Loading...
HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door AssembliesPtouIDA DepamM9rrt aP :. Business & Professional Regulation�11„L`rrrfzo 1 OBP0. NOaEa0Wr O0pP. OBF0.01V1910N9 10"IAVOR- Igc.nda y r*Product Approval l o ProdSER:uubllApp Product Anomval Menu > Application Detail MM FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence SHOP STAMP REVIEW Review is for general compliance with the Constructlon Documents. Responsibility for cortectness of dimensions, details, quantities and safety during fabrication Iles solely with the contractor. D4 No Exceptions Taken Reviewed By: Dawn Boggio-Korbelak F1-20461-R3 ❑ Rejected: Revision 2017 11/22/19 Warms'+ Approved Al Therma-Tru Corporation 118 Industrial Drive Edgerton, OH 43517 (419) 298-1740 rlckw@mbidgconsultants.com Vivian Wright rickw@mbldgconsultants.com Exterior Doors Swinging Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Lyndon F. Schmidt, P.E. PE-43409 National Accreditation and Management Institute 12/31/2021 Ryan J. King, P.E. [D Validation Checklist- Hardcopy Received FL2D461 R3 COT (d) Certificate of Indeoendenc%pdf Referenced Standard and Year (of Standard) Standard 101/I.5.2 ASTM E330 ASTM E331 TAS 202 Equivalence of Product Standards Certified By Sections from the Code Year 1997 2002 2000 1994 Product Approval Method Method 1 Option D Date Submitted 12/13/2017 Date Validated 12/13/2017 Date Pending FBC Approval 12/21/2017 Date Approved 02/13/2018 Date Revised 10/09/2018 Summary of Products Go to Page [—] 0 09Page I/200 FL # Model, Number or Name Description 20461.1 a. Therma-Tru Fiber -Classic and Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 11 (el Tnst 20461.I.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.1 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 20461.I.odf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes Particulars. (For Fiber -Classic and Smooth -Star doors, this Product approval requires the use of"7" part numbers for these doors, which have been stained or painted within six months of Installation. 20461.2 It. Therma-Tru Fiber -Classic and Nominal 5'8 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sldelite(s) (Inswing/Outswing; XO, OR or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 II (a) Inst 20461.2.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.2 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 20461 2.odf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of'0" part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.3 herma-Tm FlberClasslc and Nominal 6'B "Non -Impact" Opaque Fiberglass Composite Edge �cs-looth-Star Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 It (a) Inst 20461.3.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.3 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 20461.3.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of'0" part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.4 d. Therma-Tru Fiber -Classic and Smooth -Star Nominal 7'0 "Non -Impact" Opaque Composite Edge Fiberglass Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 11 (e) Tnst 20461.4.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.4 for Design Pressure Ratings, any FL20461 R3 AE W Eval 20461.4.odf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of"? part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.5 e. Therma-Tm Fiber -Classic and Nominal 7'0 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or ONO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL20461 R3 II (a) Inst 20461.5..odf Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.5 for Design Pressure Ratings, any FL20461 R3 AE (dJ Eval 2D4615 odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of "J" part numbers for these doom, which have been stained or painted within six months of Installation.) 20461.6 f. Therma-Tru Fiber -Classic and Nominal 8'0 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 II (e) Inst 20461.6.0f Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.6 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 20461.6.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of 7' part numbers for these doors, which have been stained or painted within six months of installation.) 20461.7 g. Therma-Tru Fiber -Classic and Nominal 8'0 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or ONO configurations) Limits of Use Installation Instructions Approved for use In HVHZ: No FL20461 R3 11 () Inst 20461 7 d Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.7 for Design Pressure Ratings, any FL20461 R3 AE (d) Eva] 204617 odf additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.8 h. Therma-Tm Fiber -Classic and Nominal 8'0 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ: No FL20461 R3 IT (a) Inst 20461.8.