HomeMy WebLinkAboutConstruction Plans` 'd Inverter Type: Pika PV Panel: (36) Silfab 3IOW Racking: Iron Ridge Total Wattage: 11,160W Roof Type: Metal Wind Load: 7 to 27 Deg Fastener Type: Use Roof Tech Mini's S-1 Cover Sheet / Site Plan S-2 Detail E-1 One - Line S-IA Mounting Plan -(2) Pika X7602 Inverter located near utility meter -PV Link S2501 Optimizers are located on roof within 10' of each array -First responder access maintained and j4miatdiacent roof. \\v" 'r�ru 'ff6rparray to connection is 60 feet. * ; N g gW Godwin Engineering and * = Design, LLC ! 8378 Foxtail Loop 0�` c T or ��Zr Pensacola, FL 32526 ORIDP:' Godwin, PE �NA� D. Chad God ��/�/llllllll�l�(,f Chad@godwineng.com DEC 0 3 2019 8T. Lucie -Pika X Inverter FILE Copy ST.LUCIE COUNTY PLAN REVIEW BLDC, DATE L , DATE,/ PLUMB_ _^ DATE MECIt DATE: Utt 11L.' lv1VLVL System meets the requirements ofNFPA 12015 Edition, Chapter 11.12 70' GER R-1 # Modules (36) Pitch: 20' Azimuth: 180' -COGEN Disconnect Located adjacent to Utility meter -Pika X7602 Inverter FRONT OF HOUSE Legend ® Chimney Meets All Editions of Florida Fire Prevention Code 6th Edition ® First responder access fR Satellite ❑� Utility Meter o Vent Pipe Represents all Fire Clearance 1st Responder Access EP PV Disconnect F7_1 Pika Inverter including Alternative methods minimum of 36" unobstructed as per Section R324 of the 2015 IRC 2017 FL Residential Code & FBC ,6th Edition (2015 International Residential Code - 2nd Printing modified by the FL Building Standards and Codes 2017 Uniform Code Supplement), 2015 International Energy Conservation Code, County of St. Lucie Code, 2014 National Electric Code. Layout Subject to Change Based on Site Conditions Customer Info: Vasile Ciuperger 15370 Skyking Dr. Port St. Lucie, FL 34987 561-758-9688 4628 Eagle Falls Place, Tampa, FL 33619 1-888-801-2030 Date: 11.13.19 N s Cam ass for Aei Drawn by: NM Checked by: Rev #• 00 Rev Date: Page: S-1 3/e-16 X 3/4 HEX HEAD BOLT 3/8-16 FL^NCE HUT Ironridge XR-10 Ems_ General Notes: - L Feet are secured to roof tech mini. @ 48" O.C. using (2) M5 x 60mm stainless steel Lag bolts into rafters. - Subject roof has One layer. - All penetrations are sealed. Roof Section Pitch I Roof Rafter and Spacing Overhang Notes: R1 4/12 �Steell-Beams@20'0.C. 1011 Horizontal Metal Perlins Customer Info: Designed g per as ASCE7-10 p Inverter Type: Pika PV Panel: (36) Silfab 31OW Vasile Ciuperger Racking: Iron Ridge 15370 Skyking Dr. Modules mounted flush to roof Total Wattage: Roof Type: 11,160W Metal Port St. Lucie, FL no higher than 6 above surface. Wind Load: Fastener Type: 7 to 27 Deg Use Roof TechMini's 34987 561-758-9688 solm Module 3-5/811 �\\\\001E 1 C����/i/i Godwin Engineering an `�� O; LICE Ns 0 Design, LLC;' No F . 8378 Foxtail Loop so i Pensacola, FL 32526 =0 D. Chad Godwin, PE 0 �� q F ? Chad@godwineng.com �s'i' °RIDA •.`�Y�,���� o��i l I IE111G �l�l„G�/f 4628 Eagle Falls Place, Tampa, FL 33619 1-888-801-2030 Date: 11.13.19 11 Drawn by: NM Checked bv: Rev Date: S-2 fl©lam' 1-•-­1 u L_ PV Link Optimizer Per string Each Inverter Output Ckt To Overcurrent Protection Device AC Max Output Current 32 AC Max Output Current " 1.25% 40 Overcurrent Protection A 40 No. of Current Carrying Cond <4 Conductor Gauge AWG 8 �•� 5+ 1 6+ • • • 5 6 Load Side Connection Busbar Rating 200 Main Breaker Size 200 Bus Rating .1.2-Main Break Size 40 Max Allowable Load Side 40 Load Size Breaker Size 40 In Case of Emergency Call Sunbility at 888-801-2030 J-Box Typ 3-Box — TYP uvmnn •:. un.rx — mm;rrarr y,. — fYSASrf�C 70' Trench at least 18" deep Voltage Drop Calculations 2(12.9 ohm-cm/ft)•70ft•26A =4.5V 10383cm 4.5V =17% #10✓ 259.6V M -Box TyP ' i.