Loading...
HomeMy WebLinkAboutAPPROVED, Metal Sales Underlayment Fl11602-R10\j q W� SCIS Home Log In User Registration Hot Topics Submit Surcharge Stars &Facts Publications Contact Us BCIS Site Map Links Search bp1 Product Approval l USEW Public User dr, k , A Product A2qroygI Menu > Prgsi= Or Apalication Search >,6pp > Application Detail FL # FL11602-RI0 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Roofing and Asphalt, LI-C Address/Phone/Email one Owens Corning Parkway Toledo, OH 43645 (740) 321-6345 Gring.Keeler@owenscorning.com Authorized Signature Keeler Greg Greg,Keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeter@owensr-orning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nierninen Evaluation Report Florida License PE-59166 Quality Assurance Entity 1ntertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 12131/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of independence 171-11-U2 &10.,COI 20j9--PA-=--WUIIIWEN---P-dJ Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D226 (physicals) 2009 ASTM D4798 2011 FRSA/TPI April 2012 2012 TAS 117(B) 1995 UL1897 2012 Equivalence of Product Standards Certified By sections from the Code Product Approval Method Method I Option D Date Submitted 10/17/2019 Date Validated 10/1712019 Date Pending FEC Approval 10/20/2019 Date Approved 12/10/2019 Of r-L # Model, Number or 14ame Description 111602.1 Titanium Roof Underlayments --�Synthetic sheet -type roof underlayments Limits of Use Approved for use in HVHZ. No Approved for use outside HVHZ., Yes Impact Resistant: N/A Design Pressure. +N/A/-45 Other: 1.) The design pressure noted herein pertains to use of a specific underlayment system beneath foam -on tile sytsems. Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5 and 6 for other Limits of Use. Installation Instructions FL11602 010 tj 2019 10 _FINAL ER FLJ,16027Aj%P-d Verified By, Robert Nierninen PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL11602 B10-A_E2gI Created by Independent Third Party: Yes Contact �. 2601 Glair Stone Road, Tallahassee FL R399 Phone: 850-487-1824 , _a 02. The State of Florida is an AAJEE0 employen riaht 2 0 07 -2 0 13 State of F) 0 rt 9a. :: ECLagi-julmma-e-n-t : i Accessibility b Refund gWMMgrtt Under Florida law, email addresses are public records. if you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. It you have any questions, please contact 850.467,1395. *Pursuant to Section 455,275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are pubic record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F-S., please click hLr_q_. Product Approval Accepts'. = = Rim =1 = Credit Card Safe NEMO I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION REPORT Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11,08-R11 One Owens Corning Parkway FL11.602-RSO Toledo, OH 43659 Date of Issuance: 11/03/2008 (740) 321-6345 Revision 11:10/17/2019 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titaniui" "m Roof Underlayments LASELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "MEMO{etc. Evaluated" may be displayed in. advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through S. Prepared by. ,�,u„�,��{;,•,,,,, A.K Sr�S,.g l/f Robert l.nii.lVieminen, P.E. °i`` -;. The facsimile seal appearing was authorized by P,nbert �`` Florida Registration No. $916&, Florida RCA ANEt983�,,,, ; Nieminen, P.E. on 10/17/2019. This does notserve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1, NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E, are, in any way, the designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018 NEMO ETC, LLC NEMO etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category. Underiayment Compliance Statement: Titanium`" Roof Underlayments, as produced by Owens Coming Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 6ti Edition (2017) Florida Building Code through testing in accordance with applicable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro I pertStandard Year 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1,1, 1507.2.9.2 Physical Properties ASTM 01970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS 110 Pull -through resistance TAS 117(B) 1995 Examination Reference Date Enti ERD (TST6049) Physical Properties 115010.04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05A0 05/14/2010 ERD (TST6049) Physical Properties 135520,06.11 06/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TST6049) Wind Uplift 135520.08,11-1 08/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS (TST1509) ASTM D226 3130639COQ 002A 08/21/2007 ITS (TST1509) Physical Properties 3126617COQ-005 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 ERD (TST6049) Physical Properties (NH) 4j-OC-19-SSUDL-01.A 06/14/2019 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear Strength OCF-332-02-02 10/0312017 PRI (TST5878) ASTM 01970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-343-02-01 11/09/2017 PRI(TSTS878) ASTM D4798 OCF-341-02-01 11/27/2017 PRI (TST5878) TAS 117(8); Pull -through OCF-422-02-02 04/03/2018 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-425-02-01 08/13/2018 PRI (TST5878) ASTM D226 / ASTM 04798 OCF-331-02-01 R1 05/0712019 PRI (TST5878) ASTM D226 / ASTM D4798 OCF-332-02-01 R1 05/07/2019 PRI (TST5878) ASTM D226 / ASTM D4798 OCF-334-02-01 R1 05/07/2019 PRI (TST5878) UL1897 1378TO02 07/10/2019 PRI (TST5878) Tensile adhesion OCF-507-02-01 08/13/2019 ITS (QUA1673) Quality Control ITS Listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 MEMO ETC, LLC Evaluation Report 111980.11.08-R11 Cert±ocate o}Autho izaNdrn,#32455 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-1110 