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.8 for Design Pressure Ratings, any FL20461 R3 AE (dJ Eval 20461.8.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of "T part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.9 I. Therma-Tru Fiber -Classic and Nominal 6'8 "NDn-Impact" Glazed Composite Edge Fiberglass Smooth -Star Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use In HVHZ: No FL20461 R3 II O Ins[ 20461 9 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.9 for Design Pressure Ratings, any FL20461 R3 AE M) Eval 204619 df additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber-Classlc and Smooth -Star doors, this product approval requires the use of "J" part numbers for these doors, which have been stained or painted within six months of installation.) 20461.10 J. Therma-Tru Fiber -Classic and Nominal 6'8 "Non -Impact" Glazed Composite Edge Fiberglass Smooth -Star Single Door with Sldelite(s) (Inswing/Outswing; XO, OX or ONO configurations) Limits of Use Installation Instructions Approved for use In HVHZ: No FL20461 R3 II (e) Inst 20461 10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.10 for Design Pressure Ratings, any FL20461 R3 AE (dJ Eval 20461 10 df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of'0" part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.11 k. Therma-Tru Fiber -Classic and Nominal 6'8 "Non -Impact" Glazed Composite Edge Fiberglass Smooth -Star Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 II (e) Inst 20461.11.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant; No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.11 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 20461.IS.odf additional use limitations, installation Instructions and product Created by Independent Third Party: Yes particulars. (For Flber-Classic and Smooth -Star doors, this product approval requires the use of"? part numbers for these doors, which have been stained or painted within six months of installation.) 20461.12 I. Therma-Tru Fiber -Classic and Nominal TO "Non -Impact" Glazed Composite Edge Fiberglass Smooth -Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 TI (e) Inst 20461.12.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.12 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 20461.12.odf additional use limitations, Installation Instructions and protluct Created by Intlependent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doom, this product approval. requires the use of"T' part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.13 m. Therma-Tru Fiber -Classic and Nominal TO "Non -Impact" Glazed Composite Edge Fiberglass Smooth -Star Single Door with Sidelite(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 II (e) Tnst 20461.13.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.13 for Design Pressure Ratings, any FL20461 R3 AE (dl Eval 20461.13.odf additional use limitations, Installation Instructions and product Created by Intlependent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this protluct approval requires the use of "1" part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.14 n. Therma-Tru Fiber -Classic and Smooth -Star Nominal B'D "Non -Impact" Glazed Composite Edge Fiberglass Single Door (Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved far use in HVHZ: No FL20461 R3 TT (e) Inst 20461.14.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.14 for Design Pressure Ratings, any FI 20461 R3 AE (d) Eval 20461.14.odF additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of "T' part numbers for these doom, which have been stained or painted within six months of installation.) 20461.15 0. Therma-Tru Fiber -Classic and Nominal 8'0 "Non -Impact" Glazed Composite Edge Fiberglass Smooth -Star Single Door with Sldellte(s) (Inswing/Outswing; XO, OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No FL20461 R3 11 (e) Inst 20461 15.odf Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.15 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 2046115 od additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this protluct approval requires the use of"? part numbers for these doors, which have been stained or painted within six months of installation.) 20461.16 p. Therma-Tru Fiber -Classic and SmoDth-Star Nominal 8'0 "Non -Impact" Glazed Composite Edge Fiberglass Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO confguratons) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 IT (a) Inst 20461 16 odf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Intlependent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.16 for Design Pressure Ratings, any FI 20461 R3 AE (d) Eval 20461.16.odf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. (Far Fiber -Classic and Smooth -Star doors, this Product approval requires the use of'7" part numbers for these doors, which have been stained or painted within six months of installation.) 