HomeMy WebLinkAboutEngineering; Proposed Utility StructurePRODUCT CATEGORY STRUCTURAL COMPONENTS STRUCTURAL COMPONENTS APPROVED PRODUCTS LIST SUB CATEGORY ROOF DECK STRUCTURAL WALL SIDE POSTBOW RAFTER FRAMING PLAN SCALE: 1W =1' SIDE ELEVATION SCALE: 1/8' = 1' NOSCREWS REQUIRED IN BOW BEND 5 RAFTER MANUFACTURER CAROLINA CARPORTS, INC. 26 Gauge AG Panel CAROLINA CARPORTS, INC. 26 Gauge AG Panel 24' 16 GA U-CHANNEL BRACE (5' TO T POST) 48' 16 GA U-CHANNEL BRACE (8• TO 14' POST) BRACE ANGLE SHALL BE MIN. 45' TO MAX. 60' FROM HORIZONTAL 3' `W LONG TS NIPPLE SECURE RAFTER AND POST TO NIPPLE WITH (4) #12-14 x 314' TS RAFTER POST SELF -DRILLING FASTENERS BOW RAFTERIPOST DETAIL � � iNot TO Scale NIPPLE TO BASE RAIL OCCUPANCY CROUP: U GENERAL NOTES: CONSTRUCTION TYPE: II-B I. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS. FINISH FLOOR ELEVATION AND RISK CATEGORY: II APPROVAL SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. No. & DATE BUILDING ENCLOSURE TYPE: ENCLOSED 2 THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS. OR OTHER WIND EXPOSURE CATEGORY: C FL6596.1-R5 COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS, INC., WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BEAT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC.. SHALL NOT BE RESPONSIBLE FOR ULTIMATE WIND SPEED (MPH): 160 10/10/17 STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. NOMINAL DESIGN WIND SPEED (MPH): 124 FL6702.1-R5 3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. 10/10/17 MEAN ROOF HEIGHT (FEET): 1225 4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. ROOF ANGLE (DEGREES): 14.0 5. ALL FIELD FRAMING CONNECTIONS SHALL BE #12-14x 3W SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. DESIGN PRESSURES (PSF): 6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB INTERNAL PRESSURE COEFFICIENT: +0.181-0.18 FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116. ROOF: ZONE1: +1.0/-29.5 7. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LOT 1/2' x 5' OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE MODEL HSA 1260, OR ZONE 2: +16.0 /-01.5 EQUIVALENT. ZONE 3: -16.01-65.6 DESIGN ROOF PRESSURES: +16.01.39.1 8. POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS. 'WALLS: 9. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING ��jjy� CODE SIXTH EDITION (2017)-RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017) - BUILDING. MINIMUM ALLOWABLE ZONE5THe Co+ -304/-37.0 FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED. DESIG ROO91 F P SSURE " +30.4 /-35.0 10. 14 GA FRAMING: 2-1/2' x 2-1/2' TUBE STEEL (TS) WITH 2-1W x 2-1/4' TS NIPPLES. - go Ir L 12 GA FRAMING: 2-1/4'x 2-1/4'TS WITH T x T TS NIPPLES. sue==t- 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS 12 Q3 24.16 GA U-CHANNEL BRACE FASTENEDTORAFTERIMTH (2) #12.14 x WP SELF-0RRLNG SCREWS AT EACH END (4 PER BRACE) TYPICAL INTERIOR POST/RAFTER FRAMING PLAN SCALE: 1/8' = T 6' LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) 012-14 x 3W SOPS RAFTER POST INSTALL 112'x MINIMUM TTAPCON REDHEAD LOT COC p9&4pMh%NCE ANCHOR OR 1/T x MINIMUM 5-1/2' EXPANSION ANCHOR THROUGH BASE RAIL WITHIN WOF EACH STe L.UCIE COUNTY RAFTER POSTS ALONG SIDES AND EVERY END WALL POST ALONG END WALL SECTIONS BOVVNN 1-�}-MIN. 6' 2-1/2' EMBEOMENT CONTINUOUS 4' CONCRETE BASE RAIL ANCHORAGE 1 Not Ta Scale FRONT & REAR ELEVATION SCALE: 1/8' = T CONTINUOUS BASE RAIL POST/BASE RAIL CONN. DETAIL 1.112' x 1-1/2' x 2' 16 GA CLIP ANGLE SECURE TO RAFTER POST AND GABLE RAIL WITH (4) #12-14 x 3/4' SI TOP AND BOTTOM 1-1/2' x 1-1/2' x 2' 16 GA CLIP ANGLE SECURE TO RAFTER AND GABLE RAIL WITH (4) 412-14 x 3/4' SDFS, (2) ON TOP, (2) ON BOTTOM 6' LONG TS NIPPLE SECURE RAFTER AND POST TS GABLE RAIL TO NIPPLE WITH (4) #12-14 x 3/4' SELF -DRILLING FASTENERS t RAFTER POST GABLE RAIL TO RAFTER POST CONNECTION DETAIL •+ NM Ta Swle METAL FRAMING AND SIDING PREFABRICATED B CAROLINA CARPORTS, INC. P.O. BOX 1263 DOBSON, NORTH CAROLINA 27017 THESE ENGINEERING DRAWINGS ARE THE PROPERTY OF BECHTOL ENGINEERING & TESTING, INC. AND CAROLINA CARPORTS, INC. THESE DRAWING MAY NOT BE REPRODUCED WITHOUT THE WRITTEN CONSENT OF BECHTOL ENGINEERING & TESTING, INC., AND CAROLINA CARPORTS, INC. THIS IS TO CERTIFY THAT THE CALCUfATIONSAND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE, SIXTH EDITION 120M. THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING CODE. RAFTER BECHTOL ENI 605 WEST NEW YO AND. FL RECEIVED DELficae ofORIDA DEC 0 2 2019 Thomas tol, P. ST. Lucie County, PerMItting P.M. Ucens o.: \\111111111//// .``\,.BPS • R-•H• BF� PROPOSED UTILITY STRUC 2921 DAME ROAD FORT PIERCE, FLORIDA TB BECHTOL ENG/NEER/NG M� ME AV AND TE37TAfa em. mamxo am�w+. oNRea6xrA, uo 1Auoa4x lrsw Drama =� o.xre,uw.�namae '^'^'m TB NO.38538 3TA % I 5 TE OF ONAL T 100 11/25/19 NTS _ G19001 SHEET OF