Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 5 I � . ' • � W � BCIS Home j Log In User Registration Hot Topics 1 Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map 3 Links i search Florida Product Approval * USER:.Public User L E C002"0 PY Product Approval Menu>Product or Aoolication Search>Application List>Appliwtio E.1 FL# FL20470-R2 Application Type Revision Code Version 2017 RE WED FOR Application Status Approved CODE COMPLIANCE I Comments ST. (�LUCIE COUNTY Archived ❑ 1.1 11 CC i 1117—" // Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,OH 43517 (419) 298-1740 rickw@rwbidgconsultants.com Authorized Signature Vivian Wright rickw@rwbidgconsultants.com Technical Representative Address/Phone/Email l i i Quality Assurance Representative Address/Phone/Email i I Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F.Schmidt, P.E. i the Evaluation Report I Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2021 Validated By Ryan J. King, P.E. Cl Validation Checklist-Hardcopy Received j Certificate of Independence FL20470 R2 COI (a)Certificate of Independence odf i Referenced Standard and Year(of Standard) Standard Year ASTM D1929 1996 ASTM D2843 1999 ASTM D635 2003 ASTM D638 1996 ASTM E1300 2004 ASTM E84 2000 ASTM G26 1995 ASTM G7 1997 TAS 201, 202,203 1994 Equivalence of Product Standards Certified By 4ttps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp... 8/7/2020 Florida Building Code Online Page 2 of 5 Florida Licensed Professional Engineer or Architect FL20470 R2 Equiv Equivalency of Standards.odf Sections from the Code Product Approval Method Method 1 Option D { Date Submitted 04/10/2019 Date Validated 04/17/2019 Date Pending FBC Approval 04/25/2019 Date Approved 06/18/2019 j Date Revised 07/12/2020 Summary of Products Go to Page Page 1/2 i FL# Model,Number or Name Description I 20470.1 a.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.1'odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.1 for Design Pressure Ratings,any FL20470 R2 AE (b) Eval 20470.1.odf additional use limitations, installation Instructions and FL20470 R2 AE (b)TT Plastics.2.odf product particulars. Created by Independent Third Party:Yes 20470.2 [bThe. rma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass mooth-Star Single Door with Sidelite(s)(Inswing/Outswing;XO,OX or OXO configurations) i Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.2.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.2 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.odf additional use limitations, Installation Instructions and FL20470 R2 AE (c) Eval 20470.2.12df product particulars. Created by Independent Third Party:Yes 20470.3 c.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL20470 R2 II (b)Inst 20470.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.3 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.pdf additional use limitations, installation instructions and FL20470 R2 AE (c) Eval 20470.3.odf product particulars. Created by Independent Third Party: Yes 20470.4 rd.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass mooth-Star Single Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (c)Inst 20470.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon.F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes ( Design Pressure: N/A Evaluation Reports Other:See INST 20470.4 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.pdf additional use limitations, installation Instructions and FL20470 R2 AE (c) Eval 20470.4.odf product particulars. Created by Independent Third Party:Yes 20470.5 e.