20461.17 q. Therma-Tru Fiber -Classic and Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Doorwith Transom (Inswing/Outswing; DIX configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 11 () Inst 20461 17 odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 20461.17 for Design Pressure Ratings, any FL20461 R3 AE (it) Eval20461 17 oilf additional use limitations, Installation instructions and product Created by Independent Third Party: Yes particulars. (For Flber-Classic and Smooth -Star doors, this product approval requires the use of'7" part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.16 r. Thera— Fiber -Classic and Nominal 5'8 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sldellte(s) and Transom (Inswing/Outswing; 0/XO, 0/OX or O/OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 II (e) Inst 20461.IB.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 20461.18 for Design Pressure Ratings, any FL20461 R3 AE (d) Eval 20461.18.0f additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of "P' part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.19 s. Therma-Tru Fiber -Classic and Nominal 6'8 "Non -Impact" Opaque Composite Edge Fiberglass Smooth -Star Single Door with Sldelite(s) (Inswing/Outswing; XO, OX or OXO Continuous Head and SIII configurations) Limps of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 11 () Inst 20461 19 df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 20461.19 for Design Pressure Ratings, any FLZD461 R3 AE (dl E al 20461 19 df additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of "3" part numbers for these doors, which have been stained or painted within six months of Installation.) 20461.20 herma-Tru Fiber -Classic and Nominal BIT "Non -Impact" Opaque Composite Edge Fiberglass ooth-Star IIS Single Door with Sldelitii (Inswing/Outswing; XO, OX or ONO Continuous Head and SIII configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL20461 R3 If (e) Inst 20461.20.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 20461.20 for Design Pressure Ratings, any FL20461 R3 AE (d1 E al 20461 20 df additional use limitations, Installation Instructions and product Created by Independent Third Party: Yes particulars. (For Fiber -Classic and Smooth -Star doors, this product approval requires the use of "Y' part numbers for these doors, which have been stained or painted within six months of installation.) Go to Page = 0 Back Next ®QPage l/2040 Contact Us :: 2601 Blo, Stone Road Tallahassee EL 32399 phone650-0117-1824 The Scale of Florltla is as WEEO employd, raovr oM1t 2002-2013 State of Florida.:: Prlvacv Statement:: AecuAblifty 5tamemen:: Refund Sturm¢ Under Florltla law, email addresses are public recces. If you do not want your e-mail address released in response to a public -records request, do not send elecimnlc mall t4 this emlty. Instead, contact the mace by phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to section 4S5.325(1), Florltla Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The ¢malls provided may be used or official communlration with the seamen. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available N the public. To determine if you are a licensee under Chapter 455, F.S., please dick here . Product Approval Accepts: ®O ®ERM Credit Card Safe R W R W Building Consultants, Inc. B Consulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Swinging Therma-Tru Corporation Fiber -Classic and Smooth-Star Exterior Exterior Door 118 Industrial Dr Composite Edge Opaque Fiberglass Single Door Doors Assemblies Edgerton, OH 43617 Inswing I outswing_ Phone 419-298-1740 "Non -Impact" Scope: Product Evaluation report issued by R W Building Consultants, Inc. & Lyndon F. Schmidt, P.E. (System ID # 1998) for Therma-Tru Corporations, based on Rule Chapter No. 61G20-3, Method 1D of the State of Florida Product Approval, Dept of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity Involved In the approval process of the product named herein. Umltatfons: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. For 2x stud'framing construction. anchoring of these units shall be the same as that shown for 2x buck masonry construction. 4. Site conditions that deviate from the details of drawing FL-20461.1 require further engineering analysis by a licensed engineer or registered architect. 5. Fiber -Classic & Smooth -Star Door panels require the use of "J" part numbers and must be stained or painted within six months of Installation 6. See drawing FL-20461.