HomeMy WebLinkAboutProduct Approval; Roof Deck Structural ComponentsFlorida Building Code Online Page 1 of 2
in
Business & ProfessionalRegulation
rA
MIS Home I Log In i User Regisbs ion I Hot Topico I Submit Surcharge I Scats Is Facts I Publications I Contest Us I MIS site Map I Irks 1 searan
db Product Approval
USER: Public User
Product Aooroval Mme > Product or Anolication See" > ADDllfation List > Application Debit
FL #
FL6596-RS
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived ❑
Product Manufacturer Carolina Carports,Inc.
Address/Phone/Email 187 Cardinal Ridge Trail
Dobson, NC 27017
(336) 367-6400
FLvalidation@yahoo.com
Authorized Signature Tim Gammons
tim. ga@caroli nacarpo rts.conh
Technical Representative Jason Cope
Address/Phone/Email 187 Cardinal Ridge Trail
Dobson, NC 27017
(800) 670-4262 Ext 2037
jason.c@ccihq.biz
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Terrence E. Wolfe
the Evaluation Report
Florida License
PE-44923
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/05/2027
Validated By
Brian Jaks, P.E.
® Validation Checklist- Hardcopy Received
Certificate of Independence
FL6596 RS COI Letter of Certification.odf
Referenced Standard and Year (of Standard)
Standard
ASTM E 1592 -
FM 4471
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2005
1992
https://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgtLgar tWIPgd... 12/17/2019
Florida Building Code Online
Page 2 of 2
Product Approval Method Method 1 Option D
Date Submitted 08/15/2017
Date Validated 08/16/2017
Date Pending FBC Approval 08/22/2017
Date Approved 10/10/2017
Summary of Products
FL #
Model, Number or Name
Description
6596.1
AG Panel
26 Ga AG Roof Panel over open framing
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6596 RS 11 26 Ga. AG Roof Panel secured.Ddf
Approved for use outside HVHZ: Yes
Verified By: Terrence E. Wolfe, PE. 44923
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +57.3 psf/-62.5 psf
Evaluation Reports
Other: See Evaluation Report for various design pressures.
FL6596 RS AE 26 Ga. AG Roof Panel secured.odf
Created by Independent Third Party: Yes
Install per manufacturer's details. Notfor use in HVHZ Zones.
6596.2
AG Panel
29 Ga. AG Roof Panel over open framing
Limits of Use
(HVHZ:
Installation Instructions
Approved for use in No
FL6596 RS 11 29 Ga AG Structural Roof Panel NON HVHZ
secured.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +4,1.6 psf/-57.3 psf
Created by Independent Third Party: Yes
Other: See Evaluation Report for various design pressures. '
Evaluation Reports
Install per manufacturer's details. Not for use in HVHZ Zones.
FL6596 RS AE 29 Ga AG Structural Roof Panel NON HVHZ
secured.DdF
Created by Independent Third Party: Yes
Back xeat
497-1814
The State of Florida Is an WEED employer. Coovneht 2007-1013 state or nonda.:: Pmaev Statement:: Accessib8ity Statement :: Refund Statemen
Under Florida law, email addresses are public hil If you do not want your e-mail address released In response to a public-ramrds request, do not send elenranlc
mail to this entity, Instead, contact the office by phone 4r by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, Ikensees licensed under chapter 455, F.S. must provide the Department with an email address if they Have one. The
smalls provided may be used for official commureatlon with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To detem ire if you are a licensee under chapter 455, F.S., please
product Approval Accepts:
y Cfedli (Mara
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtLgagtWIPgd... 12/ 17/2019
Force Engineering &Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338.
Product Evaluation Report
CAROLINA CARPORTS, INC.
26 Ga. AG Roof Panel over open framing
Florida Product Approval # 6596.1 R5
Florida Building Coder2017
Per Rule 611320-3
Method: 1—D
Category: Structural Components
Subcategory: Roof Deck
Compliance Method: 61G20-3.005(1)(d)
NON HVHZ
Product Manufacturer.
Carolina Carports, Inc.
187 Cardinal Ridge Trail
Dobson, NC 27017
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validator:
Brian Jaks P.E. 470159
Contents:
Evaluation Report Pages 1-4
`,,tttu rrirr��.