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s)(Inswing/Outswing; XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (c)Inst 20470.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp... 8/7/2020 Florida Building Code Online Page 3 of 5 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.5 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.pdf additional use limitations,installation Instructions and FL20470 R2 AE (c) Eval 20470.5.pdf product particulars. Created by Independent Third Party:Yes 20470.6 f.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (c)Inst 20470.6.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.6 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.odf additional use limitations, installation Instructions and FL20470 R2 AE (c)Eval 20470.6.pdf pro iculars. Created by Independent Third Party:Yes 20470.7 herma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass )(,Smooth-Star Single Door(Inswing/Outswing;X configuration) imits of Use Installation Instructions j A—W HVHZ:Yes FL20470 R2 II (b)Inst 20470.7.3df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.7 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.ydf additional use limitations,Installation Instructions and FL20470 R2 AE (c) Eval 20470.7.pdf product particulars. Created by Independent Third Party:Yes 20470.8 h.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door with Sidelite(s) (Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL20470 R2 II (b)Inst 20470.8.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.8 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.0f additional use limitations,installation instructions and FL20470 R2 AE (c) Eval 20470.8.pdf product particulars. Created by Independent Third Party:Yes 20470.9 1.Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Glazed Composite Edge Fiberglass Smooth-Star Double Door with or without Sidelites(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.9.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.9 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.pdf additional use limitations,installation Instructions and FL20470 R2 AE (c) Eval 20470.9.pdf product particulars. Created by Independent Third Party:Yes 20470.10 j.Therma-Tru Flber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Smooth-Star Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions' Approved for use In HVHZ:Yes FL20470 R2 II (c)Inst 20470.10.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Parry:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.10 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.pdf additional use limitations,Installation Instructions and FL20470 R2 AE (c) Eval 20470.10.pdf product particulars. Created by Independent Third Party:Yes i 20470.11 [kTherm a-Tru Fiber-Classic and Nominal 8'0"Impact"Glazed Composite Edge Fiberglass ooth-Star Single Door with Sidelites) (Inswing/Outswing;XO,OX or j OXO configurations) Limits of Use Installation Instructions ' Approved for use in HVHZ:Yes FL20470 R2 II (c)Inst 20470.11.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other: See INST 20470.11 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.pdf additional use limitations, installation Instructions and FL20470 R2 AE (c) Eva] 20470.11.pdf product particulars. Created by Independent Third Party:Yes 20470.12 I.Therma-Tru Fiber-Classic and Smooth-Star https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp... 8/7/2020 Florida Building Code Online Page 4 of 5 Nominal 8'0"Impact"Glazed Composite Edge Fiberglass Double Door with or without Sidelltes(Inswing/Outswing;XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (c)Inst 20470.12.