��rr°`.�E.nyr, •wa®,:n Harbor Smart 3 Battery Equipment list PV: (3 6) SLA-M 310BLK (6) Pika Power Optimizers Inverter 1: (1) Pika Energy Model X7602 (4) strings of (6) Harbor Smart 4 Battery Inverter 2: (1) Pika Energy Model X7602 (2) strings of (6) Harbor Smart 3 Battery AC Disconnect: 60A Rated Disconnect All wiring to meet the 2014 NEC 2015 Energy Code WITH 'HOTOVOLTAIC SYSTEM DC DISCONNECT MAX POINT CURRENT: 18.8 A MAX POWER POINT VOLTAGE: 198.3 VOC AIAX SYSTEM VOLTAGE: 259.6 DC MAX CIRCUIT CURRENT: 233A WARNING ELECTRIC SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED DO NOT TOUCH TERMINALS TERMINALS ON BOTHTHE LINE AND LOAD SIDES MAY BEENERGIZED IN THE OPEN POSITION w 32 Critical Loads Panel 125A #6 LLL2 &neutral r"t,,�v��, UNGROUNDED AND MAY BE ENERGIZED _- #10 Ground WARNING In Min 3/4' Conduit DUAL POWER SUPPLY Pika Energy SOURCES: UTILITY GRIDAND PV SOLAR ELECTRIC SYSTEM Model X7602 .oceted at Horse 60A Service Fused Rated Disconnect 1 Neutral to Ground Bond Manual Diawmet i1rtY W'�SNlraorr HmborEmart I 4 Batlery J�L\/J\—J #8LLL2&nmal #10 LL nd In n Ground n 3/4' Conduit 98 Ground LLL2 nouto •'- In Min 1/2' In In3/4'Condwt 2M Conduit 31 InwNn EGCaaFe Pika Energy critic2oad+ Model X7602 125A M LI,L2 & neutral Located at Hangar 410 Ground In Min 3/4' Conduit 2 Main Distribution Panel — 200A Located at Hanveer Locatedatflorae Utility AC Disco' j � 60A Non-FusedDisconnect iscon act I , \ 910 LI,L2 #g Ground PV Link Optimizer Per string In Min 12• Conduit Note: -All wiring to meet the 2014 NEC and Florida electric codes. 60A Disconnect -Type of conduit to be determined on site by contractor. Must be metal if DC ran interior. C my`pwcm sartwrorxr vP,osc,msro: sw.-ronwwsnes' � _AMa,lfia,�., _vroamax•°. i I _ 3rrl1EAx0.R Figure 690.56(C)(1)(a) Label for PV Systems that Shut down the array and the conductors leaving the array Main Disconnect (2) 200A Main .,an Godwin Engineering an Design, LLC 8378 Foxtail Loop Line side Pensacola, FL 32526 Tap FFF D. Chad Godwin, PE 'j I III Chad@godwineng.com Al I' ea B GEC NOTES Provide a grounding electrode system for an ungrounded system per 690.47(C)(3). . GEC must be installed per 250.64 . GEC must be continuous un-spliced or irreversibly spliced from inverter to existing service ground system or continuous from the arrays to the existing service ground system. - If GEC is not continuous from the army to the existing service ground an additional ground system must be provided from the artays to a grounding electrode per 690.47(D) - GEC must be min #8 AWG and installed in conduit Customer Info: Valle Cluperger 15370 Skyking Dr. Portt- St. Lucie, FL 34987 561-758-9688 Date' Drawn by Checked 1 Rev #: 00 Rev Date: Page: Apply to each DC disconnect/inverter Apply to each Inverter Apply to Disconnects Apply to each J box, combiner box, disconnect,and device where energized, ungrounded circuits maybe exposed during service. Apply to MSP Apply to Disconnects 4628 Eagle Falls Place, Tampa, FL 33619 1-888-801-2030 11.13.19 NM IV 7' 4' Splice Bar 0 Roof Tech Mini's 81 UFO's 90 Sleeves/End Caps 36 Solardecks 0 Ground Lugs 9 30'-611 Inverter Type: PV Panel: Racking: Total Wattage: Roof Type: Wind Load: Fastener Type: R-1 # Modules (36) Pitch: 