0
cE1rSF�,��,
No. 40 /
\J ,a • STATE OF : a
OR194. �4
•an
FL# 6596.1 R5
Aup,ust 14, 2017
Force Engineering & Testing Inc.
19530 Ramblewoad Drive
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2, 1504.7.
Product Description: AG Roof Panel, 26 Ga, Steel, 36" Wide, through fastened structural roof panel.
Structural Application.
Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida
Building Code 2017 Section 1507.4.3. Optional paint finish.
Yield Strength: Min. 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2017, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.0185" min. order thickness
Width: 36" maximum coverage
Rib Height: _ %" major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #12-14 x'Y.." HWH SD#3 with 5/8" (16mm) diameter sealing washing or approved
equal.
Corrosion Resistance:. Per Florida Building Code 2017, Section 1507.4.4.
Substrate Description: Minimum 14 Ga. (Grade 50) Steel tube framing or Minimum 18 Ga. (Grade 50)
Steel hat channel purlins/gins. See Table A for steel gauge. Framing must be
designed in accordance w/ Florida Building Code 2017.
Allowable Design Pressures:
Table "A"
Maximum Design Pressure:
-59.9 psf
-62.5 psf
-83.3 psf
+46.9 psf
+57.3 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
5'-0" O.C.
4'-0" O.C.
4'-0" O.C.
5'-0" O.C.
4'-0" O.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 18 Ga. Steel
Framing
Min. 14 Ga. Steel
Framing
Min, 18 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
-Design Pressure includes a Safety Factor= 2.0.
J� ,ACE £, .Wo If
O E N'S
• •d • STATE OF : q
�iO^` • `pL OF I
A ••�rr�
. swoQl6sas ice, SS • . •�(j ;�` ,
•xm !40! O SH {{{{N```s
FL# 6596.1 R5
August 14, 2017
Forc7En�ineering & Testing Inc.
19530 Remblewood Drivc
Humble,TX 77338
Code Compliance:
The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section 1504.3.2, 1504.7.
Evaluation Report Scope:
The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61G20-3.
Performance Standards:
The product described herein has demonstrated compliance with: _
• ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
• FM 4471-92 - Foot Traffic Resistance Test
Reference Data:
1. ASTM E 1592-05 Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 183-0063T-16A-E
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization 9TST-5328)
Report No. 183-0109T-12, & 183-0142T-15
3. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing; Inc.
(FBC Organization #ANE ID: 1920)
Test Standard Equivalency:
The ASTM E 1592-05 test standard is equivalent to the ASTM E 1592-05 (2012)
test standard.
The FM 4471-10, Foot Traffic Resistance test standard is equivalent to
FM 4471-92.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
NkCIE E,
I C E N S
•�� ." No. 44923
w l.!�'f�it�—� �cC • �
^+' STATE OF : q
0'K' AL 0x11) �4 �
FL# 6596.1 R5
August 14, 2017
Force Engineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77339
Insulation: Manufacturer's approved product (Optional)
Roof Panel Fire Classification: I Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
FL# 6596.1 R5
,`SO1[rlr rJ11're
N,C E, ,F. ft,
�•��VICEMSF<e:
lie(ate
STATE OF ;
zn.�rms 'o� FL 0 R1 9
Fs '
imm ,,', �� O I+r l I r 1 N?C0%
August 14, 2017
Immimm
OR MEN. 14: " (GRAqE, 60) STEEL TUBE FRMW
(SEE TABLE'A FOR SWNG)
1/4' W14 SDJ3 W1 6/8? (16m.) -DWMETER srAuuo wAm
suip,olp "-'
QOA.,'
own
A.ugust-14,2017
Florida Building Code Online
Page 1 of 2
Professional Regulation
r�ra:asm
SOS Home I lag In I User Reglsmotion I Hot Topks I Submit Sumharge I Stats&Facts I Publicagons I Corned Us I SOS Ste Map I Links Seardn I
ogpr)f;aJlProduct Approval
USER; Public User
Product Approval Menu > Protluct or Avolication Search > Aoolication List > Appbcatum Detail
FL # FL6702-R5
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived ❑
Product Manufacturer Carolina Carports,Inc.