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.12 for Design Pressure Ratings,any FL20470 R2 AE (b)TT Plastics.2.pdf additional use limitations,installation instructions and FL20470 R2 AE (c) Eval 20470.12.pdf product particulars. Created by Independent Third Party:Yes 20470.13 Fmma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass Star Single Door with"Non-Impact"Sidelite(s) (Inswing/Outswing;XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.13.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.13 for Design Pressure Ratings,any FL20470 R2 AE (b)Eval 20470.13.odf additional use limitations, Installation instructions and FL20470 R2 AE (b)TT Plastics.2.1)df product particulars. (For Fiber-Classic and Smooth-Star Created by Independent Third Party:Yes Sidelites,this product approval requires the use of"]"part numbers for these Sidelites,which have been stained or painted within six months of installation.) 20470.14 [n�Therma-Tru Fiber-Classic and Nominal 6'8"Impact"Opaque Composite Edge Fiberglass ooth-Star Double Door with"Non-Impact"Sidelites(Inswing/Outswing; OXXO configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470 14 pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.14 for Design Pressure Ratings,any FL20470 R2 AE (b) Eva] 20470 14 pdf additional use limitations,installation Instructions and FL20470 R2 AE (b)TT Plastics 2 pdf product particulars. (For Fiber-Classic and Smooth-Star Created by Independent Third Party:Yes Sidelites,this product approval requires the use of"T'part numbers for these Sidelites,which have been stained or painted within six months of installation.) 20470.15 o.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Single Door with"Non-Impact"Sidelite(s) (Inswing/Outswing; XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.15 pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.15 for Design Pressure Ratings,any FL20470 R2 AE (b) Eval 20470.15.pdf additional use limitations, installation instructions and FL20470 R2 AE (b)TT Plastics 2 pdf l product particulars. (For Fiber-Classic and Smooth-Star Created by Independent Third Party:Yes Sidelites,this product approval requires the use of"I"part numbers for these Sidelites,which have been stained or painted within six months of installation.) i 20470.16 p.Therma-Tru Fiber-Classic and Nominal 8'0"Impact"Opaque Composite Edge Fiberglass Smooth-Star Double Door with"Non-Impact"Sidelites(Inswing/Outswing; OXXO configuration) Limits of Use Installation Instructions j Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.16.2df Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.16 for Design Pressure Ratings,any FL20470 R2 AE (b) Eval 20470 16.pdf additional use limitations, installation Instructions and FL20470 R2 AE (b)TT Plastics 2 pdf product particulars. (For Fiber-Classic and Smooth-Star Created by Independent Third Party:Yes Sidelites,this product approval requires the use of"?part numbers for these Sidelites,which have been stained or painted within six months of installation.) 20470.17 q.Therma-Tru Fiber-Classic and Nominal 6'8"Non-Impact"Opaque Composite Edge Smooth-Star Fiberglass Single Door(Inswing/Outswing; X configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.17.odf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp... 8/7/2020 Florida Building Code Online Page 5 of 5 Other:See INST 20470.17 for Design Pressure Ratings,any FL20470 R2 AE (b) Eval 20470.17.Ddf additional use limitations, installation Instructions and FL20470 R2 AE (b)TT Plastics.2.odf product particulars.