Loading...
HomeMy WebLinkAboutAPPROVED,Resisto smoothBCIS Home li Log In I User Registration Hot Topics I Submit Surcharge g Stats & Facts I Publications ; Contact Us # BCIS Site Map Links search E Product Approval .USER: Public User m EBAU"PRmyll Menu > ca ' > Application Ust > Application Detail !. FL # FL2569-1119 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Soprema, Inc. (Canada) Address/Phone/Email 1640 rue Haggarty Drummondville, NON -US 00000 (819) 478-2400 me Mathieu@soprema.ca Authorized Signature Marc -Etienne Mathieu memathieu@soprema.ca Technical Representative Marc -Etienne Mathieu Address/Phone/Email 1688 ]ean-Berchmans•Michaud Drummondville, NON -US 00000 (819) 478-2400 Ext3327 me Mathieu @soprema,ca Quality Assurance Representative Jean -Francois Cote, Ph.D. Address/Phone/Email 1640 rue Haggarty Drummondville (888) 811-3145 jfcote@soprema.ca Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer F3 Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Robert J. M. Nieminen the Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 04/10/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL2569 R19 COI Z020 01 „CQ,)#EMINEN ndf Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4798 2011 ASTM D6163 2008 FM 4474 2011 FRSA/TRI April 2012 (04-12) 2012 UL1897 2012 Equivalence of Product Standards Certified By h4s://www.floridabuilding.org/pr/pr_app_dtl,aspx?param=wGEVXQwtDgsKQFEnckB 1... 7/29/2020 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/09/2020 Date Validated 04/09/2020 Date Pending FBC Approval 04/14/2020 Date Approved 06/02/2020 Summa of Products FL # Model, Number or Name Descriptlon 2569.1 Soprema Roof Underlayments Self adhering roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150 Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The design pressure noted herein pertains to underlayment systems used beneath adhesive -set tile systems. Refer to ER EL2569 R19 II 2020 04 06 FINAL ER Fi_2a62-R19 odf Verified By; Robert Nieminen, P.E. PE-59166 Created by Independent Third Party: Yes Evaluation Reports FL2569 Rig AE 202 6 FINAL FR F 569-R19, df Created by Independent Third Party; Yes Section 5.6.4 for details. Back Next Contact Us ;; 26D1_Blair Stone Road, Tallahassee FL 32389 Phq ;�$0-487-1824 The State of Florida is an AA/EEo employer. Copyright 2097-a013_�tata of Florida. ;; prlvAW Statement ; ; AccessIbillU Staterront ;; Refund Statement Under Florida law, email addresses are publlc records, If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Uses rtment with an email address If they have one. The ema 4s provided may be used for official communication with the licensee. However emall addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here , Product Approval val Accept II8I Credit Card �3 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckB 1... 7/29/2020 NEMOJetc. Certificate of Authorization #31455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION .O. Soprema, Inc. Evaluation Report S18010.06.09-R17 1640 rue Haggerty FL2569-1119 Drummondville, Quebec J2C 5138 Canada Date of Issuance: 06/15/2009 (819) 478-2400 Revision 17: 04/06/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in Its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registrotion No. 59166, Florida DCA ANE1983 0. .w,•,a The facsimile seal appearing was authorized by Hobert ,4:Sb'.^ ^=•+••t' 4,•' Nieminen, P.E. on D4/0612020. This does not serve as an elecironicallysigned document. CERTIFICATION OF INDEPENDENCE: I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates, 2. NEMO ETC, LLC Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the product. 5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. m2019 NEMD ETC, LLC NEMO I etc. Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 611 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. ..Pro e rt . 