HomeMy WebLinkAboutRevison; Product Approvals for Windows, SGD, Vinyl Soffit & Driveway + Sidewalk detailsOFFICE USE ONLY:
(ltDATE FILED:
REVISION FEE: _
I
PERMIT # 19 12. - 0o9 93
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652
(772)462.1553
APPLICATIONFOR
INFORMATION PERMIT REVISIONS
PROJECT co?,
LOCATION/SITE
ADDRESS: REVISION
LOTLOT#�S'�i�ARMINA PLACEPLACE j�L
FORT PIERCE, FLORIDA, 34951
DETAILED DESCRIPTION OF PROJECT l�
REVISIONS: J N,qr `i"
Revised Product Approvals for windows, SGD, and vinyl soffit d—riw
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CBC1263043
BUSINESS NAME: K. HOVNANIAN FLORIDA OPERATIONS, LLC
QUALIFIERS NAME: JOSEPH C SPALT
ADDRESS: 3601 QUANTUM BLVD
CITY: BOYNTON BEACH STATE: FL
PHONE (DAYTIME): 561-364-3316
OWNER/BUILDER INFORMATION:
NAME: K. HOVNANIAN ASPIRE AT WATERSTONE
ST. LUCIE CO CERT. #: 31426
I
ADDRESS: 3601 QUANTUM BLVD
CITY: BOYNTON BEACH STATE: FL
PHONE (DAYTIME: 561-364-3316 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: DAWN BOGGIO KORBELAK
ADDRESS: 90 MATAWAN RD, 5TH FLOOR
CITY: MATAWAN,
PHONE (DAYTIME): 732-747a600
SLCCC: 9123109
Revised 06130117
STATE: NJ
17:W"fi
ZIP: 33426
ZIP: 33426
ZIP: 07747
FORM R405-2017
r--IORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
~Florida Department of Business and Professional Regulation - Residential Performance Method
/J
Project Name: WATERSTONE LOT-4
Builder Name: K. Hovanian
Street: TBD
Permit Office: St. Lucie County
City, State, Zip: FT. PIERCE , FL. 34951
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1786.8 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1464.70 ft'
b. Frame - Wood, Adjacent
R=11.0 322.11 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft,
10. Ceiling Types (1917.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1917.00 ft2
6. Conditioned floor area above grade (ft') 1917
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft'
7. Windows(193.8 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 548
a. U-Factor. Dbl, U=0.32 131.11 ft'
SHGC: SHGC=0.30
b. U-Factor. Dbl, U=0.55 41.00 W
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.34
a. Central Unit
40.0 SEER:14.00
c. U-Factor: Dbl, U=0.32 21.67 ft2
SHGC: SHGC=0.27
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: NIA ft2
a. Electric Heat Pump
34.0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 1.339 ft.
Area Weighted Average SHGC: 0.305
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1917.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 1917.00 ft'
b. Conservation features
b. NIA R= ft2
None
c. NIA R= ft2
15. Credits
Patel
Glass/Floor Area: 0.101 Total Proposed Modified Loads: 59.43
PASS
Total Baseline Loads: 62.97
1 hereby certify that the plans and specifications covered by
Review of the plans and
FSHE ST-
this calculation are in compliance with the Florida Energy
specifications covered by this
indicates
4V0
Code.
calculation compliance
with the Florida Energy Code.
y��,,, :s;',,•"
F mn . r'•`,:.•�°„ 0�
,.
PREPARED BY:
Before construction is completed
riii�ttL
DATE: 4/21/2020
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, designed, is in compliance
Florida Statutes.
!,),
with the Florid d
CAD W9E'�O
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
VISION ®p"Y
4/21/2020 12:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant VkAe f Pagel of 4
F:nRM R4f15-9017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
WATERSTONE LOT-4
User
1
K. Hovanian
St. Lucie County
Single-family
New (From Plans)
Bedrooms: 4
Conditioned Area: 1917
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: TBD
County: St. Lucie
City, State, Zip: FT. PIERCE,
FL, 34951
CLIMATE
/
V/ Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL,
Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
1917 16486.2.
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfI ID Finished Cooled Heated
1
Main
1917 16486.2 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 169 ft
1917 ft'
---- 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 2076 W 0 ft2 Medium
N
0.4 N 0.9 No 0 22.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1917 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type 71
1
Under Attic (Vented)
Main 30 Blown
1917 ft2 0.1 Wood
4/21/2020 12:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar Below
Space
_ 1
N
Exterior Concrete Block - Ext Insul Main
4.1 49 2 8
8
426.1 ft2
0
0 0.3
0
-2
W
Exterior Concrete Block - Ext Insul Main
4.1 16 10 8
8
145.9 W
0
0 0.3
0
3
S
Exterior Concrete Block - Ext Insul Main
4.1 68 0 8
8
589.3 ft2
0
0 0.3
0
4
E
Exterior Concrete Block - Ext Insul Main
4.1 35 - 0 8
8
303.3 ft2
0
0 0.3
0
5
-
Garage Frame - Wood Main
11 37 2 8
8
322.1 ft2
0
0.25 0.3
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W Wood Main
None
.39
3
6 8
20 ft
2
S Wood Main
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1 Vinyl Double (Clear) Yes
0.32 0.3 N
15.0 ft2
1 ft 0 in
1 It 0 In
None
None
2
N 1 Vinyl Double (Clear) Yes
0.32 0.3 N
16.4 ft2
1 ft 0 in
1 ft 0 in
None
None
3
W 2 Vinyl Double (Clear) Yes
0.32 0.27 N
21.7 ft-
1 ft 0-in
1 ft 0 in
None
None
4
S 3 Vinyl Double (Clear) Yes
0.32 0.3 N
21.7 ft2
1 ft 0 in
1 It 0 in
None
None
5
S 3 Vinyl Double (Clear) Yes
0.32 0.3 N
15.0 ft2
1 ft 0 in
1 ft 0 In
None
None
6
S 3 Vinyl Double (Clear) Yes
0.32 0.3 N
16.4 ft2
5 It 0 in
1 ft 0 in
None
None
7
E 4 Vinyl Double (Clear) Yes
0.32 0.3 N
21.7 ft2
1 ft 0 in
1 ft 0 in
None
None
8
E 4 Vinyl Double (Clear) Yes
0.32 0.3 N
24.9 ft2
1 ft 0 in
1 It 0 In
None
None
9
E 4 Vinyl Double (Clear) Yes
0.55 0.34 N
41.0 ft2
1 ft 0 in
1 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft2 380 ft2
64 It
8.6 ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000383
1923.4 105.59 198.58
.1364
7
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
HSPF:9
34 kBtu/hr
1
sys#1
4/21/2020 12:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 14
40 kBtu/hr
cfm
0.7
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Carl # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
k'
DUCTS
---Supply—
---Return----
Air
CFM 25 CFM25
HVAC#
# Location R-Value
Area
Location
Area Leakage Type
Handler
TOT OUT
ON
RLF
Heal Cool
1 Attic
6 548 W
Attic
262 ft- Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programablre,Thermostat:
Ceiling Fans:
,JY
Heating Jan Feb
r[
[X� Mar
r[`
MayJun Jul
1
r[` ]J
JXJ Aug
r[`
Sep
Oct
rDO,
Nov
Dec
IrX,t
Dec
Venting L 1 Jan L 1 Feb
L 1 L 1
lLX Mar
Apr [
May L 1 Jun L Jul
lXj
( Aug
L Sep
LX�
[X]
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
76 78 78
78
78 78
78
78
78
PM
78
78 78
78 78 78
78
78 78
78
78
78
Heating(WD) AM
66
66 66
66 66 68
68
68 68
68
68
66
PM
68
68 68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68 68
68
68
68
PM
68
68 68
68 68- 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft,
0 ft
0.3
Main
4/21/2020 12:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
40.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1917
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.369
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.305
c) Area 7c. 193.8
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
14. Heating system: Capacity 34.0
a) Split system heat pump HSPF 9.0
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
10131. 11.0
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a. 30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11 c.
d) Multizone cooling credit
11 d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature Date: �[�yllao'io
Address of New Home: M9DIgAyV City/FL Zip: FT. PIERCE, FL 34951
4/21/2020 12:48:48 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: TBD Permit Number:
FT. PIERCE, FL, 34951
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and cored before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelffilia building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 Inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the Intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdratt and Flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Fj R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air IeakagdNindows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square fool (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/ni when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
4/21/2020 12:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
"❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated In accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heal pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i),.Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1, Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if Installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturers air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the lest and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping Insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41°C)
or below 55"F (13"C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory)Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
4/21/2020 12:48 PM EnergyGaugeD USA 6.0.02 (Rev. 1) - Flaftes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heal traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 Y inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 1407 (38'C to 60`C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -healing systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment Installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFMMATT-)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/walt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/wall
<90
Bathroom, utility room
90
2.8 cfm/wall
Any
For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916
4/21/2020 12:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturers product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -lest value and shall not be used for equipment sizing. Manufacturers
expanded performance data shall be used to select cooling -only equipment. This selection shall be based an the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
El shall
Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and Ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall Include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10*% and no
precipitation Is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
Integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heal -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
healers fired by natural or LP gas shall not have continuously burning pilot lights.
4/21/2020 12:48 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatory},e energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights.
4/21/2020 12:48 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WATERSTONE LOT-4 Builder Name: K. Hovanian
Street: TBD Permit Office: St. Lucie County
City, State, Zip: FT. PIERCE, FL, 34951 Permit Number:
Y
U
Owner: Jurisdiction:
w
x
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
•
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped,
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind ninono an wir no
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
I
exteriorwalls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover Hates and walls or ce lines.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/21/2020 12:48 PM EnergyGauge a0 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction:
Permit #:
Job'Jnformationl
Builder: K. Hovanian Community: Lot: NA
Address: TBD
City: FT. PIERCE State: FL Zip: 34951
Air, ;Leakage Test Results Passing results must -meet either,the Perfprmance;'Prescriptive, or`ERIMethod
O, :PRESCRIPTIVE METHOD -The building�ordwellingeunit+shall be tested andwerified as having,an;air leakage rate of=not exceeding 7.air
I changes per hour at,a,pressure,of,0.2 inchm.g. (50)Pascals)vn Climate, Zones 1 and:1
0: PERFORMANCE,or ERI METHOD-The,buildingcor dwellingfunh shalllbe tested and'Nerified as,naving an airlleakage rate=oflnot exceeding,.
',the selected ACH(50),,value as shown on Form;R405 201�7 (Pe%forman.m) or, R406-2017.(ERI), section:labeled asj.infltration sub -section ACH50.
ACH(50) sp'ecffled on Form R405 2017'Energy Calc (Perfdrmance)For R406-20h7:(ERI): 7.000 I
x 60 _ 16486 — Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(1), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal, envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
TestingnCompahy "
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
4/21/2020 12:49:06 PM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FSC 6th Edition (2017) Compliant Software Page 1 of 1
DO NOT SCALE PLANS
1ALL BE WITHIN 3 FEET
"ALLY OF MAIN RETURN
on
Now
�m
. HOVNANIAN
WATE K5TO N E LOT-04
AYMINA PLACE
FONT FIEKCE, FL 34982
I
4/24/2020 Florida Buildin
Business & Professional Regulation
BCIS Home I Log In I user Registration I Hot Topla I Submit Surcharge I
SHOP STAMP REVIEW
Review Is for general compliance with the Construction Documents.
Responsibility for correctness of dimensions, details, quantities and safety
during fabrication lies solely with the contractor.
D4 No Exceptions Taken Reviewed By: Dawn Boggio-Korbelak
❑ Rejected:
d Florida�� 4/28120
1 er Product Approval
y USER: Public User
u^ .
Product Approval Menu > Prodvd or Aooliraj;k L Search > Apo@atlon Lis[ > APPllcetlon Detall
FL #
FL35332-R5
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived 0
Product Manufacturer MI Windows and Doors
Address/Phone/Email 650 West Market Street
Gratz, PA 17030
(717) 365-3300 Ext 2560
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sliding Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
d Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Luis Roberto Lomas
Evaluation Report
Florida License
PE-62514
Quality Assurance Entity
American Architectural Manufacturers Association
Quality Assurance Contract Expiration Date
12 31 2020
Validated By
Steven M. Urich, PE
u Validation Checklist - Hardcopy Received
Certificate of Independence
FL35332 R5 COT FLCOI.PA
Referenced Standard and Year (of Standard)
Standard Year
AAMA/WDMA/CSA 101/I.S.2/A440 2008
Equivalence of Product Standards
Certified By
Sections from the Code F,V,e co
/ `� VigON
Product Approval Method Method 1 Option D
https:IAd .tioridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQvADgtH8572gvdWldku3BmvbCOTyMW9wxhwpTl FkhOfDHBW5wp/o3dp/o3d 1/4
4/24/2020
Florida Building Code Online
Date Submitted 06/18/2019
Date Validated 06/19/2019
Date Pending FBC Approval 06/24/2019
Date Approved 08/13/2019
SummarV of Products
FL #
Model, Number or Name
Description
15332.1
SERIES 420 ALUMINUM SGD
SERIES 420 ALUMINUM SGD OXO 145-3/4"x80" NON -
REINFORCED
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLIS332 RS 11 08-00500E.P f
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
FLIS332 RS AE 510807D,Pdf
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332t2
iSERIES,420,ALUMINUM. SGD)``SERIES
420. ALUMINUM SGD OX XO, XX 96"x80"'NON -
9EINFORCED
Limits of Use
fIastallation:Instructions
Approved far se in HVHZ: No
IFL153: RS Il 08-00498E.pd�
IApproved for use outside HVHZ: Yes
{Venfled,By: Luis Roberto Lomas$2514
((IImpact Resistant: No?jCreated
by Independent Third -Party: Yes
fDesign Pressure: N/A
Other: REFER T APPROVAL, DOCUMENT MIR DESIGN
RESSURE RATINGS
`Evaluation Reportsl�—
IFL15332 R5 AE 510805D. I
Created b Independent Tfiird'Party: Yes
15332.3
SERIES 420 ALUMINUM SGD
SERIES 420 ALUMINUM SGD REINFORCED OXO 145-3/4"x96"
REINFORCED
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLIS332 RS II 08-02248C.pdf
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
FL15332 RS AE 512968C.Pff
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332.4
SERIES 420 ALUMINUM SGD
SERIES 420 ALUMINUM SGD REINFORCED OX, XO, XX 96"x96"
REINFORCED
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLIS332 R5 II 08-02249C.p,df
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
FL15332 R5 AE 512969C.odf
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332.5
SERIES 420 ALUMINUM SGD
SERIES 420 ALUMINUM SGD REINFORCED XXX 143"x96"
REINFORCED
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL15332 R5 11 08-02250C.pdf
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
FLIS332 RS AE 512970Cpdf
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332.6
Series 420 OXXX SGD Reinforced
Series 420 OXXX SGD Reinforced non Impact (Interior
Reinforcement)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL15332 R5 11 FL16054 R6 11 08-01830D ndf
Approved for use outside HVHZ: Yes
Verified By: Luis R. Lomas, PE PE-62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to approval document for design pressure
FL15332 R5 AE FL16054 R6 AE 512517D.odF
ratings.
Created by Independent Third Party: Yes
15332.7
Series 420 OXXX SGD Reinforced
Series 420 OXXX SGD Reinforced Non Impact (Interior and
Exterior Reinforcement)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLIS332 R5 II FL16054 R6 II 08-01831D.odf
Approved for use outside HVHZ: Yes
Verified By: Luis R Lomas, PE PE-62514
Impact Resistant: No
Created by Independent Third Party: Yes
Evaluation Reports
https:/Avww.floridabuilding.org/pr/pr_app_dti.aspx?pamm=wGEVXQWtDgtHB572gvdWldku3BmvbCOTyMW9wxhwpTl FkhOfDHBW5w%3d%3d 214
4/24/2020
Florida Building Code Online
Design Pressure: N/A
FLI5332 RS AE FL16054 R6 AE 5125180.gd(
Other: Refer to approval document for design pressure ratings
Created by Independent Third Party: Yes
15332.8
SERIES 420 REINFORCED ALUMINUM
SERIES 420 REINFORCED ALUMINUM SGD OXO 146"x96'
SGD
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLI5332 RS If 08-00501E.12df
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
F1,15332 IS AE 5108081).gpf
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332.9
SERIES 420 REINFORCED ALUMINUM
SERIES 420 REINFORCED ALUMINUM SGD OX, XO, XX 96"x96'
SGD
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLI5332 RS If 08-00499E.gdf
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
FL15332 RS AE 510806D.odf
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332.10
SERIES 430/440 ALUMINUM SGD
SERIES 430/440 ALUMINUM SGD XXX 14TWO" NON -
REINFORCED
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLI5332 RS II 08-00502E.pdf
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
FLI5332 R5 AE 510809D.odf
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332.11
SERIES 430/440 REINFORCED
SERIES 430/440 REINFORCED ALUMINUM SGD XXX 143"x96"
ALUMINUM SGD
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLI5332 RS II 08-00503E.p-df
Approved for use outside HVHZ: Yes
Verified By: Luis Roberto Lomas 62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: REFER TO APPROVAL DOCUMENT FOR DESIGN
FLIS332 RS AE 510810D.odf
PRESSURE RATINGS
Created by Independent Third Party: Yes
15332.12
Series 440 OXXX SGD Reinforced
Series 440 OXXX SGD Reinforced Non Impact (Interior and
Exterior Reinforcement)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLI5332 RS II FL16054 R6 II O11-01885D.gQ[
Approved for use outside HVHZ: Yes
Verified By: Luis R. Lomas, PE PE-62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to approval document for design pressure ratings
FLI5332 R5 AE FL16054 R6 AE 512577D.gdf
Created by Independent Third Party: Yes
15332.13
Series 440 OXXX SGD Reinforced
Series 440 OXXX SGD Reinforced Non Impact (Interior
Reinforcement)
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FLI5332 IS 11 FL16054 R6 II 08-01886D.adf
Approved for use outside HVHZ: Yes
Verified By: Luis R. Lomas, PE PE-62514
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to approval document for design pressure ratings
FLI5332 R5 AE FL16054 R6 AE 512578D.12df
Created by Independent Third Party: Yes
Back Next
Conte:: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 650-482-1824
The state of Florida is an AA/EW employer. CMmiht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to [ills entity. instead, contact the office by phone or by traditional mall. if you have any questions, please corm ut 850.487.1395.'Pumuant to Section 455.225(1),
Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must moulds the Department with an email address if they have one. The smalls
provided may be used for official communlration with We licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, F.S., please click bs .
Produce Approval Accepts:
® ® ® K®— M
https:lAwm.floridabuilding.org/prlpr app_dtl.aspx7param=wGEVXQwtDqtHB572gvdWldku3BmvbCOTyMW9wxhwpTl FkhOfDHBW5w%3d%3d 314
4/24/2020
Florida Building Code Online
Credit Card
Safe
https://www.floddabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgtH8572gvdWldku3BmvbCOTyMWgwxhwpTIFkhOfDHBW5w%3d%3d 4/4
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville, NC 27023
434-688-0609
rllomm@lrlomwpe.com
lrlomwpe.com
Manufacturer: MI Windows and Doors LLC
650 West Market Street
Gratz, PA 17030
Product Line: Series 420 Aluminum SGD 96"x80 Non -Reinforced
Engineering Evaluation Report
Report No.: 510805D
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(d). The product listed
herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval document: drawing number 08-00498, Revision E, prepared, signed and sealed by Luis Roberto Lomas
P.E.
2. Report No.: CCLI-12-119 signed by Wesley Wilson
Construction Consulting Laboratory International, Carrollton, TX
AAMA/WDMA/CSA 101/I.S.2/A440-08
Design pressure: t40.Opsf
Water penetration resistance 6.Opsf
3. Anchor calculations, report number 510805-1 C and 510805-2, prepared, signed and sealed by Luis Roberto Lomas
P.E.
Limitations and Conditions of use;
• Maximum design pressure: Refer to approval document.
• Maximum panel size: 48 %" x 79"
• Approved configurations: OX, XO, XX, XP, PX, XIP and PIX
• Units must be glazed per ASTM E1300-04/09, with safety glazing.
• This product is not rated to be used in the HVHZ.
• This product is not impact resistant and requires impact protection in wind bome debris regions.
• Frame material to be aluminum 6063-T5.
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval document, 08-00498,
Revision E.