(For Fiber-Classic and Smooth-Star Created by Independent Third Party:Yes Sidelites,this product approval requires the use of"J"part numbers for these Sidelites,which have been stained or painted within six months of installation.) 20470.18 r.Therma-Tru Fiber-Classic and Nominal 6'8"Non-Impact"Opaque Composite Edge Smooth-Star Fiberglass Single Door with Sldelite(s) (Inswing/Outswing; XO,OX or OXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.18.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes i Design Pressure: N/A Evaluation Reports Other:See INST 20470.18 for Design Pressure Ratings,any FL20470 R2 AE (bl Eva)20470.18.1)df additional use limitations,installation Instructions and FL20470 R2 AE (b)TT Plastics.2.odf product particulars.(For Fiber-Classic and Smooth-Star Created by Independent Third Party: Yes Sidelites,this product approval requires the use of"J"part numbers for these Sidelites,which have been stained or painted within six months of installation.) i 20470.19 EsTherma-Tru Fiber-Classic and Nominal 6'8"Non-Impact"Opaque Composite Edge th-Star Fiberglass Double Door with or without Sidelites (Inswing/Outswing; XX or OXXO configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL20470 R2 II (b)Inst 20470.19.Ddf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.19 for Design Pressure Ratings,any FL20470 R2 AE (b) Eval 20470.19.pdf additional use limitations,installation Instructions and FL20470 R2 AE (b)TT Piastics.2.Ddf product particulars. (For Fiber-Classic and Smooth-Star Created by Independent Third Party:Yes Sidelites,this product approval requires the use of"J"part numbers for these Sidelites,which have been stained or painted within six months of Installation.) j j 20470.20 t.Therma-Tru Fiber-Classic and Nominal 8'0"Non-Impact"Opaque Composite Edge Smooth-Star Fiberglass Single Door(Inswing/Outswing;X configuration) Limits of Use Installation Instructions Approved for use In HVHZ:Yes FL20470 R2 II (b)Inst 20470.20.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 E Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 20470.20 for Design Pressure Ratings,any FL20470 R2 AE (b) Eval 20470.20.pdf additional use limitations, installation Instructions and FL20470 R2 AE (b)TT Plastics.2.pdf product particulars. (For Fiber-Classic and Smooth-Star Created by Independent Third Party:Yes Sidelites,this product approval requires the use of"J"part numbers for these Sidelites,which have been stained or painted within six months of Installation.) Go to Page ! 0 10 Pagel/2 0 0 ..'ck FNext i Contact Us:: 601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 i The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement 1 ' Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.'Pursuant to section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: M9 RiN Rig] eCheil: M j Credit C&d., Safe . 4ttps://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgsJ9a49YAgXJuu9%2fp... 8/7/2020 ``NUluUrrri IHERMAITRU0a OL �: N DOORS Fiber-Classic. om' >••••... & Smooth-Star® • •�.� Ill 11111ii O Am_ \•\m r aN•; N Em z mzn COMPOSITE EDGE F37.7S'hW0.kj GLAZED FIBERGLASS SINGLE DOOR FRAME WIDTH E oz° INSWING/OUTSWINGoc'T "IMPACT' �z GENERAL NOTES � C' 8- 1. This product evaluation drawing has been developed in compliance with the 6th Edition(2017)Florida Building z Z 'e J Aft Cade(FBC)including the"tfigh Velocity Hurricane Zone"(HVHZ). m W� $ 2. Product anchors shallbe as fisted and spaced as shown on details.Anchor embedment to base material shallbe O�E O e tn beyond walldressing or stucco. x C r: o ya 0 3 m 0 When used in the"HVHZ'thts product compiles with Section 1626 