Loading...
HomeMy WebLinkAboutLetter; Ciuperger - Residential PV Roof Mount InstallationGODWIN ENGINEERING AND DESIGN, LLC 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 1 chadCa)godwineng com November 14, 2019 To: St. Lucie County Building Division 2300 Virginia Avenue Ft. Pierce, FL 34982 Re: Ciuperger - Residential PV Roof Mount Installation 15370 Skyking Drive Port St. Lucie, FL 34987 Plan Reviewer, E TPerm�thn i This letter is regarding the installation of a new roof mounted Solar PV System on the existing residential structure at the address above. I have reviewed the attachment plan and have determined that the roof mounted PV system is in compliance with the applicable sections of the following Codes as amended and adopted by the jurisdiction: 2017 Florida Building Code 6th Edition, FBC ASCE 7 Min. Design Loads for Buildings & Other Structures Per 2017 FBC, the Roof Mounted PV system will be subject to the following design criteria: Design Wind Speed(V i,) - 160mph 3sec gust, Exposure Category - C The PV System consist of the modules, railing, and connection hardware. The system will add a dead load of approximately 3 psf to the roof. The existing roof covering is Asphalt Shingle with min. 1h'! plywood decking and 2" x 4" roof trusses 24" O.C. The roofing, decking, and roof trusses are in good condition. The existing structure will be adequate for supporting the additional PV dead load and ind loads. The securement method of the PV system is to be Flush mounted to the asphalt shingle roof with Ironridge railing and the Roof -Tech RT mini mount. The attachments can be attached up to 48" apart and should be staggered, where possible, to allow distribution of the design loads evenly to the structure. The mounts shall be installed with a min. 2 J 5.0 x 60mm wood screws with minimum 2" thread length directly to roof truss. ST.LUCIE COUNTY Please see attached documents and contact me dP1dlNdtpwibave any questions.C. FILE CC) BLDG: \\\D#N`tCEpGo� DATE: ` Q, V Sincerely, ELE�'�/ _ * .8 360 ; D. Chad Godwin, PE 81360 DATE:/1�7-Y'5 =-a ; * — Exp.02/28/2021 PLUMB: ®` S TEOF '1- DATE: �.T IDP, , #�!/\�� MECH: //s/ ----- G�\\\ DATE111111\I000 BUILDING DESIGN PROPERTIES SYMBOL VALUE UNIT BASICWINDSPEED V 160 mph Figure 26.5.1C, page 249a ROOF PITCH 0 >)[02) iF degrees MEAN ROOF HEIGHT It ROOFSETBACK Lt ADJUSTMENT FACTOR FOR BUILDING HEIGHTANO EXPOSURE Qa3 Figure 30.5.1, pg 347 TOPIGRAPHICAL FACTOR Figure 26.8-1, pg 252 EXPOSURE EFFECT-VEWINDAREA sf ZONEI ZONE2 20NE3 VARIABLE DESCRIPTION SYMBOL VALUE VALUE VALUE UNIT REFERENU:MM7.10 NET DESIGN WIND PRESSURE (UPLIFT) P.". -02.1 73.4 -108.5 psf Figure 30.5.1, pi,346 N ET DESIGN WIND PRESSURE (DOWN) P..� 1 20.3 20.3 20.3psf Figure 30.5.1. IF, 346 NET DESIGN WIND PRESSURE (UP) PMw -50.94 438.81 -131.2 psf Calculation P„ew=AXKnXPmm NET DESIGN WIND PRESSURE (DOWN) Pmdd.n 1 24.56 24.5624.56psf Calcination: Pda = A X K"X P_ue DESCRIPTION SYMBOL VALUE VALUE VALUE DEAD LOAD D SNOW LOAD S DESIGN WIND LOAD W ASO DESIGN LOAD(UPUFT) DOWNFORCECSES pdd.y. DOWNFORCECASE2 pdµ, DOWNFOROECASE3 Pd 0-131.29-99.37 H3 327.5621.42 DESIGN FARORS & CALCUTATONS FOR THE USE OF RT MINI TO ROOF TRUSS DESCRIPTION SYMBOL VALUE VALUE VALUE MODULEWIDTH B TOTAL DESIGN LOAD (UPLIFT) P TOTAL DESIGN LOAD(OOWNFORa) P DISTRIBUTED LOAD (UPLIFT) w DISTRIBUTED WAD(DOWNFORCE) w RAIL SPAN BETWEEN ANCHORS POINTS L POINT LOAD (UPLIFT) R POINT LOAD(DOWNFORCE) R L-FOOTOONNECTED BY LAG SCREW TO Roof truss Specific GmviW, G Min. Dia. of lag Screw, 1/4" D Pullout Value of W R of lag screws Thread Length Td Design Pullout Value per Mount Wr SAFTEYFACTOR SF uP1,pr�lr WXs4urr.rl 3:28 3.28 3.28 737.13 -66.47 49.37 27.56 2756 2756 -60.90 .109.01 -16L97 45.20 45.20 45.20 4 4 2 -243.61 .436.05 .325.93 180.81 180.81 90A1 0.5 0.5 0.5 0.25 0.25 0.25 225 225 225 2 2 2 1.5 1.5 1.5 675 675 675 2.77 1.55 2.07 I�i��v 4V�)�id�1P PtY. y�ynmLp. Ll o�e�4bnM l^ePq�"dbbLL) IY�Sa�'-'FYCgd wlWrdl, FW Ivi N IY c.br B..YI.g TT / G.Na Rewp• ❑ au.aiors � [ML XUI,.L.INyX.}wd FM. 1w� LL1IDeai��Yd•I�ah Fa.e-a nan X.s�Ob�4 P.,. UNIT psf Psf psf Pal Calculation: P,,,=D,SORT(0.6)W(asd) Pal Wlculatlon: Pdeio,=I.0D.lDS psf Calculation: Pd,=1.OWLOW psf Calalatlaa P, ,=1.ODL0.755 .75W UNIT R psf Pot PH Calculation w=PB/2 •''""'!ae"a °"'0' pif WlMation:w=PB/24a 2"am'm It be CAlculatlon:R=PUB/2*MWr 2'aaP- Ibs Calnrlatlom R=PLB/Z'P' ""x,a6 P-- Table 11.2A6 ND52005, page 68 (Southem Pine) n bs/In W=1800GV'DV4 n Table LZ, ND52005 W.=W•A of Up d Calculation: SF=WVR (UPli0) .•"%.%GEMS" O��ii X 1 60 F Y OF /���ir���AL ENG\��N