Certification of Independence:
Please note that I don't have norwill acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
1 of 1
th���ii
NJ\c? • • ;tl y �i�
'* o 51 •*=
TAT E OF ; w�
%�.c�.�`�pR10P•
Z,S��NALt��G\N
Luis R. Lomas, P.E.
FL No.: 62514
06/20/2017
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1X BUCK IS NOT USED
DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE.
SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR
ENGINEER OF RECORD.
4. ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT
SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR
CALCULATIONS.
5. FRAME MATERIAL: EXTRUDED ALUMINUM 6D63—T5.
S. UNITS MUST BE GLAZED PER ASTM E1300-04/09, WITH SAFETY GLASS.
7. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE
DEBRIS REGIONS.
B. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE
SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. DOOR ASSEMBLIES INSTALLED WHERE OVERHANG RATIO IS EQUAL OR GREATER THAN 1.0 DO
NOT REQUIRE WATER INFILTRATION RESISTANCE.
OVERHANG RATIO = OVERHANG LENGTH/OVERHANG HEIGHT
10. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
11. FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH
TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE
DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
12, FOR ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS WITH
SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
13. ALL FASTENERS TO BE CORROSION RESISTANT.
14. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI.
C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER).
D. METAL STRUCTURE: STEEL 18GA, 33KSI OR ALUMINUM 6063—T5 .048" THICK MINIMUM
15. APPROVED CONFIGURATIONS: OX, XO, XX, XP, PX, XIP, PIX.
TABLE OF CONTENTS
HEFT NO. DESCRIPTION
1 NOTES
2 — 3 ELEVATIONS
4 — 10 INSTALLATION DETAILS
RLYSIDNS
RW
Dms'.DN
Mn
r PR .
A
ADDED CHARTS
03/05/12
R.L
B
REVISED PER NEW TESTING
10/29/13
R.L
C
ADDED R-ANGE AND RN INSTALLATIONS
12/06/13
R.L
D
REVISED INSTAUATIDN DETAILS
07/30/15
R.L
E
REVISED INSTALLATION DETAILS
06/20/17
R.L
SIGNED: 0612012017
MI WINDOWSDOORS LLC
650 MARKET STREET
GRATZ, PA 1703D
`\\\J\51R
`..; y\OENS�A•gi�
SERIES 420 SGD
96" X 80" NON -REINFORCED
NOTES
�pTAT E OF •tD�
/•;YoR1OP•
ONG NO.
RIN
085000T498
E
// NAiIEdG���\
Luis R. Lomas P.E.
FL No.: 62514
TUTS °"TIE 02/23/09 OF 1D
L.ROBERTOLOMASP.E
1432WO0OFORDRDLEWISV6LENC2M23
A-6B&0609 mon„sc>.Tw�mecom
F1
HI
96" MAX FRAME WIDTH
(2) ANCHORS PER LOCATION
SEE CHART #3
FOR NUMBER OF
LOCATIONS REQUIRED
17'
6' MAX -
MIX
I O.C.
6" MAX
T_
17"
MAX O.C.
O
to" T
IAX
I�
6' MAX
I
SERIES 420 SGD
EXTERIOR VIEW
DESIGNPRESSURERATING IMPACTRATING
+40.OPSF NONE
SEE CHARTS#1 AND#2 FOR OTHER UNITS RATINGS
NOTES:
1. MAXIMUMPANELSI21E:4612'x79'
2. MAXIMUM D.L.O.: 44 58'1, 7438'
HARDWARESCHEDULE
- 6" MAX
RNSICIS
REV
06CIe4TON
ATE
AP ii
A
ADDED CHARTS
03/05/12
1 R.L
8
REVISED PER NEW TESTING
10/29/13
R.L
C
ADDED FLANGE AND PIN INSTALLATIONS
12/06/13
R.L
D
REVISED INSTALLATION DETAILS
07/30/15
R.L
E
REVISED INSTALLATION DETAILS
06/20/17
R.L.
CHART#1
WHERE WATER INFILTRATION RESISTANCE IS REQUIRED.
SEE NOTE 9 SHEET I
Design pressure chart (psO
From
Single Panel and Total Frane Width
(in)
Height
30.0
36.0
42.0
48.0
72.00
Bd00
96.00
(In)60.00
Po¢
I Nee
I Ps¢
Nag
I POE
Meg
I POE
I Meg
80.01
40.0
1 55.1
1 4D.0
45.2
1 40.0
43.4
1 40.0
1 40.0
CHART#2
WHERE WATER INFILTRATION RESISTANCE IS NOT REQUIRED.
SEENOTE 9 SHEET 1
Design pressure chart (psO
Single Panel and Total Frane AIM
(in)
From
Haight
36.0
42.0
41.0
9000.
72.00
B4.00
"1
(In)
Pos
Nag
I POE
I Nag
I Pas
Nag
I Poe
Meg
B0.01
55.1
55.1
1 48.2
1 48.2
1 43A
43.4
1 40.0
40.0
CHART#3
Number oranchor looafions required
Single Panel and Tolal Fro" N4dth(in)
From
Heigh
30.0
36. 0
d2.0
dB.O
60.0
72.0
B4.0
96.0
(1
H&S
I Jamb
I H&S
I Jamb
H&S
I Jamb
I Has
I Jamb
B0.01
4
1 5
1 5
1 5
6
1 5
1 6
1 5
MI WINDOWS AND DOORS LLC
650 WEST MARKET STREET
GRATZ, PA 17030
SERIES 42D SGD
96" X 80" NON -REINFORCED
ELEVATION
OB-00498
NTS DaE 02/23/09 _2 OF I-
L ROBERTO LOMAS P.E.
1432 WDODFORD RD LEWISVB .AC 2700
434-&&0609 rllomaz@Mamaspe rom
SIGNED: O6/20/2017
Luis R. Lomas P.E.
FL MD.: 62514
E
N
FR
HE
96" MAX FRAME WIDTH
(1) ANCHOR PER LOCATION
AT HEAD & JAMBS
SEE CHART #4
FOR NUMBER OF
LOCATIONS REQUIRED
17'
6' MAX
I(
I
D.C.A
6" MAX
17"
MAX O.C.
D'
4X
0
X
\�
WE
GMT
6' MAX L
6" MAX
CHART#4
Number olenohorlocatlamnqulntl
6h0la
PenalmM Toml Unl Wdlb (N)
Rare
Ha0hl
]0.0
]6.0 42.0 48.0
(0)1
60.0
11720 64.0 96.0
Has
Jamb
I ;
Jamb Has
Jamb
60.01
4
i 5
6 5 6
9 6
1 5
SERIES 420 SGD
EXTERIOR VIEW -
(2) ANCHORS PER LOCATION
AT SILL
DESIGNPRESSURERATING IMPACTRATING SEE CHART #4
FOR NUMBER OF
t40.0PSF NONE LOCATIONS REQUIRED
SEE CHARTS #1 AND #2 SHEET2 FOR OTHER UNITS RATINGS
NOTES:
1. MAXIMUM PANEL SIZE. 48 VPx 79'
2. MAXIMUM D.LO.: as &I?'Y 74 518-
ON CENTER FROM
F.A.
REYSIONS
OESCRIPIION
M1E
MPROVI
ADDED CHARTS
03/05/12
R.L.
REVISED PER NEW TESTING
10/29/13
R.L
ADDED RANGE AND FIN INSTAUATIONS
12/06/13
R.L
REVISED INSTALLITION DETAILS
07/30/15
R.L
REVSED INSTALLATION DETAILS
06/20/17
R.L
SIGNED: 0612012017
MI WINDOWS AND DOORS LLC
650 WEST MARKET STREET
GRATZ. PA 17030
SERIES 420 SGD
96" X 80" NON —REINFORCED
FIN ELEVATION
OB0B E/�1
lit A�lE\``
DATE 02�
LROBERTOLOMASP.E LDIB R. Lomas P.E.
14]2WOODFORDRDL SWUS..NC2=3 FL N0.1 62574
494-689-0609 #la..@ romaape.rom
RLY6ION9
1/2" MIN.
RW
DMCRIRRON
WTE
.w ROWD
EDGE DISTANCE
A
ADDED CHARTS
03/05/12
R.L
B
REVISED PER NEW TESTING
10/29/13
R.L
1 3/8" MIN.
C
ADDED FLANGE AND FIN INSTALLATIONS
12/06/13
R.L.
WOO
EMBEDMEM
ORD 2FRAMING X BUCK
I
D
REVISED IN5TPLLATION DETAILS
O]/3D/15
R.L.
BY OTHERS
MAX.
E
REVISED INSTALLATION DETAILS
06/20/17
R.L
SHIM
#10 WOOD
SPACE
1 3/8" MIN. 1/4" MAX.
SCREW
EMBEDMENT SHIM SPACE
7
INTERIOR
1/2" MIN.
EDGE DISTANCE
EXTERIOR II II II II INTERIOR
#10 WOOD
SCREW
I WOOD FRAMING
OR 2X BUCK
BY OTHERS
NOTES:
I. INTERIORAND EXTERIOR FINISHES, BY OTHERS
NOT SHOWN FOR CLARITY.
2 PERIMETERANDJOINTSEAL4NIT BY OTHERS TO BE
DESIGNED INACCORDANCE WITHASTM E2112
SET IN
APPROVED SEALANT
#10 WOOD
SCREW
WOOD FRAMING
OR 2X BUCK
BY OTHERS
MIN.
AENT
MIN.
iTANCE
q__ EXTERIOR
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCKINSTALLATION
SIGNED: 0612012017
MI WINDOWS ANDDOORS LLC
650 WEST MARKET STREET
GRATZ, PA 17030•�\G
ENp*s:,p �
0=
SERIES 420 SGD
96" X 80" NON -REINFORCED
FRAME INSTALLATION DETAILS
pTATE OF •t0C
DRAW*.
mo No.
RLv
OB
E
',A7s(OIIIN1110?
Luis R. Lomas P.E.
FL No.: 62514
scuE NTS — 02/23/09 Is'-4 OF
OF 10
LRORERTOLOhWSP.E
1A32 WOODPORD RD LEMSVILLE NO270P3
4 4E 0609 mOmaz@WOmasparom
MIN.
EDGEE D DISTANCE
METAL �� pp 1/4' MAX.
STRUCTURE r SHIM SPACE
BY OTHERS
#1D SMS OR
SELF DRILLING
SCREW
METAL
STRUCTURE
BY OTHERS
#10 SMS OR
SELF DRILLING
SCREW
EXTERIOR II II II It INTERIOR
;ILL TO BE SET IN
1 BED OF
1PPROVED SEALANT
1/2' MIN.
EDGE DISTANCE
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLA77ON
NOTES:
1. INTERIOR AND EXTERIOR FINISHES. BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINTSEALANTBY OTHERS TO BE
DESIGNED IN ACCORDANCE WRHASTM E2112
1/2' MIN.
EDGE DISTANCE
I
#lD SMS OR
SELF DRILLING
SCREWS
METAL
STRUCTURE
BY OTHERS
1/4` MAX.
SHIM SPACE
RNSWO
REV
DMRI"ON
M1E
APPRdIED
A
ADDED CHARTS
03/05/12
R.L
B
RMSED PER NEW TESTING
10/29/13
R.L.
C
ADDED RANGE AND FIN INSTALIATIONS
12/06/13
R.L.
D
REVISED INSTALIATION DETAILS
07/30/15
R.L
E
RMSED INSTALLATION DETAILS
06/2D/17
R.L
JAMB INSTALLATION DETAIL
METAL STRUCTUREINSTALLATION
MI WINDOWS AND DOORS LLC
650 WEST MARKET STREET
GRATZ. PA 17030
SERIES 42D SGD
96" X BO" NON -REINFORCED
FRAME INSTALLATION DETAILS
DRAWN: Mc W.
F.A. 08-00498
' NTS Imn 02/23/09 ISKMS OF 10
LRO6ERTOLOMASP.E
IM WOOOFORD ROLEWISVILLE, NO2T023
4308 609 dbmas[dtrlomesp .
SIGNED: 0612012017
Luis R. Lomas P.E.
FL No.: 62514
RWSIDN5
1 1/2" MIN _
1" MIN. {{
RW
D6DRIRDOx
mm
.wRRw6o
SEPARATION
EDGE DISTANCE
A
ADDED CHARTS
03/05/12
R.L
.
B
REVISED PER NEW TESTING
10/29/13
R,L
7' "
C
ADDED FLANGE AND FIN INSTALLATIONS
12/O6/13
R.L.
c
`a•'a:.
1 1/4" MIN.
EMBEDMENT
D
REVISED INSTALLATION DETAILS
07/3D/15
R.L
CONCRETE/
."i •
1 1/4' MIN.
EMBEDMENT
E
REVISED INSTALLATION DETAILS
06/2D/17
R.L
MASONRY
_L
7/4'MAX'
BY OTHERS
SHIM SPACE
OPTIONAL
1X BUCK
n .. ..
1/4. MAX
TO BE
1"
SHIM SPACE
PROPERLY
MIN.
I INTERIOR
SECURED
SEE NOTE 3
EDGE
DISTANCE.
SHEET 1
h
3/16" TAPCON
3/16" TAPCON
MASONRY/
CONCRETE
BY OTHERS
EXTERIOR II II II II INTERIOR
SILL TO BE SET IN
A BED OF APPROVED SEALANT
a �
I°� a 1 1/4" MIN.
EMBEDMENT
d
E' a
d:
2 7/8` MIN 1" MIN.
SEPARATION EDGE DISTANCE
VERTICAL CROSS SECTION
CONCRETE/MASONRY INSTALLATION
MIN
SEPARATION
3/16" TAPCON
i
EXTERIOR
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK JAMB INSTALLATION DETAIL
TO BE PROPERLY CONCRETEIMASONRYINSTALLATION
SECURED
SEE NOTE 3 SHEET 1
NOTES:
' 1.INTERIORAND EXTERIOR FINISHES. BY OTHERS,
NOTSHOWNFORC"RITY.
2. PERIMETERAND JOINT SEALANTBYOTHERS TO BE
DESIGNED INACCORDANCE WIMASTM E2112
SIGNED: 0612012017
DObRSLLC
MI DW
650ST MARKET STREET
GRATZ. PA 17030
`\`Vt..IIC1q/*
'`may
•y�GENs�"4jt��
SERIES 420 SGD
z:
96" X BO" NON —REINFORCED
FRAME INSTALLATION DETAILS
1p • TAT OF
owc xo.
RE
F.A.: 08-00498
scuE NTS 02/23/09 ISHM6 OF 10
� 11EN
LROBERTOLOAWSPE
10.32 WOOOFORD RD LEWISVILLE NC270 3
Luis R. Lomas P.E.
a 43884609 mamaz@Nomaspe.mm
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
1/2" MIN.
EDGE DISTANCE
1 3/8" MIN.
EM�BEOME14T
1/4• MAX
SHIM SPACE
#10 WOOD
SCREW
EXTERIOR 11 11 II 11 INTERIOR
IE SET IN
APPROVED SEALANT
#10 WOOD
SCREW
I WOOD FRAMING
OR 2X BUCK
BY OTHERS
MIN.
SENT
MIN.
.... DISTANCE
VERTICAL CROSS SECTION
WOOD FRAMING OR2X BUDK INSTALLATION
NOTES,
1.INTERIORANDEXTEF11OR17N1SHES, BYOTHEIIS,
NOT SHOWN FOR CLARITY.
2 PERIMEMRANOJOINTSEALANTBYOTHERSTOBE
DESIGNED 1N ACCORDANCE WITH ASTM E2112
1 3/8" MIN.
EMBEDMENT
T-
1/2" MIN.
EDGE DISTANCE
#10 WOOD
SCREWS
WOOD FRAMING
OR 2X BUCK
BY OTHERS
/A" MAX.
SHIM SPACE
RM100
DESCRIPTION
mm
APPRWED
ADDED CHARIS
03/05/12
R.L
REVISED PER NEW TESONG
10/29/13
R.L
ADDED RANGE AND FIN INSTALLATIONS
12/06/13
R.L
REVISED INSTAUATION DETAILS
07/30/15
R.L
REVISED INSIAUAPON DEIAII_S
06/20/17
R.L.
INTERIOR
L.— EXTERIOR
JAMS INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
SIGNED: 06/20/2017
MI WINDOWS LLC
650 WEST MARKET STREET
\\\\�\5111�11ILJq� '''/'
GRATZ, PA 17030
`�••yNOENSF'9cps
a 1�f+c
SERIES 420 SGD*•
96" X 80" NON —REINFORCED
_y ��+*;
FLANGE INSTALLATION DETAILS
E C
TAT OF
DRAWN:
"a N0.
REV
08
E
/'SA�1�N�\``
Luis R. Lomas P.E.
FL NO.: 62514
scuF NTS s DAh 02/23/09 DD78 OF 10
L ROBERTO LOMAS RE
10. WOODFORDRDLEWISVILLE, NC27023
d0d8HB-0609 01Pmas@MOmaspe.nun
1/2" MIN.
EDGE DISTANCE
METAL
STRUCTURE
BY OTHERS
#10 SMS OR
SELF DRILUNG
SCREW
I METAL
STRUCTURE
BY OTHERS
EXTERIOR
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES. BY OTHERS.
NOTSHOWNFORCLARITY.
2. PERIMETERANDJOINTSEALAM'BYOTHERSTOBE
DESIGNED INACCORDANCE WITHASTM E2112
1/4" MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING
SCREW .
INTERIOR
1 TO BE SET IN
BED OF
,PROVED SEALAM
1/2• MIN.
EDGE DISTANCE
RM 00
DMRIPTON
ppw
µPROVED
ADDED CHARTS
p3/05/12
R.L
REVISED PER NEW TESTING
10/29/13
R.L
ADDED FLANGE AND FIN INSTALLATIONS
12/O6113
R.L
REVISED INSTALLATION DETAILS
07/3D/15
R.L
REVISED INSTALLATION DETAILS
O6/2D/17
R.L
_ 1/4" MAX.
SHIM SPACE
1/J
MIN. INTERIOR
EDGE
DISTANCE
#10 SMS OR
SELF DRILLING
SCREWS
METAL
STRUCTURE
BY OTHERS
k__ EXTERIOR
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
SIGNED: 0612012017
MI WINDOWS OORS LLC
11�II1�10
BSD WEST M RKE STREET
A /'
GRATZ. PA 17030
`��••��GENs�;'9j1��
D
*�. _=_
SERIES 420 SOD
95" % BO" NON -REINFORCED
M,T'5O7RxFO•�
FLANGE INSTALLATION DETAILS
W�
;•�M
'',,ASS/OI
DRnxu
Hirt NO.-0049
RLv
DB
E
IIAII1�aG\``\
LDI6 R. Lomas P.E.
FL No.: 62514
NTS DATE 02/23/D9 N�TBB OF ID
LROBERTOLOMASP.E
1t M2 DMRDRDLEWISVILLC,NC27023
C90deB-0609 plomas@Mwnaspe.rom
CONCRETE/
MASONRY
BY OTHERS
OPTIONAL
1X BUCK
TO BE
PROPERLY
SECURED
SEE NOTE 3
SHEET 1
3/16" TAPCON
MASONRY/
CONCRETE
BY OTHERS
1 1/2" MIN Y MIN. _I
SEPARATION EDGE DISTANCE
aA n ..
1 1/4" MIN.
"a EMBEDMENT
1/4" MAX.
SHIM SPACE
3/16" TAPCON
EXTERIOR II I I1__I1 INTERIOR
1 1/4" MIN'
EMBEDMENT �I
RLv¢IDxs
REV
D6CHIRION
DAIS
MPRO D
A
ADDED CHARIS
03/D5/12
R.L.
8
REVISED PER NEW TESTING
1D/29/13
R.L
C
ADDED FIKNGE AND RN INSTALLATIONS
12/06/13
R.L
D
REVISED INSTALLATION DETAILS
07/30/15
R.L
E
REVISED INSTALLATION DETAILS
06/20/17
R.L
1/4" MAX.
SHIM SPACE
1.
MIN.
INTERIOR
EDGEDISTANCE
L
3"
MIN
❑ I
El
SEPARATION
va
3/16" TAPCON - EXTERIOR
SILL TO BE SET IN
A BED OF CONCRETE/MASONRY
APPROVED SEALANT BY OTHERS
JAMB INSTALLATION DETAIL
OPTIONAL 1X BUCK CONCRETFJWSONRYINSTAUATION
-
a, 1 1/4" MIN.
a''_ . EMBEDMENT
a. d'
a'
2 7/8" MIN _ 1" MIN.