20' Azimuth: 180' Godwin Engineering an Design, LLC 8378 Foxtail Loop Pensacola, FL 32526 D. Chad Godwin, PE Chad@godwineng.com Max cantilever is 16" as per manufacturer spec. Max Cantilever = Max Span * 61)=48*61)=16" Pika (36) Silfab 31OW Iron Ridge 11,160W Metal 7 to 27 Deg Use Roof Tech Mini's Customer Info: Vasile Ciuperger 15370 Skyking Dr. Date: Port St. Lucie, FL Drawn by 34987 Checked 1 Rev #: 00 561-758-9688 Rev Date: ilIt I111\\k 4628 Eagle Falls Place, Tampa, FL 33619 1-888-801-2030 11.13.19 NM Silfab_ SOLAR WAME INDUSTRY LEADING WARRANTY All our products include an industry leading 25-year product workmanship and 30-year performance warranty. 35+ YEARS OF SOLAR INNOVATION Leveraging over 35+ years of worldwide experience in the solar industry, Silfab is dedicated to superior manufacturing processes and innovations such as B)facial and Back Contact technologies, to ensure our partners have the latest in solar innovation. NORTH AMERICAN QUALITY Silfab is the largest and most automated solar manufacturer in North America. Utilizing premium quality materials and strict quality control management to deliver the highest efficiency, premium quality PV modules 100% made in North America. Electrical Specifications Test Conditions ;SILFAB STc - onocrystalline - ` NOR Module Power(Pmax) WP 310 234 Maximum power voltage max) V 33.05 29.7 Maximum power current (I max) A .9:38' 7.88 Open circuit voltage oc v t40.25-.. 37.2 Short circuit current(Isc) A -9.93�, 8.14 Module efficiency % :19:0. 17.9 Maximum system voltage (VDC) V 1000 Series fuse rating A 20 I Power Tolerance W -01+5 Measurement mndidans: STC 1000 W/m2 • AM 1.5 • Temperature 25 pC • NOCT 800 W/m] • AM 15 • Measurement uncertainty 53% Sun simulator caribradon reference modules from Fraunhofer Institute. Electrical charactedstla may vary by]5%and power by-01+5W. ,Temperature Temperature Coefficient Isc %/K i • 0.03 - I Temperature Coefficient Voc .%/K -1 -0.30 Temperature Coefficient Pmax %/K i' % 0.38 1 - -- - NOCT(t 2*C) 11 °C 45 O erating temperature . 'C (, -401+85 Mechanical Properti6i Module weight (± 1 ) p Components - k I _ d9- I Dimensions (H x L x D; x l mm) • mm 1656 x 990 x 38 Maximum surface load (wind/snow)* N/m2 2400,Pau0werd./.5400 Pa'downward. Hail impact resistance m 25 mm at 83 km/h Cells I -160-Sf monoc. stall(ne'-4ar-5'busbarnl 56.75x 156.75 mm,. I Glass 3.2 mm high transmittance, tempered, antireFlective coating Backsheet Muldla er polyester -based Frame P Anodized Al (Black) - I Bypass diodes 3 diodes-45W12A, IP67/IP68 Cables and connectors (See installation manual) ). .1200.mmo 5.7 mm (4'mm2)7 MC4 compadble -SILFABRA:Mj���� Warranties Module productworkmanshi warranty I 25: ears** I 30 years k 97% end of 1- year Linear power performance guarantee z 90% end of 120, year a 82% end of 25' year z80%end of 30' ear Certifications orocrys ULC ORD C1703, UL 1703, IEC 61215, IEC 61730-1 and IEC 61730-2 Certified. Product FSEC and CEC listed. IEC 62716 Ammonia Corrosion, IEC 61701:2011 Salt Mist Corrosion Certified UL Fire Rating: Type 2 (Type 1 on request) Factory IS09001:2015 I *Please refer to the Safety and Installation Manual for mounting specifications. **12 year extendable to 25 years subject to registration and conditions outlined under "Warranty' at www.si Ifabsolar.com. A Warning: Read the installation and User Manual before handling, installing and operating modules. pturoy� Third -party generated pan files from (/(� 101� 10 Modules Per Pallet: 26 Fraunhofer-Institute for Solar Energy II is Pal lets Per Trudc 36 Systems ISE are available for download at `I pNV GL IN Modules Per Truck: 936 www.silfabsolar.eom/downloads eaw.D. pnmmartcomry "rZim' Silfab Solar Inc. 240 Courtneypark Drive East S i Ifa b \%_%w Mississauga ON L5T2Y3 Canada Tel +1 %5-255-25o1 I Fax +1905-696-0267 Info@silfabsolar.com I wvwv.slifabsolar.com fisGu. ®® Inc.SlIfab Solar ■. 