Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MANJ
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HOMECRETE - BYERS Builder Name: HOMECRETE Street: 8662 LONESOME PINE TRAIL Permit Office: city, Stale, Zip: FORT PIERCE, FL , Permit Number: Owner: BYERS RES. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1424.0 soft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.5 1264.00 W b. Frame - Wood, Adjacent R=11.0 160.00 ft' 3. Number of units, if multiple family 1 c. NIA R= ft' 4. Number of Bedrooms 3 d. NIA R= ft' 5. Is this a worst case? No 10. Ceiling Types (1852.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1852.00 ft2 6. Conditioned floor area above grade (fi 1852 b. NIA R= ft2 Conditioned Floor area below grade (ft2) 0 . R 11. uctsN/A R ft2 7, Windows(205.0 sgft.) Description Area a. Sup: Attic, Ret: DINING ROOM, AH: DINING RO 6 250 a. U-Factor: Dbl, U=0.33 205.00 ft' SHGC'. SHGC=0.25 b. U-Factor: N/A W 12. Cooling systems kStu/hr Efficiency SHGC: a. Central Unit 33,0 SEER:14.00 c. U-Factor: NIA ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 33.8 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 6.363 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (1852.0 soft.) Insulation Area F. 0.950 a, Slab -On -Grade Ede Insulation R=0.0 1852.00 ft2 9b. Conservation features b. NA R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.111 Total Proposed Modified Loads: 55.35 PASS Total Baseline Loads: 60.12 lions covered by I hereby certify that the plans andfthe'Florida Review of the plans and O�'SKE STgl�, this calculation are in compliance Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code, xu„•- iR.,•',;2 PREPARED BY: Before construction is completed _- DATE: this building will be inspected for compliance with Section 553.908° ° I hereby certify that this b i i g, gre is in compliance with the Florida Energy a Florida Statutes. c0D WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air'handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/26/2020 11:37 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HOMECRETE -BYERS Building Type: User Owner Name: BYERS RES. # of Units: 1 Builder Name, HOMECRETE Permit Office: Jurisdiction: Family Type: Single-family Bedrooms: 3 Conditioned Area: 1852 Total Stories: 1 Worst Case: No Rotate Angle: 90 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Slock/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 8682 LONESOME PIN St. Lucie FORT PIERCE , New/Existing: New (From Plans) Comment: FL, CLIMATE Design Location TMY Site Design Temp 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO�EACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1852 18520 SPACES Number Name Area 1 BED 1 174 2 BATH 2 60 3 BED 2 168 4 DINING ROOM 301 5 GREAT ROOM 225 6 NOOK 88 7 KITCHEN 200 8 LAUNDRY 70 9 MASTER TOILET 26 10 MASTER BATH 144 11 WIC MASTER INT 48 12 WIC MASTER EXT 48 13 MASTER SUITE 300 Volume Mohan Occupants 1740 No 1 600 No 0 1680 No 1 3010 No 0 2250 No 0 880 No 0 2000 No 0 700 No 0 260 No 0 1440 No. 0 480 No 0 480 No 0 3000 No 2 Bedrooms 3 Infll ID 1 