SEPARATION EDGE DISTANCE
VERTICAL CROSS SECTION
CONCRETEMASONRY INSTALLATION
TO BE PROPERLY
SECURED
SEE NOTE 3 SHEET 1
NOTES:
1. INTERIORAND EXTERIOR FINISHES. BY OTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETERAND JOINT SEALANTBYOTHERSTO SE
DESIGNED INACCORDANCE WITHASTM E2112
MI WINDOWS AND DOORS LLC
650 WEST MARKET STREET
GRATZ. PA 17030
SERIES 420 SGD
96" X 80" NON —REINFORCED
FLANGE INSTALLATION DETAILS
M": Dwc uD.
F.A. 08—D0498
s NTS I DATE D2/23/D9 1sR 9 OF 10
SIGNED: 0612012017
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
BY OTHERS
1/4" MAX
SHIM SPACE
#B WOOD
OOD
SCREW
INTERIOR
1 1/4"
MIN.
EMBEDMENT
aeslDNs
D6LRIPIION
"M
APPRO
ADDED CHARTS
p3/OS/12
R.L
REVISED PER NEW TIESRNC
10/29/13
R.L
ADDED FLANGE AND FIN INSTALLATIONS
12/06/13
R.L
REVISED INSTALLATION DETAILS
07/30/15
R.L
REVISED INSTALLATION DETAILS
05/20/17
R.L
1 5/8" MIN.
EDGE DIST. I
APPROVED SEALANT A I
BEHIND FIN EXTERIOR TRIM
1 1/4" MIN.
7/167MINCE _ INTERIOR EMBEDMENT
EDGE DISTANCE
MASONRY/CONCRETE
JAMB INSTALLATION DETAIL BY OTHERS
WOOD FRAMING OR2X SUCKINSTALLATION METAL STRUCTURE {--F 1/2" MIN. 1X BUCK BY OTHERS,
BY OTHERS I I EDGE DISTANCE HOOK STRIP 1% BUCK TO BE
APPROVED SEALANT TRIM I I PROPERLY SECURED
BEHIND FIN 1 1/4" MIN -
EMBEDMENT
TAPCON
EMBEDMENT WOOD FRAMING EXTERIOR PANEL INTERLOCK
j/B WOOD BY OTHERS INTERIOR
SCREW
HOOK STRIP INSTALLATION
1/4" MAX. HOOK STRIP MASONRWCONCRETE
_F SHIM SPACE #10
SCR
SELF DRILLING
S
7/16" MIN SCREW
EDGE DISTANCE
EXTERIOR
INTERIOR
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
FOR SILL INSTALLATION SEE SHEETS 4.9.
NOTES:
1. INTERIOR AND EXTERIOR FINISHES. BY OTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETER AND JOINT SEALANTBY OTHERS TO BE
DESIGNED INACCOROANCE WITH ASTM E2112
2X BUCK OR
WOOD FRAMING
BY OTHERS
TRIM
INTERIOR
HOOK STRIP
1-1 PANEL
EXTERIOR INTERLOCK
HOOK STRIP INSTALLATION
METAL STRUCTURE
1/2" MIN.
1 EDGE DISTANCE
1 3/8" MIN.
EMBEDMENT
❑ WOOD
SCREW kFA-
EXTER
PANEL IOR INTERLOCK
HOOK STRIP INSTALLATION
2X BUCK OOD FRAMING
SIGNED: 0612012017
Ml WINOOWS AND DOORS
OELLC
650W WEST MARKETT
STREET
GRATZ, PA 17030
EN;pF'91P
SERIES 420 SGD
96" X BD" N014—REINFORCED
FIN AND HOOK INSTALLATION DETAILS
pTATE OF •tp\
DAv No.
RLv
08-00498
E
/11N111M
Luis R. Lomas P.E.
FL No.: 62514
DATE 02/23/09 --lD OF 10
L ROBERTO LOMAS RE
IA32W000MRDRDaMSVIU.E,Na27023
i 6B 609 4bmas@Rbmas(>e.wm
4/2412020 Florida Building
FLOR100,09PAMIK OF
Business & Professional r r
• acts Home I Login I User Registration I HotTopi¢ Submit Surcharge I S
Florida v
n r1 Product Approval
UUvvrr�� USER: Public User
6`3r�ri,suu,
SHOPSTAMPREVIEW lutelmn
Review Is for general compliance with the Construction Documents.
Responsibility for comecmess of dimensions, details, quantities and safety
during fabrication Iles solely with the contractor.
X NoExceptions Taken Reviewedav: Dawn Boggio-Korbelak
0 Rejected:
sts fi Facts I Publications I contact Us I acts site Map I Links I Sopron
4/28/20 !1 . $
CiArA't
Product Approval Menu > Product or ngpllration Search > Application U > Application Detall
FL #
FL16503-R3
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived ❑
Product Manufacturer KAYCAN LTD
Address/Phone/Email 1 Memorial Drive
Richford, VT 05476
(662) 252-9991 Ext 231
joe.lundine@kpproducts.com
Authorized Signature Joe Lundine
joe.lundine@kpproducts.com
Technical Representative Joe Lundine
Address/Phone/Email 402 Boyer St
Williston, VT 05495
(662) 252-9991
joe.lundine@kpproducts.com
Quality Assurance Representative Joe Lundine
Address/Phone/Email 402 Boyer St
Williston, VT 05495
(662) 252-9991
joe.lundine@kpproducts.com
Category Panel Walls
Subcategory Soffits
Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. Amoruso, P.E.
Evaluation Report
Florida License
PE-49752
Quality Assurance Entity
Architectural Testing, Inc., an Intertek Company
Quality As$urdndeContract ExpliationiDdto
231.2020
Validated By
Steven M. Urich, PE
2 Validation Checklist- Hardcopy Received
Certificate of Independence
FL16503 R3 COI CI 2511 Rey0 Vinyl -Soffit ss.odf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1929
2012
ASTM D2843
2010
ASTM D3679
201
ASTM D63
REVISION 2010
ASTM D638
200303
ASTM E33G
ASTM E330
F1,LE COPY20014
https:/Avww.floridabuilding.org/prlpr app_dti.aspx?param= GEVXQwtDgvgqu2w%2bnFgUOixYpvHp/o2bzhsdip2DLe2QVvMgGNIV5TsM3A%3d%3d
1/3
4/24/2020 Flonda Building Code Online
ASTM G155-05a 2005
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
i
Florida Licensed Professional Engineer or Architect
FL16503 R3 Eouiv EER 2511 RevO Vinyl -Soffit ss.pdf
Method 1 Option D
12/08/2017
12/12/2017
12/20/2017
02/13/2018
FL ff
Model, Number or Name
Description
16503.1
12"Triple 4 Full-O-Vent Eco (No.
t639) -Single S ans
12 Triple 4 Full-O-Ve nt Eco (No., 0639) with Sing le Spans
Limits of Use
Approved for use in HVHZ: No
�Approved for use outside. HVHZ; Yes
iInstallation Instructions
7FL16503 R3 11 KAY0013 Rev -A 639Eco_ Vln ]Sv offit-
(Zngll"pan s`Ofj
(Impact Resistant; No
Design Pressure: N/A
erified By RobertJ. Amoruso, PE FL PE No. 49752
Created by independent Third Party: Yes
,Other: See Installation Instructions for Design Pressures.
lEvaiiiAh) Reports
FLI6503 R3 AE'PERI 2511-RevO Vjnyl-SoffiLsso
'�Crzated. y.In'dependent ThirdParttLYajs
16503.2
Triple 4 Full-O-Vent Eco (No. 0639) -
Triple 4 Full-O-Vent Eco (No. 0639) with Unlimited Spans
Unlimited Spans
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16503 R3 11 KAY0012 Rev A 639Eco VinylSofft-
Approved for use outside HVHZ: Yes
Unlimited 512an ss.gQj
Impact Resistant: No
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See Installation Instructions for Design Pressures.
Evaluation Reports
FL16503 R3 AE PER 2511 RevO Vinyl-Soffit-sr.psl(
Created by Independent Third Party: Yes
16503.3
Various Series Vinyl Soffit - Single
See Installation Instructions for Product Models Included.
Spans
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16503 R3 1I KAY0011 RevA VinylSoffit Sinale$ga1L_5s,gdf
Approved for use outside HVHZ: Yes
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See Installation Instructions for Design Pressures.
FL16503 R3 AE PER 2511 RevO Vinyl -Soffit ss.odf
Created by Independent Third Party: Yes
16503.4
Various Series Vinyl Soffit - Single
See Installation Instructions for Product Models Included.
Spans
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16503 R3 11 KAY0007 RevC VinylSof6t ss.odf
Approved for use outside HVHZ: Yes
Verified By: Robert J. Amoruso, P.E. FL Ucense No. 49752
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: See Installation Instructions for Design Pressures.
FL16503 R3 AE PER 2511 Ravi Vinyl -Soffit ss.odf
Created by Independent Third Party: Yes
16503.5
Various Series Vinyl Soffit - Unlimited
See Installation Instructions for Product Series included.
Spans
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16503 R3 11 KAY0009 Rev A VnyISOflR-
Approved for use outside HVHZ: Yes
UnlimitedSoan ss.pdf
Impact Resistant: No
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See Installation Instructions for Design Pressures.
Evaluation Reports
FLI6503 R3 AE PER 2511 RevO Vinyl -Soffit ss.odf
Created by Independent Third Party: Yes
https:IAx .floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUOixYpvH%2bzhsdip2DLe2QVVMgGNIV5TsM3A%3d%3d 213
4/24/2020
Florida Building Code Online
Balk Nett
Contact Ui:: 2601 Blalr Stone Road, Tallahassee R 32399 Phone: 850-4824824
The State of Florida Is an AAIEED employer. COQyllgbt 2002-2013 state of Florida.:: PH R [ :: Accessibility Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, eRecb s October 1, 2012, licensees Iicamed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls
provided may be used for oMclal communication with the licensee. However email addresses are public record. if you do not wish to supply a personal address, please
provide the Department with an small address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here.
Product Approval Accepts:
®®®0a®
Credit Card
Safe
hops:IAry floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUOixYpvH%2bzhsdip2DLe2QWMgGNIV5TsM3A%3d%3d 3/3
Product Evaluation
Rule 61G2-3 F.A.C. I Report No. 2511 1 Project No. 417-0612 1 11/27/17 1 Page 1 of 4
Product Manufacturer
Kaycan Ltd.
1 Memorial Drive
Richford, VT 05476
Code: Current Edition of the Florida Building Code
Product Name, Model and/or Description
Vinyl Soffit - Various
Compliance Method: 61G20-3.005(l)(d) — Product Evaluation Report by a Licensed Professional Engineer
Product Name, Model and/or Designation: Products covered by this evaluation include the following.
• KAY0007 — Single Spans
o
12"
TRIPLE 4 SOLID SOFFIT
o
12"
TRIPLE 4 VENTED SOFFIT
o
12"
TRIPLE 4 CENTER -VENT SOFFIT
o
12"
TRIPLE 4 CENTER-O-VENT SOFFIT
0
12"
TRIPLE 4 FULL-O-VENT SOFFIT
o
10"
DOUBLE 5 SOLID SOFFIT
o
10"
DOUBLE 5 VENTED SOFFIT
o
8" BEADED SOLID SOFFIT
o
8" BEADED VENTED SOFFIT
• KAY0009—Unlimited Spans
0 12" TRIPLE 4 SOLID, NO. 0623 SOLID SOFFIT
0 12" TRIPLE 4 FULL-O-VENT, NO. 0622 VENTED SOFFIT
0 12" TRIPLE 4 FULL-O-VENT ECO, NO. 0639 VENTED SOFFIT
• KAY0011 — Single Spans
0 12" TRIPLE 4 SOLID, NO. 0623 SOLID SOFFIT
0 12" TRIPLE 4 FULL-O-VENT, NO. 0622 VENTED SOFFIT
0 12" TRIPLE 4 FULL-O-VENT ECO, NO. 0639 VENTED SOFFIT
• KAY0012—Unlimited Spans
o 12" TRIPLE 4 FULL-O-VENT ECO, NO. 0639 VENTED SOFFIT
• KAY0013—Single Spans
0 12" TRIPLE 4 FULL-O-VENT ECO, NO. 0639 VENTED SOFFIT
Product Installation Instructions:
• PTC Product Design Group LLC, Drawing No. KAY0007, Rev. C, Dated 11/27/17, by Robert J. Amoruso,
P.E., Kaycan LTd. Vinyl Soffit - Solid and Vented, Installation Anchorage Details.
• PTC Product Design Group LLC, Drawing No. KAY0009, Rev. A, Dated 11/27/17, by Robert J. Amoruso,
P.E., Kaycan LTd. Vinyl Soffit — Various Solid and Vented with Unlimited Spans, Installation Anchorage
Details.
• PTC Product Design Group LLC, Drawing No. KAY0011, Rev. A, Dated 11/27/17, by Robert J. Amoruso,
P.E., Kaycan LTd. Vinyl Soffit —Solid and Vented with Single Spans, Installation Anchorage Details.
��AMr PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
Arwff L 321-690-1788 1 FBPE Certification of Authorization No. 25935
Product Evaluation
Rule 61G2-3 F.A.C. I Report No. 2511 1 Project No. 417-0612 1 11/27/17 1 Page 2 of 4
PTC Product Design Group LLC, Drawing No. KAY0012, Rev. A, Dated 11/27/17, by Robert J. Amoruso,
P.E., Kaycan LTd. Vinyl Soffit - 12"Triple 4 Full-O-Vent Eco (No. 0639) with Unlimited Spans, Installation
Anchorage Details.
PTC Product Design Group LLC, Drawing No. KAY0013, Rev. A, Dated 11/27/17, by Robert J. Amoruso,
P.E., Kaycan LTd. Vinyl Soffit -12" Triple 4 Full-O-Vent Eco (No. 0639) with Single Spans, Installation
Anchorage Details.
Industry Standard -Vinyl Siding Institute's Vinyl Siding Installation Manual, December 2015.
Test Reports and Performance Testing Standards Used:
KAY0007
• Fenestration Testing Laboratory, Inc. Testing Report No. 7367, dated 6/1/13 including associated
laboratory stamped drawings for Kaycan Vinyl Soffit testing to ASTM E330-02.
• Architectural Testing Inc. Test Report No. ATI 55983.01-106-18, dated 1/3/2006 for Kaycan Vinyl Soffit
and Siding, materials testing to:
i) ASTM D3679-01c, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding
ii) ASTM G155-00ae1, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non -
Metallic Materials
ill) ASTM D638-03, Standard Test Method for Tensile Properties of Plastics
iv) ASTM D2843-99, Standard Test Method for Density of Smoke from the Burning or Decomposition of
Plastics
v) ASTM D1929-96 (2000)e01, Standard Test Method for Determining Ignition Temperature of Plastics
vi) ASTM D635-98, Standard Test Method for Rate of Burning and/or Extent and Time of Burning of
Plastics in a Horizontal Position
KAY0009, KAY0011, KAY0012 & KAY0013
• Molimo Architectural Product Testing, 1410 Eden Road, York, Pennsylvania 17402—Vinyl Soffit Product
Testing
i) Test Report No.1169.01-106-11, SERIES / MODEL: 0623 Solid Vinyl Soffit, "J" Channel / Fascia
Installation, ASTM E330-14, dated 2/13/17
ii) Test Report No.1169.02-106-11, SERIES / MODEL: 0623 Solid Vinyl Soffit, "J" Channel / "1" Channel
Installation, ASTM E330-14, dated 2/13/17
ill) Test Report No. 1170.01-106-11, SERIES / MODEL: 0622 Vented Vinyl Soffit, "J"
Channel / Fascia
Installation, ASTM E330-14, dated 2/13/17
iv) Test Report No. 1170.02-106-11, SERIES / MODEL: 0622 Vented Vinyl Soffit, "1"
Channel / "J'
Channel Installation, ASTM E330-14, dated 2/13/17
v) Test Report No. 1171.03-106-11, SERIES / MODEL: 0639 Vented Vinyl Soffit, "1"
Channel / Fascia
Installation, ASTM E330-14, dated 2/13/17
vi) Test Report No. 1171.04-106-11, SERIES / MODEL: 0639 Vented Vinyl Soffit, "J"
Channel / "J"
Channel Installation, ASTM E330-14, dated 2/13/17
vii) Test Report No. 1171.01-106-11-R1, SERIES / MODEL: 0639 Vented Vinyl Soffit,
"J" Channel / Fascia
Installation, ASTM E33o-14, dated 1/31/17
PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
i/ L 321-690-1788 1 FBPE Certification of Authorization No. 25935
Product Evaluation
Rule 61G2-3 F.A.C. I Report No. 2511 1 Project No. 417-0612 1 11/27/17 1 Page 3 of 4
Architectural Testing Inc. Test Report No. ATI 55983.01-106-18, dated 1/3/2006 for Kaycan Vinyl Soffit
and Siding, materials testing to:
i) ASTM D3679-01c, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Siding
ii) ASTM G155-00ael, Standard Practice for Operating Xenon Arc Light Apparatus for Exposure of Non -
Metallic Materials
iii) ASTM D638-03, Standard Test Method for Tensile Properties of Plastics
iv) ASTM D2843-99, Standard Test Method for Density of Smoke from the Burning or Decomposition of
Plastics
v) ASTM D1929-96 (2000)e01, Standard Test Method for Determining Ignition Temperature of Plastics
vi) ASTM D635-98, Standard Test Method for Rate of Burning and/or Extent and Time of Burning of
Plastics in a Horizontal Position
Engineering Evaluation:
• See Appendix A for Code Conformance Evaluation
• Anchorage engineering and test result interpretation are documented in the following:
o PTC Product Design Group LLC, Report No. 2240, Engineering analysis for Kaycan Vinyl and
Aluminum Soffit, dated 7/11/13, by RobertJ. Amoruso, P.E.
o PTC Product Design Group LLC, Report No. 2492, Engineering analysis for Kaycan Vinyl and
Aluminum Soffit, dated 3/20/17, by RobertJ. Amoruso, P.E.
Limitations & Conditions of Use:
• This product has not been evaluated for use inside the High Velocity Hurricane Zone (HVHZ).
• Refer to Product Installation Instructions noted abovefor:
o Maximum allowable wind loads at related maximum allowablesize(s).
o Overall dimensions and material/grade of main product components, accessories, etc.
o Illustrated diagrams of the attachment of the product to substrate structure.
o Anchor type(s), size(s), substrate(s), embedment, edge distance, and spacing/locations.
• Site wind pressures shall be determined by a licensed professional engineer in accordance with the
current edition of the Florida Building Code and/or ASCE 7-10 for components and cladding based on
allowable stress design.
• Site conditions not covered in this product evaluation document are subject to additional engineering
analysis by a licensed professional engineer or registered architect as required by the authority having
jurisdiction.
• Adequacy of the existing structural substrates as a main wind force resisting system capable of
withstanding and transferring applied product loads to the foundation is the responsibility of the
licensed professional engineer or registered architect acting as the design professional of record for
the project of installation.
��A� PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
iiAW 321-690-1788 1 FBPE Certification of Authorization No. 25935
Product Evaluation
Rule 61G2-3 F.A.C. I Report No. 2511 ]Project No. 417-0612 1 11/27/17 ]Page 4 of 4
Certificate of Independence per Product Approval
Rule 61G20-3.009
PTC Product Design Group, LLC and Robert J.
Amoruso, P.E. does not have, nor will acquire, any
financial interest in the company manufacturing or
distributing product(s) covered by this Product
Evaluation Report.
PTC Product Design Group, LLC and Robert J.
Amoruso, P.E. do not have, nor will acquire any
financial interest in any other entity involved in the
approval process or testing of the product(s) covered
by this Product Evaluation Report.
Appendix A —Code Conformance Evaluation
Evaluated by:
RobertJ. Amoruso, P.E.
FL PE License No. 49752
• Vinyl soffit certified and labeled as conforming to the requirements of ASTM D3679.
• Vinyl soffit tested to 1.5 x Design Pressure.
• Vinyl soffit labeled in accordance with the Florida Building Code.