of the FBC and does not require an impact ;6 C1 3. Wh W OO resistant covering. / Ix a 4. When used In areas outside of the"HVHZ"requiring wind home debris protection,this product complies with FBC >m a Sections 1609.1.2&R3012.1.2 and does not require an impact resistant covering.This product meets missile level r E "W and includes Wind Zone 4 as defined in ASTM E 1996 and FBC Sections 1609.1.22 8 R301.2.1.2.1. I k 5. For 2x stud framing construction.anchoring of these units shall be the same as that shown for 2x buck masonry o construction. N O z W g O 6. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed � rn engineer or registered architect. Q) e 7. This product meets the water infiltration requirementsfor the"IIVHZ", o a: 8. Outswing configurations using Coastal SO](item#19)8 Composite Sill[item#16)under active doors meet water CL infiltration requirements for"HVHZ".Al other configurations do not meet the water infiltration requirements for the "HVHZ"and shall be installed only in non-habitable areas or at habitable locations protected b an overhang or P Y 9 DESIGN PRESSURE(PSI) DESIGN PRESSURE(PSI) canopy such that the angle between the edge of canopy or overhang to sill is less than 45 degrees. CONFIGURATIONLOCK INSWING OUTSWING < s HARDWARE TABLE OF CONTENTS POSITIVE NEGATIVE POSITIVE NEGATIVE ^ i SHEET! DFSCRiP770N SHEEN X Latch&Deadbolt +55.0 -55.0 +55.0 -55.0 z z 1 Typical Elevat(ons.Design Pressures&General Notes 7 Vertical Cross Sections(Thresholds) onse 08 02/16 ? 2 Door Panel Details B BuckSFrameAnchoring X Multipolnt +55.0 -60.0 +55.0 -55.0 scue N.T.S. 'I"' 3 Elevations 9 Hardware Details m' 4 Horizontal S Verticd Cross Sections(2X Buck) TO Glaring Detals See Sheet 3 for Hardware Specificatlons .BY: JK 5 Horizontal 3 vertical Cross sections 1X Buck) 11 Components cm BY., LFS ; 6 Horizontal 3 Vertical Cross Sections Direct to Masonry 12 Bill of Materials oa'w 1No.: M m FL-20470.7 a t7 s. 1 OF 12 ttt►nuru//� G1 3.6" A6 r'yr 0.7" 4�\ EXTERIOR OS so• �y m `i:fir�`r"� - i�:• :���� O1 INTERIOR L LE COMPOSITE ///// ►t ,� m OCKSTI •t COMPOSITE 17ji nI z HINGE STILE• STET3Rf]NFORCEMENT d'o CAP m o ro CAP (ENGINEERED WOOD) (0.023"THK.) (ENGINEEREDWOOD) ��� o a•:z 1 HORIZONTAL CROSS SECTION N 0 o z.4 T DIA.MAX. 2 0.406° EXTERIOR 3AV N P E m z m°c w 0.7 Gl 0.406° (� g$ 9 c t ,. .r I g 4 m da 0000 000 3 DETAILA•A STEEL REINFORCEMENT 1'` INTERIOR o PANEL REINFORCEMENT 28.86%OPEN COMPOSITE LOCK STILE COMPOSITE y (0.023"Thick Steel) HINGE STILE STEEL REINFORCEMENT (ENGINEERED WOOD) CAP AREA MAX. CAP a (ENGINEERED WOOD) (0.023"THK.) Q HORIZONTAL CROSS SECTION o 0 'R#8 X 2.5'PFH WS(TYP.@ EACH DOOR CORNER) m ;il7ci:„%'t;`s•:+'' TOP RAIL "'A'' (COMPOSRE/ s5sc ti.r,•;,i::•. �m � o� 36.0°MAX.DOOR 35.813"MAX.DOOR 35.813"MAX.DOOR ENGINEERED WOOD) ., I-; o 0 PANEL WIDTH PANEL WIDTH PANEL WIDTH - 3 I* 2 FOAM CORE :'r!• '' �m (POLYURETHANE- ' 1.9 PCF MIN.) 1 2 2 - E n / 0 2 / o 0 INTERIOR EXTERIOR INTERIOR EXTERIOR w o C9 pn C9� � w to G1 I G1 ® j0 Q 1 � � 1 m � s x g x g x � T 5' STEEL REINFORCEMENT (0.023°THK.) / / / :;•:.: FIBERGLASS SKIN j'`..j:: DIE 08 02 16 = (0.073"THK) swa N.T.S. 01 z�¢ o 2 I I BOTTOM RAIL I� owc.ert: JK m (COMP.) I�1.71" cHw er. LFS 3 c I I n I DRAWING ND.: � n DOOR PANEL * * 41 DOOR PANEL * * 42 DOOR PANEL * 2 VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION FL_20470.7 N 6 BOOK HybrldDoor Ul Door sHe[T 2 of 12- a I R:\Oler MTherma Tru PBtMANENT\N-Florida Product Appmvels\FL-20470 HVHZ TT-Composite\C-Drawings\FL-20470(2017)\F1-2D470.7-9.dwg,3.1 I aN � I C N� i O�N a en I �\ rr� e. a A I A W I I I � � D 0 m 15 n t0 0 CL boo o s � 40 