1 1 1 1 1 1 1 1 i 1 1 1 Finished Cooled No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Vas No Yes No Yes No Yes No Yes Heated Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value 1 Slab -On -Grade Edge Insulatio BED 1 26 ft Area 174 ft• Joist R-Value ____ Tile Wood 0 0 Carpet 1 2 Slab -On -Grade Edge Insulatio BATH 2 6 ft 60 ft' 1 0 0 3 Slab -On -Grade Edge Insulatio BED 2 26 ft 168 iN 0 0 1 4 Slab -On -Grade Edge Insulatio DINING ROOM 17 ft 456 W ___ 1 0 0 6/26/2020 11:37 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT S11MMARV r141=rWl IRT Iz=anIZT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio GREAT ROOM 14 ft 70 ft2 0 0 1 6 Slab -On -Grade Edge Insulatio NOOK 19 ft 88 ft2 ___ 1 0 0 _ 7SIab-On-Gr2de Edge Insulatio KITCHEN 1 ft 200 ft2 ____ 1 0 0 8SIab-On-Grade Edge Insulatio LAUNDRY 7ft 70 1? 1 0 0 9 Slab -On -Grade Edge Insulatio MASTER TOILET O ft 26 ft2 __ 1 0 0 10SIab-On-Grade Edge Insulatio MASTER BATH 23.5 It 144 ft2 1 0 0 11SIab-On-Grade Edge Insulatio WIC MASTER IN 1 ft 48 ft2 ____ 0 0 1 12SIab-On-Grade Edge Insulatio WIC MASTER EX Sit 48 R' ___ 0 0 1 13SIab-On-Grade Edge Insulatio MASTER SUITE 30 It 300 ft2 _—_ 0 0 1 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor, Tested Tested Insul. (dog) 1 Hip Composition shingles 1952 W 0 ft2 Medium N 0.9 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 160 1852 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type _ 1 Under Attic (Vented) BED 1 30 Blown 174 ft2 0.1 Wood 2 Under Attic (Vented) BATH 2 30 Blown 60 ft2 0.1 Wood 3 Under Attic (Vented) BED 2 30 Blown 168 ft2 0.1 Wood 4 Under Attic (Vented) DINING ROOM 30 Blown 456 ft2 0.1 Wood _ 5 Under Attic (Vented) GREAT ROOM 30 Blown 70 ft2 0.1 Wood 6 Under Attic (Vented) NOOK 30 Blown 88 ft2 0.1 Wood _ 7 Under Attic (Vented) KITCHEN 30 Blown 200 ft2 0.1 Wood _ 8 Under Attic (Vented) LAUNDRY 30 Blown 70 11:2 0.1 Wood _ 9 Under Attic (Vented) MASTER TOILET 30 Blown 26 ft2 0.1 Wood 10 Under Attic (Vented) MASTER BATH 30 Blown 144 ft2 0.1 Wood _ 11 Under Attic (Vented) WIC MASTER IN 30 Blown 48 ft2 0.1 Wood _ 12 Under Attic (Vented) WIC MASTER EX 30 Blown 48 ft2 0.1 Wood 13 Under Attic (Vented) MASTER SUITE 30 Blown 300 ft2 0.1 Wood 6I26I2020 11:37 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INIDI ITRI IMMARV rWl=rtlll ICT RFDnQT WALLS 11 Adjacent SPece nmf To MIMI Type Cavity Width Height Ft In Et W Are, Sheathing Framing A-VAI, rzrct� Solar Below _ 1 N=>E Exterior Concrete Block - Int Insul BED 1 6.5 12 0 8 0 96.0 V 0 0 0.5 0 2 E=>S Exterior Concrete Block - Int Insul BED 1 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 3 N=>E Exterior Concrete Block - Int Insul BATH 2 6.5 6 0 8 0 48.0 ft' 0 0 0.5 0 -4 N=>E Exterior Concrete Block - Int Insul BED 2 6.5 12 0 8 0 96.0 ft' 0 0 0.5 0 _ 5 W=>N Exterior Concrete Block - Int Insul BED 2 6.5 14 0 8 0 112.0 ft2 0 0 0.5 0 -6 E=>S Exterior Concrete Block - Int InsDINING ROO 6.5 17 0 8 0 136.0 ft2 0 0 0.5 0 -7 W=>N Exterior Concrete Block - Int InsGREAT ROO 6.5 14 0 6 0 112.0 ft' 0 0 0.5 0 _ 8 N=>E Exterior Concrete Block - Int Insul NOOK 6.5 8 0 6 0 64.0 ft' 0 0 D.5 0 _ 9 W=>N Exterior Concrete Block - Int Insul NOOK 6.5 10 0 8 0 80.0 ft' 0 0 0.5 0 _ 10 S=>W Exterior Concrete Block - Int InsdASTER BA 6.5 13 0 8. 