Loading...
HomeMy WebLinkAboutHi-Tide - Cuda Gear - 9,000 lb. Permit Drawing - Harsch 8-5-20ENGINEERING REVIEW: BOAT LIFT TOP CARRIER BEAMS AND MOUNTING BRACKETS COMPLY WITh WIND LOAD REQUIREMENTS OF THE 6TH EDITION (2017) FLORIDA BUILDING CODE, PER ASCE 7-10, AND PER DESIGN LOAD REQUIREMENTS OF THE 2015 EDITION ALUMINUM ASSOC/AT/nN'.s ALUMINUM DESIGN MAN BEAMS AND MOUNTING BRAC INSTALLED PER Hl -TIDE INSTRUCTION` EXCEED ULTIMATE DESIGN WIND SPE 180 MPH (EXPOSURE CATEGORY C BOATS ARE TO BE REMOVED FROM I LIFTS PRIOR TO A MAJOR WIND EV) PILINGS: PILING PENETRATION TO BE 10' INTO THE SAND BOTTOM OR 5' INTO ROCK STRATA, SUB -SURFACE CONDITIONS CAN VARY GREATLY, THE CONTRACTOR SHALL VERIFY ALL PILE CAPACITIES TO COMPLY WITH 2017 FBC. ALL PILINGS TO BE 8" MINIMUM DIAMETER 2.5 C. C. A PRESSURE TREATED WOOD, PRE -STRESSED CONCRETE OR COMPARABLE EQUIVALENT. ELECTRICAL REVIEW: 1/2 HP ELECTRIC MOTOR 8.8 AMPS @ 115V EACH 4.4 AMPS @ 230V EACH QUANTITY: 2 TOTAL WATTS: 2024 DESCRIP770V Digitally signed by Roger M BABER DN: c=US, o=Sustainable Earth 4�)x Azt_� Engineers dba MCR Engineers, oger Baber, F.E. ou=A01410D0000017183ADA33 C00001860,cn=RogerM BABER Date: 2�aGRXd 5 1°4:13:23 -04'00' M e ooOo a° 6 \ C E IV S ® 00°00 O " NO. 43855 � STATE OF 41 o ORI DP��4v 00000°$ 0p0 N A . ROGER SABER P.E. NO. 43855 CR PROFESSIONAL ENGINEERING C.A. NO. 26967 1014 NW P/NELAKE DR. STUART, FL 34994 ING MOUNTING TABS MUM (2) 3/8" DIA. SS LAG TS FOR WOOD PILING OR CONCRETE ANCHORS FOR CRETE PILINGS PER PILING IUIRED.M/N/MUM (2) 3/8" SS CARRIAGE BOLT FOR Ail 114CH/NG MOUNTING TAB TO LIFT REQUIRED PER PILING. MOUNTING TAB CONSTRUCTED FROM 1/4" X 2" ALUMINUM 6 0 6 1- T 6 F L A T B A R. 9,000 LB. CODA GEAR BOA TLIFTS AND MARINE PRODUCTS BOAT LIFT (2017 FBC) �� a 4050 SELVITZ ROAD FORT PIERCE, FL 34981 R. HYDE SCALE: NTS DATE: 4/17/20 RE V.- 1 1-800-544-0735 www.hi-tide.com