE DISTANCE I #14 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 ILL. TO BE SET I A BED OF PPROVED SEALANT 1 /4• MAX. F SHIM SPACE BACKER ,. & APPROVED SEALANT 1 1 /4" MAX. METAL, STRUCTURE INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 4 TRACK FINLESS INSTALLATION DETAILS DRAWN: DWG N0. OS— A.R. 03087 SCALE NTS DATE 04/18/1 7 SHEET 12 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NG27023 434-688-0609 rllomas@irlomaspe.00m SIGNED: 0611412017 N �•• J . �••�\C E NSrF•'9d REV I of I� , '�/1111111t'^ Luis R. Lomas P.E. FL No.: 62514 • •I CONCRETE/MASONRY BY OTHERS • I OPTIONAL 1X BUCK SEE NOTES 3 — 7 SHEET 1 BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT OPTIONAL 1X BUCK SEE NOTE 3 — 7 SHEET 1 CONCRETE/MASONRY BY OTHERS 4 7/16" MIN 1 7/8" MIN. SEPARATION �{ EDGE DISTANCE r d' °P' EXTERIOR 4 7/16" MIN SEPARATION VERTICAL CROSS SECTION CONCRETEIMASONRY INSTALLATION a ' 1 1/4" MIN. EMBEDMENT 4 a 1/4" MAX. SHIM SPACE 1/4" TAPCON NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 INTERIOR 1/4" TAPCON SILL TO BE SET II / II IN A BED OF II / II APPROVED SEALANT 1/4" MAX. ICJ r SHIM SPACE +� a d° a' d' 1 1/4" MIN EMBEDMENT ° a 1 7/8" MIN EDGE DISTANCE REV 1 1/4" MIN. EMBEDMENT 1 7/8" ..D MIN. c EDGE DISTANCE 4 7/16" MIN 1/4" TAPCON CONCRETE/MASONRY BY OTHERS REVISIONS DESCRIPTION DATE 1/4" MAX. SHIM SPACE �—� INTERIOR BACKER ROD & APPROVED OPTIONAL 1X BUCK SEALANT SEE NOTE 3 — 7 SHEET 1 JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 4 TRACK FINLESS INSTALLATION DETAILS DRAWN: I DWG NO. A.R. 1 08-03087 SCALE NTS DATE 04/18/17 1 SHEET 13 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rlloma.,.hlomasp..00m EXTERIOR APPROVED SIGNED: 0611412017 �.J v•��GEN`S'F•'9s�: *• •0,f 51 rr *? '5TATE OF REV oIVAI �l�/1}II Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT EXTERIOR BACKER ROD & APPROVED SEALANT INTERIOR MIN. IISTANCE MIN. AT T i REW 1 3/8" MIN. EMBEDMENT 1 5/8" MIN. EDGE DISTANCE #14 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 #14 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS 5/8" MIN VERTICAL CROSS SECTION EDGE DISTANCE WOOD FRAMING OR 2X BUCK INSTALLATION SILL TO BE SET IN A BED OF APPROVED SEALANT 1 /4" MAX. F SHIM SPACE 7 31 8' MIN EMBEDMENT BACKER ROD & APPROVED SEALANT REVISIONS DESCRIPTION I DATE 1 /4" MAX. SHIM SPACE INTERIOR EXTERIOR JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 2 TRACK FLANGE INSTALLATION DETAILS DRAWN: DWG NO. REV A.R. 1 08-03087 — scALE NTS DATE 04/18/17 1 SHEET14 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@lrlomaspe.com APPROVED SIGNED: 0611412017 0R10P G� /01111�NA 11���`\` Luis R. Lomas P.E. FL No.: 62514 ME STRUCTI BY OTHI BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT METAL STRUCTURE BY OTHERS 5/8" MIN. EDGE DISTANCE I 14 MAX. IM SPACE SMS OR DRILLING N 5/8" MIN. VERTICAL CROSS SECTION EDGE DISTANCE METAL STRUCTURE INSTALLATION 0 NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 2 JG ;ILL TO BE SET J A BED OF APPROVED SEALANT 1 /4" MAX. SHIM