800 Cornwall Ave Bellingham WA 98225 USA Tel +1 360-569-4733 d,l d OlpuMn Nob B D M] i mmnro mN t u rmw.vmm w l-1 26 G.] Gmu W. Da Db�mn•mmm Td�een"v Nl,mYeictl]me ppMp,AnmoY o? Pika v ENERGY Pika Islanding Inverter X7602 and X11402 A single -inverter solution for simplified solar -plus -storage Solar-plusstarage is simple with the Pika Islanding Inverter. This bi-directional, REbus"-powered inverter offers a simpler, more efficient design for integrating smart batteries with solar. Ideal for self -supply, backup power, zero -export and energy cost management, the Pika Islanding Inverter is our most powerful, feature -rich inverter yet. Feature Overview: • Single inverter for grid -tied solar with smart battery integration • Simplified system design: No autotransformer or battery inverter needed • User -selectable modes for backup power, self-supply,time-of-useand zero -export • Free online monitoring included via REvlewDashboard AC OUTPUT/ GRID -TIE Model X7602 Model X11402 Unit Note Rated AC Power Output 7600 11400 W - AC Output Voltage 120/240,10 1201208, 30 VAC - AC Frequency 60 60 Hz - AC OUTPUT/ BACKUP Rated AC Backup Power Output 8000 8000 W - Maximum ACBackup Power Output 12000 12000 w - AC Backup Output Voltage 1201240,10 1201240,10 VAC - AC Frequency 60 60 Hz - ACCircuitBreaker 50 50 A Integrated THD(voltage) 42% <2% - - DC INPUT DC Input Voltage Range 360-420 360-420 VDC - Nominal DC Input Voltage 380 380 VDC REbus" Max Input Current 20 30 A - Ground -Fault Isolation Transformerless, Ungrounded Yes Yes - Integrated, certified DC INPUT/BATTERY Maximum Continuous Power 8000 12000 w Internal DC Distribution Breakers 4x 2p30A 4x 2p30A - 2p DC breakers DC Fuses on Plus and Minus 40 40 A Field replaceable 2-pole Disconnection Yes Yes - Integrated EFFICIENCY Peak Efficiency 97% 98% - CEC Weighted Efficiency 96.5% 97.5% - - �? Pika U ENERGY Pika Islanding Inverter X7602 and X11402 OPERATIONAL FEATURES AND MODES Specification Unit Note Yes Genset Integration In progress - - DCLoadSupport Yes - GridSupport - Zero Export Yes - - ADDITIONAL FEATURES STANDARDS COMPLIANCE Rule 21, Rule 14H Emissions DIMENSIONS AND INSTALLATION SPECIFICATIONS Min -Max Operating Temperature -20 to+50 °C Protection Rating NEMA3R - Enclosure Type INSTALLATION GUIDELINES Battery Types Supported Coral' and Harbor' smart 330 inverters offer !standing for 10load% 4Modbus, @2018 Pika Energy Inc. All rights reserved-MC004-10 Learn more at wwwpika-energycom-made in the USA® @2018 Pika Energy Inc. All dghtsresewed-M0004-10 Learn mare at www.pikaenergycom-made in the USAF �? P I ka PV LinkTM E N E R G Y S2500 Series substring optimizer Advantages: Fast, simple installation Lower failure risk than module -level optimizers _ Rapid Shutdown compliant Accurate monitoring for each substring p .. Ground -fault protection Robust ceramic capacitors a' Features: Quick connections with MC4 connectors r. 250OW capacity = Compatible with high -voltage smart batteries 'rl_?y Cost-effective solution for high-performance PV 25-year limited warranty 'f:.. 