0 104.0 ft' 0 0 0.5 0 _ 11 S=>W Exterior Concrete Block - Int InsWIC HASTE 6.5 8 0 8 0 64.0 ft' 0 0 0.5 0 92 S=>W Exterior Concrete Block - Int InsMASTER SUI 6.5 16 0 8 0 128.0 ft2 0 0 0.5 0 _ 13 W=>N Exterior Concrete Block - Int InsMASTER SUI 6.5 14 0 a 0 112.0 ft' 0 0 0.5 0 14 E=>S Garage Frame - Wood BED 1 11 20 8 160.0 ft' 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>S Wood BED 1 None .39 2.8 8 22.4 ft2 2 E=>S Insulated DINING ROO None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 90 degrees), Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E=>S 2 Vinyl Double (Tinted) Yes 0.33 0.25 N 15.0 ft2 1 R 6 in 1 ft 0 in None None 2 N=>E 3 Vinyl Double (Tinted) Yes 0.33 0.25 N 9.0 ft2 1 It 6 in 1 ft 0 in None None 3 N=>E 4 Vinyl Double (Tinted) Yes 0.33 0.25 N 15.0 ft2 1 It 6 in 1 ft 0 In None None _ 4 E=>S 6 Vinyl Double (Tinted) Yes 0.33 0.25 N 30.0 iN 7 R 0 in 1 ft 0 In None None _ 5 W=>N 7 Vinyl Double (Tinted) Yes 0.33 0.26 N 64.0 ft2 14 ft 6 In 1 ft 0 in None None 6 S=>W 10 Vinyl Double (Tnted) Yes 0.33 0.25 N 12.0 ft2 1 ft 6 in 1 ft 0 in None None 7 S=>W 12 Vinyl Double (Tinted) Yes 0.33 0.25 N 30.0 ft2 1 ft 6 in 1 ft 0 in None None 8 W=>N 13 Vlnyl Double (Tinted) Yes 0.33 0.25 N 30.0 ft2 1 ft 6 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 469 ft2 469 ft2 64 It 8 ft 1 6/26/2020 11:37 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHFCKI IST RFPOPT INFILTRATION # Scope Method SLA CFM 5C ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 2160.7 118.62 223.08 .1685 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 33.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER: 14 33 kBtu/nr 990 cfm 0.75 1 3ys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 60 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None R' DUCTS J -- Supply -- # Location R-Value Area -- Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 250 R' DINING ROO 1 ft' Default Leakage DINING RO (Default) (Default) 1 1 TEMPERATURES Progremable ]Thermosta[[t:]Y ((]] Heating [XI Jan [X� Feb [X) Mar Venting [ 1 Jan [ Feb [X) Mar [ jj CApr eiling Fans: ((]] ] �Xj Jun [X] Jul 4X] Aug t 1P Oct E I Apr [ May lXl lx]] Jun [[ ]) Jul [ 1 Aug l 1 Sep ov NovIrXr [Xi No Dee [ Dec c 6/26/2020 11:37 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CNFCKI IAT RGanGT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. Oft° Oft 0.3 BED Default(8 Ibs/sq.ft. R' It 0.3 BATH 2 Default(8 lbslsq.ft. ft' ft 0.3 BED 2 Default(8 lbs/sq.ft, ft' ft 0.3 DINING ROOM Default(8 Ibs/sq.ft. ft2 It 0.3 GREAT ROOM Default(8 lbs1sq.R. ft' ft 0.3 NOOK Default(8 lbs/sq.ft. it' R 0.3 KITCHEN Default(8lbs/sq.ft. ft' It 0.3 LAUNDRY Default(8 Ibs/sq.R, it, ft 0.3 MASTER TOILET Default(B Ibs/sq.ft. ft' ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft' It 0.3 WIC MASTER INT Default(8 lbs/sq.ft. fv It 0.3 WIC MASTER EXT Default(8 bs/s.ft, ft' It 0.3 MASTER SUITE 6126/2020 11:37 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FleRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 5.0 2. Single-family or multiple -family 2. Single-family b) Return duds R 6.0 c) AHU location DINING ROOM 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13, Cooling system: Capacity 33.0 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/Water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1852 d) Room unit/PTAC EER e) Other 14.