SPACE REVISIONS I REV I DESCRIPTION I DATE I APPROVED 5/ MIN. EDGE DISTANCE t #14 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS BACKER ,., & APPROVED SEALANT _1 1 /4" MAX. JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 2 TRACK FLANGE INSTALLATION DETAILS DRAWN: I DWG NO. A.R. 1 08-03087 SCALE NTS 10ATE 04/18/17 1SHEET 15 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasCaNdomaspemm SIGNED: 0611412017 *' 0a61 •'' 0; STATE OF` REv ��'�E►�:c[ORI�P;N %s�QNA 11E�C�`x Luis R. Lomas P.E. FL No.: 62514 r CONCRETE/MASONRY BY OTHERS OPTIONAL 1 X BUCK e ° SEE NOTES 3 - 7 SHEET 1 _ BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT OPTIONAL 1 X BUCK SEE NOTE 3 - 7 SHEET 1 CONCRETE/MASONRY BY OTHERS EXTERIOR 2 3/16" MIN 1 7/8" MIN. SEPARATION EDGE DISTANCE d 4 e ° < 9' 1 1/4" MIN. EMBEDMENT a 1/4" MAX. SHIM SPACE 1/4" TAPCON INTERIOR 1/4" TAPCON SILL TO BE SET IN A BED OF APPROVED SEALANT U 1 LJ 1/4" MAX. r SHIM SPACE +T a . . ° 1 d77 e. e 1 1/4" MIN ° ° ..° .a ° ° ° ., EMBEDMENT �23M/ �MN�17/8� MIN SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION CONCRETE/MASONRY INSTALLATION REV 1 1/4" MIN. EMBEDMENT 1 7/8" MIN. a EDGE DISTANCE ° 2 3/16" MIN 1/4" TAPCON ° �.v 0 CONCRETE/MASONRY -� }:, BY OTHERS LA -':�— OPTIONAL 1 X BUCK SEE NOTE 3 - 7 SHEET 1 REVISIONS DESCRIPTION DATE ] [ 1/4" MAX. SHIM SPACE INTERIOR EXTERIOR BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR - NON -IMPACT 2 TRACK FLANGE INSTALLATION DETAILS DRAWN: I DWG NO. A.R. 1 08-03087 SCALE NTS 10ATE 04/18/17 1SHEET 16 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasOalrlomaspe.com APPROVED SIGNED: 0611412017 v jEN&%. cp'`� *• 0,r61 ••*= o•/ TAT E OF ; w; %Q •_ REv ii�'ts.'c[0RMt- Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS EXTERIOR VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION G /A' MIN. ISTANCE MIN. "TT I ,REW REVISIONS REV DESCRIPTION DATE 1 3/8" MIN. 1/4" MAX. EMBEDMENT r SHIM SPACE 5/INTERIOR MIN. EDGE DISTANCE #14 WOOD JI II III I EXTERIOR SCREW WOOD FRAMING OR 2X BUCK BY OTHERS NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 #14 WOOD SCREW 5/8" MIN EDGE DISTANCE SILL TO BE SET IN A BED OF APPROVED SEALANT 1 /4" MAX. r SHIM SPACE Ii 1 3/8" MIN EMBEDMENT BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 3 TRACK FLANGE INSTALLATION DETAILS DRAWN: DWG NO. A.R. 08-03087 s!a NTS DATE 04/18/17 E17 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@7lrlomaspe.com REV I APPROVED SIGNED: 0611412017 1R I'L d/z�/�i ;t1,9 �oENs�._.cp�i= 0 5 Luis R. Lomas P.E. FL No.: 62514 METAL STRUCTURE BY OTHERS I BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT METAL STRUCTURE BY OTHERS 5/8" MIN. EDGE DISTANCE a /4" MAX. IM SPACE SMS OR DRILLING W 5/8" MIN. VERTICAL CROSS SECTION EDGE DISTANCE METAL STRUCTURE INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 2 JG ILL TO BE SET J A BED OF APPROVED SEALANT 1 /4" MAX. F SHIM SPACE REVISIONS I REV I DESCRIPTION I DATE I APPROVED 5/8" MIN. EDGE DISTANCE I #14 