Titanium Roof Underlayments Revision 11:10/1712019 Page 2 of 8 ONEMOJetc. Product specif'rcatlon Plants Description 4.1 TitaniumT' PSU-30 ASTM D1970 Dubai, UAE & unreinforced polymer modified bitumen material adhered and FRSA/TRI Brentwood, NH to the underside of a polymer -coated, synthetic woven April 2012 sheet. The underside is backed with a release film. Unit weight 24 lbs/square 4.2 TltaniumT1 UDL 25 FBC 1507.1.1 Qingdao, China synthetic sheet -type underlayment comprised of a woven & R905.1.1 core coated on one side with a polymer coating. Unit (Exception) weight 2.5 ibs./square 4.3 TitaniumTM UDL-30 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven & R905.1.1 Canada & core coated on both sides with a polymer coating. Unit (Exception) Qingdao, China weight 4.01bs./square 4.4 Titanium" UDL-50 FBC 1507.1.1 Mission, BC, synthetic sheet -type underlayment comprised of a woven & R905.1.1 Canada & core coated on both sides with a polymer coating. Unit (Exception) Qingdao, China weight 4.7 ibs./square 5.1 This is a building code evaluation. Neither MEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5,2 This Evaluation Report is not for use in FBC HVHZ jurisdictions, 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium'"` Roof Underlayments may be used with any prepared roof cover where the product Is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 n1i1,,to RnnFCc%rerc• TABLE 1: ROOF COVER OPTIONS Asphalt Wood Shakes underlayment Shingles Nail -On Tile foam -On Tile 'Metal & Shingles Slate Titanium P5U-30 Yes Yes Yes (see 5.5.1) Yes Yes Yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Yes Yes Yes Titanium UDL-30 Yes (ease Sheet in 2-ply {aaseSheet ina-p1v system) system) Titanium UDL-50 Yes No No Yes Yes Yes Evaluation Report 111980.11.08-R11 NEiJiC) ETC, LLG Revision 11: Certif+eate ofAuthorizution #32455 a EDITION (2017) FBC NGiN-FfVHZ EVtkL+�ATiGTN 10/172-9 Titanium Roof UnderlaY-ents Page 3 0of81 011YIEM01 etc- 6.3.3 Slopes of 4-12 or g End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical) laps shall be offset from course to course not less than 6 feet. Minimum attachment shall be in accordance with FBC Table 1507.1,1 or R905.1.1. When batten systems are tnbe installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2.12 to less than 4:12: End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 25-inches. End (vertical) laps shall beoffset from course tncourse not less than 6feet. Begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 25-inch side (horizontal) laps, resulting in odouble-laver application. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c. When batten systems are tobeinstalled atop the undedayment the undedaymentneed only bepreliminarily attached pending attachment wfthe battens. 6.4 6.4.1 Non -Tile Installations., Shall be installed in compliance with the codified requirements forASTK8 D1970 underaymer¢ in FBC Table 1507,1.1 for the type of prepared roof covering to be installed, and Owens Corning published requirements. Titanium",' PSU-30 shall be back -nailed in accordance with Owens Corning published installation requirements. 6'4'2 Nail -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane under|oyment set forth in F8S4/TK(April 2O12(04'1Z),and Owens Corning published requirements. 'Utan(um"°9SU-3Oshall baback-nailed max. 6" oz. with 12 ga. galvanized annular rink shank nails through 32 Qa~ 1-5/8-inch diameter tin caps in accordance with Owens Corning published installation requirements. Refer tnSection S.8for tile staging limitations. 64.3 Foam -On Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane undedaymentset forth in FRSA/TR|April 2O1Z(}4-12)'and Owens Corning published requirements. Titanium" PSU-30 shall be back -nailed ",°"' s^ o.c. with 12 gm. galvanized annular rink shank nails through 32 92_ 1'5/8'/ndh dian`ete, tin ceps in accordance with Owens Corning published installation requirements. Refer toTable lAfor allowable tile adhesives. Refer toSection 5.§.1for wind uplift limitations. Refer tnSection 5.8for tile staging limitations. 6.5 8.5.1 The Titanium 2-Ply System consists of a base layer of /mau/om uuL-30 pup'swname primed o, snccr inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6.5,2 Applications - Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30inaccordance with Section 6.4. NEMOETC, uc Evaluation Reportu���08-RII Certificate ofAutharizatmm324SS 9- EDITION (2017) F13CmON-HvHZ EVALUATION F1.11602-RIG Titanium Roof uvdenaymente Revision 11.10/17/201 Page 7mn 01011EM01 etc. 6.5.3 Nail -On Tile Applications: For nail -on the installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRl April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. Refer to Section 5.8 for the staging limitations. 6.5.4 Foam -On Tile Applications: For foam -on tile installations, install Titanium UDL-30 {top surface primed or sheet inverted) in accordance with Section 5.6.1 herein. Then apply Titanium PSU-30 in accordance with Section 6A Refer to Table 1A for allowable the adhesives. Refer to Section 5.6.1 for wind uplift limitations. Refer to Section 5.8 for the staging limitations. 7_ BUILDING PERmfT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer to Section 4 herein for product & production locations having met codified physical properties specifications. Intertek Testing Services NA Inc. — QUA1673; (604) 520-3321 - END OF EVALUATION REPORT - NEMO ETC, tLc Evaluation Report 111980.11.08-RII Certificate ofAutharization #32455 67" EDITION (2017) FSC NON-)iVHZ EVALUATION FL116A2_R10 Titanium Roof Undertayments Revision 11: 10117/2019 Page a of 8