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.330 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 205.0 8, Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA S. Floortype, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and Insulation: A. Exterior 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 9a. 0.0 9b. 9c. 10A1. 10A2. 6.5 14. Heating system: Capacity 33.8 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE 1) Other 8.26 15. Water heating system a) Electric resistance EF 0.95 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heal pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 1081. 11.0 10132. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home ha omplied with the Florida Building Code, Energy Conservation, through the above energy saving features which I e Installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be co p t� baseld o installed wde compliant features. Date: fi / 7 4i=1 / Z 4J Address of New Home: 8682 LONESOME PINE TRAIL City/FL Zip: FORT PIERCE. FL 6/2612020 11:37:30 AM EnergyGauge® USA 6.0.03 (Rev. 1) . FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421.4117 Fax 954-420-0064 Web. www.lindstromaircom Pro*eCt Information For: HOMECRETE Notes: BYERS RES Design Information Job: Date: 6-2020 By: LINDSTROM Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Outside db Inside db Design TD Daily range Relative humidity Moisture difference 90 75 15 M 50 61 OF OF OF % gr/lb Heating Summary Structure 20331 Btuh Ducts 3311 Btuh Central vent (58 cfm) 1793 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 25434 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area (ft') Volume (fP) Air changes/hour Equiv. AVF (cfm) Heatingg 1852 18521 038 117 Cool 1852 18521 0.20 62 Heating Equipment Summary Make CARRIER Trade Model CH14NA036 AHRI ref Efficiency 8.2 HSPF Heating input Heating output. 33800 Btuh @ 47'F Temperature rise 26 OF Actual air flow 1200 cfm Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Space thermostat Capacity balance point = 0 OF Backup: CARRIER 10 KW Input = 7 kW, Output = 24512 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 16317 Btuh Ducts 5454 Btuh Central vent (58 cfm) 961 Btuh Outside air Blower 0 Stuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 21596 Btuh Latent Cooling Equipment Load Sizing Structure 3779 Btuh Ducts 1589 Btuh Central vent (58 cfm) 2434 Btuh Outside air Equipment latent load 7802 Btuh Equipment Total Load (Sen+Lat) 29398 Btuh Req. total capacity at 0.76 SHR 2.4 ton Cooling Equipment Summary Make CARRIER Trade Cond CH14NA036 Coil FB4CNP036 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 