Address/Phone/Email 187 Cardinal Ridge Trail
Dobson, NC 27017
(336) 367-6400
FLvalidation@yahoo.com
Authorized Signature Tim Gammons
tim.ga@mrolinacarports.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Structural Wall
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Terrence E. Wolfe
PE-44923
Keystone Certifications, Inc.
03/14/2027
Brian ]aks, P.E.
0 Validation Checklist- Hardcopy Received
FL6702 R5 COI Letter of Certifcation.odf
1709.2
Method 2 Option B
08/15/2017
https://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEVXQwtDgtp 1 oPj b8uS3... 12/ 17/2019
Florida Building Code Online
Page 2 of 2
Date Validated 08/17/2017
Date Pending FBC Approval 08/21/2017
Date Approved 10/10/2017
Summary of Products
I 1i
FL #
Model, Number or Name
Description
6702.1
AG Panel
26 Ga. AG Wall Panel over open framing
Limits of Use
Installation Instructions
'Approved for use in HVHZ: No
FL6702 PIS II 26 Ga. AG Wall Panel - Secureci
Verified By: Terrence E. Wolfe, PE. 44923
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Parry: Yes
Design Pressure: +57.3 psf/-62.5 psf
Evaluation Reports
Other: See Evaluation Report for various design pressures.
FL6702 PIS AE 26 Ga AG Wall Panel - Secured odf
Created by Independent Third Party: Yes
Install per manufacturer's details. Not for use in HVHZ Zones.
6702.2
AG Panel
29 Ga. AG Wall Panel over open framing
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
F1,6702 I 29 Ga, AG Structural Wall Panel ON HVHZ -
Secured.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +41.6 PSF/-57.3 PSF
Created by Independent Third Party: Yes
Other: See Evaluation Report for various design pressures.
Evaluation Reports
Install per manufacturer's details. Not for use in HVHZ Zones.
FL6702 R5 AE 29 Ga. AG Structural al Panel NON HVHZ
Secured.Ddf
Created by Independent Third Party: Yes
6702.3
Dutch Lap Panel
26 Ga. Dutch Lap Wall Panel over open framing
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6702 IRS 11 Dutch Lap Metal Wall Panel NON HVHZ
Secured.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +24.4 psf/-26.0 psf
Created by Independent Third Party: Yes
Other: See Evaluation Report for various design pressures.
Evaluation Reports
Install per manufacturer's details. Not for use in HVHZ zones.
FL6702 R5 AE Dutch Lap Metal Wall Panel NON HVHZ -
Secured odf
Created by Independent Third Party: Yes
6702.4
Dutch Lap Panel
29 Ga. Dutch Lap Wall Panel over open framing
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL6702 R5 IT Dutch Lap Metal Wall Panel non hvhz
secureci
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +35.1 psf/-35.5 psf
Created by Independent Third Party: Yes
Other: See Evaluation Report for various design pressures.
Evaluation Reports
Install per manufacturer's details. Not for use in HVHZ zones.
FL6702 RS AE Dutch Lap Metal Wall Panel non hvhz
secured.Ddf
Created by Independent Third Party: Yes
Back Neat
compact Us 2601 Blair Such, Road. Tallahassee FL 32399 Pimsme 850,487,1824
Tire Scare of Florida is an WEEO employer. CooMoht 2007-2013 State of Florida, :: Pnvacv Statement :: Accessibility, Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic
mail to this entry. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.'Pursuant to Section 455.275
(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Des, rtment with an email address If May have one. The
emails provided may be used for oRual communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please pmvide the Department with an email address which no be made available to We public To determine if you are a licensee under Chapter 455, F.S., please
click here .
Product APProval Accepts:
® ® ® Mi
lCt'W'I ly \{} I IlIC1
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtp 1 oPjb8uS3... 12/17/2019
r:�r:7t�
oeering &Testing Inc.
19530 Ramble,vood Drive
Humble,TX 77338'
Product Evaluation Report
CAROLINA CARPORTS, INC.
26 Ga. AG Wall Panel over open framing
Florida Product Approval # 6702.1115
Florida Building Code 2017
Per Rule 61G20-3
Method: 2 —B
Category: Structural Components
Subcategory: Structural Wall
Compliance Method: 61G20-3.005(2)(b)
NON HVHZ
Product Manufacturer:
Carolina Carports, Inc.
