HomeMy WebLinkAboutHi-Tide - Cuda Gear - 9,000 lb. Permit Drawing - Harsch 8-5-20ENGINEERING REVIEW:
BOAT LIFT TOP CARRIER BEAMS AND
MOUNTING BRACKETS COMPLY WITh
WIND LOAD REQUIREMENTS OF THE
6TH EDITION (2017) FLORIDA BUILDING
CODE, PER ASCE 7-10, AND PER DESIGN
LOAD REQUIREMENTS OF THE 2015
EDITION ALUMINUM ASSOC/AT/nN'.s
ALUMINUM DESIGN MAN
BEAMS AND MOUNTING BRAC
INSTALLED PER Hl -TIDE INSTRUCTION`
EXCEED ULTIMATE DESIGN WIND SPE
180 MPH (EXPOSURE CATEGORY C
BOATS ARE TO BE REMOVED FROM I
LIFTS PRIOR TO A MAJOR WIND EV)
PILINGS:
PILING PENETRATION TO BE 10'
INTO THE SAND BOTTOM OR 5'
INTO ROCK STRATA,
SUB -SURFACE CONDITIONS CAN
VARY GREATLY, THE CONTRACTOR
SHALL VERIFY ALL PILE
CAPACITIES TO COMPLY WITH
2017 FBC. ALL PILINGS TO BE
8" MINIMUM DIAMETER
2.5 C. C. A PRESSURE TREATED
WOOD, PRE -STRESSED CONCRETE
OR COMPARABLE EQUIVALENT.
ELECTRICAL REVIEW:
1/2 HP ELECTRIC MOTOR
8.8 AMPS @ 115V EACH
4.4 AMPS @ 230V EACH
QUANTITY: 2
TOTAL WATTS: 2024
DESCRIP770V
Digitally signed by Roger M
BABER
DN: c=US, o=Sustainable Earth
4�)x Azt_� Engineers dba MCR Engineers,
oger Baber, F.E.
ou=A01410D0000017183ADA33
C00001860,cn=RogerM BABER
Date: 2�aGRXd 5 1°4:13:23 -04'00'
M e ooOo
a° 6 \ C E IV S ® 00°00
O
"
NO. 43855 �
STATE OF 41 o
ORI DP��4v
00000°$ 0p0 N A .
ROGER SABER
P.E. NO. 43855
CR PROFESSIONAL ENGINEERING
C.A. NO. 26967
1014 NW P/NELAKE DR.
STUART, FL 34994
ING MOUNTING TABS
MUM (2) 3/8" DIA. SS LAG
TS FOR WOOD PILING OR
CONCRETE ANCHORS FOR
CRETE PILINGS PER PILING
IUIRED.M/N/MUM (2) 3/8"
SS CARRIAGE BOLT FOR
Ail 114CH/NG MOUNTING TAB TO
LIFT REQUIRED PER PILING.
MOUNTING TAB CONSTRUCTED
FROM 1/4" X 2" ALUMINUM
6 0 6 1- T 6 F L A T B A R.
9,000 LB. CODA GEAR BOA TLIFTS AND MARINE PRODUCTS
BOAT LIFT (2017 FBC) �� a 4050 SELVITZ ROAD
FORT PIERCE, FL 34981
R. HYDE SCALE: NTS DATE: 4/17/20 RE V.- 1 1-800-544-0735 www.hi-tide.com