HomeMy WebLinkAboutHUSTON PLANH G F E D C B A 8 7 6 5 4 3 2 1 H G F E D C B A 8 7 6 5 4 3 2 1 MAX. WIDTH: MIN. DEPTH: 18’8" SHAPE: FILL FROM EXCAVATION: TILE:FILTER: PUMP HP: LIGHTS: TRNFORM: MAIN DRAIN: SKIMMER: RETURNS: VALVED VAC LINE: DISCHARGE LINE: CHLORINATOR: HANDRAIL: DIVING BOARD: HEATER: VACUUM HEAD: VACUUM HOSE: LEAF SKIMMER: TREE / STUMP REMOVAL: REMOVE EXISITING CONCRETE: PUMP POOL PATIO: ELECTRICAL: POOL PATIO: EXISTING PATIO: DECK DRAIN: POOL CAPACITY: TURN-OVER RATE: TERMITE TREAT:BARRIER: MAX. LENGTH:30’ 3.5’MAX. DEPTH:6’ CUST HAUL ELEVATION:TBD INTERIOR FINISH:GEM CS200 POOL SPA POOL 2 COLOR LED SPA NA POOL SPA POOL 2 SPA NA 1 POOL 3 SPA NA JETS:POOL NA SPA NA INCL FILL LINE:NA TO GROUND TRUCLEAR SALT SYSTEM NA LADDER:NA NA SLIDE:NA NA INCL INCL INCL POLE: BRUSH: TEST KIT: INCL INCL INCL NA NA SCREEN ENCLOSURE: ED’S ELECTRIC CONCRETE FLOCRETE INCL 6-HRS. INCL DOOR WINDOW ALARMS NA MAX. WATER VELOCITY: MIN. SKIMMER FLOW: SURFACE AREA OF POOL: SPECIFICATIONS NA 100 WATTS NA PAVERS REMAIN PUMP MAKE PER FBC 4501.20 2.7HP VS FLOPRO FILTRATION PUMP COMPLIANT WITH ANSI/APSP/ICC-15 2011 GENERAL NOTES: 1. SWIMMING POOL CONSTRUCTION TO COMPLY W/ FLA. BLDG. CODE AND WITH ALL LOCAL ORDINANCES AND ZONING REGULATIONS. 2. SWIMMING POOL TO BEAR ON ROCK OR UNDISTURBED SAND. ALL WALLS AND FLOORS SHALL BE GUNITED OR POURED IN-PLACE CONCRETE W/ MINIMUM 3,000 P.S.I. CONCRETE (@ 28 DAYS) COMPRESSIVE STRENGTH. 3. ENGINEER SHALL BE NOTIFIED IF SOIL BEARING LESS THAN 2500 P.S.F., OR MUCK, SILT OR LOOSE, SOFT SOIL IS FOUND. A SOIL BEARING CAPACITY OF 2,500 P.S.F. HAS BEEN USED IN THE DESIGN. 4. REINFORCING BARS SHALL BE NEW BILLET, GRADE 40. 5. ALL POOL PIPING TO BE P.V.C. SCHEDULE 40 MIN. AND BEAR THE N.S.F. APPROVAL. 6. BACK-WASH SHALL BE IN COMPLIANCE WITH LOCAL ORDINANCES. 7. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES. SURFACE GRADING SHALL CONTAIN WATER WITHIN PROPERTY LINES. PONDING SHALL NOT PERSIST FOR MORE THAN ONE HOUR. 8. WATER SUPPLY & DISPOSAL SHALL BE INSTALLED SO THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM. 9. GRATE AT MAIN DRAIN SHALL HAVE A FREE AREA OF 4X THE AREA OF THE SUCTION LINE 10. HAIR & LINT STRAINERS SHALL HAVE A REMOVABLE SCREEN W/ A MINIMUM FREE AREA OF 3X THE AREA OF THE SUCTION LINE. 11. ELECTRICAL: INSTALL WIRING & DEVICES AS SHOWN IN "POOL DATA" HEREON. LIGHT CONNECTION TO CONFORM TO NATIONAL ELECTRICAL CODE- LATEST EDITION. 12. ALL METALLIC CONDUITS, PIPING SYSTEMS, REINFORCED STEEL, LIGHT FIXTURES & HOUSING, METAL PARTS OF LADDERS, HANDRAILS, DIVING BOARDS & SUPPORTS TO BE BONDED TOGETHER & GROUNDED TO A COMMON GROUND. BONDING CONDUCTOR SHALL NOT BE SMALLER THAN #8 COPPER. 