I n G m S A �EM m M T � C O Z C Z 10 gO O_ O O_• W �u :•: ^ m?i_ C A T: C N N I C I I SCNIyj��•,, oem 09 No*434 4 PRODUCT: Dmume-Prrpand B3.. i 849E OF ' IW N FIBERGLASS DOOR P.E.d No F. Schmidt 4340D o z o III m1 t�p� V L y tJ PART OR ASSEMBLY: BUILDING CONSULTANTS, rJLJ11, Io cn 1 7 14 17 UPDATE TO M ED. 2017 FBC JK XWP.O. Box 230.Valrieo. FL 33595 N v o1 NO DATE BY ELEVATIONS Phone No.: 813.659.9197 REVIS ONS FBPE CA No. 9613 0 201 8 R.W.BUILDING CoNBULTANTa INa. '` wlmentslThemla Tru PMMANENTW-Florida Product AppmvalsV1.2D470 HVHZ Tr-Composlte%C-DraWgslFL-20470(2017)1FL-20470.7-9.dwg,4.1 I I I •n• m W , I A N � r,• I i N (BA O N i N o. n o § ? m O N IC) 0 p0 W A - r O 70 A Ja_+ 0 N M Oo a m n • I O N < `N O Z 14n I •'a i a• I A h I-114"MIN. EM8.(TYP.) AW N �Iq v sn 0.= p n o O i£ V 0mD r 0 ;. Y1. N 3 � t f I _ t •— m 3 tttunrrrri '7.z'117► * = o PRODUCT: DooYmenb PMParod 9y. : • eD►TrsoP � THERMA—TRU Lyndon F. Schmidt ��-- •Mor •••d`` 1� _ FIBERGLASS DOOR P.E. No. 43409 '?,Sip/NA1. �`� c y N GIB BUILDING CONSULTANTS, I��Tltt t` 4. PART OR ASSEMBLY: JL p x(/1 1 7 14 17 UPDATE TO BTH ED. 2017 FBC JK W P.O. Box 230. Valrico, FL 33598 NO DATE BY CROSS SECTAIONS (2X�BUCK) Phone No.: 813.659.9197 R SONS FBPE CA No. 9813 432C1fi R.W.BUILDING C....LTA-9 INC. PukClerdsMerma Tm PFRMANEMVI-Horlda PmduQ Appro lsVi.-20470 HVHZ lT-Composte\C-Drawings\FL-20470(2017)VL-20470.7-9.dwg,5.1 m d a` I n. a N O=S ' W 7 H 07 y p. n CD o _ ' p 3 ie . m O Z N I22 0 70 O m a C2 T 22 O N O A .v• ° J 0o c �X~ 3yn y • 3 Z Im .• • I n r o A A A I N W N Orn= CP. c 2� n [c coo a N a.a m ? No.43409 ¢ $ PRODUCT: Dxum.ntm Pmpored By: STATE OF THERMA_•RU Lyndon F. Schmidt � ••.. OR�Ow.•••6` IN N FIBERGLASS DOOR P.E. No. 43409 � ............ o V -1 N PART OR ASSEMBLY: GD BUILDING CONSULTANTS, O 7C to _, 1 7 14 17 UPDATE TO 6TH ED. 2017 FBC JB JL P.O. Box 230, VDIAeo, FL 33598 IN v rn NO DATE 'HORIZONTAL & VERTICAL Phone No.: 813sIrico. 7 REVISIONS CROSS SECTIONS (IX BUCK) FBPE CA. No. 9813 0 zo I a R.W.BUILDING CDNSULTANTG INC. ��uuuTai��� _ o*t E 1S E 15 �Ni z Q:?gyp-a! MAX. MAX. `- ��i �'••.. . ''�.�� Lan zom6 C 1 C 1 U N p Z *Z4; 40 41 42 V(� N 9° a C 40 41 42 LZ . `a 9! € `0 o= �q EXTERIOR NTERIOR EXTEPJOR INTERIOR �a � Z � 1 VERTICAL CROSS SECTION 4 VERTICAL CROSS SECTION c Fe 6 Shown Direct to MasorxY 6 Shown Direct to Masoruy Outsvingonyw/4-9/16'jamb Outswing only w/6-9/16'jamb rC3 w� gg y g �IZZ 00 W a a h C C f 1 C °U8 U E €� INTERIOR � c N q i 40 41 42 o^' :op e a a' :°p n a a• = INTERIOR F L N 40 41 42 N E M h M � 'o d M r o e a 1-1/4"MIN. :D z EMB PP.) A EXTERIOR E E 0 1-1/4"MIN. 1-1/4°MIN. EXTERIOR 1-1 "MIN. ° EMB.PP.) EMB.(TYP.) M Eo1B.)TYP.) w�08 02 16 z N.T.S. 2 HORIZONTAL CROSS SECTION 3 HORIZONTAL CROSS SECTION 5 HORIZONTAL CROSS SECTION 6 HORIZONTAL CROSS SECTION •IM JK m 6 Shown Direct to Masonry 6 Shown Direct to Mason 6 Shown Direct to Masonry 6 Direct twM6a9/1 bj amb CM BY. LFS Outswi only w/4 9l16"amb y Outswing only w/6-9/16'jamb 9 NY 1 auwwc rm: n9 Y 1 OutrMng only w/4-9/16 jamb �_Y0470 i0 0 sxtft s OF 12 0 a \\1111111/III/ Notes: 1.S➢I Item Ws 17.18,32,34,35,36,37.38&37 are attached to jambs w/(3)#8 X 2-1/T pth screws at each end. Sill Item Ws 16&33 are attached to iambs w/(2)#8 X 2-1/T pfh screws at each end. Q-A. Sill Item#15Is attached to jambs utilizing(2)#10 X T pph SMS at each end. _• * , Ica z 0�q a m i9 INTERIOR EXTERIOR INTERIOR EXTERIOR III 1 1111\i\ i c m o (n M 0 C4 �o a V Xz Em zmoa 40 41 42 g 40 41 42 9 `INe y< 9 a o a a LLZ maa�i Z 32 38 39 33 34 35 36 37a SEE NOTE I E SEE NOTE I E tti i rs;c; .