14 SEER 25000 Btuh 8000 Btuh 33000 Btuh 1200 cfm 0.055 cfm/Btuh 0 in H2O 0.74 Calculations approved by ACCA to meet all requirements of Manual J 6th Ed. _ -Fi*- wrlghtaoR" 2020-Jun-26 11'40:57 Right-Swte9 Universal 2019 19.0 12 RSU08398 Page 1 ACC$" ..OJECTS ENERGY\A- MANUAL J\HOMECRETE - BYERS, rup Cale = MJ8 Front Door faces: N Right-M Worksheet Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone. 954-421-4117 Fax: 954420-0064 Web: www. Iindstromancom en-T Date: 6-2020 By: LINDSTROM 1 2 3 4 5 Roam name Exposed wall Room height Room dimensions Room area Entire House 182.5 it 100 ft 1852.0 W BEDROOM 2 26.0 ft 10.0 ft heelfcool 14.4 x 12.0 ft 172.8 ft- Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (BtulVfWF) (Btuhfft� or perimeter (ft) (B tun) or perimeter (ft) (Btuh) Heat I Cool Gross I N/P/S Heat Cod Gross N/P/S Heat Cool 6 11 W/ I�----GG 13A-6oc5 1D-h2om lD-h2om ID-h2cmd 13A-6ocs IC-h2om 10-h2om 13A-6ocs 1D-h2om 1D-h2om 0.111 0.870 0.870 0.870 0.111 0.870 0.870 0 111 0.870 0,870 n n n n a a a s s s 3.11 0.00 24.36 24.36 3.11 24.36 24,36 3.11 24.36 24.36 1.48 0.00 22.27 22.27 1.48 52.63 53.71 1.46 22.27 22.27 440 0 30 64 304 9 15 256 15 30 346 1 0 1 280 1 1 211 30 60 1075 0 731 1559 870 219 366 656 365 731 511 0 668 1426 413 474 806 311 334 668 0 0 0 0 96 0 0 112 15 0 0 0 0 0 96 0 0 97 15 0 0 0 0 0 298 0 0 301 3S5 0 0 0 0 0 142 0 0 143 334 0 ID-h2ob 1aA-6ocs 1D-h2om 0,650 0.111 0.870 a w w 0.00 3.11 24.36 0.00 1.48 53,31 0 296 12 29 254 1 0 789 292 0 376 640 0 0 0 0 0 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.36 53.71 30 3 731 1611 0 0 0 0 q I-D 12B-0bw 0.097 - 272 0.51 172 150 407 92 0 0 0 0 11DO 0.390 a 10.92 10,34 22 22 240 227 0 0 0 0 C 166-30ad 0,032 a 0.90 1.50 1852 1852 1659 2963 173 173 155 776 F 22A-tpm 1.180 a 33,04 0.00 1852 183 6030 0 173 26 B59 0 6 a) AED excursion 0 -79 Envelope loss/gain 16722 11519 1979 816 12 a) Infiltration 3609 1018 579 163 b) Room ventilation 0 0 0 0 13 Internal gainsOccupants ® 230 8 1380 1 230 Applianoes/other 2400 0 Subtotal (lines 6 to 13) 20331 16317 2658 1210 Less external load lass transer Redistribution 0 0 0 0 0 0 0 0 0 0 0 0 14 Subtotal 20331 16317 2566 1210 15 Duct loads 1 16% 33k Mill5454 16% 33°/e 417 404 Total mom load 23642 217-72 2975 1614 Air required (cfm) 1200 1200 151 89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ......... 2020-Jun-2611 40:57 Right -Suite® Universal 2019 19.0 12 RSU08398 Page 1 '���`...OJECTS ENERGY41- MANUAL J\HOMECRETE- BYERsrup Calc=MJ8 Front Doorlaces N ntire House Worksheet Job: e 6-2020 a..�tra.... Entire use By: NosTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 964421-4117 Fax 954d20-0064 Web: wwwtindstromaiccom 1 Room name BATH 2 BED 2 l 8.0 ft 25.0 ft 3 Room ghted 10.0 ft heat/cool 10.0 ft heaucod 4 Room dmenslons 6.0 x 10.0 B 12.0 x 14.0 ft 5 Room ales 80.0 ft' 16B.0 ft' Ty Construction U-value Or HTM ft A(1t`) Load Area number (BtuNftz°F) (Bu"ttal or perimeter (ft) (Btuh) or perimeter (ft) (Btu) Heat Cod Gross I NIPIS Heat Cool Gross N/PIS Heat Cool e 13A-G= 0.111 n all 1.48 0 0 0 0 112 112 348 185 T ID•h2om 0,870 n 0.00 0.00 0 0 a 0 0 0 0 0 FL---GCC ID412an 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 10412omd 0.870 n 24,38 22,27 0 0 0 0 0 0 0 0 11 VrJ 13A-60ca 0.111 a 3.11 1.48 48 39 121 58 95 61 252 120 ID-h2om 0.870 a 24.35 52.63 9 1 219 474 0 0 0 0 ID-h2om 0. 