Loading...
HomeMy WebLinkAboutProduct Approval (5) 1b� �. 'RAM, .: �� > p p GT PFR# � AL � s�":kF�u � ?a:'d+ � �, v4.tray �y � x !`mssd,,s, r '�#� :��'Sr,�. �,�'+'^ p §se wd 45•,. � t�r°.e4:���... t SVCRIMP 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.13 R3 • , , F •• 1 • �A 74, G' J. } •/,�� 3Q 8;� � �� o���. i� �k���� F �; v�� �IY��� r����i 9 Ig a .�"K r.•#s.,��es, x +tr,-s. '�,....,,...F� ...i+�.,r. g „te,�..`.ls.,.,•.�'.,.�'4t.. ,.. r.. .�'.�,m..1 _ w . KUHN ENGINEERING, `LLC 1.200 CLINT MOORE RD. S-0JTB),B'OCA RATON, FL 33487 F'.L COA #3Q464 LUN, FL 33487 • FL.COA#30464 nal 00, ell, .. Gulfcclo � . ' j SUPPLY & MANUFACTURING r 5VCRIMP„�ya • "i 26 GA. • • ROOF PANEL OVER • • ;V FLORIDA PRODUCT APPROVAL NO. I,1651% R3 1TM Design.Procedure: For roofs within the,parameters listed on the load table,fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed,on the.load table, design wind loads shall be determined for each project in accordance,with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The.maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone.Refer to,current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.13 R3•OCTOBER 5,2017 ENGINEEROG, LLC 1200 •• SU UE • • • 3487 FL FL 3 • a A�I®� ° G lalfC�i at �� SUPPLY & MANUFACTURING 26 GA. 5VCRIMP ROOF PANEL OVER 15/32" PLYWOOD T 7 FLORIDA PRODUCT APPROVAL NO. 1165.1.13 R3 �' �• sl ii'.� a.�t ''L 4, TM ENGINEER LOAD TABLE:26 Ga. SVCrimp Roof Panel over 15/32"Plywood a' '4r Ni r1 E3ullclt� s 17�aving a„Roo��Me�n �leghi S,�2Or tfl�,hoof Slops 2 2112 12 !12 Gabletp;Roof,tNlttc�Speeds 120 n ,;, y#,-i 1�80rrlph;Exposures Risk.Qatego�y?�! ,Eclosd Buddltig based on Flonda Bulldlg„Cole :.. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN.1/4” (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING 1 ZQN ,Fr1 s f#c} 15 1 5"q yY2 PIyVGood 3a `16�'TnYPE41 y 16"71fREs1 k16 TYPE 1FI "Z6"TYPE 1 `x16,';'f YPE;11 ,16',TYPE 1� 16",°TYPE 1 1 { ZONE 2 #9-15x1.5" Plywood 16”TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 16"TYPE 1 P, rZOItE �'re #9-15kTYPE<<1 `' � ) " TYPE 2 16 TYPE 1 16 TYPE 1 16 TYPE 2 6 Rit�W`,'3.` F,�" j. ,r: r 7 sP..1°'+ff la'xU, ,sY.>r r,.zr . !.:- Se ..ev n"`Y!,, r.iul.,�.. ?'„4,)�+ { •a"i4'. >7„ .'kyr 1.)PANEL DESCRIPTION: 5V CRIMP, MIN.26 GA,,GRADE 80, 24"COVERAGE. 2.)PANEL FASTENER:#9-15X1.5” HWH WITH SEALING WASHER W/MIN. Y4" PENETRATION. 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:-94.25 PSK? 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN,-131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING: MIN.Is/D"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD =0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE 2 HIP ROOF ZONE 3—,,,?, Note:Dimension(a)is defined as 10%of the minimum width of the building or J — a 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be ---— — - -——-- �' — less than either 4%of the minimum width of the building or 3 feet. RIDGE �' ' ' TYPE 1 FASTENER PATTERN --------- ,' --------- �� (1) #9-15 x 1-1/2" HWH w/Sealing Washer ZONE1 �� \�� 12 12� G G /------------------\� —EAVE At Panel Lap—� ZONE 2 GABLE ROOF �— ----------------- a TYPE 2 FASTENER PATTERN RIDGE ; (1) #9-15 x 1-1/2" HWH w/Sealing Washer +— -�-------------------- Aa I ZONE 1 I I \ ZONE3 VEAVE FL#11651.13 R3•OCTOBER 5,2017