0_ • :.. Fast. Flexible. Safe. PV Link is the simple solar optimizer for quick installation and long-lasting performance. Connect as few as two or as many as nine PV modules to each PV Link to overcome shading and challenging roof lines. Specification PV Link Model S2501 Unit Rated power 2500 W Peak efficiency 99% MPPT voltage range 60-360 VMP Max Input voltage 420; max when cold VOC Max output 420 VDC Nominal output (REbus") 380 VDC Max output current 8 A Standby power <1 W Topology Boost converter Protections Ground -fault protection Max operating temp 70 °C Remote monitoring Via REviW web dashboard Enclosure Type 3R Weight 7.3 Lb Dimensions 2 x 15.4 x 9.6 In Limited warranty 25 years www.plo energy.com/sale Opika-energy.00m /made In the USA W001-20 20171018-0912 0 Pike Energy all fights reserved ®-A-.IRONRIDGE Solar Is Not Always Sunny Over their lifetime, solar panels experience countless extreme weather levents.Not just -the worst storms in years, but the worst stor{ns in 40 years. High winds capable of ripping panels fro a roof, and snowfalls weighing, enough to buckle�a panel frame. XR Rails are the structural backbone preventing these results. They resist uplift, protect against buckling and safely and efficiently transfer loads inte the building structure.�C Their superior spanning capability requires fewer roof attachments, reducing the numper of roof penetrations and the amount of installation tim�. .mot Force•Stabiliiing Curve Sloped'm6fs generate both vertical and lateral forces on -mounting rails which can cause them to bend and twist. The curved shape of XR Rails spepankrlesigned tc increase strength in both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. Compatible'with Flat&Pitched 0-ofa XR Rails are *60 idge offers. yempatible with M a rangeoftitt leg FlashFcotandoptions for flat other pitched roofgoof mounting attachments:.applicattons.: XR Rail Family XR Rail Family The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific design loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. XR10 XR10 is a sleek, low -profile mounting rail, designed for regions with light or no snow. it achieves 6 foot spans, while remaining light and economical. • 6'spanning capability • Moderate load capability • Clear & black anodized finish • Internal splices available Rail Selection XR100 XR1001s the ultimate residential mounting rail. It supports a range of wind and snow conditions, while also maximizing spans up to 8 feet. • 8'spanningcapability • Heavy load capability • Clear & black anodized finish • Internal splices available XR1000 XR1000 Is a heavyweight among solar mounting rails. It's built to handle extreme climates and spans up to 12 feet for commercial applications. • 12'spanning capability • Extreme load capability • Clear anodized finish • Internal splices available The following table was prepared in compliance with applicable engineering codes and standards. Values are IjHi) based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean 1 Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications. 6-arrosion; Resistant Materials' Alf XR Rails erd made of 6000•sgd6s >. alumlm5rrr aptly, then protected with an - anndized f nish: Anodizing pn an surface And stfucturalcorrosion, while also providing a more attraptive'appearance. - Ike ' 120; I... None - 140. }XR10; XR100 XR1000 160 4.60 r- 160, 30 `160• ` 40 1 GO 5040 16Q I