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL01460145 TEL01461573 2. Drawinq No. No. FL-20461.1 3. Calculations Anchoring Test Standard ASTM E330(02), ASTM E331(00) ASTM E330-02 & ASTM E331-00 Prepared by RW Building Consultants, Inc. (CA#9813) Prepared by RW Building Consultants, Inc. (CA 99813) 4. Quality Assurance Certificate of Participation issued by National Accreditation & Management Institute, certifying that Therma-Tru Corporations is manufacturing products within a quality assurance program that complies with ISOAEC 17020.and .Guide 53. SHOPSTAMPREVIEW Wta/Plan Review Is for general compliance with the Construction Documents. Res onsibilhy for correctness of dimensions, details, quantities and safety durPng fabrication lies solely with the contractor. It NoUreptionsTaken Reviewed By: Dawn Boggio-Korbelak 0 Rejected: 11 /22/19 dla,�, $. Kerf,(g& L. Sheet 1 of 1 Testing Laboratory Signed by Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lnc. V.K. Wright Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed by Lyndon'F. Schmidt, P.E. Lyndon F. Schmidt, P.E. FL PE No. 43409 12f/1'2017 Florida Building Code Online Page 1 of 6 ONE r� BCIS Home LoB to i User Regklmtlon Hot Tables Submit 5urcle,le State &F.. I Publications I eontatt us i 6ele Site Map Units) search i Fndd` Product Approval SHOP STAMP REVIEW hip/plan Lelia USER: Public Uses Review isfor genercompliance With the Documents. x � dimensions, details, Responsibility for correctnesssolely With thcotadetails, quantities and safety during fabrication Iles solely with the contractor. Product Anma¢xl Heru> Product or Anoaranon Search> Aonncston ust> ApVnratlen Pet 1111 No Exceptions Taken Reviewed By: Dawn BDggio-KOrbelak FL FL36546-Ril ❑ Rejected: Application Type Code Version Revision 2017 11/22/19 0ai KmbdAL Application Status Approved Comments Archived ❑ Product Manufacturer Clopay Building Products Company Address/Phone/Email 8585 Duke Blvd. Mason, OH 45040 (513) 770-6062 mwesterfleid@clopay. com Authorized Signature Scott Hamilton shamilton@clopay.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Scott Hamilton the Evaluation Report Florida License PE-63286 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By Gary Pfuehler U Validation Checklist - Hardcopy Received Certificate of Independence FL16 46 R11 COI Certification of Independence of Validation Entity - Gary Pfuehler 2016-02-49 2 FL16546 RIICOI tatement on Independence of Evaluation nti - ScottHamiltun 2016-02-19.odf Referenced Standard and year (of Standard) Standard Year ANSI/DASMA 108 2005 ANSI/DASMA 115 2005 ASTM E1886 2005 ASTM E1996 2009 ASTM E330 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2wP/`2bnFgU... 10/23/2019 Florida Building Code Online Page 2 of 6 Sections from the Cade Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page O 0 FL16546 Rll Eaulv 20170809 - FBC - DASMA 100 eauiv.odf FL16546 1131 Eauiv 70170809 - FBC - DASMA 115 eouiv.ndf Method 1 Option D 12/18/2018 02/13/2019 02/13/2019 04/16/2019 0 0 Page l/40 0 FIL Yf Model, Number or Name Description 16546.1 01 W5-16-HY PAN-2F153/6: 73, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 1500, 75, 76, 190, 84A, 94, 42, WINDCODE® W5 Garage Door 42B, 48, 48B, 55, 4F, 4RST, 6RST, 4RSF, 6RSF, GDSS, GD5SV, GRSS, GR5SV, ARSS, ARSSV, EDSS, EDSSV Limits of Use Installation Instructions Approved for use In HVHZ: No FL16546 R11 IT 101922-6-Revl5.odf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Parry: No Design Pressure: +32 PSF/-32 PSF Evaluation Reports Other: Solid doors (no glazing) or doors with optional FL16546 R31 AE CBPC 131211-A.odf impact -resistant glazing are Impact -resistant (large missile Created by Independent Third Party: No Impact). 16546.2 02 WS-16-HY PAN-2F153/6: 73, Steel Pan (min. 25 ga.) Double -Car (97'to 16'0" wide) 1500, 75, 76, 190, B4A, 94, 42, WINDCODE® W5 Garage Door 42B, 48, 48B, 55, 4F, 4RST, 6RST, 4RSF, 6RSF, GDSS, GD5SV, GRSS, GRSSV, ARSS, ARSSV, EDSS, EDSSV Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL16546 RSS 11 101922-13-Revl5.odf Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +32 PSF/-32 PSF Evaluation Reports Other: The standard glazing available for this product meets FL16546 R11 AE CBPC 131211-6adf the wind load requirements of the building code but DOES Created by Independent Third Party: No NOT meet the Impact resistant requirement for windborne debris regions. 16546.3 03 WS-16 PAN-21`443: GD4S, GR4S, Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Double- ED4S, AR4S Car (9'2" to 16'2" wide) WINDCODE® WS Garage Door with Optional Impact -Resistant Lites Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16546 R11 II 104791-RevO$ odf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +46 PSF/-52 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no F1I6546 RSI AE CBPC 131211-A.odf glazing) or doors with optional Impact -resistant glazing are Created by Independent Third Party: No Inn - sistant (large missileimpact). 