• Vinyl soffit plastics comply with Chapter 26 of the Florida Building Code as shown below.
u
t
V
M
7
N O
M
Test Standard
A
Ca
N
q o
Ca
0
F1
F
m
d
C
Gn
W
Acceptance Criteria
Tensile
Self-
Smoke
Class
P/F
N/A
Test
Density
Ignition
CC1 or
Test
Variation
Temp
Test Report
Report
Product
< 10%
�
— 75
> 3430C
CC2
Date
4 0C
Tested
8
55 83I01-
1/3/2006
Vinyl Soffit
Passed
to
CC1
106-18
Passed
max
max
max
max
4970C
��A� PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
OWN& 321-690-1788 1 FBPE Certification of Authorization No. 25935
KAYCAN LTD
VINYL SOFFIT - 12" TRIPLE 4 FULL-O-VENT ECO (NO. 0639)
GENERAL NOTES:
1. THIS PRODUCT HAS BEEN TESTED AND DESIGNED TO COMPLY WITH THE
CURRENT EDITION OF FLORIDA BUILDING CODE -BUILDING AND RESIDENTIAL
VOLUMES EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ)AT THE
DESIGN PRESSURES SHOWN ON SHEET 1. THESE PRODUCTS WERE TESTED
TO ASTM E33M4. STRUCTURAL TEST RESULTS BASED ON ASTM E33614
WERE DIVIDED BY 1.5 AS REQUIRED BY THE BUILDING CODE.
2. DESIGN PRESSURE (DP) RATINGS SHOWN ON THIS SHEET ARE BASED ON IO-
SAVE WIDTHS IN SINGLE SPANS. SPAN WIDTHS AT 10-, 12',14- AND 1VME
SHOWN ON SHEET 2.
3. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON TESTING
PERFORMED AT MOLIMO ARCHITECTURAL PRODUCT TESTING, 11410 EDEN
ROAD, YORK, PA 1740.
4. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE, MASONRY AND
WOOD FRAMING COMPRISING THE ATTACHMENT SUBSTRATE FOR THE
SOFFIT SHALL BE DETERMINED TO BE CAPABLE OF WITHSTANDING AND
TRANSFERRING APPLIED PRODUCT LOADS TO THAT STRUCTURE AND IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD FOR THE
PROJECT.
S. OVERHANGS RECEIVING SOFFIT SHALL BE CHECKED FOR STRUCTURAL
ADEQUACY, DAMAGE CRACKS OR DEFECTS THAT MAY PRECLUDE THE
SOFFIT FROM PERFORMING ITS INTENDED FUNCTIONS. SUCH DEFECTS
SHALL BE ELIMINATED PRIOR TO SOFFIT INSTALLATION.
6. INSTALLATION OF SOFFIT AND ACCESSORIES SUCH AS CORNER POSTS.
STARTER STRIPS, AND TRIM AROUND OPENINGS SHALL BE DONE IN
ACCORDANCE WITH THE CURRENT EDITION OF WE FLORIDA BUILDING CODE
- BUILDING AND RESIDENTIAL VOLUMES AND THE MANUFACTURER'S
INSTRUCTIONS.
7. SITE CONDITIONS THAT DEVIATE FROM THE DETAILS OF THIS DRAWING
REQUIRE FURTHER ENGINEERING EVALUATION BY A LICENSED ENGINEER OR
REGISTERED ARCHITECT
B. SOFFIT SHALL BE LABELED IN ACCORDANCE WITH THE CURRENT EDITION OF
THE FLORIDA BUILDING CODE
9. SOFFIT NET FREE AREA IN ACCORDANCE WITH THE CURRENT EDITION OF
THE FLORIDA BUILDING CODE ARE SHOWN IN THE APPROVED SOFFIT
SCHEDULE ON SHEET 1.
10. MATERIALS:
10.1. KAYCAN BUILDING PRODUCTS VINYL SOFFIT AND TRIM IS
MANUFACTURED FROM A FORMULATED PVC POWDER COMPOUND
MEETING THE SPECIFICATIONS OF ASTM 03679.
10.2. KAYCAN BUILDING PRODUCTS ALUMINUM TRIM IS MANUFACTURED FROM
ALUMINUM ALLOY WITH ASTM ES TESTED TENSILE STRENGTH OF 21 KSI
AND YIELD STRENGTH OF 9.86 KSI.
WITH SINGLE SPANS
INSTALLATION ANCHORAGE DETAILS
DESIGN PRESSURE (PSF) RATING AT 10" SPAN (NOTE 2)
INSTALLATION METHOD
DESIGNPRESSURE
NETFREEAREA
NETFREEAREA
VINYLSOFFIT SERIES
(SEE NOTE 2)
(PSF) (SEE NOTE 1)
(SO. INJUNEAL FT.)
(SQ. INJSQ. FT.)
FASCIA / J-CHANNEL
+66.7/-66.7
4.18
4.18
12' TRIPLE 4 GULL-D-VENT ECD
FASCIA / F-CHANNEL
J-CHANNEL / J-CHANNEL
+66.7/-66.7
1 4.18
4.18
NO. 0639 VENTED SOFFIT
F-CHANNEL / F-CHANNEL
NOTE 1: DESIGN PRESSURE RATINGS SHOWN ABOVE SHALL BE COMPARED TO LOADING BASED ON V.sd BASIC WIND SPEEDS. THUS PROJECT
DESIGN PRESSURES AS DETERMINED FROM ASCE 7-10 BASED ON Vult BASIC WIND SPEEDS ARE PERMITTED TO BE MULTIPLIED BY 0.6 PER THE
CURRENT EDITION OF THE FLORIDA BUILDING CODE FOR COMPARISON TO THE DESIGN PRESSURE RATINGS ABOVE.
NOTE 2: SEE SHEET 2 FOR DESIGN PRESSURES AT 1D', 12', 14' AND 16'. SEE SHEETS 3 AND 4 FOR SINGLE SPAN INSTALLATIONS FOR
TRUSS/WOOD FRAMING CANRLEVER AND OVERHANG FAVE CONSTRUCTION. SEE SHEET 5 FOR CONNECTDN DETAILS.
VINYL SOFFIT AND TRIM SCHEDULE
VINYL SOFFIT
J-CHANNEL
F-CHANNEL
FASCIA
SERIES
12" TRIPLE 4
1/2- J-CHANNEL
1/2- F-CHANNEL
4- FASCIA
FULL-O-VENT ECO
VINYL
VINYL
ALUMINUM
NO. 0539 VENTED
N0. 1100
N0. 1178
ND. 9700
SOFFIT
TABLE OF CONTENT
SHEET
DESCRIPTION
1
GENERAL NOTES, PERFORMANCE RATINGS, SOFFIT SCHEDULE
2
--
INSTALLATION NOTES AND DP RATINGS AT VARIOUS SPANS
3
INSTALLATION DETAILS, CANTLEVER CONSIRUCTION
4
INSTALLATION DETAILS, OVERHANG CONSTRUCTION
5
INSTALLATION DETAILS A THROUGH F
6
SOFFIT PROFILE
7
CHANNEL AND FASCIA PROFILES / BOM
RW J.A mry P.E.
Ala
z
VINYL AND ALUMINUM SOFFIT INSTALLATION INSTRUCTIONS
DP RATINGS AT VARIOUS SPANS
1. EAVE WIDTHS (SPANS)
1.1. THE INSTALLATION CROSS SECTIONS SHOWN ON SHEETS3 AND 4 DEPICT
SINGLE SPANS FOR EAVE CONSTRUCTION OF TRUSSAMOOD FRAMING IN
EITHER CANTILEVER OR OVERHANG CONFIGURATIONS. HOWEVER, THIS DOES
NOT LIMIT SOFFIT INSTALLATION TO THESE CONFIGURATIONS ONLY AS LONG
AS MINIMUM FASTENER REQUIREMENTS AND SPAN LIMITS ARE MAINTAINED.
1.2. SEE TABLE ON THIS SHEET FOR SPANS OF 10'. 12', leAND 16'.
2. INSTALLATION FASTENERS
2.1. FASTENERS SHALL BE THE TYPE, SIZE, EMBEDMENTAND EDGE DISTANCE
SHOWN HEREIN FOR RESPECTIVE SUBSTRATE. SEE FASTENER SCHEDULE
TABLE ON THIS SHEET.
2.2. MINIMUM EMBEDMENT EXCLUDE WALL FINISHES (INCLUDING BUT NOT
LIMITED TO STUCCO, FOAM, BRICK VENEER AND SIDING). EDGE DISTANCES
SHALL BE SUCH TO PREVENTIVE CRACKING OF SUBSTRATE MATERIAL.
2.3. FASTENER LENGTHS SHOWN IN THE INSTALLATION DETAILS DO NOTTAKE
INTO ACCOUNT WALL FINISHES. WALL FINISH THICKNESS SHALL BE ADDED TO
THE REQUIRED FASTENER LENGTHS. SEE FASTENER SCHEDULE TABLE ON
THIS SHEET.
3. 2X2 NOMINAL BATTEN INSTALLATION TO SUPPORTING SUBSTRATE STRUCTURE IS
THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD.
4. ALL FASTENERS SHALL HAVE CORROSION RESISTANT COATINGS OR BE MADE OF
CORROSION RESISTANT MATERIALS COMPATIBLE WITH THE SUBSTRATE
MATERIALS.
5. SEE INSTALLATION MOUNTING DETAILS AND ILLUSTRATIVE INSTALLATIONS ON
SHEETS 3,4 AND 5.
FASTENER SCHEDULE
FAS N.DFSCRMCN
BIIBBRUTE
Y.IX, FMBEOMEVE
I6EENOlEt)
EDGE DIBTPNLE
O.D97' DIAMETER x
CONCRETE
1'
1/4'
1-1/2' T-NAIL
OR MASONRY
0.072' DIAMETER X
WOOD
1-3/4'
1/4-
1-3/4* TRIM NAIL
15 GA X 7/16' WIDTH
CROWN STAPLE 1' MIN.
WOOD
7/B'
1/4'
LENGTH
8B x 3' M WOOD SCREW
OR 3' M TAPPING
WOOD
1-1/2'
5/8'
SCREW.
3/16- RW TAPCON
CONCRETE
1•
1-1/8'
CONCRETE SCREW
OR MASONRY
NOTE 1: EMBEDMENT BASED ON NOMINAL LENGTH OF FXSTENER
THROUGH SOFFIT OR CHANNEL INTO SUPPORTING SUBSTRATE W/O WALL
RNISHES. WHERE WALL FINISHES ARE PRESENT, THE FASTENER LENGTH
WILL BE INCREASED AS REQUIRED TO MNNTNN EMBEDMENT DEPTH INTO
SUPPORTING SUBSTRATE
DESIGN PRESSURE (PSF) AT VARIOUS SINGLE SPAN LENGTHS
12" TRIPLE 4 FULL-O-VENT ECO / NO.0639 VENTED SOFFIT
Single Span Length
11L"
INSTALLATION DETAILS
A THRU F (SHEET 5)
Positive
Negative
10
ALL
66.7
-66.7
12
ALL
55.6
-55.6
14
ALL
47.6
-47.6
16
ALL
41.7
-41.7
a
e
C
g
0
W
u
0
Ro
rEa
aE
dw
�
tia
N
a
8
M
egg
�
=
6
z
R.Wd1.Mprvm.P£
FIo,IEe P.E. No. 09/52
Y-
TRUSS/FRAMING CANTILEVER EAVE CONSTRUCTION
EAVE WIDTH
(ROOF
OVERHANG)
—CONCRETI
SOFFIT CMU/ WOO OR
SEE DETAIL "A' SEE DETAIL "B"—/ WOOD
(NOTE 1)
EAVE CROSS-SECTION
SINGLE SPAN W/F-CHANNEL
F-CHANNEL @ WALL, FASCIA @ FASCIA END
i= SPAN "L' . k
SAVE WIDTH
(ROOF
OVERHANG)
�CONCRETI
CMU OR
SOFFIT! WOOD
SEE DETAIL "A" SEE DETAIL 'C' (NOTE 1)
EAVE CROSS-SECTION
SINGLE SPAN W/J-CHANNEL
J-CHANNEL @ WALL, FASCIA @ FASCIA END
EAVE WIDTH
(ROOF
OVERHANG)
SOFFIT
SEE DETAIL "D"— SEE DETAIL
EAVE CROSS-SECTION
SINGLE SPAN W/J-CHANNELS
J-CHANNEL @ WALL AND FASCIA END
SEE SHEET 2 FOR INSTALLATION
NOTES, FASTENER SCHEDULE AND
DESIGN PRESSURE PERFORMANCE
RATING TABLES. SEE SHEET 5 OR
DETAILS A, B, C & D.
NOTE 1: MINIMUM SPRUCE —PINE —FIR FRAMING @ 24" O.C. OR CONCRETE/MASONRY.
BUILDING CODE REQUIREMENTS FOR SUBSTRATE MATERIAL MUST BE MET.
CMU OR
WOOD
(NOTE 1)
C
a
m
4
�m
U
w
�r
u
€
�6
�0
a
ar
n�
a
V-�
of-
Rab J.Am—,P.E
Fb P.E.No.4WU
EAVE WIDTH
(ROOF
SPAN "L-
EAVE WIDTH
(ROOF
a
`m
4
—
—
�
�o
OVERHANG)
OVERHANG)o
ew
U
W
E
OF D
a
�w
HIM1
�VVNGKtIq
CMU OR
I
—CONCRETE,
CMU OR
_ ^
SOFFff
WOOD
1)
/
T SOFFIT
WOOD
yo
u e
"A" "
(NOTE
"
SEE DETAIL F" SEE DETAIL 'E"
(NOTE 1)
SEE DETAIL SEE DETAIL B"
EAVE CROSS-SECTION
EAVE CROSS-SECTION
SINGLE SPAN W/F-CHANNEL
SINGLE SPAN W/J CHANNELS
oao
a
F-CHANNEL @ WALL, FASCIA @ FASCIA END
3-CHANNEL @ WALL AND FASCIA END
a o
-L-
-L"
iG�o
a®f<
SPAN
SPAN
LL
�u oG
�§
EAVE WIDTH
EAVE WIDTH
^ v:
A 8
(ROOF
OVERHANG)
(ROOF
OVERHANG)
a
e "
ISI
Oz
�-
lig
CONCRETE,CONCRETE,
CMU OR
CMU OR
SOFFIT
(NOTE 1)
1)
SEE DETAIL "A" SEE DETAIL 'E"
JSOFFIT"(NOOTE
SEE DETAIL "F" SEE DETAIL B
EAVE CROSS-SECTION
EAVE CROSS-SECTION
Po[ j.M ..RE
WNURENo. 4UU
SINGLE SPAN W/J-CHANNEL
SINGLE SPAN W/F-CHANNEL
J-CHANNEL @ WALL, FASCIA @ FASCIA END
F-CHANNEL @ WALL, J-CHANNEL @ FASCIA END
SEE SHEET 2 FOR INSTALLATION NOTES, FASTENER SCHEDULE AND DESIGN PRESSURE
PERFORMANCE RATING TABLES. SEE SHEET 5 OR DETAILS A, B, E & F.
NOTE 1: MINIMUM SPRUCE -PINE -FIR FRAMING @ 24" O.C. OR CONCRETE/MASONRY.
BUILDING CODE REQUIREMENTS FOR SUBSTRATE MATERIAL MUST BE MET.
(b ,A
AC
.
0.G
Io
OSTAPLES INSTALLED O 24' O.C,
NA% (INTO WOOD) ON F-CHANNEL
LED OR T-NAL O 12' O.C. WJI
(INTO CONCRETE/MASONRY)
4.-1/8' MAX.
DETAIL A
FASCIA
DETAIL B
F-CHANNEL
O STAPLES INSTALLSD
e z4• D.c. D
fRA111',NC
7D
a
1/8'
FRAMING
OSfAP FS
7 O 24'
O
1)
DETAIL C
'--2%2 WOOD BATTEN@ J-CHANNEL
BATTEN TTA SCREW, 8
RSlALL ATTACHMENT
FASTENER SPACED 34' 9
MU FASTENER
7 fINO WOC
J-CNANNf
Oft T-N41
5 o.c. CONCRR
ETE
STAPLES IN
DETAIL D DETAIL E WOOD 1>
J-CHANNEL J-CHANNEL
FASCIA
NOTE 1: MINIMUM SPRUCE —PINE —FIR FRAMING ® 24" O.C. OR CONCRETE/MASONRY.
BUILDING CODE REQUIREMENTS FOR SUBSTRATE MATERIAL MUST BE MET.
APLES INSTALLED
O 12. O.C. MA%
(INTO WOOD) IN
J-CNWNILL SLOT
5 OR T-NAIL O 12
5 O.C. MA% ONTO
CDNCRME/NASON"
CONCRETE.
CMIJ OR
WOOD
(NOTE 1)
1/8" MAX.—.-I{—
DETAIL F
J-CHANNEL
FASCIA
WOOD BATTEN &
APLES INSTALLED
D 34• D.C. INTO O
FRANING
—/D • 3' WOOD SCREW 01
TAPING SCREW, BATTEN
ATTACHMENT FASTENER I
SPACED 24' LAX. O.C.
a
E
s
4
r
iy�
f-
W
i U
p W
�o
zb
a
d
H
¢F
�
RO AJ.A ...P.E.
HoWa P.E. Na 4915E
N
/
W
�JJ
a
fTl
DO
C
�
z
�
C
I
�
I
N
zo
of
m�
�z
c�ry
V /
OT
I
N
TI
co to N
P
D`
IT1 1
II^1I
\ l
O
�a
N
g
KAYCAN LTD
1 MEMORIAL DRIVE PROJECT #417-0614
P3
RICHFORD, VT05676
m b
NO. 639 VINYLSOFFIT INSTALLATION -SINGLE SPANS
SOFFIT PROFILE
Nm
�� RIA OL2N17
mw
'` scve N.T.S.x a A UPDATETOCURRENT ll2U]
MYN13 EDITION OF THE FBG
A t xtv
o
r'
z'
,18 .515 ,1B 5 0,793 w oo
RD,093 0.165 wo
a ar
2 .625 0. 5 "w
,7 5 775 0.818 95°6
4
R.156 L49� D,D42 0 0
D.D2 1,54 N oo
R0,156 0.04 15 =m a a
7es 71 1 /2" J—CHANNEL/TRIM N�
1, ,25—M 0,022
L VINYL (No. 1100) go,s�m�
1/2" F—CHANNEL/TRIM <'o'�°
w°€g
�U O.
VINYL (No. 1178) 4" FASCIA SMOOTH _p?z=
ALUMINUM (No. 9700) _� I�
o�
BILL OF MATERIALS
ITEM
DESCRIPTION
MATERIAL
SOFFIT —SEE SCHEDULE ON SHEET 1 AND DRAWINGS
ON SHEET
VINYLVIN
(SEE NOTE 1D ON SHEEP 1)
2
F—CHANNEL —SEE DRAWING ON SHEEP 6
3
J—CHANNEL —SEE DRAWING ON SHEEP 6
4
FASCIA —SEE DRAWING ON SHEEP fi
ALUMINUM
(SEE NOTE 10 ON SHEEP 1)
5
0.097" DIAMETER x 1-1/2' T—NAIL FOR CONCRETE AND
STEEL
r
4/24/2020
Florida Building
BCISHome I login I User Registration I Hot Topla I Submit5urchmge I 5'
d b
a
n "° Product Approval
9 USER; Public User
Eu�iv�kLLtm
• SHOPSTAMPREVIEW -91PW Lelia
Review Is for general compliance with the Construction Documents.
Responsibility for cooectness of dimensions, details, quantities and safety
during fabrication lies solely with the contractor.
N No Exceptions Taken Reviewed By. Dawn Boggio-Korbelak
❑ Rejected:
Ss & Facts I Publications I ContactUs I BCI5 site Mao I Links I Search I
4/28/20 !1 �_
LJdAn $.
