Loading...
HomeMy WebLinkAboutConstruction PlansCONTRACTOR: Master Craft Aluminum F"'-'-'ts DESIGN CRITERIA: • _- Applicable Codes, Regulations, and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood 2. AA ASM 35 and AA ADMI Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 2 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Ultimate Design Wind Speed: Vu T=150 NIPA. Nominal Design Wind Speed: Vaso =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure C 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1- Patio Cover: Non-Habltable, Unconditioned Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" composite panel Elite 2000, 1.09 density foam, Florida Product Approval Number FL 7561-R4. Foundation Design Existine concrete. No additional concrete famine or slab is reauired to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spatting, or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Florida Aluminum Engineering, Inc. 3. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 4. Approved concrete screw anchors to be Simpson Tilen-HD or equivalent. 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or 912 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type 1,- ASTM C 150 I Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining+/- 190 - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bus - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Paris 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for ternites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED ANI`P,-"^OSVRE HAVE BEEN DETERMIN `iSING THE ADVANCED TECHNOLOGY CUuiCIL'S WEBSITE AND GOOGLE EARTH. 8'-3" 3X3XO.093 POST O e O I O !0 j o j 1 00 no W 3X3XO.093 POST 8'-0" E O I 00 3"X48"XO.024" COMPOSITE PANEL 2X3K6 (TYP) 093 IYii.9111 LI -2 7'-6" ........ J 3X3XO.093 POST * 'llp,4 •_ i �2 M LL y r L W w a W J Z Owow, r •, co 0 LU LaiW W tl z to Z W Z Z Qz O d vwi Z N w WLL 0J O O z 1 U DZ51 �Z� ^nZ J � �LLmm n s Q LLJ W p Z air E � 0Z9 o LL W fA to W 0 QF b W 0 d TP 11/22/19 A-1 ALUMMUMMEMBERSDBHNSIOi;" HOLLOW SECTIONS \\\\\\\\11U1 �0 '( *1Ioplto, 2x 2: 2"x2"x0.0445" '• %�(`� °' ��j� �, •� 2x3: 2"x3"x 0.050" 2x4: 2"x4"x0.050" �� ,•(V LL A. 2y i 2x 5: 2"x5"x 0.050" ?Q •y O 0• OPEN BACK SECTIONS 2 o a W R* � J EU Q 1 x2: 1"x2"x 0.040" i 'V a 0. I x3: 1"x3"x 0.045" (5) 1/4" x 4" LAGSWI Q, •� O 03 4�14; 1 114" DIA NEOPRENE FACED WASHER PER PAN ��0 ��'•, % lG�, SNAP SECTIONS •••. •� •Q 2x 2 Snap: 2"x2"x0.045" 2 3 Snap: 2"x3"x 0.050" y /// ...••• x 2 x 4 Snap: 2" x 4" x 0.045" . ,_y:,,x. e:,�t1*t. '�4.'y"J :, t3,`1a'�". +�'v9•',1 , POST Lsftry! r�•.�m>``-s�'CA''s, SELF MATING(SMB) sx. +;� 4Rn y;'ynT' Na:. s v'S:�"'S'¢3s'•`.'^' ` -"� r=•`"a .4 `n. 2 x 4 SMB: 2" x 4" x 0.044"x 0.100" �„�.'w�� m- d. 2X5SMB: 2" x 5" x 0.050" x 0.100" W W 2 x 6 SMB: 2" x 6" x 0.050"x 0.120" 3^COMPOSITE W CL Z 2x7SMB: 2" x T'x 0.05T'x 0.120" i ROOF PANEL 3" 0.062" ALUM m 2x8SMB: 2"x9"x 0.072"x 0.124" ANGLE x RECEINNG CHANNEL zz F- w Z W t0 2 x 9 SMB: 2" X 9" X 0.072"x 0.124'+ EACHSDE OF UPRIGHT EACH SIDE OF UPRIGHT W/(11311"CIA x3"CONCRETE W/910x3/4"TOPAND (4) 316"DIA W z 2XIOSMB: 2"x10"x0.092"x0.398" ANCHORS (2114" EMBEDMENT) BOTTOM AS END CAP THRU BOLTS Q Q C MINIMUM FASTENER EDGE DISTANCE:1/2° THRINTOU BOLTSON TE & U ale" DIA. z 4^ THRU BOLTS THROUGH POSE z d w MINIMUM FASTENER SPACING: 3/4" 2"z S'SMB O z N CONCRETE SCREW ANCHOR: a �. - ° 3" x 3" x 0.093" CA Q LL SIMPSON TITEN HD OR EQUIVALENT c a. .,ILL < li POST 0 SHEET METAL SCREWS fSMS): _ ° - ' ^' e ® ° _ w ITW/BUB,DEXOREQUIVALENT . 'a fL F- e. a LiS� s�1COMPOSITE e z ROOF TO POST CONNECTION Zx3" POST TO DECK CONNECTION DETAILS %�31./ A2 SCALE: NTSQi z SCALE: MS m e q J = (Di° J g L ga w Q W Q W Z2m� 6 Jam•', V oC t7 SO 9 ul LL NOTE 3" COMP ROOF PANEL SELF -MATING BEAM HEADER ATTACHMENT TO FASCIA W/ 1/4" LAGS 0 24" O.C. W/ 1 3/4" EMBEDMENT :+5; ":iP' .FiS're'i rY ';: i•: s. `4� 'r Y;' 3\,')'., `F• y,ti;q`q:, yam, "� '' (5)114"x 4" LAGSW/ FLASHING r;.•,'(!ef.'�i !C <'%u''".'.r�t•.? :^y:r=;P-GY;:T %rL vC�.','i::r•5•3`' 3' `,:y;c r" �t�l''r^1'r lf'.wL:K^S. �:�p„�„ 11/4" DIA NEOPRENE ��;y2'(i'+*^.`•"t Mut isl}.)•`;_,G;!-f,�4`,Y.^S!,n:t�*�.•.`t,EL':.:e. •... o-`,i�.k4;S,;.y"�.. FACED WASHER PER PANEL 3" COMPOSITE ROOF PANEL z' I ❑ «'.i1Uwk NYf�y EXISTING ::2-.';k�}S.-`•:�"jS V�;L;S �.5'�-'1a`;• • ":4. HOST e a a I I W Q .t.'at'!(ht. YiF,+< \ (4) &8" CIA \ \ \ I I g F J THRU BOLT \ \ I I 1z' W W W H N co 2" x 3" x 0.050" \ \ \ I 0 L m KNEE BRACE \ \ I I UPRIGHT 2� V O J d Go 0- \ a; m LL DRAWN BY 2"xG"SMB I 11/2'x 21/6"xI In"x •' TP 3"x3"x 0.093" I 0.062" x 3" LONG ALUM I RECEIVING CHANNEL W/(3) ATE DDRA RA DRAWN POST 912x 3/4"SMS EA FACE& 11/22/19 _- _--- (3) #12 x 314" INTO POST REVISION S-1 COMP. ROOF TO CORNER PNOST 0 4TH WALL DETAIL S-2 KNEE BRACE CONNECTION DETAIL TS A-2 4 SCALE:NTS A 2 SHEE NO: A-2 .. .