16546.4 04 W6-16 PAN-21F353: 73, 1500, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'2" wide) 75, 190, 84A, 94, 42, 42B, 48, 48B, WINDCODE@ W6 Garage Door with Optional Impact- 55, 4RST, 6RST, 4RSF, 6RSF, GDSS, Resistant Lites GD5SV, GRSS, GR5SV, ARSS, ARSSV, ED5S, EDSSV Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16546 1111 II 104710-A-Rev03 odf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +36 PSF/-42 PSF Evaluation Reports Other: Max. Wind Speed (V_uit): 170 MPH. Solid doors (no FL16546 R11 AE CBPC 131211-A odf standard glazing) are Impact -resistant (large missile impact). Created by Independent Third Party: No 16546.5 https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgU... 10./23/2019 Florida Building Code Online Page 3 of 6 05 W6-16 PAN-2F153: 73, 1500, Steel Pan (min. 25 ga.) Double -Car (92" to 16'2" wide) 75, 190, 84A, 94, 42, 4B, 55, 4RST, WINDCODE® W6 Garage Door '611ST, 4RSF, 6RSF, GOES, GD5SV, GRES, GR5SV, ARSS, AR5SV, ED5S, ` ED5SV Limits of Use Installation Instructions Approved for use in HVHZ: No FI16546 RIt II 104710-8-Rev03.ndf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +36 PSF/-42 PSF Evaluation Reports Other: The standard glazing available for this product meets FL16546 R11 AE CBPC 131211-A odf the wind lead requirements of the building code but DOES Created by Independent Third Party: No NOT meet the Impact resistant requirement for windborne debris regions. 16546.6 06 W6-16 PAN-2F156: 76, 211ST Steel Pan (min. 25 ga.) Double -Car (92" to 16'2" w ode) WINDCODE® WE Garage Door Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL16546 R11 II 104710-A-Ry03 odf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +36 PSF/-42 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no standard glazing) are impact -resistant (large missile Impact). FL16546 R11 AE CBPC 131211-A.odf Created by Independent Third Party: No 16546.7 07 W6-16 PAN-2F156: 76, 2RST Steel Pan (min. 25 ga.) Double -Car (92" to 162" wide) WINDCODE® W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 RII 11 104710-8-RevO3,pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +36 PSF/-42 PSF Evaluation Reports Other: The standard glazing available for this product meets FL16546 RII AE CBPC 131211-A odf the wind load requirements of the building code but DOES Created by Independent Third Party: No NOT meet the Impact resistant requirement for windborne debris regions. 16546.8 08 WS-16 PANSP-21`153/6: 73SP, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 15SP, GDSSSP, GD5SSPV, 76SP, WINDCODE(D WS Garage Door 76VSP Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 RII II 104818-A-ftev0l-sI ned.odf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +32 PSF/-37 PSF Evaluation Reports Other: Solid doors (no glazing) or doors with optional FL16546 RII AE CBPC 131211-A odf Impact -resistant glazing are Impact -resistant (large missile Created by Independent Third Party: No Impact). 16546.9 09 W5-16 PANSP-2F153/6: 73SP, Steel Pan (min. 25 ga.) Double -Car (9'2" to 16'0" wide) 15SP, GD5SSP, GD5SSPV, 76SP, WINOCODEB WS Garage Door 76VSP Limits of Use Installation Instructions Approved for use in HVHZ: No FL16546 R31 II 104818-11-Revu-signed.odf „ Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No ' Design Pressure: +32 PSF/-37 PSF Evaluation Reports Other: The standard glazing available for this product meets FL16546 R11 AE CBPC 131211-A odf „ the wind load requirements of the building code but DOES Created by Independent Third Party: No NOT meet the Impact resistant requirement for windborne debris regions. 16546.10 10 W6-09 DSIE-IA171: 2050, 2051, Double -skin Insulated EPS (exterior skin 27 ga. min.; Interior 2053, 4050, 4051, 4053, 62, 64, skin 29 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® 65, 62G, 62LG, 64G, SDP38, SFL38, W6 Garage Door SRP3B, 134, 135, 136, 6130, 6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16546 R31 U 104814-A-ReV60.Ddf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +36 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no F1.16546 R11 AF CBPC 131211-A.odf glazing) are impact-resistant(large missile Impact). Created by Independent Third Party: No 16546.11 11 W6-09 DSIE-1A171: 2050, 2051, Double -skin Insulated EPS (exterior skin 27 ga. min.; Interior 2g53, 4050, 4051, 4053, 62, 64, skin 29 ga. min.) Single -car (up to 9'0" wide) WINOCODE® 65, 62G, 62LG, 64G, SDP38, SFL3B, W6 Garage Door SRP38, 134, 135, 136, 6130, 6131, 6133 https://floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgU... 10/23/2019