13. NO OVERHEAD OPEN WIRE OVER POOL WATER. 14. CARTRIDGE FILTER SHALL HAVE A FILTRATION RATE NOT TO EXCEED 3 G.P.M. / S.F. OF FILTER AREA. NO BACK-WASH REQUIRED. 15. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTOR SHALL VERIFY LOCATION OF ELECTRICAL SERVICE BY F.P.&L. COMPANY. 16. SPECIAL ATTENTION SHALL BE GIVEN TO EXISTING FOUNDATION TO PREVENT UNDERMINING. 17. PLANTER SPECIES SHALL BE SELECTED WITH NON-INVASIVE ROOT SYSTEMS (SPECIES SELECTION BY OTHERS). AARON H. ALLEN PE, FL REG. NO. 86620 FL A. ALLEN ENGINEERING LLC, CA NO. 33042 2367 7TH STREET, LA VERNE, CA 91750 TO THE BEST OF MY KNOWLEDGE, THESE DRAWINGS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES 13,295-GAL. SPA CAPACITY:NA 6 FPS FROM TRUNK 25 GPM 396 SQFT. PERIMETER OF POOL: 82 LINFT SEAL: BUILDER/JOB NAME: PERMIT NO.: DATE DRAWN: TBD 08/05/2020 DRAWN BY: CHECKED BY: APPROVED BY: HUSTON, DEBORAH ADDRESS:2680 CONIFER DRIVE DAVE CURLAND AARON H. ALLEN SCALE:¼” = 1' CITY:FORT PIERCE, FL 34951 JOB INFORMATION PIONEER SECTION THRU POOL 1 AScale: NTS WALL THICKNESS REQ.4 AScale: NTS TYP. WALL SECTION & WELL PT.5 AScale: NTS POOL DRAIN TYP.6 AScale: NTS EQUIPOTENTIAL BOND GRID 7 AScale: NTS WATER BONDING 8 AScale: NTS ELECTRICAL SCHEMATIC 7 CScale: NTS W.L. #8 SOLID COPPER BOND WIRE W/ APPR. CLAMPS (SEE NOTE 3) 8 GAUGE SOLID COPPER WIRE SOIL 18" MIN. (ENTIRE PERIMETER) NOTES: 1. MINIMUM 18" FROM ENTIRE EDGE OF POOL PERIMETER BURIED 4" TO 6" DEEP 2. INSTALL PER N.E.C. 2017 SEC. 680.26 (WHERE ADOPTED) 3. #8 SOLID COPPER BOND WIRE WITH APPROVED CLAMPS ON EACH SIDE OF POOL (4 TOTAL) DECK PER DETAIL A/5 ANSI-7/ANSI-15 8 EScale: NTS POOL DRAIN CERTIFICATION 7 EScale: NTS EQUIPMENT LAYOUT 7 GScale: NTS UNDERWATER LIGHT 8 BScale: NTS PUMP CURVES 7 HScale: NTS SHORING REQUIREMENTS 3 AScale: NTS SOIL EQUIPMENT PAD PB-2008 BONDING WIRE TO GRID VARIESNOTE: 1. PB-2008 TO BE INSTALLED NEAR OR UNDER EQUIPMENT PAD FROM POWER SUPPLY POOL FINISH APPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, RAILS & EQUIPMENT 1" LIGHT CONDUIT WATER LEVEL NICHELESS UNDERWATER LIGHT 18" MIN.EXIST. FTGN. SOIL 3 ft. 6 ft. 9 ft.5 ft.4" WALL #3 REBAR @ 12" O.C.E.W.ANGLE OF REPOSENOTES: EXCAVATION INTO ANGLE OF REPOSE ALLOWED IF: 1. SHORING IS SUFFICIENT TO SECURE SOILS FROM EROSION/SETTLEMENT 2. NO UNDERMINING OCCURS UNLESS APPROVED BY ENGINEER 3. COMPACTION TEST PROVIDED AT C.O. 6" WALL #3 REBAR @ 12" O.C.E.W. 8" WALL #3 REBAR @ 12" O.C.E.W. 2"X4" @ 24" O.C. ½" PLYWOOD NOTE: 1. SHORING TO