870 a 24.35 53.71 0 C 0 0 16 1 356 We `Rl 1D412M 0.111 s 4..11 1.48 0 0 0 0 0 0 0 0 1D-t2= 0.870 a 24.38 22.27 0 0 0 0 0 0 0 0 iD-h2om 0.650 a 24.36 20.00 0 0 0 0 0 0 0 0 III---.GGG b 0,111 s 000 0 0 0 0 0 0 0 0 1M 13A-5 cs 0.111 w 4..11 1.48 1.31 0 0 0 0 0 0 0 0 {L-OG ID-1ha ID-Mtom 0.870 w 24.38 53.31 0 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.3B S3.71 0 0 0 0 0 0 0 0 Ij �--D 128-OWi 0.097 - 2.72 0.61 0 0 0 0 0 0 0 0 11DO 0.39D a 10.92 10.34 0 0 0 0 0 0 0 0 C 168-30ad 0.032 a 0.90 1.60 60 60 54 98 168 168 151 269 F 22A{pm 1.180 a 3a04 0.00 60 8 198 0 188. 28 8% 0 6 c) AED excursion -21 -59 Envelope lossigain 592 606 1975 1301 12 a)) Infiltration 134 38 579 163 b) Room ventilation 0 0 0 0 13 Internal game: OCCAXAS a 230 0 0 1 230 ApplierceVother 0 0 Subtotal (lines 6 to 13) 726 644 2554 1694 Less extemar load o 0 0 0 Less transfer 0 D 0 0 RedisMbution 0 0 0 0 14 Subtotal 726 644 2654 1694 15 Duct loads 16% 330% 118 215 16% 33% 416 566 Total man load am 859 2970 2% Air required (cfm) IQ47 151 125 Calculations approved by ACCA to meet ail requirements of Manual J 8th Ed. wrlgh[so�tt- 2020-Jun-26 11:40:57 Right-SufteO Universal 2019 19.0.12 RSUOB398 ''��4`...OJECTS ENERGY\A- MANUAL JIHOMECRETE- BYERS.rup Calc -MJS Frond Door fW":N page 2 Right-J® Worksheet Job: ��«ri Entire House Date: 6-2020 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAE RD, POMPANO BEACH. FL 33069 Phone: 95442.14117 Fax: 954.420-0064 Web. www.lindsrramalrcom 1 Room name DINING ROOM GREAT ROOM 2 Exposad"ll 17.0 ft 16.0 a 3 Room height 10.0 ft heaVccol 10.0 It heat/cool 4 Room dtmerlslpne 18.0 x 18.0 It 17.0 x 17.0 ft 5 Roam area 324.0 ft' 289.0 W Ty CohsWction U-value Or HTM Area (" Load Area (ft') Load number (Bluh/It'-'F) (BtWftj or perimeter (ft) (Btuh) or perimeter (8) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/PIS Heat Cool 6 13A-Socs 0.111 n 3.11 1.48 0 0 0 0 138 72 224 106 ID-h2om 0,570 n 0.00 0.DO 0 0 0 0 0 0 0 0 1D-h2om o970 n 24.35 22.27 0 0 0 0 0 0 0 0 1D-h2omd 0.870 n 24.36 22.27 0 0 0 0 64 0 1559 1426 11 lql 13A-6ocs 0,111 a 3,11 1.48 0 0 0 0 0 0 0 0 1D-h2om 0970 a 24.36 52.63 0 0 0 0 0 0 0 0 1---GG 1D-h2om 0.870 a 24.36 53.71 0 0 0 0 0 0 0 0 1pJ 13A-6ocs 0.111 5 3.11 1.48 144 114 354 165 0 0 0 0 10-h2om 0,B70 s 24.36 22.27 0 0 0 0 0 0 0 0 1D-h2om 0.870 s 24.36 22.27 30 30 731 668 0 0 0 0 1D-h2ob 0.6m s 0.00 0.00 0 14 0 0 0 0 0 0 W, 13A-6ocs 0.111 w 3.11 1.48 0 0 0 0 0 0 0 0 10-h20m 0.870 w 24.36 53.31 0 0 0 0 0 0 0 0 L��G 10412M 0,870 w 24.36 53,71 0 0 0 0 0 0 0 0 ii-12B-Obw D 0.097 - 2.72 0.61 0 0 0 0 0 0 0 0 11DO 0.390 a 10,92 10.34 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 a 0.90 1.50 324 324 290 518 269 289 259 462 F 22A-orn 1.180 a 33.04 0.00 324 17 562 0 289 16 529 0 6 c) AED excursion -90 -176 Envelope loss/gain 1937 1265 2570 1819 12 a) Infiltration 