1504.3.1 Wind Resistance 1504.3.1 Wind Uplift 1507.1.1, 1507.2.9.2, R905.1.1, Physical Properties R905.2.8.2 1507.3.3, R905.3.3 Physical Properties FRSA/TRI April 2012 (04-12) Physical Properties TAS 110 Accelerated Weathering 5tand'ard ; . :;, FM 4474 UL 1897 ASTM D1970 FRSAMI April 2012 ASTM D6163 ASTM D4798 Year 2011 2012 2015 2012 2008 2011 Entity_ .:. Ex' amination Reference . .Date. ERD (TST6049) Wind Resistance 2778,07,05 07/15/2005 ERD (TST6049) ASTM D1970/TAS 110 (QC) 531370.03.10-1-R1 04/07/2010 ERD (TST6049) FRSA/TRI 04-12 (OH) S11150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 (OH) S37210.11.11 11/09/2011 ERD (TST6049) ASTM D1970 (MS) S37210.12.11 12/01/2011 ERD (TST6049) ASTM D1970 (MS) S40540.02.13-1 02/19/2013 ERD (TST6049) FRSA/TRI 04-12 (MS) S43530.02.14-1-111 02/21/2014 ERD (T5T6049) ASTM D1970 (BC) S44870.04.14-2 04/02/2014 ERD (TST6049) ASTM D1970 (QC) 544870,04.14-3 04/02/2014 ERD (TST6049) ASTM D1970 (OH) 544870.04.14-1 04/10/2014 ERD (TST6049) ASTM D1970 (MS) S44870.04.14-4 04/10/2014 ERD (TST6049) ASTM D1970 (OH) S40540.10.14 10/31/2014 ERD (TST6049) Tensile Adhesion / Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD (TST6049) Wind Resistance SDPC-SC14045.05.17-RI 06/07/2017 M-D (CER1592) HVHZ Compliance 18-0329.03 06/28/2018 ICC-ES (EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 NEMO (TST6049) ASTM D1970 /TAS 110 (QC) SOPC-SC8970.08.15-R1 04/25/2018 NEMO (TST6049) Wind Resistance 4-SOPC-18-003.08.18 08/27/2018 NEMO (TST6049) ASTM D4798/D1970 (OH & MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO (TST6049) Tensile Adhesion / Long Term Aging _ 4p-D0W-I9-SSLAP-01.A.R2 02/10/2020 NEMO (T5T6049) Peel adhesion (existing underlayments) 4j-SOPC-I9-SSUDL-04,A 03/12/2020 PRI (TST5878) ASTM D1970 (MS) SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control MLA File No. R27605 05/08/2019 UL, LLC (QUA9625) Quality Control Service Confirmation 07/19/2017 NEMO ETC, LLC Evaluation Report $18010.06.09-R17 Certificate of Authorization #32455 6TH EDITION (2017) FIX NON-HVHZ EVALUATION FL2569-R19 Soprema Roof Underlayments Revision 17: 04/06/2020 Page 2 of 8 NEmo I etc. 4::PRC�DUC7 DESRIhT[ON Rraducit , :". .. ": Spciircatton description ;. 4.1 Lastobond TU HT ASTM D1970 and Gulfport, MS self -adhering, non -woven polyester fabric surfaced, FRSA/TRI April 2012 SBS modified bitumen roof underlayment 4.2 Lastobond Shield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch 4.3 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS 40 modified bitumen roof underlayment 4.4 Lastobond Shield HT ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4.5 Lastobond Pro HT-N ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch 4.6 Lastobond Pro HT-S ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4,7 EnviroShield ASTM D1970 Drummondville, QC self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment 4,8 Lastobond 195 ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand -surfaced, Wadsworth, OH SBS modified bitumen roof underlayment 4.9 Lastobond Eaves ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, sand -surfaced, Protection Sheet Wadsworth, OH SBS modified bitumen roof underlayment 4.10 Lastobond Eco ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH 4,11 Lastobond Smooth Seal ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, HT Wadsworth, OH SBS modified bitumen roof underlayment 4.12 PrimeSource Grip -Rite ASTM D1970 Gulfport, MS self -adhering, glass -mat reinforced, film -surfaced, Smooth Seal HT Wadsworth, OH SBS modified bitumen roof underlayment 4.13 RESISTO LB1236 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH 4.14 PrimeSource Grip -Rite ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Eave & Valley Protector Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH 4.15 SRS TopShield ICE & ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, WATER DEFENDER Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH 4.16 RESISTO LB1244 ASTM D1970 Drummondville, QC self -adhering, glass -mat reinforced, sand -surfaced, Gulfport, MS SBS modified bitumen roof underlayment Wadsworth, OH 4.17 Colphene FR GR ASTM D1970 and Gulfport, MS self -adhering, fiberglass reinforced, granule- FRSA/TRI April 2012 Wadsworth, OH surfaced, SIBS modified bitumen roof underlayment MEMO ETC, I.LC Certificate of Authorization #32455 6m EDITION 12017) FBC NON-HVHZ EVALUATION soprema Roof Underlayments Evaluation Report S18010,06.09-R17 FL2569-R19 Revision 17: 04/06/Z020 Page 3of8 NEMO I etc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request maybe made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: f _ TABL£ 1' ROOFOVERPY1ONS Wood pr : Slate or Underiayment Asphalt Nail On ' Foam On Metal Composite Composite, ffi Tile Shakes&' ` Shmgle5- $Iate Lastobond TU HT Yes Yes Yes Yes Yes Yes See 55A Lastobond Shield / Pro HT-N / RESISTO SA SMOOTH PLY 40 Yes No No No Yes Yes Lastobond Shield HT / Pro HT-S Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes Lastobond Eaves Protection Sheet/ Lastobond 195 Yes No No No Yes Yes Lastobond ECO / RESISTO LB1236, Grip -Rite Eave & Valley Protector/ TopShield ICE & WATER DEFENDER / Yes No No No Yes Yes RESISTO L61244 Lastobond Smooth Seal HT / Grip- Rite Smooth Seal HT Yes No No Yes Yes Yes Colphene FR GR Yes Yes No I No Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives /underlayment combinations. TAi3LE 1A''ALLDWEI6LE T[LE'QOESIIIE UNDERLAYMeNL COMBINATION51 ,;; Underiayment .., Adhesive Florida Product -Approval Lastobond TU HT Dupont TILE BOND'"" FL22525 ICP Adhesives Polyset® AH-160 FL6332 i Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report S18010.06.09-R17 Certificate of Authorization #32455 6rH EDITION (20171 FBC NON-HVHZ EVALUATION FL2569-1119 Soprema Roof Underlayments Revision 17: 04/06/2020 Page 4 of 8 NEMO I etc. 5.6 Allowable Substrates: SUBSTRAT6�P:: w-CABLE Under[a`yment Primer . .. Subs;rates . Lastobond Shield, Lastobond Pro HT-N, RESISTO SA (Optional) ASTM D41, SMOOTH PLY 40, Lastoband Shield HT, Lastobond Pro HT-S, Elastocol Stick, Elastocol Stick plywood, OSB, Southern Yellow EnviroShleld, Lastobond TU HT, Lastobond Eaves Protection Zero pine (SYP) Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT or ASTM D41 structural concrete Grip -Rite Smooth Seal HT Colphene FIR GR (Optional) ASTM D41 Plywood ASTM D41 structural concrete Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Dens Deck Prime; SECU ROCK Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, (Optional) Elastocol Stick Zero Gypsum -Fiber Roof Board; Grip -Rite Eave & Valley Protector, TopShield ICE & WATER ASTM D226, Type I or II felt; DEFENDER, RESISTO LB1244, Lastobond Smooth Seal HT, Sopra-G; Modified Sopra-G Grip -Rite Smooth Seal HT or Colphene FR GR Existing sand -surfaced, glass- RESISTO LB1236, Grip -Rite Eave & Valley Protector or fiber surfaced, mineral -surfaced TopShield ICE & WATER DEFENDER RESISTO EXTERIOR PRIMER or film -surfaced roof underlayment* * Final acceptance of any existing substrate in a reroof (tear -off) installation !sat the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 5.6.1 Soprema recommends priming with Elastocol Stick; Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.6.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment 5.6.3 For installation under mechanically attached prepared roof coverings, insulation or coverboard shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1897. 5.6.4 For installations under mechanically attached prepared roof coverings, base sheet shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base sheet shall be attached in accordance with FRSA/TRI April 2012 (04-12) or Section 5.6.5 herein. 