�,,r`r i r r C �O D ^ �p O= .. n .: °. a ..e a n °. ° U• j5 {=y N a] 1 VERTICAL CROSS SECTION o e' ] Inswing Sill 2 VERTICAL CROSS SECTION a g ] Inswing S➢I a �m u U ,9 EXTERIOR INTERIOR EXTERIOR INTERIOR N N 16 17 18 19 40 41 42 g 40 41 42 7 10 E 15 2 E e SEE NOTE 1 E SEE NOTE 1 0 i o DST 08102116 1 z 3 VERTICAL CROSS SECTION e ] Outswing S➢I(Coastal Sill Shown) 4 VERTICAL CROSS SECTION D MM� N.T.S.D"` JK m 7 Pub➢c Access Sill DRA er LFS 3 'S DRAW9IG NO.: M €E m f 1-20470.7 a mm 7 of 12 6 R:KOents\Thenna Tm PERMANENT\A-Rarlda Product Approvals\FL-20470 HVHZTT-Composite\C-Drawings\FL-20470(2017)VR.-2D470.7-9.dxg,0.1 �0 i n 00 z � A z � 16"AMX. � 4"(TYP.) I+— O.C.(TYP.) I i I 0 q• m 7c o rn y 3 z 3 r— z —� _ � 0 O y 7C N O z I O.C.IT\'P.) 22 I w , O I y� . o I �m I x H ```tUtlilllf/f!//i sCHMip •No.43409•r 5p2 $ PRODUCT: Documents Prepared 8'MOF r THERMA—TRU Lyndon F. Schmidt I FIBERGLASS DOOR P.E. No. 43409 // s► ��� I� o z o .�, V r— r -1 N PART OR ASSEMBLY: GD�/�/BUILDING CONSULTANTS,�N�11t IO � to 1 7 14 17 UPDATE TO 6'TH ED. 2017 FBC JK BUCK & FRAME ANCHORING J�,lrfr P.O. Box 230. Valrico, FL 33595 N v rn NO DATE BY Phone No.: 813.659.9197 REVISIONS FBPE C.A. No. 9813 2O7 B R.W.BUILDING DaNBULTANTB INC. I I `���ur L n rrrq `J�•40 m m N Z * Fro T!m 2X BUCK Fn O O '�'/i ••�% ~i o m m 1X BUCK G SEE HINGE �ii�rr 1111T��� N>M W DIRECTTO z d�d DETAIL tTYP.) "�••Z MASONRY M 26 \ 8 c° Z m z v U 9 d a ° L 6 NI 7 t 2XBUCK 25 a LL m D n 1XBUCK G h D Pn E oz O SEETONGUE a cii [XRECTTO M '+ 0 o STRIKE DETAIL = 2XBUCK L ' �d MASONRY �, o o ITYP.) Y ° ° LATCH&DEADBOLTDETAIL � � C,O N= � 1XBUCK G Kwfkset " m s DIRECTTO M � •® _ MASONRY 31 0 8LU y o ry SEE LATCH TONGUE STRIKE DETAIL i m 2XBUCK L &DDEWL EADBOLT SEE LATCH uponLock w 8 o 1XBUCK 6 DEADBOLT m � G 8 DETAIL j t- "dw 0 DIRECTTO M o o MASONRY Security Sub 0 a Strike Plate E Y 28 2XBUCK ' 8 LU 1XBUCK G E $ STRIKE JAMB HINGEJAMB STRIKEJAMB DIRECT TO (y) ^ k 2XBUCK Latch and Deadbolt Multipoint lock MASONRY 30 N 'n W O 1XBUCK G 27 D DIRECT TOM MASONRY LATCH uDEEADDBOLTDETAIL LATCH&DEADBOLT DETAIL 29 L 2X BUCK a D c G 1XBUCK _ Schlage 8B ^ M DIRECTTO g MASONRY '¢o LATCH&DEADBOLT STRIKE DETAILS M DMASONRY 24 23 M ULTIPOIIVT LOCK STRIKE DETAILS Z U DATE 08 02116 i L sate N.T.S. m' a DEADBOLT STRIKE DETAILS HINGE DETAIL um BY.. JK (Security Deadbolt Strike Plate) p1L BY. LF 3 DRAM No:' R FL-20470.7 c SHM 9 oF 12 N oC ``1111111111/// EXTERIOR ``• �Z•� � �t:a-•n n CELLULAR _ * Z�n •7 z' l0= n GLAZING TAPE 1/2 GLASS BITE a, �` �'m 1"THK.GLASS i:, ��/i�•••'•........ 'Al =m n 1/8"TEMPERED GLASS //i * >>°'a t/7AIRSPACE �1 llll 11111` 8.a°pz 513T ANNEALED GLASS �J \ N �, E i m z v WROUGHT IRON INSERT y r g u ] °c n. DOW 995 _�0.090'PVB INTERLAYER IMERNAL GRID(GBG) ' m m a a fL OR (SAFLEX OR KURARAY BUTACITE) g 4 SIKA 552 E `o z° Iff ANNEALED GLASS E ui #IOXI-1/2"PPHSMS o a 3A SWIGGLE GLAZING SPACER 9 INTERIOR GLAZING DETAIL 4 �o r.+ Gl Aluminum Impact Ute Frame Door Panels 35ldeGteS DECORATIVEINSERT L5C3 z PRIVACY INSERT K mq 20.W D.L.O. o '1 WIDTH r 1"LAMINATED INSULATED IMPACT GLASS INSERT OPTIONS al a 3 9 1m U O_ E pE k o m 1.53" 8 V) J #10 X I-1/2"PPH SMS i (TYP.) L� J e' n m 4„ ^Z c°i ALUMINUM FRAME 3A (TYP.) ash 08 02 16 i Aiumtram Impact LBe Rame DoorPaneis, d.Ites soma N.T.S. ALUMINUM UTE FRAME Dwc.m: JK m 2 OWL er. LFS 3 DPAWM ND.: u FL-20470.7 a SHEET 10 -12 s a z ``�1111I1lr!!// \\\ . � O°• N 4.56" =Z�o�' Cb 7.59" 75" r Z P'y Z L F�2.3e lrr�1 a nmi 32 INSWING THRESHOLD 37 INSWING 7HRFSHOID O� a c Inur ng Back Compasrfe Adjustable Sg 7-1/2 Insvmg Basic Foced 7-1/2 SM 1 WOOD JAMB \\ `y ! E m m c w V� y r 9 a:0 IL 4.56' 4.56" =r. 5.83' Cz a o u? kt^Y v y1 < sha „Y OUTSWING THRESHOLD a INSWING THRESHOLD INSWING THRESHOLD 16 Composite Sill z o S 33 Insw ng Bas c Fixed S 0 38 lr sti g Compos to Adjustable S81 MAX.ss FiF �ICn IwherewaterhRliu MnkrecluYedl m a 5.7S' W o 5.77" 4.56° �� U IS o INSWING 7HRESHOLD .