Loading...
HomeMy WebLinkAboutCompaction reportHeadquarters UP C Sk t ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 A% &J JIVL AND TESTING Sebastian, FL. 3278 Olando Phone: 772589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: August 17, 2020 KSM JOB #: 203892-2d/SH/jo PERMIT#: 2005-0468 NUC# 528 CONTRACTOR: R & E Loader Service Nuc Model: MC-IDR-P JOB LOCATION: 5417 Cassia Drive Nuc Serial #: MD049528 Fort Pierce, Florida ITEM TESTED: Detached Building Pad TEST LOCATION DEPTH PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1. N.E. 0" - 12" 40 110.0 113.0 97.3% 2. Center 42 111.9 99.0% 3. S.W. 41 111.0 98.2% Soil Description: Brown Sand with Shell Fragments In Place Moisture: 9.0% Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 113.0 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Unstaked Foundation Respectfully Submitted: 114.0 - w E H 1130 1 .._.I.—..—..J.._..1..—... r I I I I I T P i I I I I 112.0 j—••—•I_ I I I i I I I I I F r i i i i i D R Y110.0 I I I I I 8 9 10 11 12 13 14 `` � , ❑ ������ Moisture - % of Dry Weight ` �P'• ` Ng �� Disclaimer: Contractor is responsible to maintain Q`• y the tested area in the condition that KSM g14 fr r completed the indicated passed compaction test. S? E it,KSM is not responsible if the tested area has been altered from the approved inspected condition. BryekH.rildhike`�: . V.P. of Engineering PE # 81439 8/18/2020 Email to: mcarthuresther@bellsouth.net Proudly Serving Florida since 1990