Product &rroval Menu > Product or Application Search > Anolicatlen ❑st> Application Detail
FL #
FL21637-R6
Application Type
Revision
Code Version
2017
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived ❑
Product Manufacturer MI Windows and Doors
Address/Phone/Email 5S0 West Market Street
Gratz, PA 17030
(717) 365-3300 Ext 2560
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By Steven M. Urich, PE
G Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard Year
AAMA 506 2011
AAMA/WDMA/CSA 101/I.S.2/A440 2008
AAMA/WDMA/CSA 101/I.S.2/A440 2011
Equivalence of Product Standards
Certified By
Product Approval Method Method 1 Option A "VISION
ISION
Date Submitted 03/23/2020 JILE COPY
Date Validated 03/23/2020
Date Pending FBC Approval
https:/Avww.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgs9xV7TjKGeecQb2JXMWri1%2faFQMzcvxO%2bWWOJaumQ%3d%3d 113
4/24/2020 Florida Building Code Online
Date Approved 03/26/2020
Summary of Products
FL #
Model, Number or Name
Description
21637.1
1620 SH
48 x 84 Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16015.pdj
Approved for use outside HVHZ: Yes
FL21637 R6 C CAC APC 16054.Off
Impact Resistant: No
Quality Assurance Contract Expiration Date
Design Pressure: +45/-45
10/14/2021
Other: LC-PG50 Fin, LC-PG45 Finless/Flange
Installation Instructions
FL21637 R6 II 08-02998B.ppj
Verified By: Luis Roberto Lomas 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21037 R6 AE 513861B.pdf
Created by Independent Third Party: Yes
121637:
1620:SH
2 x 75 Insulated Glass
fUse
CertificationAgency Certificate
ed for'use in. HVHZ: No
F
(FL21637 R6 C CAC APC: 16016,
ed for: use outside HVHZ: Yes
(FL21637 R6 C'CAC APC 16055:ao
Resistant: No
Quality Assurance Contract Expiration Date
Design Pressure. +50 -50
10/14/2021
Other: LC-PG50
IInstallation Instructions
IFL21637 R6 Ii 08-02n99B.Rr'7f:
enfied By: Luis`Roberto Lomas 62514
Croated by Independent Third Party., Yes
rEval"ldcm:Reports)
!FQ3631 96-:8E`513862B:pd6
'Created. by Independent. Third Partynes
21637.3
1620 SH
37 x 72 Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16572.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
03/24/2022
Design Pressure: +50/-67
Installation Instructions
Other: LC-PG50
FL21637 R6 II 08-03042B.Oddf
Verified By: Luis Roberto Lomas 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 514078A.gdf
Created by Independent Third Party: Yes
21637.4
1620 SH
48 x 96 Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16574.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
03/24/2022
Design Pressure: +35/-45
Installation Instructions
Other: LC-PG35
FL21637 R6 II 08-03160A.gdf
Verified By: Luis Roberto Lomas 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 514079A odf
Created by Independent Third Party: Yes
21637.5
1620 SH Impact
38 x 75 Fin and Finless Frame, Insulated, Laminated Glass.
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC(1814311820.05-106-12-R1 1620
5HH(051523j,gQj
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Quality Assurance Contract Expiration Date
Design Pressure: +50/-70
OS/15/2023
Other: LC-PG50, Missile Level D, Wind Zone 3, glass was
Installation Instructions
bedded In Pecora 896 silicone.
FL21637 R6 II 08-03454A.odf
Verified By: Luis R. Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 514467A.odf
Created by Independent Third Party: Yes
21637.E
1620 SH Impact
52 x 75 Insulated Laminated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16230.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
https:IAw .floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQwtDgsgxV7TjKGeecQb2JXWyWri1%2faFQMzcvxO%2bv,MOJaurm4%3d%3d 2/3
4/24/2020 Florida Building Code Online
Impact Resistant: Yes 12/27/2021
In Design Pressure: +50/-50 stallation Instructions
Other: LC-PG50, Missile Level D, Wind Zone 3. Glass consisted FL21637 R6 II 08-03042B.pdf
of 1/8" annealed exterior - spacer - 3/32" annealed / 0.090 Verified By: Luis Roberta Lomas 62514
PVB / 3/32" annealed. Glass was bedded in Pecora 896 silicone. Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 513921B.pdf
Created by Independent Third Party: Yes
Back Nevt
Song:: 2601 Blair Stone Road Tallahassee Fl. 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer _gopyyh[ 2o0J-2013 State oP Floritla.:: Prlvacv Statement :: Accesslbllity Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a publle-records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questtans, please contact SS0.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address If they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which on be made avallable to the public. To determine If you are a licensee under Chapter 455, F.S., please click hem .
Product Approval Accepts:
R ® ® xlarA M
SecuritymbTRICS, �.
https:/Aw .floridabuilding.org/pr/pr app_otl.aspx?param=wGEVXQwtDgs9xV7TjKGeecQb2JXNyWri1%2faFQMzcwO%2bVvWOJaurmQ%3d%3d 313
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville NC, 27023
434-688-0609
rllomm@)rlommpe.com
Manufacturer: MI Windows & Doors, LLC
650 West Market Street
Gratz, PA 17030-0370
Engineering Evaluation Report
Product Line: Series 1620 PVC Single Hung — Reinforced Non -Impact 52"x75"
Report No.: 513862B
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed
herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation:
1. Approval documents: drawing numbers 08-02999 Revision B, prepared, signed and sealed by Luis Roberto
Lomas P.E.
2. Report No.: G1 516.03-109- 47 signed by TimothyJ. McGill
Architectural Testing, Inc., York PA.
AAMA/WDMA/CSA 101/I.S.2/A440-08
Design pressure: ±50.13psf
Water penetration resistance 7.52psf
3. Report No.: G1519.03-109-47 signed by Timothy J. McGill
Architectural Testing, Inc., York PA.
AAMAM/DMA/CSA 101/I.S.2/A440-08
Design pressure: t50.13psf
Water penetration resistance 7.52psf
4. Anchor calculations, report number 513862-1 B, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: t50.Opsf
• Unit size: 52 1/8" x 75"
• Units must be glazed per ASTM El300-04/09.
• This product is not rated to be used in the HVHZ.
• This product is not impact resistant and requires impact protection in wind borne debris regions.
• Frame material to be Rigid PVC.
Installation:
Units must be installed in accordance with manufacturers installation instructions and approval documents, 08-02999,
Revision B.
Certfrication of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
1 of 1
TAT DF ,•w
��'o•'.R.ORIO? • mil'
/Zss�IIVALIE������
Luis R. Lomas, P.E.
FL No.: 62514
01/16/2020
(Validator I Operations Administrator)
MI Windows & Doors, LLC
P.O. Box 370
Gratz, PA 17030-0370
Attn: Rick Sawdey
AAMA
CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an
AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory.
SPECIFICATION
RECORD OF PRODUCT TESTED
AAMAANDMAICSA 1011I.S.21A440-08
LC-PG50-1324x1905 (52x75)-H
COMPANY AND CODE
CPD NO.
SERIES MODEL & PRODUCT
MAXIMUM SIZE TESTED
DESCRIPTION
1620 SH (FINLESS & FLANGE)
FRAME
SASH
MI Windows & Doors, LLC
16055
(PVC)(O/X)(OG)(INS GL)
1324 mm x 1905 man
1257 mm x 946 mm
Code: MTL
(MODIF)(REINF)(TILT)
(4'4" x 6'3")
(4'2" x 3'1")
(ASTM)
This Certification will expire October 14, 2021 and requires validation until then by continued listing in the current AAMA Certified
Products Directory.
Product Tested and Reported by: Intertek-ATI
ReportNo.: G1519.03-109-47
Date of Report: November 3, 2016
JGS/JTS
ACP-04 (Rev.6/11)
Evaluated for Certification: November 8, 2016
A
A( ted Laboratories, Inc.
Authorized for Certification: November 8, 2016
ArnericariNkhitectural Manufacturers Association
. (Validator/ Operaflons Administrator)
MI Windows & Doors, LLC
P.O. Box 370
Gratz, PA 17030-0370
Attn: Rick Sawdey
AAMA
CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an
AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory.
SPECIFICATION
RECORD OF PRODUCT TESTED
AAMAIWDMA/CSA 101/I.S.2/A440-08
LC-PG50-1324x1905(52x75)-H
COMPANY AND CODE
CPD NO.
SERIES MODEL & PRODUCT
MAXIMUM SIZE TESTED
DESCRIPTION
1620 SH (FIN)
FRAME
SASH
MI Windows & Doors, LLC
16016
(PVC)(O/X)(OG)(INS GL)
1324 mm x 1905 mm
1257 rrm x 946 mm
Code: MTL
(MODIF)(REINF)(TILT)
(4'4" x 6'3")
(4'2" x 3'1")
(ASTM)
This Certification will expire October 14, 2021 and requires validation until then by continued listing in the current AAMA Certified
Products Directory.
Product Tested and Reported by: Intertek-ATI
Report No.: G1616.03-109.47
Date of Report: October 27, 2016
JGS/JTS
ACP-04 (Rev.6/11)
Evaluated for Certification: November 1, 2016
,h, /1
A ocl ted Laboratories, Inc.
Authorized for Certification: November 1, 2016
Americaactural Manufacturers Association
NOTES:
7. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL:. EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE
DEBRIS REGIONS.
14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE $6 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
TABLE OF CONTENTS
SHEET N0. DESCRIPTION
NOTES
2 — 3 ELEVATIONS
4 —16 INSTALLATION DETAILS
17 COMPONENTS
RENSIONS
REV OESCN11110N WE MPROVEO
A REVISED ANCHORS 22/27/18 R.L.
B ADDED NEW EXTRUSIONS 01/16/2020 R.L.
15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE $6 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
16. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #B WOOD
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO
SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
17. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/15" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
18. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE b8 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS:
19. ALL FASTENERS TO BE CORROSION RESISTANT.
20. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF 0=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2.000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR
ALUMINUM 6063—T5 FU=30KSI 1/8" THICK MINIMUM
21. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS
SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN
IN SHEET 2.
SIGNED: OT/28/2020
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
NOTES
sa1E NTS WE 11/30/16 OS s ET 99 OF 17 B SI/1111110a\\\``.
L. ROBERTO LOWSP.E. Luis R. Lomas P.E.
1432 WOOORORO RD LEWISVIILE, NO 21023 FL NO.: 62514
434-666-0609 rffwnas(dlrlomasm.mm
FIR
HE
r 52 1/8" FRAME WIDTH —
1
4" MAX
l
12" MAX
D.C.
5"
WE
GHT
L
a" MAx
O /
4 �
52 1/8" FRAME WIDTH —
4" MAX
12" MAX
O.C. O /
n
7$
FRAME
HEIGHT /
J
4" MAX
RFASIONS
PEV pESCRIPiION M1E APPROVED
A REVISED ANCHORS 02/D/18 R.L.
B ADDED NEW EMUSION5 1 01/16/20201 R.L.
chart#[
Number of anchor locations required
Frame
Frame Width
(in)
Helght
(ln)
24.00
Heatl
Jamb
30.00
Head
Jamb
36.00
Head
1 42.00
Head
1 46.00
Head
Jame
1 SZ13
Head
Jamb
24.00
3
3
3
3
4
5
3
5
3
30.00
3
3
3
3
4
5
3
5
]
]6.00
3
4
3
a
4
s
a
s
a
4200
3
4
3
4
4
5
4
5
4
46.1a
3
5
3
5
a
g74
5
5
5
5
54.00
]
5
3
5
a
5
5
5
5
60.00
3
6
3
0
a
5
6
5
6
66.00
3
6
3
6
a
5
6
5
6
72.00
3
7
3
7
4
5
7
5
7
75.00
3
7
3
T
4
5
7
5
7
1620 SH REINFORCED FOR NUMBER 1620 SH REINFORCED
` FOR NUMBER
RECTANGULAR
OF ANCHORS DESIGNER
OF ANCHORS
EXTERIOR VIEW
REQUIRED EXTERIOR VIEW
SEE CHART #1
REQUIRED
SEE CHART #1
FNLESS 6 FLANGE INSTALLATION
FINLESS 6 FLANGE INSTALLATION
DESIGN PRESSURE RATING IMPACTRA77NG
350.0PSF NONE
5212'X75' UNITSHOWN.OTHER SIZESAPPROVEDAS LONGAS
FRAMEAREA DOES NOTEXCEED27.14'Fl
SIGNED: 0112812020
LC.
MI WINDOWS50WESMAR
N%X`\\\\\511R IIL
NOTES:
ET STREET
O1f7j7/i
O . q i
GENE
L SASH SIZE:
GRATZ. PA 17030-0370
4912'X371/4'
2. D.LO.:4712'X33374'
SERIES 1620 SH REINFORCED
p*• 0 66a7/�ta'tO�*'.
NON —IMPACT 52 1/8" X 75"
FINLESS & FLANGE ELEVATIONS
E •C
;y, TAT OF ty`
HARDWARE SCHEDULE
pwc No.
�0�4• A.
Rw i��F.S, [OR1OP G�e�C
) CAM LOCK, 7" FROM EACH CORNER AT TOP RAIL OF SASH
TILT LATCH AT TOP RAIL OF SASH, AT EACH CORNER
08502999
B ii7jS/pNA11g\�\�J
)COIL BALANCES AT SASH POCKET OF JAMBS
iE 11/30/16 2 OF 17
E102
LMINUM REINFORCEMENT (AE-000162) AT MEETING RAIL
L ROSERTO LOWS P.E.
AMINUM REINFORCEMENT)MQ715) AT LOCK RAIL
wOODPoRO RO LEWI3wuE, NC z7023
Luis R. Lomas P.E.
FL No.: 62514
-UMINUMREINFORCEMENT(M-2266)ATSTILES
34666066g Wamas®4lomaspe.mm
7
FIR
HE
3" MAX
I
3 MAX
8" MAX O.C.
5"
%ME
GHT
3" MAX
52 1/8" FRAME WIDTH —
MAX 3" MAX — S" MAX O.C. — 3" MAX
FOR NUMBER FOR NUMBER
OF ANCHORS OF.ANCHORS
REQUIRED REQUIRED
SEE CHART #2 SEE CHART j{2
3" MAX_
8" MAX O.C. O /
75"
FRAME
HEIGHT
1620 SH REINFORCED
RECTANGULAR
EXTERIOR VIEW
FIN INSTALLATION
DESIGNPRESSURERATING IMPACTRATING
t50.0PSF NONE
52lM'X75' UNIT SHOWN OTHER SOESAPPROVEDAS LONGAS
FRAMEAREA DOES NOTEXCEED 27.14'M
NOTES:
1. MAXIMUM SASH SIZE. 4912'XS71/4'
2. MAXIMUM D.LO.: 47 la'X333/4'
J
X
4
0�
1620 SH REINFORCED
DESIGNER
EXTERIOR VIEW
FIN INSTALLATION
RE SlONS
OESCRIona N 1 WE Acf` MD
REVISED ANCHORS 1 02/27/18 R.L.
ADDED NEW EXTRUSIONS 1 01/16/20201 R.L.
COarI C2
Number of anchor Immune ne required
Frame
Flame Width (in)
14'I901
(in)
2400
HAS
Jamb
]0.00
H65
Jamb
]&00
HAS
Jamb
4200
HAS
Jamb
I8.00
H65
Jamb
52.13
IHIS
IJamb
24.00
a
a
4
4
5
4
6
4
T
4
T
4
]0.00
4
4
4
4
5
4
6
4
T
4
]
4
38.00
4
5
4
5
5
5
6
5
T
5
T
5
4ZOD
tr
8
4
0
5
6
6
6
T
48.00
d
T
4
]
5
7
6
7
7
"..as
d
T
4
]
5
T
B
T
T
60.00
6
B
4
8
5
B
6
0
T
Md
66A0
4
S
4
9
5
9
B
9
7
72.00
6
10
4
10
5
10
0
1D
T
Aram
4
1D
4
10
5
10
6
10
7
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 162D SH REINFORCED
NON —IMPACT 52 1/B" X 75"
FIN ELEVATIONS
MWN: [AG NO.
R.L. OB-02999
SCAB NTS ID"TE 11/30/16 SHEU3 OF 17
L ROBERTO LOWS P.E.
I Q32 W0ODFORD RD LEWISVILE NC 2=
43 8-0609 Nams®hbmmspa.mm
aaaaaaaaa
SIGNED. 0112812020
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
I
1/4" MAX.
SHIM SPACE
HEAD TO BE SET
IN A BED OF
APPROVED SEALANT
INTERIOR
N-5
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BVCKINSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWN FOR CLARITY.
2 PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCEWITHASTM E2112
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1/4" MAX.
HIM SPACE
1 1/4" MIN.
EMBEDMENT
7/16" MIN.
EDGE DISTANCE
#B WOOD
SCREW
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
flM510N5
REV O6 RIPTION MlE gPPROVEU
A REVISED ANCHORS 02/2J/18 R.L.
B I ADDED NEW EXTRUSIONS 1 01/16/20201 R.L.
1/4" MAX.
SHIM SPACE
NTERIOR
EXTERIOR
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCKINSTALLATION
MI WINDOWS & DOORS, LLC.
65D WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 162G SH REINFORCED
NON —IMPACT 52 1/8" X 75"
FINLESS INSTALLATION DETAILS
DR N: DWG NO.
R.L. 08-02999
NTS IWE 11/30/16 ISNEF4 OF 17
L.ROBERTOLOMASP.E
M2WO0DF0RD RDIEWISVILLE, NC2T023
A34686d609 rllomas(JNamazre.rom
SIGNED: 01/28/2020
Luis R. Lomos P.E.
FL No.: 62514
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
1/4- MAX.
SHIM SPACE
HEAD TO BE SET
IN A BED OF
APPROVED SEALANT
O
EXTERIOR
�pa
o
v
INTERIOR
Ia
L
O
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
BACKER ROD O
& APPROVED �J
SEALANT ❑ _� 1/4" MAX. SHIM
SPACE
METAL
STRUCTURE
BY OTHERS
VERTICAL CROSS SECTION
METAL STRUCTUREINSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOSE
DESIGNED INACCORDANCE WR ASTM E2112
RrnsIONs
Rfl' DERCIDPROM MlE APPROVED
A REVISED ANCHORS 02/2T/1I R.L.
B ADDED NEW EXTRUSIONS 01/16/2020 R.L.
1/4" MAX.
SHIM SPACE
7/15" M�
EDGE
DISTANCE
INTERIOR
#B SMS OR IJL 1 E
SELF DRILLING
SCREWS
EXTERIOR
METAL
STRUCTURE BACKER ROD
BY OTHERS & APPROVED
SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTUREINSTALLA77ON
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
FINLESS INSTALLATION DETAILS
DK NO.
08-02999
NTS I -E 11/30/16 S.EU5 OF 17
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
CONCRETE/MASONRY
BY OTHERS
. 4
OPTIONAL 1X BUCK- a-
SEE NOTES 3 — 7 `
SHEET 1
I
BACKER ROD `emu u
& APPROVED 1/4 MAX.
SEALANT SHIM SPACE
HEADTO BE S�
N BED OF
APPROVED SEALANT
®®
=❑
EXTERIOR
0 0 0
(�
INTERIOR
�
o
SILL BE SET
BACKER ROD
B
IN A BED OF
& APPROVED
APPROVED SEALANT
SEALANT
0 1/4" MAX.
OPTIONAL 1X BUCK
SEE NOTE 3 — 7
4q
❑
SHIM SPACE
SHEET i
CONCRETE/MASONRY
BY OTHERS
_
_.a..
_
- -
e
a _ _
a.
VERTICAL CROSS SECTION
CONCRETEMASONRY INSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARITY.
2. PERIMETER AND JOA?SEALANTBYOTHERS TO BE
DESIGNED INACCORDANCE WIMASTM E2112
1 1/4" MIN.
EMBEDMENT
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK > -
SEE NOTES 3 — 7
SHEET i
RMSIONS
REV OESCRIPiION pp1E pPPROVEO
A REVISED ANCHORS 02/27/Is R.L.
B I ADDED NEW EXTRUSIONS 1 01/16/2020 R.L.
1/4" MAX.
SHIM SPACE
INTERIOR
MIN.
EDGE
0
M D
DISTANCE
o
EXTERIOR
BACKER
ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
CONCRETEMASONRY INSTALLATION
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/B' X 75"
FINLESS INSTALLATION DETAILS
)MM On N0.
R.L. 08-02999
'�E NTS °°TE 11/30/16 5xEET6 OF 17
03P-68&0609
REV
B
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
I
BACKER ROD SHIM & APPROVED
HEAD TO BE SET
IN A BED OF
APPROVED SEALANT
0
a® Cam❑
EXTERIOR INTERIOR
O
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCKINSTALLATION
NOTES:
1. INTERIORAND EXTERIOR KNISHES, BYOTHERS,
NOTSHOWN FOR CLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WRHASTM E2112
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1/4" MAX.
HIM SPACE
RMSIONS
DMORI"OK W.1E MPROVED
REVISED ANCHORS 02/27/18 R.L
ADDED NEW EXTRUSIONS I 01/16/2D20R.L.