^ :. --. •-:.o m 34 Inswing Modero1.Cimate Sill 13/8• INSWING THRESHOLD OUISWING THRESHOLD 39 Inur ng Basic Composite Adjustable Sill 17 Composite/Aluminum Sil E ._ n k 5.75' 5.75" a N Mr 0 vi in •:S 1z;„:_v?';i.'i'`' Sal in fo OUTSWING iHRESHOID )" INSWINGTHRFSHOLD 18 Composite/Alun*wmSB Qo 35 truwing Moderate CBmateSil (memtal Break) ti a PUBNC ACCESS THRESHOLD 4S6° F i � 5.75' 15 2.36' �Fa z ros L -tr.; ;. ?:^;itifsi;w. _;s,_ ,"-:: wh 08102116 z • I I N.T.S. 36 INSWING THRESHOLD ��--1.79" I F--1.92" I oWD•m`• JK m Fes--2 06" cxK.BY LFS 3 Irm Basic Fixed 5314'Sli Ga ? La rc ng o o COASTAL OUISWING THRESHOLD awuw+a Nos m 0 8 SWEEP 9 SWEEP 10 SWEEP o 19 Wood/AluminumSil FL-20470.7 0 W sir 11 OF 12 N O 1\11111111 p�� BILL OF MATERIALS BILL OF MATERIALS REM 0 DESCRIPRON MATERIAL REM 4 DESCRIPTION MATERIAL r * �• Q_ n A 1 X BUCK(SG>=0.42) WOOD 25 #8 x 2-1/7'PFH WOOD SCREW STEEL B 2X BUCK(SG>=0.42) WOOD 26 #8 x 5/8"PFH WOOD SCREW STEEL �'•�' C 1/4"MAX.SHIM SPACE - 27 LATCH STRIKE PLATE STEEL �'�i�Y''•• .....•• '�i````� 1 A R 2 D ' 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE(STANDARD) STEEL i����q 1k 1Pf 11 E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE 28A DEADBOLT SUB STRIKE PLATE STEEL =Ow o 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 28B DEADBOLT STRIKE PLATE(SECURITY) STEEL -I: N z G 3/16"X 3-1/4"ff W CONCRETE SCREW STEEL 29 4"X 4"HINGE STEEL N E m ?m°z J 1/4"X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 30 LATCH&DEADBOLT STRIKE PLATE(TONGUE SYSTEM) ALUM/COMP H 56 r m L #10 X 2-1/7'PFH WOOD SCREW(1.15'MIN.EMBEDMENT) STEEL 31 MULTIPOINiSTRIKE PLATE(TONGUE SYSTEM) ALUM/COMP s LL . `a�` M 3/16"X 2-1/4"ITW CONCRETE SCREW STEEL 32 INSWING THRESHOLD ALUM/COMP Z N 3/16"X 2-3/4"ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP �a 1 JAMB(FINGER JOINT PINE) WOOD 34 INSWING THRESHOLD ALUM/COMP 6 WEATHERSTRIP(MEDIUM REACH) FOAM 35 INSWING THRESHOLD ALUM/COMP 3 7 WEATHERSTRIP(LONG REACH) FOAM 36 INSWING THRESHOLD ALUM/COMP 8 SWEEP VINYL 37 INSWING THRESHOLD ALUM/COMP Z30 s a 9 SWEEP(USE W/MODERATE CLIMATE THRESHOLD) VINYL 38 INSWING THRESHOLD ALUM/COMP Q a 10 SWEEP(USE W/PUBLIC ACCESS THRESHOLD) VINYL 39 INSWING THRESHOLD ALUM/COMP 15 PUBLIC ACCESS THRESHOLD ALUM 40 DOOR PANEL(BOOK) 16. OUTSWING THRESHOLD ALUM/COMP 41 DOOR PANEL(HYBRID) - 6 W m ' 17 OUTSWING THRESHOLD ALUM/COMP 42 DOOR PANEL(Ui) - 18 OUTSWING THRESHOLD ALUM/COMP a 19 COASTAL OUTSWING THRESHOLD ALUM/WOOD 22 #8 x 3/4"PFH WOOD SCREW STEEL 'm 23 #10 x 3/4"PFH WOOD SCREW STEEL a 24 #10 x 1"PFH WOOD SCREW STEEL Ecn _ N kCONCRETE ANCHOR NOTES: z 1.Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarjoints. 8 2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to o maintain the min.edge distance to mortarjoinls,additional concrete anchors may be required to ensure the MAX.ON CENTER"dimension are not exceeded. 3.Concrete anchor table: a J � z RNCHOR ANCHOR MIN -MAy CLEARANCE .MI^I CLEARANCE ,. m 7O MASONRY TO ADJACENT "w �C 41'PE SIZE E'Mflt DMENI .r < ............................. ANCHOR;:,..... ^o ITW TAPCON® 1/4" 1.1/4" 2" 4"ELCO ^p o Z a ULTRACON 1/'r 1.1/4" 1" 4" rHm 08102116 = SCALE N.T.S. TA TW a 3/16" 1-1/4 AS SHOWN 1.1/2' DW&BY; WOOD SCREW INSTALLATION NOTES: aK up LFS 1.Maintain a minimum 5/8"edge distance,I"end distance,&1"o.c.spacing of ° No wood screws to prevent the splitting of wood. FL-20470.7 n Seer 12 ov T2 D 'a