HomeMy WebLinkAboutDrawing.Sb A 25U
REPLACE DOOR IN 1 OPENING ONLY.
NEW DOOR TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED.
OPENING
PRODUCT
DESIGN
OPENING
SQ.
WIND
PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO. WIDTH. HGT.
FTG,
ZONE
POS. NEG.
(N.O.A. #)
POS. NEG.
1 36 80
20.00
5
36.1 -47.2
FL20468.7
50.0 -50.0
FRONT ENTRY - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS.
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 1/4" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 1/4" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 10 FT 11 IN
CARPENTER RESIDENCE
7507 SANTA ROSA PARKWAY
FORT PIERCE, FLORIDA