1 1/4" MIN.
EMBEDMENT
SHIM SPACE
1/4" MAXIF.
I
INTERIOR
7/16" MIN.
�„
EDGE DISTANCE
P=9_
#B WOOD �l e
SCREW 0
WOOD FRAMING W
OR 2X BUCK EXTERIOR
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
SIGNED: 0112812020
MI ID WOWS LC
6 WEST MARKET
ET STREET
``���\S
GRAB. PA 17030-0370
'`may •y�GENyF'pji�y
��••10,.6126 *_
SERIES 1620 SH REINFORCED*.•pN
NON —IMPACT
1ON X 7IL
LL
FLANGE INSTALLATION DETAILS
' S
�g1 TAT OF y�
i0 P ,i
0w0 No.
R.L.ORM
OB02
B
i11NAL1E�G``�
Luis R. LORI06 P.E.
FL NO.: 62514
NTS DATE 11/30/16 5L97B OF 17
LROBERTOLOMASP.E
13WDFORD RD LEWISVILUE. NC 229
S1-09
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
BACKER ROD
& APPROVED
SEALANT
METAL
STRUCTURE
BY OTHERS
1/4" MAX.
SHIM SPACE
TO BE SET
IN A BED OF
APPROVED SEALANT
INTERIOR
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE W17HASTME2112
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1/4" MAX.
SHIM SPACE
REVS10uS
D=RI?V0N DATE I APPROVED
REVISED ANCHORS 02/27/18 1 R.L.
ADDED NEW EXTRUSIONS 1 01/16/20201 R.L.
1/4" MAX.
SHIM SPACE
7/16" MIN. INTERIOR
EDGEG
DISTANCE
#8 SMS OR J
SELF DRILNG
SCREWS �� D
METAL EXTERIOR
STRUCTURE BACKER ROD
BY OTHERS & APPROVED
SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCNRE INSTALLATION
SIGNED: 0112812020
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
FLANGE INSTALLATION DETAILS
DRAWN: 0WC NO,
R.L. 08-02999
WALE NTS IDATE 11/30/16 Is EETB OF 17
IG32WOODFW{O flD LEWISYILL£, NO 21023 I Luis R. Lomas P.E.
<sN�seaae0s mwne:®mwname.cwn FL No.: 62514
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK
SEE NOTES 3 - 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
a
nn
1/4" MAX.
oEL
SHIM SPACE
O
HEAD TOSET
N A BEE OF
OF
IIIIII
APPROVED SEALANT
RMSIONS
REV DMCRIPDON WE APPROVED
A REVISED ANCHORS 02/2T/18 R.L.
B ADDED NEW EXTRUSIONS 1 01/16/2020R.L.
1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK °
SEE NOTES 3 - 7
SHEET 1
INTERIOR
3/16" TAPCON
INTERIOR C e
�.a
SILL TO BE SET
BACKER R00
IN A BED OF
& APPROVED
APPROVED SEALANT
SEALANT
O 1/4" MAX.
O�SHIM
OPTIONAL 1X BUCK
SEE NOTE 3 - 7
_
o SPACE
4LZ
SHEET 1
CONCRETE/MASONRY
BY OTHERS4.
a
VERTICAL CROSS SECTION
CONCRETFJMASONRY INSTALLAT70M
NOTES'
1. INTERIORAND EXTERIOR FINISHES, BY07HERS,
NOTSHOWN FOR CLARITY.
2. PERIMETERANOJOINTSEALANTBYOTHERSTOBE
2" �❑
MIN. O
EDGE
DISTANCE ° EXTERIOR
BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
CONCRETEMASONRYINSTALLATION
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
FLANGE INSTALLATION DETAILS
DRAwR: Dwc W.
R.L. 08—D2999
SME NTS I DATE 11/30/16 sREET9 OF 17
L. ROBERTO LOWS P.E.
14 IM30DMRD RD LEWISVILLE, N027=
C 6664?609 Nomns>Nanazp .
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
MAX.
I SPACE
HEAD TO BE SET
IN A BED OF
APPROVED SEALANT
O
q® Cam❑
EXTERIOR q INTERIOR
v a a
� o
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOT SHOWN FOR CLARITY.
Z PERIMETERANDJOIATSEALANTBY OTHERS TORE
DESIGNED IN ACCORDANCE WRH ASTM E2112
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
/4" MAX.
HIM SPACE
REVISIONS
REV DESCRIPRON pgtE MPRa D
A REVISED ANCHORS 02/27/18 R.L.
B ADDED NEW EXTRUSIONS Ol /16/2020 R.L.
1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
I INTERIOR
7/16" MIN.
EDGE DISTANCE
$B WOOD J 9111�
SCREWWOOD FRAMING OR 2X BUCK� EXTERIOR
BY OTHERS
BACKER ROD
& APPROVED JAMB INSTALLATION DETAIL
SEALANT WOOD FRAMING OR 2XBUCKINSTALLA770N
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
FLANGE INSTALLATION DETAILS
CRnwN: U.G N0.
R.L. 08-02999
SCALE NTS o`TE 11/30/16 IS.EETJG OF 17
SIGNED: 0112MO20
Luis R. Lomas P.E.
FL No.: 62514
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
lea X � �i ■
r�. q�
1/4" MAX.
SHIM SPACE
TO BE SET
BED OF
OVED SEALANT
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
BACKER ROD
& APPROVED
SEALANT 1/4• MAX.
SHIM SPACE
METAL
STRUCTURE
BY OTHERS
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARRY.
2 PERIMETERANDJOIMSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WITHASTM E2112
RE SION5
D ESCRIGIION 611E MpRGVEO
REVISED ANCHORS 02/27/18 R.L.
ADDED NEW EXTRUSIONS I DI/16/20201 R.L.
�I 1/4" MAX.
7/1SHIM SPACE
INTERIOR
6" MIN.
GE
DISTDANCE
#8 SMS OR J �uJ�
SELF DRILLING
SCREWS O fl EXTERIOR
METAL _:
STRUCTURE BACKER ROD
BY OTHERS & APPROVED
SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
SIGNED: 0112812020
MI WOW5I0NDEST
MAR ET S REETLC
GRATZ, PA 17030-0370
` r•. \DENS
\ l -
D6 *;
SERIES 1620 SH REINFORCED*•
NON —IMPACT 52 1/8" X 75"
FLANGE INSTALLATION DETAILSSTATE
OF •t�
i0.
iF ;�[OR1DQ;•�@��
owc NO.
RLv
R.L.
08 BB
B
�Z7AL/rjs10HA11�?G\��
iLLLE oaTE sDLLT
NTS 11/30/16 ll OF 17
LOIS R. LOR1D5 P.E.
FL No.: 62514
LROBERTOLOWSPE.
f0. WOODFORDRDLEWISWLLB,NO27023
<SL&6609 Nanaz[a>Nomaspe.mm
CONCRETE/MASONRY —�
BY OTHERS
OPTIONAL 1X BUCK
SEE NOTES 3 — 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
Q' a
I
1/4" MAX.
I��II
ovLl
SHIM SPACE
0
HEAD TOSET
OF
IN A BEE OF
Illill
APPROVED SEALANT
INTERIOR
BACKER ROD SILL B BE SET
& APPROVED IN A BED OF
SEALANT APPROVED SEALANT
E3 1/4- MAX.
OPTIONAL 1X BUCK SHIM SPACE
SEE NOTE 3 7 4q
SHEET 1
CONCRETE/MASONRY
BY OTHERS
4 a.
VERTICAL CROSS SECTION
CONCREIIEWSONRYINSTALLATION
NOTES:
1. INTERIORAND EXTERIOR RNISHES, BYOTHERS,
NOTSHOWNFORCLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCEWITHASTM E2112
REASIORS
DMCRI"ON wE I MPRWEO
REVISED ANCHORS 02/27/18 1 R.L.
ADDED NEW EXTRUSIONS 1 01/16/2020 R.L.
1 1/4" MIN.
EMBEDMENT
CONCRETE/MASONRY
ea ,
BY OTHERS
OPTIONAL 1X BUCK
SEE NOTES 3 — 7 1
1/4" MAX.
SHEET 1
.°
SHIM SPACE
INTERIOR
3/16" TAPCON
•_
a
!C_rl'
MIN. EDGEDISTANCE
°TERIOR
ROD
BACKER
&
APPROVED
JAMB INSTALLATION DETAIL
SEALANT
CONCRETHMASONRY INSTALLATION
SIGNED: 0112812020
MI WINDOWS LC
T MAR ET STREET
`\`\`\SIII�111C(O A77,
GRATZ, PA 17030-0370
y •��C EN9�.'9j+
z*-• �101,51?$1 *_
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
�•��{/�n _
FLANGE INSTALLATION DETAILS
�p �• $$TAT OF rV�
�'�• FCORIDQ:•��
DRAWN:
owe u0.
RLv
08
LNIS R. Lom.s P.E.
FL No.: 62514
5E NTS — 11/30/16 sx0 64EE112 OF 17
LROBERTOLOMASP.E.
1432WOODFORDROLEWISVILLENC2023
434ti 609 Nwnas@NDmagiR.com
APPROVED
SEALANT
BEHIND FIN
#6 WOOD
SCREW
3/8- MIN
EDGE DISTANCE
-.i.
�J X to I� ■
• � LK f Lq�
3/8" MIN J
EDGE DISTANCE
#6 WOOD
SCREW
APPROVED
1 1/2" M
EMBEDMEI
SEALANT
BEHIND FIN
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCKINSTALLITION
NOTES:
f. INTERIORAND EXTERIORFINISHES, BYOTHERS,
NOTSHOWN FOR CLARITY.
R. PERIMETERANDJOINTSEAIANTBYOTHERSTOBE
DESIGNED IN ACCORDANCE WITH ASTM E2112
WOOD
-RAMING
3Y OTHERS
1/4" MAX.
SHIM SPACE
WOOD FRAMING
BY OTHERS
#6 WOOD
SCREW
1 1/2-
MIN.
EMBEDMENT
REASIONS
REV DMRIPTION 27/ R.I.
NOAD
A REVISED ANCHORS 02/]18 R.L.
B ADDED NEW EXTRUSIONS 1 01/15/2020 R.L.
1/4" MAX
SHIM SPACE
INTERIOR
APPROVED ��D
SEALANT
BEHIND FIN
3/8" MIN EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCKINSTALLATION
1/4" MAX
SHIM SPACE
WOOD
FRAMING MI WINDOWS & DOORS, LLC.
BY OTHERS 650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
NON -IMPACT 52 1/8" X 75"
FIN WITH J CHANNEL INSTALLATION DETAILS
R.L W DW NO.
R.L. 08-02999
SALE NTS DATE 11/30/16 s'a 13 OF 17
t. ROSERTOLOMAS RE
1492 WDODROAD RDLEWISVILLE NC27O2i
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
APPROVED
SEALANT
BEHIND FIN
#6 SMS OR
SELF DRILLING
SCREW
3/8" MIN
EDGE DISTANCE
RENSIONS
REV DESCRIPRON pgiE APPROVED
A REVISED ANCHORS 02/27/18 R.L.
METAL STRUCTURE B ADDED NEW EXTRUSIONS 01/15/2020 R.L.
BY OTHERS
1/4" MAX.
SHIM SPACE
1/4" MAX
SHIM SPACE
1/4" MAX
SHIM SPACE
METAL STRUCTURE
BY OTHERS
NTEflIOfl
$6 SMS OR
SELF DRILLING
SCREW
APPROVED
SEALANT
BEHIND FIN
EX ERIOA
3/8" MIN _
EDGE DISTANCE
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
3/8" MIN
EDGE DISTANCE
'6 SMS OR
METAL STRUCTURE
SIGNED: 0112812020
SELF DRILLING
BY OTHERS
MI WINDOWS & DOORS, LLC.SCREW
�11111HNrrr7A
STRUCTURE INSTALLATION CROSS SECTION6GRATZS
50
PA 170 0 0370WET MARKETT
��y�\�NG
APPROVEDZt.�v'TALICAL
SEALANT
BEHIND FIN
SERIES 1620 SH REINFORCED*�
per$ *t
NON —IMPACT 52 1/8' X 75"
FIN WITH J CHANNEL INSTALLATION DETAILS
pO�• -$7pT OF W`
NOTES:
0IN: owc uo.
REv %"FS:°GORIOP; G� �O
1. INTEMORANDFINISHES, BYOTHERS,
08 50EE999
B �ONALIE�X���
NOTSHWNFOFCLAIOR
sGLE DATE
NTS 11/30/16 14 OF 17
2. PERIMETERANDJOINTSEALANTBYOTHEns TOBE
DESIGNED INACCORDANCE WITHASTM E2112
L ROBERTO LOWS P.E.
149E WOODFORD RD LEWISVILLE, NC27W3
Luis R. Lomas P.E.
464-680D609 iLbrnes@I4wnespR.com
FL NO.: B2514
APPROVED
SEALANT
BEHIND FIN
#6 WOOD
SCREW
3/8" MIN
EDGE DISTANCE
tm
�[, IG ■
3/8" MIN
EDGE DISTANCE
$6 WOOD
SCREW
APPROVED
1 1/2" M
EMBEDMEI
SEALANT
BEHIND FIN
VERTICAL CflOSS SECTION
WOOD FRAMING OR2X BUCK INSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWN FOR CLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOSE
WOOD
FRAMING
BY OTHERS
1/4" MAX.
SHIM SPACE
1/4" MAX
SHIM SPACE
WOOD
FRAMING
BY OTHERS
RMSIDNS
OESCRNTION pgTE APPRWED
REVISED ANCHORS 02/27/18 1 R.L.
ADDED NEW EXTRUSIONS 1 01/16/20201 R.L.
_ 1/4" MAX
SHIM SPACE
WOOD FRAMING
BY OTHERS
j�6 WOOD INTERIOR
SCREW
1 1/2" Liuo
MIN.
EMBEDMENT - !nHo'o
APPROVED SEALANT O
BEHIND FIN
3/8" MIN EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
SIGNED: 0112812020
fvil WINDOWS
KETLO.
IIf10
0SMARSTREET
51IR
GRATZ, PA 17030-0370
ENS :%p
R•
*• D 5 =
SERIES 1620 SH REINFORCED
NON -IMPACT 52 1/8" X 75"
��KM.�+
T
FIN INSTALLATION DETAILS
�p OF
'
�'OFs:;ORI�Q:
DR.L.:
owc No.
Rlv
SCALE
08
B
O3eS�
/X7jSIQNA11EaAA��
LUiF9L NoLoi0551P.E.
624
NTS WTE 11/30/16 SHEET 15 OF 17
LROSERTOLOMASP.E
12WOODORDRDLEWISVILENC2)
404-66"609
APPROVED
SEALANT
BEHIND FIN
#6 SMS OR
SELF DRILLING
SCREW
3/8" MIN
EDGE DISTANCE
CIIIII i �
J rid, IGI ■
3/B" MIN CEJ
EDGE DISTAN
#6 SMS OR
c
SELF DRILLING
SCREW
VERTICAL CROSS SECTION
APPROVED
METALSTRUCTUREINSTALLATION
SEALANT
BEHIND FIN
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WITHASTMF2112
METAL STRUCTURE
BY OTHERS
1/4" MAX.
SHIM SPACE
1/4" MAX
_F SHIM SPACE
METAL STRUCTURE
BY OTHERS
RMSIONS
DESCRIPTION I — I APPRWEO
REVISED ANCHORS 1 02/27/18 R.L.
ADDED NEW EXTRUSIONS 01/16/2020R.L.
_ 1/4" MAX
r METAL STRUCTURE SHIM SPACE
6V OTHERS
INTERIOR
#6 SMS OR
SELF DRILLING
SCREW
APPROVED
SEALANT
BEHIND FIN
3/8" MIN EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
METAL STRUCTUREINSTALLATION
SIGNED: 0112812020
MI OSR LC.
SI�NDOWWEST MARKET REST
.`may
GRATZ. PA 17030-0370
.yNGENS�N�
*• DA,5�51 *1
:.[d+
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
FIN INSTALLATION DETAILS
O: STATE OF •sV`
DIM.w:
Dwc xD.
aM
08
8
IOIIIAl110N`\``
W16 R. Lomas P.E.
502E996 OF 17
s�E NTS wTE 11 /30/16
L ROSERTO LOMAS PP.
I432 WOOOFORD RD LEWISVILLP, NO 21
d 1G 6R 09 Nomas@IrlmmazPs.com
FL No.: 62514
060
2 5/16" rI_JI
1-�qp�4
HEAD/JAMB FINLESS
EXTRUDEDPVC(114006)
3333/16" —
S
3 13/16" Im—mpoQl�
LT �
HEAD/JAMB FIN INSTALLATION
EXTRUDED PVC (V-1007)
3 1
7/6�IGf�7
—STILES
REINFORCEMENT
ALUMINUM 606345 (M-2266)
3 1/4" —I
0 1/8-
SILL FINLESS
EXTRUDED PVC (V.1013)
SILL FIN INSTALLATION
EXTRUDED PVC (V.1012)
WITH J-CHANNEL
EXTRUDED PVC (V-1011)
l 3/4"
F
MEETING RAIL
REINFORCEMENT
ALUMINUM 6063-T5 (AC 000162)
'8"
3 3/16"
2 13/16"
HEAD/JAMB WITH FLANGE
EXTRUDED PVC (V.1010)
3 1/4"
2 13/16" l m I51
emu_ _0-
HEAD/JAMB WITH FLANGE
EXTRUDED PVC (VE-000025)
1 1/4"
B.. H
1 3/4"
L
BOTTOM SASH/STILE
EXTRUDED PVC (V-670)
I--r 15/16°
1/2" lul
LOCK RAIL
REINFORCEMENT
ALUMINUM 6063-T5 (M-2115)
r--1 15/16"
LS LL-IJ
OPERABLE SCREEN
�Glll�xe>♦
ALUMINUM 6063-T5 (M-2341)
DESCRIPTION
REVISED ANCHORS
ADDED NEW EXTRUSIONS
SILL WITH FLANGE
EXTRUDED PVC (V-1015)
3 1/4"
oCe"
SILL WITH FLANGE
EXTRUDED PVC (VE-000021)
p❑ 2 3/16"
MEETING RAIL
EXTRUDED PVC (V-1016)
MI WINDOWS & DOORS, LL
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
NON —IMPACT 52 1/8" X 75"
COMPONENTS
RMSIONS
041E APPR-0
02/27/18 1 R.L.
O1/16/2020 R.L.
2
1 3/4"
BOTTOM SASH/TOP RAIL
EXTRUDED PVC (V-675)
— 1 3/4" r
31
o 1
BOTTOM SASH/BOTTOM RAIL
EXTRUDED PVC (V-672)
GLAZING NG BEAD
RIGID PVC (V-904)
SIGNED: 0112812020
!R. L�08-02999 1_102999 1_1
�FA' NTS 1" 11/30/16 5REU 17 OF 17NTS 1" 11/30/16 5REU 17 OF 17
Luis R. Lomas P.E.
FL No.: 62514
4124/2020 Florida Building
KQRDADRPAM1NiT Of
Business • Professional Regulation
BCISHeme I Lagtn I User Registration I Hot Topic I Submi[swchame I S
SHOPSTAMPREVIEW Iatn/Plan
Review Is for general compliance with the Construction Documents.
Res onsibility for correctness of dimensions, details, quantities and safety
durPng fabrication Iles solely with the contractor.