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS BACKER ,. & APPROVED SEALANT —I I_ 1 /4" MAX. JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 3 TRACK FLANGE INSTALLATION DETAILS DRAWN: DWG NO. Rn A.R. 1 08-03087 — SCALE NTS DATE 04/18/17 SHEEr 18 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@7lrlomaspe.Com SIGNED: 0611412017 BENS STATE OF Z *ZORID�.e• A p. �ONA �1��G\`\` Luis R. Lomas P.E. FL No.: 62514 WOOD FRAMING OR 2X BUCK BY OTHERS BACKER ROD & APPROVED SEALANT EXTERIOR BACKER ROD & APPROVED SEALANT WOOD FRAMING OR 2X BUCK BY OTHERS VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION � /pl, MIN. ISTANCE REV 3/8" MIN MIN. EMBEDMENT "TT 7 �5 MIN, EDGE DISTANCE 01.42 fl #14 WOOD SCREW WOOD FRAMING OR 2X BUCK BY OTHERS NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 #14 WOOD SCREW 5/8" MIN EDGE DISTANCE SILL TO BE SET IN A BED OF APPROVED SEALANT 1 /4" MAX. r SHIM SPACE 1{ 1 3/8" MIN EMBEDMENT REVISIONS DESCRIPTION DATE APPROVED 1 /4" MAX. SHIM SPACE INTERIOR EXTERIOR BACKER ROD JAMB INSTALLATION DETAIL & APPROVED WOOD FRAMING OR 2X BUCK INSTALLATION SEALANT MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 4 TRACK FLANGE INSTALLATION DETAILS DRAWN: DWG NO. A.R. 1 08-03087 SCALE NTS DATE 04/18/17 sHEEr20 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC27023 434-688-0609 rllomas@lrlomaspe.wm SIGNED: 0611412017 J````S IR �t/o�//�i *• 0 P61 o , TAY OF REV %�' .'c[ORIaP. sI0NA1.lE�G`�\ Luis R. Lomas P.E. FL No.: 62514 ME- STRUCTL BY OTHE BACKER ROD & APPROVED SEALANT BACKER ROD & APPROVED SEALANT METAL STRUCTURE BY OTHERS 5/8" MIN. EDGE DISTANCE /4" MAX. IM SPACE SMS OR DRILLING N 5/8" MIN. VERTICAL CROSS SECTION EDGE DISTANCE METAL STRUCTURE INSTALLATION R JG REVISIONS I REV I DESCRIPTION I DATE I APPROVED 5/8" MIN. EDGE DISTANCE I #14 SMS OR SELF DRILLING SCREWS METAL STRUCTURE BY OTHERS NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 ;ILL TO BE SET V A BED OF kPPROVED SEALANT 1 /4" MAX. r SHIM SPACE BACKER & APPROVED SEALANT J 1 1 /4" MAX. METAL STRUCTURE INSTALLATION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT 4 TRACK FLANGE INSTALLATION DETAILS DRAWN: DWG NO. REV A. R. 08-03087 — SCALE NTS DATE 04/18/17 1SHEET21 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomas@Irlomaspe.Com SIGNED: 0611412017 Luis R. Lomas P.E. FL No.: 62514 , CONCRETE/MASONRY BY OTHERS e d -d° °e d. n < a, d OPTIONAL 1X BUCK ° SEE NOTES 3-7 SHEET 1 BACKER ROD & APPROVED SEALANT EXTERIOR BACKER ROD & APPROVED SEALANT OPTIONAL 1X BUCK -- SEE NOTESHEET 1 e ° a'd' ° e CONCRETE/MASONRY BY OTHERS 4 7/16" MIN_ SEPARATION a .e' 1 7/8" MIN. EDGE DISTANCE ° 1 1/4" MIN. EMBEDMENT d i 1/4" MAX. SHIM SPACE REV 1 1/4" MIN EMBEDMENT 1 7/8" MIN. v - EDGE DISTANCE ° 1/4" TAPCON a ca ° ° 4 7/16" v MIN e a SEPARATION ° NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, >`_v NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 v INTERIOR o 1/4" TAPCON ° ° ° c O CONCRETE/MASONRY o BY OTHERS o 1/4" TAPCON SILL TO BE SET IN A BED OF APPROVED SEALANT 1/4" MAX. L—JU