1B7 Cardinal Ridge Trail
Dobson, NC 27017
Engineer Evaluator:
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID: 1920
Validator:
Brian Jaks P.E. #70159
Contents:
Evaluation Report Pages 1-4
,%t`JI lrrl,rIt,
CE NSA:
. *�99'
�q. STATE OF Cr
A . Cr
orL1) '4,
FL# 6702.1 R5
August 16, 2017
Force Engineering &Testing Inc.
19530 lkamblewood Drive
Humble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1709.2.
Product Description:
AG Wall Panel, 26 Ga. Steel, 36" Wide, through fastened structural wall panel.
Structural Application.
Panel Material/Standards:
Material: 26 Ga. Steel, panel material shall comply with Florida Building Code
2017 Section 1405.2.
Yield Strength: Min. 80.0 ksi
Panel Dimension(s):
Thickness: 0.0185" min. order thickness
Width: 36" maximum coverage
Rib Height: %" major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener:
#12-14 x'/" HWH SD#3 with 5/8" (16mm) diameter sealing washing or approved
equal.
Corrosion Resistance: Per Florida Building Code 2017.
Substrate Description: Minimum 14 Ga. (Grade 50) Steel tube framing or Minimum 18 Ga. (Grade 50)
Steel hat channel purlins/girts. See Table A for steel gauge. Framing must be
designed in accordance w/ Florida Building Code 2017.
Allowable Design Pressures:
Table "A"
Maximum Design Pressure:
-59.9 Psf
-62.5 psf
-83.3 psf
+46.9 psf
+57.3 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
5'-0" O.C.
4'-0" O.C.
4'-0" O.C.
5'-0" O.C.
4'-0" O.C.
Substrate:
Min. 14 Ga.
Steel Framing
Min. 18 Ga. Steel
Framing
Min. 14 Ga. Steel
Framing
Min. 18 Ga.
Steel Framing
Min. 18 Ga.
Steel Framing
•Design Pressure Includes a Safety Factor = 2.0.
1 f111 it t III
C. E, E. Wo I�Ii
0 E Al
STATE OF ;ac
10 *-ALORI�p'.
sw.orlma. i Fy; • . ti ��
i sm ,III 11 0111 %%0
FL# 6702.1 RS
August 16, 2017
rEngineering &Testing Inc.
'19530 Rambke ood Drive
Humble,T'X 77338
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2017, Section 1709.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
ASTM E 1592-05(2012) Test method for structural performance of sheet
metal roof and sidingsystems by uniform static air pressure difference
Reference Data: 1. ASTM E 1592-OS Test
Force Engineering & Testing, Inc. (FBC Organization #TST-5328)
Report No. 183-0063T-16A-E
2. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc.
(FBC Organization # ANE ID: 1920)
Test Standard Equivalency: The ASTM E 1592-05 test standard is equivalent to the ASTM E 1592-05 (2012)
test standard.
Quality Assurance Entity: The manufacturer has established compliance of wall panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Installation: Install per manufacturers recommended details.
Insulation: Manufacturer's approved product (Optional)
Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shear diaphragm values are outside the scope of this report.
4`4444111rrllf��I
"•C E f • jV0
Q?`tCENSF�d�i
STATE OF
�c Le4111
S� • • ..... ff,
ONn44w•
FL# 6702.1 R5 August 16, 2017
Force Engineering & Testing Inc.
19530 Ramblewood Drive
Humble,TX 77338
Design Procedure: Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2017 for wall cladding
wind loads. These component wind loads for wall cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his, drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2017
Chapter 22 for steel, and Chapter 16 for structural loading.
,���tulruttii
E C.
CE NSF<:n ly
No.
47, / r
�" 'd • STATE OF : Ve Z'
A v .
'°�. l'L ORI
m oieas i�' ys •°i ��
FL# 6702.1 R5
August 16, 2017
PANEL FASTEM 2-1-4-1 VATTERN
MIN. 18 " (GRADE 60) STEEL HAT CHANNEL PRAmWO,
OR- MIN. 14 GA. (GWE,50) STEEL TLIBE, FRAM96
(SEE TABLE AFOR SPACINP)
*- 3/4* HA SO#3 W/L Si e (16nm) DLAMkO 5EAJW WASHER
,V6 of Fwfift
-QQA:
August 16, 2017
p
I