Loading...
HomeMy WebLinkAboutIntegrity Metals 1 inch 2020RegulationNow Busines's"I Professional BCIS Home I log In ' user ReglstratioO =. Hot TOWS { Submit Surcharge ; Stats & Facts Pubiicauons Contact Us BCIS Site Map Links Search ri �IU� Product Approval u.— Public user Produn App'—al Menu > Product or APOhcat+on Search a Ajplfcation List > Application Detail FL # FL28113-RO Application Type New Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Integrity Metals LLC Address/Phone/Ematl 2604 B Piper Drive Vero Beach, FL 32960 (772) 584-2654 Admin@integritymetaisfl.com Authorized Signature Joe Keene Admin@integritymetalsfi.com Technical Representative Address/Phone/(mail Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Locke Bowden the Evaluation Report Florida License PE-49704 Quality Assurance Entity PRI Construction Materials Technologies, LLC. Quality Assurance Contract Expiration Date 05/25/7023 Validated By Diane Marotta, P.E. m Validation Checklist - Hardcopy Received Certificate of Independence FL�3 RQ CQS IntegriLok IM 10C - Min. 26GA Nailstrio Renort - CS5.pdF Referenced Standard and Year (of Standard) Standard Year UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I Option D Date Submitted 09/25/2018 Date Validated 10/26/2018 Date Pending FBC Approval 10/26/2018 Date Approved 12/11/2018 Date Revised 02/20/2020 Summary of Products FL # Model, Number or Name Description 28113.1 IntegriLok IM100 - Min. 26GA Steel IntegriLok IM100 - Min. 26GA Steel Nail Strip Nail Strip Limits of Use Installation Instructions Approved for use in HVHZ: No 7: W^j1' Pf._F T_-'n F�riLok IM 100 - Min. 26GA Nailstrip Approved for use outside HVHZ: Yes-__r'.= Impact Resistant: N/A Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -SF Created by Independent Third Party: Yes Other: -86 PSF @ 10" Q.C. Install per manufacturer's Evaluation Reports details and in compliance with FBC 2017. FI-28113 R0 AE IntegriLok IM 100 - Min. 26GA Nailstrip Report - CSS.pdf Created by Independent Third Parry: Yes Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1624 The State of Florida is an AA/EEO employer. copyright 2QQ7-24E3 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. It you do not want your e-mail address released in response to a public -records request, do not send electranic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -pursuant to Section 455.275{1), Florida Statntes, effective October 1, 2012, IirEnsees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official cammunlcation with the licensee. However email addresses are public record. It you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here. Product Approval Aooepts: ® eCe_ Credit Card Safe 2460 B Piper Drive I L-4 Vero Beach, Fl. 3 561-293-1407 INTEGRITYMETALS Compliant with Florida Building Code 2017 (61fi ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant Active Quality Assurance Program Product: IntegriLok iM 100 Series - Min. 26GA Steel 1.0 Nailstrip Roof Panel FBC Sec.1507.4.2 Yield strength: 5oksi IV Coverage (Max.) Rib Height 7/S" Minimum 15/32" plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. W penetration thru plywood supports 24" max. o.c. Corrosion Resistant Compliant: FBC Sec. 1S07.4.3 Fastener; #10 x 1" fastener spaced @ 10" O.C. Underlayment: To be compliant with FBC Sec.1507, Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. Install Details: Table A Allowable Loads Method 1: DESIGN PRESSURE* - 86 PSF SPACING 10" O.C. ADHEISIVE EVERY OTHER NAIL SL OT IN THE NAIL FIN Intertek Testing (TST-1S27) Reference Data: REPORT # 17726.054 50-44 RO** UL 580-06 *Design Pressure safety margin of 2.1 **This test report is owned by Quality Metal Roof Fabricators. integrity Metals has been given written authorization by Quality Metal Roof Fabricators to shore testing_ certincate m inoepenoence: Locke Bowden, P.E. does not have, nor will acquire a financial iriterest in any company manufacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributing products under this report. 't,11111frrrrr 6900.4 v10E1VS6 / / = No .49704 seal + a� sr TE or ORION .,���/pNA +1E� Integrity Metals: IntegriLok IM 100 -Min. 26GA Steel 1.0 Nail Strip Panel Installation Details Limitations: 1. Underlayment to be compliance with current Florida Building Cade (FBC)2017 GTH ed.. see Chart 1507.1,1 2. Minimum slope to be compliant with Florida Building Code 2017 a ed., and per with Manufacturer's instaliatron reference. 3. Products are compliant with State of Florida product approval per RuLe 61G20-3. Compliance Method: 1-13 4. Engineering analysis for "project specific approval by local authorities wrurisdiction is allowed by other registered engineers- S. Fire classification is not part of this acceptance_ Smear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6P ed , Chapter 22 Steel, Chapter 23 Wood and Chapter 16 Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report_ PROFILE lit 3/4„ �,44i'llff ♦4 E • 09, V ��0 • 7 , f • * ' FASTENER PATTERN ALONG VERTICAL SEAM: SfA� OF P , �'.�,x�'. '0 LQ+O.C���� FASTENED LLD 5-1/4" U.C. FAST94'W�KM46tf CORROSION RESISTANT COMPLIANT WrrH FBC 2016 SEC.1506.6 & SEC 1507.4.4 lid 16" .a ..aa z "_ff ZOO A, 2Mt Timbodake Cove, LLC OnW E Eng. PE ant mebis 3324 W Univ Ave. ON FL PE L:- Na 81377 Rojmt FL 28113 Revision Gamvft FL 326D7 FL CA Ur- W 33344 Data: 27Feb2U v2r Vv< wa Page 1 of 1 Validation of Product Compliance Prepared For Integrity Metals, LLC (Client) Integrity Metals, LLC, operating at 2604 Piper Dr_ Suite B, Vero Beach FL, has submitted test reports and documentation for a revision to FL 28113, the IM100 IntegriLok metal roof panel. This revision has been evaluated and validated by independent licensed engineers as required by Rule fit G20-3 and is pending (final review and publication by the Florida Building Commission. This revision includes additional test data for an installation condition and maximum allowable uplift listed below: Method B: 108.5psf I Use self -adhering underlayment and install fasteners in every hole (+-5" o•c.). Factor of safety of 2.0 has been applied to calculate the allowable load listed. Compliance Statement: This product, distributed under FL 28113 has been tested as required and has demonstrated compliance with Florida Building Code 2017, Section 1504.3.2- ,l�1t�trtirrra���i E• %,1GENS, •.0 i r� 2q retrT., Z.'. No. 81377 Q7 TATE 0 �w1~ IONAL David Timberlake Cove, LLC PE Lic. No- 81377 CA Lic_ No: 33344 Tim rtake Cove