I`UI r SHIM SPACE d a e' 'n < d, 1 1/4" MIN d d0 e ° EMBEDMENT Y ° a ° e. d ° 4 7/16" MIN 1 7/8" MIN SEPARATION EDGE DISTANCE VERTICAL CROSS SECTION CONCRETEIMASONRY INSTALLATION REVISIONS DESCRIPTION DATE 1/4" MAX. SHIM SPACE INTERIOR EXTERIOR APPROVED OPTIONAL 1X BUCK J BACKER ROD SEE NOTE 3 — 7 & APPROVED SHEET 1 SEALANT JAMB INSTALLATION DETAIL CONCRETE/MASONRY INSTALLATION SIGNED: 0611412017 MI WINDOWS650 WEST M RKE OORS STREET LLC `\\\J\S IR I IL O // GRATZ, PA 17030 v•v\GENS�,•'9cp'�� SERIES 120/130/140 ALUMINUM SLIDING ,61zl• GLASS DOOR — NON —IMPACT E •x 4 TRACK FLANGE INSTALLATION DETAILS �� . TAT O. ,. DRAWN: DWG NO. REV �'��•.'c�ORIOQ;• \��� SCALE GATE 08 s0E 087 — ��ssNA`1fp�G\\\\ NTS 04/18/17 22 OF 24 L. ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 FL No.: 62514 434-688-0609 rllomas@lrlomaspe.com 1 3/8" MIN. 1 MIN. EMBEDMENT EMBEDMENT WOOD FRAMING WOOD FRAMING OR 2X BUCK #14 WOOD OR 2X BUCK BY OTHERS SCREW BY OTHERS #14 WOOD SCREW 5/8" MIN. EDGE DISTANCE 5/8" MIN. EDGE DISTANCE HOOK STRIP HOOK STRIP 1 INTERIOR INTERIOR PANEL INTERLOCK PANEL INTERLOCK rvrr I,,I - I7v=0I/lO HOOK STRIP (M-2533) INSTALLATION 2X BUCKIWOOD FRAMING METAL STRUCTURE BY OTHERS #14 SELF DRILLING SCREW HOOK STRIP INTERIOR EXTERIOR 1 5/8" MIN. EDGE DISTANCE PANEL INTERLOCK HOOK STRIP (M-2533) INSTALLATION METAL STRUCTURE HOOK STRIP (M-2534) INSTALLATION 2X BUCK/WOOD FRAMING METAL STRUCTURE BY OTHERS #14 SELF DRILLING SCREW HOOK STRIP INTERIOR 5/8". MIN. EDGE DISTANCE PANEL INTERLOCK EXTERIOR HOOK STRIP (M-2534) INSTALLATION METAL STRUCTURE REVISIONS I REV I DESCRIPTION I DATE I APPROVED NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR — NON —IMPACT HOOK INSTALLATION DETAILS DRAWN: I DWG NO. A.R. 1 08-03087 SCALE NTS 1DATE 04/18/17 13HEE23 OF 24 L. ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE, NC 27023 434-633-0609 rllomasOalrlomaspe.com SIGNED: 0611412017 TAT2 OF REv %�'cFs.'c�OR10 /4 11��0�� Luis R. Lomas P.E. FL No.: 62514 1X BUCK BY OTHERS, 1X BUCK TO BE PROPERLY SECURED 1/4" TAPCON - HOOK STRIP INTERIOR EXTERIOR REV 1 1/4" MIN. 1 1/4" MIN. EMBEDMENT EMBEDMENT 1X BUCK BY OTHERS, a 1X BUCK TO BE G a. PROPERLY SECURED '<•< MASONRY/CONCRETE i MASONRY/CONCRETE 1/4" TAPCON '< e BY OTHERS BY OTHERS . e e 1 3/4" MIN. HOOK STRIP g EDGE DISTANCE 1 3/4• MIN. 1 a. EDGE DISTANCE INTERIOR F1 HOOK STRIP (M-2533) INSTALLATION MASONRY/CONCRETE m 3 1/2" _j 3 112" SILL EXTENDER ALUMINUM 6063-T5.062" THICK PANEL INTERLOCK EXTERIOR HOOK STRIP (M-2534) INSTALLATION MASONRY/CONCRETE r— 3/4" 2 518" SILL EXTENDER ALUMINUM 6063-T5.062" THICK REVISIONS DESCRIPTION MI WINDOWS AND DOORS LLC 650 WEST MARKET STREET GRATZ, PA 17030 SERIES 120/130/140 ALUMINUM SLIDING GLASS DOOR - NON -IMPACT SILL RISER DETAILS DRAWN: DWG NO. A.R. 1 08-03087 SCALE NTS JDATE 04/18/17 1 SHEET24 OF 24 L. ROBERTO LOMAS P.E. 143E WOODFORD RD LEWISVILLE, NC 27023 434-688-0609 rllomasgIrlomaspe.com DATE I APPROVED SIGNED: 0611412017 A�R IL s o:��///�i x Z /;/40NAL1Ea��`� Luis R. Lomas P.E. FL No.: 62514