BE INSTALLED WHEN POOL SHELL IS CLOSER THAN 5 FT TO HOME, OR EXCEEDS THE ONE TO ONE RATIO OF THE ANGLE OF REPOSE EXIST. FTGN. SOIL < 5' OR 1:1 S.P.S.T. TOGGLE SWITCH #8 SOLID CU GROUND WIRE TO EXISTING PANEL 40 AMP POOL PANEL W/(3) - #4 THHN CU WITHIN 1” ELECTRICAL CONDUIT (X) POOL LIGHTS (GFI NOT REQUIRED) VARIABLE SPEED PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU WITH-IN ½” CONDUIT TIME CLOCK W.P. DISCONNECT MAIN DRAIN SKIMMER COLOR LED VACUUM LINE SYMBOL LEGEND DECO DRAIN EXISTING FACILITY CHANNEL DRAIN ELEVATION MARKER B BUBBLER JANDY UPLIGHTUL DOOR/WINDOW ALARM BABY BARRIER XX.X’ DECK PER DETAIL A/5 x0 ft.2 ft. 4.8 in.4 ft.8 ft. REVISION DATE:NA · APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE TO 8FPS SUCTION LINES,10FPS MAX RETURN SWIMOUT CUT SECTION 8 HScale: NTS 20" MAX. 18" 8880 GLADES CUT OFF ROAD PORT ST. LUCIE, FL 34986 CUSTOMER APPROVAL: REVISION NOTE: 1. WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 6 P1 W F V S 5 4 B NOTES: 1. ALL ELECTRICAL TO COMPLY WITH 2017 NATIONAL ELECTRIC CODE. 2. 3-#12 THHN CU WITHIN ½” MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) 5. INSTALL 125V 15 AMP WEATHERPROOF DUPLEX GFCI RECEPTACLE AT LEAST 10' AWAY AND NOT MORE THAN 20' FROM THE INSIDE WALL OF THE POOL 6. POOL PANEL AND SWITCHES MUST BE AT LEAST 5' FROM THE INSIDE WALL OF THE POOL 7. PROVIDE PROPER WORKING CLEARANCE SPACES FOR ELECTRICAL EQUIPMENT AS PER HO-26 OF NFPA 70 REC. PUMP/WATER FEATURE PUMP = 2.7 HP V.S. FLOPRO LOW SPEED: 36 GPM MAX HIGH SPEED: 117 GPM @ 48 TDH 2.5" SUCTION PIPE @ 117 GPM: 7.98 FT/SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" PRESSURE PIPE @ 117 GPM = 7.98 FT./SEC. (10 FT./SEC. MAX. – PRESSURE LINES) 200 SQ. FT. CARTRIDGE FILTER X 0.375 = 75 GPM BACKWASH VALVE NO DOCUMENT PROPERTY OF A. ALLEN ENGINEERING INC. & A&G CONCRETE POOLS INC., DUPLICATION AND/OR DISTRIBUTION IN PART OR WHOLE WITHOUT WRITTEN CONSENT FROM THE OWNER(S) WILL BE PUNISHABLE UNDER AWCPA COPYRIGHTS LAWS. KEY: 1. 2.5" RETURN LINE TO POOL 2. 2" SUPPLY LINE TO BUBBLERS 3. 2" SUPPLY LINE TO SHEER DESCENT 4. 1.5" VACUUM LINE 5. 2" SKIMMER LINE 6. 2.5" MAIN DRAIN LINE P1. 2.7HP VS FLOPRO WITH W/APPR HAIR AND LINT STRAINER F. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE (MUST HOLD 35 PSI FOR 30 MINUTES MINIMUM) W. 1.5" TO WASTE OR TO GROUND V. VALVES (TYP) B. PB-2008 WATER BONDING TO GRID (SEE DETAIL A/8) S. JANDY “TRUCLEAR” SALT SYSTEM TYP. FOOTER SECTION 2 BScale: NTS HANDRAIL BONDING 7 BScale: NTS NOTE: 1. WHERE APPLICABLE PER NATIONAL ELECTRICAL CODE #8 GROUND WIRE DECK PER DETAIL A/5 2.5" SUCTION LINE MAX 117 G.P.M. TO FILTRATION PUMP 3" PLUMBING LINES FROM SUMP W/ 3" TEE 3 FT. MIN. 6 FPS MAX 8 FPS MAX WATERWAY MAIN DRAINS MIN. 3' SEPARATION REQ. NOTES: 1. APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 (SEE CERT. OF COMPLIANCE) - COVERS MUST BE REPLACED EVERY 5 YEARS 2. APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6TH EDITION AND THE ANSI/APSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE 8" (1) #5 OR (2) #3 REBAR(S) CUT SECTIONTOP VIEW 8" 8" Eq.VARIESNOTE: 1. STEEL REINFORCEMENT IN CONCRETE AGAINST EARTH SHALL HAVE A MINIMUM COVER OF 2" Eq.Eq. Eq. 4" 6"X6" TILE INTERIOR FINISH CONCRETE #3 @ 12" O.C.B.W. TO PUMP THREADED PLUG SECURED GRATE TOOLS REQUIRED FOR REMOVAL GRAVEL BED NOTES: 1. REMOVE GRATE & WELL POINT PLUG FROM MAIN DRAIN & ATTACH AUX. PUMP LINE WHEN EMPTYING POOL 2. FOR DEPTHS GREATER THAN 6' ADD 1- #3 COVE BAR @ 6" O.C. 3. SLOPE DECK ¼” PER FOOT 4. 2500 PSI FIBER REINFORCED PUMP MIX CONCRETE 4" COMPACTED SOIL ACCESSSUNDECK WITH BUBBLERS AND UMBRELLA SLEEVE *LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 PAVERS REMAIN GLASS STEP EDGE TILE 3.5' DEEP DECO DRAIN 6' DEEP SKIMMER VAC LINEGLASS STEP EDGE TILED BENCH COVERED LANAI 13' X 30' POOL +12"+6"CONCRETE FLOCRETE 26 ft.40 ft.3 ft.5 ft.7 ft.3 ft.13 ft. 2 in.5 ft. 6 in.11 ft. 30 ft.10 ft.COLOR LED COLOR LED +6" 36" SHEER DESCENT OVERFLOW LINE 30' 0 FLOOR SLOPES #3 STEEL @ 12" O/C E.W. WATERLINE TILE MAIN DRAIN 5' X” 6' 3'6" SUNDECK 12" MAX 4-½” 12" MAX 12" MAX 10" MIN. STEP NOTES: 1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. 4. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY NOTES: 1. (5.6.1) THE SLOPE OF THE FLOOR FROM THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 FEET TO THE POINT OF THE FIRST SLOPE CHANGE 2. (5.6.2) CHANGES IN SLOPE BETWEEN SHALLOW AND DEEP AREAS SHALL BE AT A MINIMUM WATER DEPTH OF 2 FEET 9 INCHES AND BE AT LEAST 6 FEET FROM THE SHALLOW END 3. (5.6.3) THE SLOPE OF THE FLOOR FROM THE POINT OF THE FIRST SLOPE CHANGE TOWARD THE DEEP END SHALL NOT EXCEED 1 FOOT IN 3 FEET 4. WALLS SHALL NOT SLOPE > 11 DEGREES 5. HAND HOLD TO BE INSTALLED WHERE DECK RAISED +6" ABOVE POOL 3' W.P. DISCONNECT SALT SYSTEM W/BUILT IN OVERLOAD SWITCH W/3-#10 THHN CU WITH-IN ½” CONDUIT 21 R R R 30" CLEARANCE IN FRONT OF SUBPANEL F P1 SALT 2.5" 1.5" 1.5" 1.5" 1.5"1.5" 2" 1.5"1" 2"1.5" 2" DECK PER DETAIL A/5 COMPACTED SOIL +6" +12" 5 B CONCRETE DECK RISER Scale: NTS PROVIDE HAND HOLDS AS REQUIRED ANSI/NSPI-5-2003 OR MAINTAIN 4" GRABBABLE SURFACE (DETERMINE IN FIELD) 3 3" 3" 2.5"2" UMBRELLA SLEEVE