X No Exceptions Taken Reviewed By: Dawn Boggio-Korbelak
❑ Rejected:
ats a Facts I Publications I contact Us I BCIS Site Mao I Links I Search
db'
7 s. Product Approval
4,2$,20 ►�_
r
p USER: Public User
yyyyyy��
tia�iep•-s
Product AOereval Menu > Product or Apolirallon
Search > 91yr11[atkln List> Application Detail
FL #
FL21637-R6
Application Type
Revision
Code Version
2017
Application Status
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
❑
Product Manufacturer MI Windows and Doors
Address/Phone/Email 650 West Market Street
Gratz, PA 17030
(717) 365-3300 Ext 2560
bsitlinger@miwd.com
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Certification Mark or Listing
Certification Agency American Architectural Manufacturers Association
Validated By Steven M. Urich, PE
:+ Validation Checklist - Hardcopy Received
Referenced Standard and Year (of Standard) Standard
AAMA 506
AAMA/WDMA/CSA 101/I.S.2/A440
AAMA/WDMA/CSA 101/I.S.2/A440
Equivalence of Product Standards -
Certified By
REVISgDN
Product Approval Method Method 1 Option A FILE COPY
Date Submitted 03/23/2020
Date Validated 03/23/2020
Date Pending FBC Approval
Year
2011
2008
2011
https:IA&ww.floridabuilding.org/pr/pr app_ tl.aspx?pamm=wGEVXQwtDgsgxV7TjKGeecQb2JXWyWd1%2faFQMzcwO%2bVvWOJaurmO%3d%3d 1/3
4/24/2020 Florida Building Code Online
Date Approved 03/26/2020
Summary of Products
FL #
Model, Number or Name
Description
21637.1
1620 SH
48 x 84 Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16015.gdj
Approved for use outside HVHZ: Yes
FL21637 R6 C CAC APC 16054.gdf
Impact Resistant: No
Quality Assurance Contract Expiration Date
Design Pressure: +45/-45
10/14/2021
Other: LC-PG50 Fin, LC-PG45 Fnless/Flange
Installation Instructions
FL21637 R6 II 08-02998B.pdf
Verified By: Luis Roberto Lomas 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 5138618.gdf
Created by Independent Third Party: Yes
21637.2
1620 SH
52 x 75 Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16016.gdj
Approved for use outside HVHZ: Yes
FL21637 R6 C CAC APC 16055.gdf
Impact Resistant: No
Quality Assurance Contract Expiration Date
Design Pressure: +50/-50
10/14/2021
Other: LC-PG50
Installation Instructions
FL21637 R6 II 08-029991.gd(
Verified By: Luis Roberto Lomas 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE S13862B.Pdf
Created by Independent Third Party: Yes
f21637.3
16
137 x 72 Insulated Glass
(Limits of Use
lApproved for use in HVHZ: No
tApproved foruse outside HVHZ: Yesl
Certificatiorn Agency Certificate
iFL21637 R6 C CAC APC 16572.pJ
Quality Assurance Contract Expiration Date
(Impact Resistant:. No:
O3/24/2022�
Design Pressure: +50/-67
Other. LC-PG50
Installation Instructions
I1`1-21637 .R6 IL'08-030426ptl0
erifled By: Luis. Roberto Lomas 62514
Created by Independent Third Pa ; Yes
Evaluation Reports
�FL21637 %R6 AE514078A pdfl
'Createdby'Independent Third Party: Yes
21637.4
1620 SH
48 x 96 Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16574.ndf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
03/24/2022
Design Pressure: +35/-45
Installation Instructions
Other: LC-PG35
FL21637 R6 It 08-03160A.p_df
Verifed By: Luis Roberto Lomas 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 514079A.ndf
Created by Independent Third Party: Yes
21637.5
1620 SH Impact
38 x 75 Fin and Finless Frame, Insulated, Laminated Glass.
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC(18143)1820.05-106-12-RI 1620
SF1(0UM).11-df
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Quality Assurance Contract Expiration Date
Design Pressure: +501-70
OS/15/2023
Other: 1-C-PG50, Missile Level D, Wind Zone 3, glass was
Installation Instructions
bedded in Pecora 896 silicone.
FL21637 R6 II 08-03454A.ndf
Verified By: Luis R. Lomas, PE PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 514467A.ndf
Created by Independent Third Party: Yes
21637.E
1620 SH Impact
52 x 75 Insulated Laminated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL21637 R6 C CAC APC 16230.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
https:/Avww.floridabuilding.org/pr/pr app dtl.aspx7paramzvGEVXQwtDgsgxVTrjKGeecQb2JXWyWd1%2faFQMzc 0� /O 2bVvWOJaurmQ%3d%3d 2/3
EIM-0'IrYif,
Florida Building Code Online
Impact Resistant: Yes 12/27/2021
Design Pressure: +50/-50 Installation Instructions
Other: LC-PG50, Missile Level D, Wind Zone 3. Glass consisted FL21637 R6 11 08-030426.pdf
of 1/8" annealed exterior - spacer - 3/32' annealed / 0.090 Verified By: Luis Roberto Lomas 62514
PVB / 3/32" annealed. Glass was bedded in Pecora 896 silicone. Created by Independent Third Party: Yes
Evaluation Reports
FL21637 R6 AE 513921B.pdf
Created by Independent Third Party: Yes
Bark nett
Contact $ :: 2601 Blair Stone Road. Tallahassee R 32399 Phone: 850-487-1824
The State of Fl9dda Is an AA/EEO empiayen sopyd ht 2007-2013 State of Florida.:: I d,I Statement :: �[v B[ [ t :: Refund Statemen
Under need. law, email addresses are publk records. If you do nut want your e-mail address released in response t4 a public -records request, do not send electronic
mall to this entity. Instead, contact the pHlm by phone or by traditional mall. If you have any questions, please contact 850.487.1395.'Pumua or to Section 455.275(1
Florida Statutes, effective October 1, 2012, licensees Ilmnsed under Chapter 455, F.S. must provide the Department with an email address If they have one. The email
provided may be used for offlclal communication with the licensee. However email addresses are public remm. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click bE
Product Approval Accepts:
= ® © RE M
Credit Card
Safe
https:IAw .floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgs9xV7TjKGeecOb2JXWyWri1%2faFQMzcvxO%2bVMOJaurmQ%3d%3d 313
L. Roberto Lomas P.E.
1432 Woodford Rd.
Lewisville NC, 27023
434-688-0609
rllomas@lrlomwpe.com
Manufacturer: MI Windows and Doors LLC
650 West Market Street
Gratz, PA 17030
Engineering Evaluation Report
Product Line: Series 1620 PVC Single Hung Window— Reinforced Non -Impact 37°x72"
Report No.: 514078A
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed
herein complies with requirements of the current Florida Building Code.
Supporting Technical Documentation.,
1. Approval documents: drawing numbers 08-03159 Revision A, prepared, signed and sealed by Luis Roberto
Lomas P.E.
2. Report No.: G9384.01-109-47 signed by Timothy J. McGill
Architectural Testing, Inc., York PA.
AAMAIWDMA/CSA 101/I.S.2/A440-11
Design pressure: t67.20psf
Water penetration resistance 7.52psf
3. Anchor calculations, report number 514078-1A, prepared, signed and sealed by Luis Roberto Lomas P.E.
Limitations and Conditions of use:
• Maximum design pressure: +50.0/-67.Opsf
• Unit size: 37" x 72"
• Units must be glazed per ASTM El300-04/09.
• This product is not rated to be used in the HVHZ.
• This product is not impact resistant and requires impact protection in wind bome debris regions.
• Frame material to be rigid PVC.
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval document 08-03159,
Revision A.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity
involved in the approval process of the listed product(s).
1 of 1
�111111.1///
\`���\S R. L pii���
5
��•���TAT �i<, —
0
�� F•. � �R10P • �i'�•
s��NALIE����\
Luis R. Lomas, P.E.
FL No.: 62514
01/20/2020
(Validator / Operations Administrator)
MI Windows & Doors, LLC
P.O. Box 370
Gratz, PA 17030-0370
Attn: Rick Sawdey
AAMA
CERTIFICATION PROGRAM
AUTHORIZATION FOR PRODUCT CERTIFICATION
This authorization is based on the successful completion of tests, and the reporting to the AAMA Validator of the results of the tests by an
AAMA Accredited Laboratory. The product information below will be added to the next update of the AAMA Certified Products Directory.
SPECIFICATION
RECORD OF PRODUCT TESTED
AAMAANDMA/CSA 101/i.S.2/A440-11
LC-PG50•-940xl829 (37x72)-H
Negative Design Pressure = -67 psf
COMPANY AND CODE
CPD NO.
SERIES MODEL & PRODUCT
MAXIMUM SIZE TESTED
DESCRIPTION
1620 SH (FIN, FLANGE &
MI Windows & Doors, LLC
FINLESS)
FRAME
SASH
16572
(PVC)(O/X)(OG)(INS GL)
940 mm x 1829 mm
867 mm x 902 mm
Code: MTL
(MODIF)(REINF)(TILT)
(3'1" x 6'0")
(2'10" x 3'0")
(ASTM)
This Certification will expire March 24, 2022 and requires validation until then by continued listing in the current AAMA Certified
Products Directory.
Product Tested and Reported by: Intertek-ATI
Report No.: G9384.01-109.47
Date of Report: May 3, 2017
JGS/JTS
ACP-04 (Rev. 6/11)
Evaluated for Certification: May 4, 2017
'h'
A oci ted Laboratories, Inc.
Authorized for Certification: May 4, 2017
��IZ4I
AmerUn Architectural Manufacturers Association
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
B. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT
EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR
GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 2 AND 3 FOR DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
L TABLE OF CONTENTS
SHEET NO.1 DESCRIPTION
1 NOTES
2 — 3 ELEVATIONS
4 — 16 1 INSTALLATION DETAILS
17 1 COMPONENTS
RR1510N5
REV OESCRIPRON .1 1 01R.
A I REVISED ANCHORS 02/27/16 I R.L.
15. FOR ANCHORING THROUGH FIN INTO METAL STRUCTURE USE #6 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
16. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO
SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
17. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
18. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE $8 SMS OR SELF DRILLING
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE
INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
19. ALL FASTENERS TO BE CORROSION RESISTANT.
20. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR
ALUMINUM 6063—T5 FU=30KS1 1/8" THICK MINIMUM
21. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS
SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN
IN SHEET 2.
SIGNED: 0112812020
MI WINDOWS & DOORS, LLC.
65D WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
NOTES
NTS w1c 11/30/16 OB s03E�12 OF 17 A /q�S�DNA1-ENJ�r
LROSERMLOMASP.E Luis R. Lomas P.E.
IC32WCODFORDROLEWISVILLENC2M23 FL NO.: fi2514
41-6880609 Namaz@IMmazpR.mm
7
FR
HE
{-- 52 1/8" FRAME WIDTH —I
4" MAX
p
13 1/4"
MAX O.C.
O
5"
\ME
GHT
4" MAX
/
X
4
0�
1620 SH REINFORCED
RECTANGULAR
EXTERIOR VIEW
FINLESS& FLANGEINSTALLATION
NOTES:
1. SASH SIZE 491/2'X37114'
R. D.L.O.:4712'X33374'
52 1/8" FRAME WIDTH
4" MAX
13 1/4'
O
MAX O.C.
/
75"
FRAME
HEIGHT
/
X
\
4" MAX
FOR NUMBER
OF ANCHORS
1620 SH REINFORCED
REQUIRED
DESIGNER
SEE CHART #1
EXTERIOR VIEW
FINLESS & FLANGE INSTALLATION
REINFORCED
DESIGNPRESSURERATING
IMPACTRATING
±50.OPSF
LARGE
MISSILEIMPACT
MISSILE LEVEL D, WIND ZONE
FORADDITIONAL SIZES SEE CHART#1
52 1/6'X75-UNDSHOWN. OTHER SIZESAPPROVEDAS LONGAS
FRAME AREA DOES NOT EXCEED 27.14' FlA
REYI510us
DESCRIP GN wit nwaovtD
REVISED ANCHORS 02/27/18 1 R.L.
%IgFt
FOR NUMBER 7/8"
19
OF ANCHORS
3/32" ANN
REQUIRED
SEE CHART #1
0.090" PVB BY KURARAY
1/8" ANN
3/32" ANN
TRUSEAL
SPACER
SYSTEM
1/2" BITE
GLAZING DETAIL
SIGNED: 01/28/2020
MI WINDOWS
T MAR ET STREET
`\`��\51RIILIo4A
'`�v
GRATZ. PA 17030-0370
•y\GENy�.'9j+Z�
D/,,��{�y *=
SERIES 1620 SH REINFORCED
IMPACT
IMPACT — 52" %
�•
VAT
FINLESS Sc FLANGE ELEVATIONS
'"" Cz
�.A • TAT OF 4
i
i0S`ORID?'
DaAwu:
rrnc No.
aw
08
A
,Z,7S/OIIIAli1�?``\�
LOIS R. Lomas P.E.
3c NITS wft 11/30/16 NI�22 OF 17
L.ROSERTOLOWSP.E
f432 WOODFORDRDLEWISVlLUF NC27023
aa4eeaa&ov mama:®Irbmsspe.wm
FL No.: 62514
FR
HE
3" MAX
I
3 MAX—
8" MAX Q.C.
5"
WE
GHT
3" MAX
1620 SH REINFORCED
RECTANGULAR
EXTERIOR VIEW
FIN INSTALLATION
NOTES:
1. SASH SIZE: 4912'X371/4'
2. D.L.0.:471/2'X333/4'
52 1/8" FRAME WIDTH —
MAX
3" MAX
— 8" MAX O.C. —
FOR NUMBER
OF ANCHORS
3" MAX
/
REQUIRED
SEE CHART #2
8" MAX O.C.
/
75"
FRAME
HEIGHT
/
X
4 0�
II
3" MAX
1620 SH REINFORCED
DESIGNER
EXTERIOR VIEW
REINFORCED
FIN INSTALLATION
DESIGN PRESSURERATING
IMPACTRA77NG
350.OPSF
LARGE
MISSILEIMPACT
MISSILE LEVEL D. WIND ZONE
FOR ADDITIONAL SIZES SEE CHARTF2
521/6'X 75' UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS
FRAME AREA DOES NOT EXCEED 27.14' M
RWMONS'
)VOCRI"ON w1E T 1..D
REVISED ANCHORS 02/27/18 R.L
3" MAX
FOR NUMBER
OF ANCHORS
REQUIRED
SEE CHART #2
7/8"
—
3/32" ANN
0.090" PVB BY KURARAY
1/8" ANN —
3/32" ANN
TRUSEAL
SPACER
SYSTEM
1/2' BITEA
GLAZING DETAIL
SIGNED: 0112812020
MI WINDOWS LC.
0ESTMAR ET STREET
`J\J\?1E=11:D1J/��i
GRATZ, PA 17030-0370
` r;\GENSF9j1��
SERIES 1620 SH REINFORCED*•
IMPACT — 52" X 75"
FIN ELEVATIONS
//��+W+
to OTM •C-
��D TAT OE 41—
•
ORnwN:
Dw0 NO.
aRv�"FS:;ORIOo;
R.L.
08503042
A
'/7ASIOfIlAl10?\\\\
LUIs R. LOTOs P.E.
S D"� 11/30/i6 OF 17
LROBERTOLOMASPZ.
1432WDDDTDRD RDLEWISVILLE, NC 2>023
4 WOOD OR DLEWISLLZNC 27
4�3
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
1/4" MAX.
SHIM SPACE
HEAD TO BE SET
IN A 1 OF
APPROVED
VERTICAL CROSS SECTION
WOOD FRAMINGOR2 BUCKINSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARIT ..
2. PERIMETERANDJOIN7SEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WITHASTM M 12
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1/4" MAX.
HIM SPACE
1 1/4- MIN.
EMBEDMENT
L
7/16" MIN.
EDGE DISTANCE
RMSIONS
REV D6 RIPTION IMM MPRO
A REVISED ANCHORS 02/27/19 R.L.
1/4" MAX.
SHIM SPACE
INTERIOR
/j8 WOOD
SCREW
�0
WOOD FRAMING
OR 2X BUCK
EXTERIOR
BY OTHERS
BACKER ROD
& APPROVED
SEALANT,
JAMB INSTALLATION DETAIL
W60D FRAMING OR 2X BUCKINSTALLATION
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
FINLESS INSTALLATION DETAILS
OMWN: OWC u0. 1 REV
R.L. 1 08-03042 A
SC E NTS °^TE 11/30/16 SREET4 OF 17
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
RMSIONS
DSCRIPRON MlE nPPRMD
REVISED ANCHORS 02/27/18 R.L.
1/4" MAX.
METAL
SHIM SPACE
STRUCTURE
BY OTHERS
APPROVED
_ 1/4" MAX.
SEALANT
r SHIM SPACE
o�
7/16" MI IN
INTERIOR
EDGE
o
HEAD TO BE SEE
DISTANCE
IN A BED OF
APPROVED SEALANT
p®
�❑
SELF SCREWS
0
EXTERIOR
o
o
INTERIOR
EXTERIOR
METAL
O
STRUCTURE
BY OTHERS BACKER ROD
& APPROVED
JAMB INSTALLATION DETAIL
SEALANT
METAL STRUCTUREINSTALLATION
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
BACKER ROD
& APPROVED
SEALANT �� Q 1/4" MAX.
r SHIM SPACE
BY
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WIMASTM E2112
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
FINLESS INSTALLATION DETAILS
DWO N0.
08-03D42
NTS DAB 11/30/16 sH� S OF 17
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
CONCRETE/MASONRY
BY OTHERS
°Q
OPTIONAL 1X BUCK m �'
SEE NOTES 3 - 7
SHEET 1
I
BACKER ROD �
& APPROVED r1
1/4 MAX'
SEALANT SHIM SPACE
AD TO BE SET
/APPROVED
=.
INTERIOREXTERIOR�%i_ a a
SILL TO BE SET
BACKER ROD IN A BED OF
& APPROVED APPROVED SEALANT
SEALANT
O OPTIONAL IX BUCK 1/4" MAX.
SHIM SPACE
SEE NOTE 3 7 �q ❑
SHEET 1
CONCRETE/MASONRY
BY OTHERS
a
NOTES:
I. INTERIORAND EXTERIOR FINISHES, BYOTHER&
NOT SHOWN FOR CLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WITHASTM M12
ENSIGNS
REV OESCRIPiION CAiE APPROVED
A REVISED ANCHORS 02/27/18 R.L.
1 1/4" MIN.
_
1/4- MAX.
EMBEDMENT
SHIM SPACE
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK
-
SEE NOTES 3 - 7
SHEET 1
INTERIOR
3/16" TAPCON
Y
MIN.
D
EDGE
a
DISTANCE
--
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
CONCRETNMASONRY INSTALLAT ION
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
FINLESS INSTALLATION DETAILS
MWN: OWO NO.
R.L. 08-03042
iCRLE NTS wie it/30/16 1..E-6 OF 17
L ROSERTOLOMASP.E
1432 WOODFORD RD LEWISVILL E, NC 27M
G34EB&0609 Nanazt3lnomazpa.rom
SIGNED: 0112812020
.P�:911R 11�lO�AYi..
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
1/4' MAX.
SHIM SPACE
IL11MI HEAD O BE SET
BED OF
vp
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCKINSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCEWIMASTM E2112
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
/4" MAX.
HIM SPACE
R SIONS
DESCRIPTION WiE MPRWEO
RMSED ANCHORS 02/27/18 R.L.
1 1/4" MIN. 1/4' MAX.
EMBEDMENT SHIM SPACE
L INTERIOR
7/16" MIN. Ga
EDGE DISTANCE
#B WOOD
SCREW
WOOD FRAMING
it 0
U::j
OR 2X BUCK
EXTERIOR
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCKINSTALLATION
SIGNED: 0112812020
MI WINDOWSLC
Rl to
50WEST MARKET STREET
�J�5w,///
GRATZ. PA 17030-0370
EMS,%:j±�
0 51/T
SERIES 1620 SH REINFORCED
IMPACT — X 75"
�*=
7( �s>rgt�`
I
FLANGE INSTALLATION DETAILSTAT
A OF OF
���'OF•.'P[OR101;•�i���
DR"
MG NO.
RLv
OB
A/O111A111��G\``
Luis R. Lomas P.E.
503072 OF 17
'r^'L NTS D^TL 11 /30/16
L ROSERTO LOWS P£.
fAffi WOODFORD RDLEM6VILMNO273
46
FL No.: 62514
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
1/4" MAX.
SHIM SPACE
REVISIONS
DESCRIPTION W.iE MPRWEO
REVISED ANCHORS 02/27/18 R.L.
1/4" MAX.
SHIM SPACE
�
I
HEAD TO BE SET
IN A BED OF
I
7/16" MIN.
INTERIOR
APPROVED SEALANT
EDGE
DISTANCE
�^
o
b�
�❑
�
EXTERIOR
INTERIOR
#8 SMS OR
�❑
o n n
O
SELF DRILLING
SCREWS
0
�
EX ERIOR
METAL
STRUCTURE BACKER ROD'
BY OTHERS
& APPROVED
SILL BE SET
SEALANT
JAMB INSTALLATION DETAIL
p
II
B
IN A BED OF
APPROVED SEALANT
METAL STRUCTURE INSTALLATION
BACKER ROD
& APPROVED
SEALANT �� 1/4" MAX.