5.6.5 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. NEIVIO ETC, LLC Evaluation Report 516010.06.09-R17 Certificate ofAuthoriration #32455 6- EDITION (2017) FOC N0N-HVHZ EVALUATION F1.2569-1119 Soprema Roof Underlayments Revision 17: 04/06/2020 Page 5 of 8 `,..J NEMO I etc. #1 Maximum Design Pressure = -45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #2 Maximum Design Pressure = -67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #3 Maximum Design Pressure=-120.0psf: Deck: Min. 15/32-11nch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction, Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end - laps. Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #4 Maximum Desi n Pressure = -150.0 Psf: Deck: Min, 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps. #5 Maximum Design Pressure = -60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT, self -adhered; thoroughly rolled using hand roller and/or weighted roller in accordance with Soprema requirements to ensure no voids no bridging at side and end -laps 5.6.5.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. NEW ETC, LLC Evaluation Report S18010.06.09-R17 Certificate ofAuthorization #32455 671 EDITION (20171 FBC NON-HVHZ EVALUATION FL2569-R19 Soprema Roof Underlayments Revision 17: 04/06/2020 Page 6 of 8 NEMO I etc. 5.6.5.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609, In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, Grip -Rite Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Smooth Seal HT or Grip -Rite Smooth Seal HT small not be left exposed for longer than 90- days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage limitations (TA5103 per FRSAZTRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. r: " ,„ , ,;TABS E r, T�1E SLIPI!AGE LIiVEI ATION3 5OR Q 2 Q S li [1LE INSTALLATION;" .. .. -.-_ ;:. Underlaymenf: The Profile ;=$tag,gg Method Maximum �_ 51op:e Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high on slope, as shown below) 6:12 iii Lastobond TU HT,;n, Lugged Moak- Colphene FR GR Flat Max. 10-tile stack 5:12 Lugged Max. 10-tile stack 6:12 NENIO ETC, LLC Evaluation Report 518010.06.09-1137 Certificate of Authorization #32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION F1.2569-1119 Soprema Roof Underlayments Revision 17; 04/06/20ZO Page 7of8 NEMO etc. 6 INSTALLIMTIDN _ 6.1 Soprema Roof Underlayments shall be installed in accordanceµ with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER (if applicable). 6.2.1 Installation of RESISTO LB1236, Grip -Rite Eave & Valley Protector orTupShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236, Grip -Rite Eave & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underlayments, contact RESISTO technical support. 6.3 L.a. stobond TU,HX, Lastobond Shield, Lastobond Pro FIT N, RESISTO SA SMOOTH PLY 40 Lastobond ShieldHT,=; „ Lastabon' Pro HT S, FnulroShield, Las obond Eaues Profectlan sheet, Lastobond 95 Lastobonpt Eco, Lastobond'; Smooth Seal WT,,GXip Mite Smooth Seal`H"T, RESISTO LB1236, Gcip lilts Eaive & Valley Protector; TopShield'ICE & 1NATER;DEFENDER, RE51ST0 LB1244 arCOpheneFR,GR 6.3.1 Non -Tile Applications: Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507,11 or FBC Residential Table R905.1.1 for the type of prepared roof covering to be installed, and Soprema published requirements. 6.3.2 Tile Applications Lastobond TU HT or Col .hene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual for Self -Adhered Membrane, and Soprema published requirements. For mechanically fastened the roofing over a 2-ply system, consisting of Base Sheet and Self -Adhered Membrane, fastening of the ASTM D226, Type II base sheet shall be in accordance with Soprema requirements, but not less than that the densities set forth in FRSA/TRI April 2012 (04-12), Table 1. For foam -on tile applications (Lastobond TU HT only), reference is made to Section 5.6.5 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment, See Table 3 herein, and Soprema published requirements for tile staging, - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report S18010.06.09-1117 Certificate of Authorizotlon #32455 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1119 Soprema Roof Vnderlayments Revision 17: 04/06/2020 Page 8 of 8