F SHIM SPACE
METAL
STRUCTURE —�
BY OTHERS
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BYOTHERS,
NOT SHOWN FOR CLARITY:
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WITHASTM Elf 12
SIGNED: 0112812020
MI WINDOWS50WESTMAR
REETLC.
ET STREET
`\\``\�11R11L(ow
GRATZ, PA 17030-0370
'`may •��G EN3FgJE
*• 01.51251 *_
SERIES 162D SH REINFORCED
IMPACT - I % 75"
FLANGE INSTALLATION DETAILS
�
�70 , TAT OF ty`
O. p L`
�i�'OFS FLORID,
ORnwu:
Owc NO. -
an
08 2
A
/O1111110?\\``
LI115 R. LOTOS P.E.
'DACE NTS GATE 11/30/16 SOEET8OF 17
LROBERTOLOMASP.E
lG WOODFORDRDLEWISVIILENC27O23
48 8"609 rllwnas@Irlomaspe.com
FL NO.: 62514
RLMSIONS
PEV DESCRIPTION
pg1E APPROVE.
CONCRETE/MASONRY
-
A RMSED ANCHORS
02/27/18 R.L.
BY OTHERS
'° i
OPTIONAL 1X BUCK
..
1 1/4" MIN.
1/4" MA%.
SEE NOTES 3 - 7SHEET
EMBEDMENT
SHIM SPACE
1
r
CONCRETE/MASONRY
�r'-I
�
BY OTHERSBACKER
ROD
APPROVED
��JJ
a&
��SEALANT [�ovaOPTIONAL
1% BUCK
SEE NOTES 3 - 7
SHEET 1
IN A BED OF
INTERIOR
APPROVED SEALANT
3/16" TAPCON
p® Lam❑
EXTERIOR
INTERIOR
•°.a
o v v
0
2
n❑
MII N.
EDGE
vo
a
DISTANCE
,
EXTERIOR
SILL TO BE SET
BACKER ROD
IN A BED OF
BACKER
ROD
& APPROVED
APPROVED SEALANT
& APPROVED
SEALANT
SEALANT
'
1/4" MAX.
O�
JAMB INSTALLATION DETAIL
OPTIONAL 1% BUCK
SEE NOTE 3 - 7
��
o SHIM SPACE
CONCRETE7MASONflY1NSTALIATION
SHEET 1
T
CONCRETE/MASONRY
BY OTHERS
-
°
4
•W
d•
,
SIGNED: 0112812020
°•
MI WINDOWS DOORS, LC.
`y��y`RE 5
VERTICAL CROSS SECTION
A 17 0-0370
9���
CONCRETHMASONRY
INSTALLATION
SERIES 1520 SH REINFORCED
*�• �1D *=
IMPACT - 52" X 75"
FLANGE INSTALLATION DETAILS
�jl X• $$TAT OF p=
DRAWN:
REV
DWG N0.INTERIOR
.Len`
NOTES:
OB
Fs:�[ORIOP
',',STONAI.1111M
1. AND
CLAR/TV,ERIOR FINISHES, BYOTHER$
A
NOT SHOWN FOR
SCALE NTS D^� 11/30/16 50 92 OF 17
2. PERIMETERANDJOINTSEALANTBYOTHERS TOBE
DESIGNED /N ACCORDANCEWRHASTM
E21 f2
LROSERTOLOMASP.E.
LYLS R. Lomas P.E.
lC2WO0VF ROROLEWISVILLe.NC27o29
dM.MMfJ1V Afmm�dd---mm
FL No.: 62514
REVISIONS
OESCRIPNON
REVISED ANCHORS
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD --� �Uu 1/4" MAX. J
& APPROVED SHIM SPACE
SEALANT 1 1/4" MIN. 1/4" MAX.
oQ EMBEDMENT SHIM SPACE
I r INTERIOR
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
YlE TO BE SET
�..I PROVED
OF
SEALANT
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCKINSTALLATION
NOTES:
1. INTERIORAND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETERANDJOWTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WRHASTM E2112
SILL TO BE SET
IN A BED OF -
APPROVED SEALANT
/4" MAX.
:HIM SPACE
7/15" MIN.
EDGE DISTANCE
#B WOOD
SCREW D
WOOD FRAMING '��D EXTERIOR
OR 2X BUCK flflUU
BY OTHERS
BACKER ROD
& APPROVED JAMB INSTALLATION DETAIL
SEALANT WOOD FRAMING OR 2XBUCKINSTALLAT70N
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
FLANGE INSTALLATION DETAILS
DIM..:
MG No.
R.L.
08-03042
5-" NTS
IMTE 11/30/16 SNEET10 OF 17
L ROSERTOLOMASP.E
l4 WOODF0RDRDLEWISVILLENO2=
M1E I.PPROJEO
02/2]/15 R.L.
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
1/4" MAX.
SHIM SPACE
REVISIONS
omll 110N Mn 1 A,PRo ED
REVISED ANCHORS 02/27/18 1 R.L.
_
/4" MAX.
o�
HEAD SET
SHIM SPACE
IN A BEE OF
OF
APPROVED SEALANT
L_
7/16" MIN.
INTERIOR
EDGE
ca
DISTANCE
o
EXTERIOR
p®
=❑
INTERIOR
#8 SMS OR
e
��Iy
SELF
v
v v
SCREIWS
��0
O
EXTERIOR
METAL
STRUCTURE BACKER ROD
BY OTHERS
& APPROVED
SILL TO BE SET
SEALANT
IN A BED OF
APPROVED SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
BACKER ROD
EJ
& APPROVED
SEALANT
1/4" MAX.
��
SHIM SPACE
METAL
STRUCTURE
—�
BY OTHERS
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOA FINISHES, BYOTHERS,
NOTSHOWNFORCLARTFY.
2. PERIMETERANDJOIN7SEALANTBYOTHERSTOBE
DESIGNED IN ACCORDANCE WITH ASTM E2112
SIGNED: 0112812020
Nib WINDOWSLC.
IR IILlq/*
WEST MARKETDOORS,
9ARKSTREET
``\\`\S
GRATZ. PA 17030-0370
V •��O E Ng�.•9ji
*�• �105 'k=
SERIES 1620 SH REINFORCED
IMPACT — X 75"
FLANGE INSTALLATION DETAILS
ATI
;y~• SS TAT OF tp`
C � �\
DRAWN:
OWC N0.
REV
0B
A
.ZORIO?•
��XXssiONA'IE�G�p
LOTS R. Lomas P.E.
FL No.: 62514
soot NTS GATE 11/30/16 sOLET 11 OF 17
L flOSERTO LOMASP.E.
1432 WOODFORD RD LEWI9VILLE NO 27023
0.94-666-0609 EllomasTdlMnamR.mm
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK
SEE NOTES 3 - 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
•A
° •
a u
I
1/4" MAX.
owl
SHIM SPACE
0
HEAD BE.SEi
IN A BED OF
,,,,,,
APPROVED SEALANT
INTERIOR
SILL TO BE SET
BACKER ROD IN A BED OF
& APPROVED APPROVED SEALANT
SEALANT
ED 1/4" MAX.
OPTIONAL 1X BOCK a Q� SHIM SPACE
SEE NOTE 3 - 7
SHEET 1
CONCRETE/MASONRY
BY OTHERS
a
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BYOTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER ANOJOINTSEALANTBYOTHERS TO BE
DESIGNED INACCORDANCE WITHASTM E2112
RMSIONS
REV OMRIPTIION Mx PPPROAD
A REVISED ANCHORS 02/27/18 1 R.L.
1 1/4" MIN.
EMBEDMENT
CONCRETE/MASONRY I
BY OTHERS
°v
OPTIONAL 1X BUCK R
SEE NOTES 3 — 7 _ 1/4" MAX.
SHEET 1 ° : SHIM SPACE
INTERIOR
3/16" TAPCON
IN
MIN.
EDGE
v >
L❑
n
n�D
DISTANCE
°
EXTERIOR
BACKER ROD
& APPROVED
JAMB INSTALLATION DETAIL
SEALANT
CONCRET&MASONRYINSTALLATION
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
FLANGE INSTALLATION DETAILS
ORnwu: on No.
R.L. 08-03042
sME NTS IWE 11/30/16 OHEE112 OF 17
L ROBERTOLOMASP.E.
1432 MODFOROROLEWISVILLE NOVO23
134-6BB-0609 rllwnas�Wlrbmssp.rom
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
APPROVED
SEALANT
BEHIND FIN
#6 WOOD
SCREW
3/8- MIN
EDGE DISTANCE
i
�I�H�YI�Ii■
3/8" MIN
EDGE DISTANCE
#6 WOOD
SCREW
APPROVED
SEALANT
BEHIND FIN VERTICAL CROSS SECTION
WOOD FRAMING OR 2K BUCK INSTALLATION
NOTES:
1. INTERIORANDEXTERIORMNISHES, BYOTHERS,
NOT SHOWN FOR CLARITY.
2 PERIMETERAND JOINT'SEAIANTBY OTHERS TO BE
DESIGNED INACCORDANCE WITHASTM E2112
WOOD
FRAMING
BY OTHERS
1/4" MAX.
SHIM SPACE
WOOD FRAMING BY OTHERS
#6 WOOD
SCREW
1 1/2-
MIN.
EMBEDMENT
RNSIONS
OMRIPTION
REVISED ANCHORS
_ 1/4" MAX
SHIM SPACE
INTERIOR
APPROVED
SEALANT n�D
DUI
BEHIND FIN
3/8" MIN EXTEflIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR ZK BUCK INSTALLATION
1/4- MAX
SHIM SPACE
wooD
FRAMING
MI WINDOWS & DOORS, LLC.
BY OTHERS
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT - 52" X 75"
FIN WITH J CHANNEL INSTALLATION DETAILS
DRAWN:
DWs No.
R.L.
08-03042
SCALE NTS IDATC 11/30/16 SHEE713 OF 17
DgiE PPgP/EO
)2/27/1B R.L.
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
#6 SMS OR
SELF DRILLING
SCREW
3/8" MIN
EDGE DISTANCE
I
��JM
C.J
' hl�:Fi��:iJ
3/e" MIN
EDGE DISTANCE
#6 SMS OR
c
SELF DRILLING
SCREW
VERTICAL CROSS SECTION
APPROVED
METAL STRUCTURE INSTALLATION
SEALANT
BEHIND FIN
NOTES:
1. INTERIORAND EXTERIOR FINISHES. BY OTHERS.
NOTSHOWN FOR CLARITY.
2. PERIMETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCE WITHASTME2112
aWSIM
atv Gtscaivnou
METAL STRUCTURE A I RE SED ANCHORS
BY OTHERS
1/4" MAX.
SHIM SPACE
1/4" MAX
SHIM SPACE
METAL STRUCTURE
BY OTHERS
1/4" MAX
SHIM SPACE
METAL STRUCTURE
BY OTHERS
NTERIOR
#6 SMS OR �\
SELF DRILLING j•j� �e
SCREW s
APPROVED
SEALANT
BEHIND FIN
EXTEAIOA
3/8" MIN _
EDGE DISTANCE
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
FIN WITH J CHANNEL INSTALLATION DETAILS
D..N: GwG NO.
R.L. 08-03042
sr• r NTS JIMIE 11/30/16 ISHOU14 OF 17
LROBERTOLOMASP.E.
1492 WOODFORDRDLEWISYUF NC2=
434- 8-0 9 Namas@Irlomesyemm
MlE APPRMO
12/21/18 1 R.L.
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
APPROVED
SEALANT
BEHIND FIN
#6 WOOD
SCREW
3/8" MIN
EDGE DISTANCE
I
C� I
a till
3/8" MIN
EDGE DISTANCE
#6 WOOD
SCREW
APPROVED _-----
SEALAMT
BEHIND FIN VERTICAL CROSS SECTION
WOOD FRAMING OR2X BUCKINSTALI ITION
_ 1 1/2" MIN.
EMBEDMENT
WOOD
FRAMING
BY OTHERS
1/4" MAX.
_r SHIM SPACE
NOTES:
1. INTERIORAND EXTERIORFINISHES, BYOTHERS,
NOTSHOWNFORCLARITY.
2. PERIMETER AND JOINTSEALANTBY OTHERS TO BE
DESIGNED INACCORDANCE WTTHASTM E2112
1/4" MAX
SHIM SPACE
WOOD
FRAMING
BY OTHERS
REY510N5
06LRIRIDN ONE 1 PRD O
REVISED ANCHORS 02/27/18 1 R.L.
—I
1/4' MAX
SHIM SPACE
WOOD FRAMING
BY OTHERS
#6 WOOD
SCREW
INTERIOR
1 1/2"
IN.
EMBEDMENT
nn
APPROVED NT^N
SEALAILJ
BEHIND FIN
3/8" MIN EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR2X BUCKINSTA"TION
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
FIN INSTALLATION DETAILS
DRRWN: DWG NO.
R.L. 08-03042
'� NTS D`h 11/30/16 IsHEI715 OF 17
SIGNED. 0112812020 1
Luis R. Lomas P.E.
FL No.: 62514
APPROVED
SEALANT
BEHIND FIN
#6 SMS OR
SELF DRILLING
SCREW
3/8" MIN
EDGE DISTANCE
_��"� Fes,■
3/B" MIN
EDGE DISTANCE
#6 SMS OR
J
c
SELF DRILLING
SCREW
VERTICAL CROSS SECTION
APPROVED
METAL STRUCTURE INS TALLA77ON
SEALANT
BEHIND FIN
NOTES:
1. INTERIORAND EXTERIOR FINISHES. BY OTHERS,
NOTSHOWNFORCLARRY.
2. PERIMETER ANDJOINTSEALANTBY OTHERS TO BE
DESIGNED INACCOROANCE WITHAS7M E2112
PPAAONS
RLv DESDRivriDN
METAL STRUCTURE A REVISED ANCHORS
BY OTHERS
1/4- MAX,
SHIM SPACE
_ 1/4" MAX
SHIM SPACE
METAL STRUCTURE
BY OTHERS
INTERIOR
#5 SMS OR
SELF DRILLING
SCREW
/4" MAX
SHIM SPACE
METAL STRUCTURE
BY OTHERS
APPROVED
SEALANT
BEHIND FIN
LUI
3/8" MIN
EXTERIOR
EDGE DISTANCE
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
MI WINDOWS & DOORS, LLC.
650 WEST MARKET STREET
GRATZ, PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT - 52" X 75"
FIN INSTALLATION DETAILS
Dw.wN: MG No.
R.L. 08-03042
5O NTS JOKIE 11/30/16 ISHEV16 OF 17
2
i1E APPROVED
2T/18 R.L.
SIGNED: 0112812020
Luis R. Lomas P.E.
FL No.: 62514
3 3/ifi'
o�2 5/16"
��- p 4
HEAD/JAMB FINLESS
EXTRUDED PVC (V-1006)
3 13/16"
HEAD/JAMB FIN INSTALLATION
EXTRUDED PVC (V-1007)
3 1/4" —I
0�8..
t�Ip.4
SILL FINLESS
EXTRUDED PVC (V-1013)
3 5/8"
SILL FIN INSTALLATION
EXTRUDED PVC (V-1012)
3/16"
o¢�
2 13/16 �� 51
4�pC]4
HEAD/JAMB WITH FLANGE
EXTRUDED PVC (V-1010)
3 1/4" —
os O
2 13/16" L—J
HEAD/JAMB WITH FLANGE
EXTRUDED PVC (VE-000025)
t 1/a'
T—P
rf1�oJ�
�lilp0 3 5.
L LrtiJ - J 1 3/4"
L
BOTTOM SASH/STILE
WCAI IAIIAD cm1 MICTAI I ATInAl Cu I c At NICTAI I IT11. EXTRUDED PVC(V-670)
WITH J-CHANNEL
EXTRUDED PVC (V.1006)
J--�
7/8-14-
STILES
REINFORCEMENT
ALUMINUM 6063-T5 (M-2266)
WITH J-CHANNEL
EXTRUDED PVC (V.1011)
MEETING RAIL
REINFORCEMENT
ALUMINUM 6063-T5 (AE-000162)
15/i6" �1-
1/2`
LOCK RAIL
REINFORCEMENT
ALUMINUM 6063-T5 (M-2115)
DESCRIPTION
REVISED ANCHORS
SILL WITH FLANGE
EXTRUDED PVC (V-1015)
'8"
SILL WITH FLANGE
EXTRUDED PVC (VE-000021)
1 1/4'
Ca
I� 2 3/16"
D oLfo
MEETING RAIL
EXTRUDED PVC (V.1016)
MI WINDOWS & DOORS, LL
650 WEST MARKET STREET
GRATZ. PA 17030-0370
SERIES 1620 SH REINFORCED
IMPACT — 52" X 75"
COMPONENTS
v
REVISION$
64iE AIPR-10
02/27/18 1 R-L.
_ 7 7/2"
HE],
1 3/4-
BOTTOM SASH?OP RAIL
EXTRUDED PVC (V-675)
1 3/4"
1 3/4"
Jf'
'
BOTTOM SASH/BOTTOM RAIL
EXTRUDED PVC (V-672)
_, 5/16"
13/1J 6' L
GLAZING NG BEAD
RIGID PVC (V.676)
SIGNED: 0112812020
\\\\1111I IITl7///
\\\\\g il. L0,y7///i
r •V\O EHSF,•9iP:
08-030L21R.L
7C7NTS IMIf 11/30/16 17 OF 17
Luis R. Lomas P.E.
FL No.: 62514
ALL MATERIALS AND CONSTRUCTIONS PROCEDURES SHALL BE IN ACCORDANCE WITH THE LATEST FDOT INDICES AND AS
FOLLOWS:
1. CONCRETE TO BE MINIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
2. TEST A MINIMUM OF ONE (1) COMPRESSIVE STRENGTH CYLINDER SAMPLE PER 50 CY OR ONE (1) PER LOT, WHICHEVER IS
GREATER. COMPRESSIVE STRENGTH SHALL BE REPORTED AT 28 DAYS.
3. ALL DELETERIOUS MATERIALS TO BE REMOVED 6 INCHES BELOW BOTTOM OF SIDEWALK AND 6 INCHES BEYOND ALL EDGES.
4. CONCRETE SHALL BE A MINIMUM OF 4 INCHES THICK FOR ALL SIDEWALK TO BE OWNED OR MAINTAINED BY THE COUNTY.
5. SIDEWALK THROUGH DRIVEWAYS SHALL BE 4" THICK MINIMUM.
6. SOD TO BE LAID WITHIN THREE (3) DAYS OF FINAL GRADING IN PUBLIC RIGHT OF WAY.
7. PRE -POUR INSPECTIONS ARE REQUIRED AND MUST BE ACCEPTED PRIOR TO POURING THE SIDEWALK.
8. FOR REPAIR, REMOVE EXISTING SIDEWALK TO THE FULL WIDTH FROM CONTROL JOINT TO CONTROL JOINT (I.E. ONE
"SECTION*)
9. 12" MINIMUM VISQUEEN AND CHEMICAL TERMITE TREATMENT AT ALL AREAS THAT ABUT ANY EXISTING CONCRETE
STRUCTURE.
10. PROPERTY ADDRESS: _ ARMINA PLACE
0
FILE COPY
CAULFIELD & WHEELER, INC.
e
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE -SURVEYING
7900 GLADES ROAD -SUITE 100
BOCA RATON, FLORIDA 33434
OrlPHONE (560-392-1991 / FAX (560-750-1452
WATERSTONE, PHASE 1
DRIVEWAY DETAIL - LOT 4, BLOCK 3
N;, 1, 1{: 1, 7(:
p' L'ND�F
_;G 05�'
1uli„
DATE 4
27 2020
DRAWN BY
EC
F.B. PG.
N/A
SCALE
N.T.S.
JOB NO.
8690
A
6'x6' WELDED
WIRE MESH
16,
4"
THICK
4" THICK I 4" THICK ® I
I DRIVEWAY I
CAULFIELD & WHEELER, INC.
CIVIL ENGINEERING
LANDSCAPE ARCHITECTURE - SURVEYING
7900 GLADES ROAD - SUITE 100
�®� BOCA RATON, FLORIDA 33434
PHONE (561)-392-1991 / FAX (561)-750-1452
4" EXPANSION
JOINT
4" THICK
SIDEWALK
JOINTS
IDATE 4/27/20201
IIF.B./ PG. N/AII
I1J0B NO. 8690 �I