401 113 379 107 b) Roan ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 2 460 Applianceslother 0 300 Subtotal (lines 6to 13) 2338 1378 2949 2686 Less external load o o p D Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2338 1378 2949 2686 151 Duct loads 16% 33%l 381 461 16% 33% 480 898 Total room load 1 2719 1839 3429 3583 Air required (cfm) 138 101 174 197 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ �{+ wrlg�aaoTc- 2020-Ju0-26 11'.40.57 Right-Sulte® Universal 2019 19.0 12 RSU06398 Page 3 .4C�`/s .., OJECTS ENERGY\A- MANUAL J\HOMECR ETE -BYERS, rup Cato - MJB Front Doorlaces: N Entire House sheet gate µkw Entire House Date: 6.2020 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH. FL 33089 Phone: 954-4214117 Fax 954-420.0064 Web: wwwJinostromaiccom - Room rare PANTRY KITCHEN 2 Exposed wall 19.0 ft 0 ft 3 Room height 10.0 ft heatl000l 10.0 It heaVcool 4 Raarn dimensions 11.0 x 4.0 ft 10.0 x 1S0 ft 5 Room area 44Ili ' 150,0 IF Ty ction U-value Or HTM Am (ftxi Load Area ((V) Load (Stulvft''F) (Btulvftg or perimeter (ft) (Btuh) or Perimeter (ft) (Stub) Heal Cool Gras N/P/S Heat cool Gross NIPIS Heat Cool 6 F13A.6xs 0111 n 3,11 1.48 80 80 249 118 0 0 0 0 �s 0870 n 0,00 0.00 0 1 0 0 0 0 0 0 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 d 0870 n 24.36 22,27 0 0 0 0 0 1 0 0 11 ' 0.111 a 3.11 148 64 e4 199 94 0 0 0 0 ��-(G` 0870 a 24.36 52.63 0 0 0 0 D 0 0 0 0870 a 24.36 53.71 0 0 0 D 0 0 0 0 13A.6ocs 0.111 s 3.11 1.48 0 0 0 0 0 0 0 0 ID-h2om 0870 s 24.35 22.27 0 0 0 0 0 0 0 0 1D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 1D-h2ob 0650 s 0.00 0.00 0 0 0 0 0 0 0 0 13A-6 c 0.111 w 3.11 1,48 0 0 0 0 0 0 0 0 1D-h2arn D. 870 w 24.36 53.31 0 0 0 0 D 0 0 0 1D-h2an 0870 w 24.36 53.71 0 0 0 0 0 0 0 0 R 0 12Mbv 0,097 - 2.72 0.61 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 --- C 16B.30ad 0.032 a 0.90 1.60 44 44 39 70 150 150 134 240 F 22A-tpm 1. 180 a 33.04 0.00 44 19 620 0 150 0 0 0 6 c)AED excursion -24 -125 Envelope loss/gain ills 259 134 115 12 a) Infiltration 401 113 0 0 b) Room ventilation 0 0 a 0 13 Internal gains, Occupants C 230 0 0 0 0 APWienoeslother 0 1800 Subtotal (lines B tC 13) 1516 372 134 1915 Less external lead 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1516 372 134 1915 1151 Duct loads 16% 33% 247 124 16% 33% 22 640 Total noon load 1763 496 156 25M Air required (cfm) 89 27 8 141 Calculations awroved by ACCA to meet all reauirements of Manual J 8th Ed wRigrlphtsoft- 2020-Jun-26 11.40:57 At& MANUAL Universal 2019 S. rup2 Cal= =RSU0M96 page 4 ...OJEC7S ENERGVw-MANUAL J\HOMECRETE-eVERS.rup CaIc=MJB Fmm Door laces: N En ire Worksheet Job: H »� Enure House Date: 6.2020 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAS RD, POMPANO BEACH, FL 33069 Phone: 954-4214117 Fax 954420-0064 Weo: wwwJindstromair.com 1 Room name LAUNDRY MASTER TOILET 2 Exposed wall 7.0 ft 40 R 3 Room height 10.0 ft heat/cool loo n hea/cool 4 Room dimensions 10.0 x 7.0 fi 4.0 x 6.5 ft 5 Room area 700 W 26.0 n' Ty Construction U-value Or HTM Area (ft� Load Area (flx) Load number (BtuNftk*F) (Btuh/fY) or penmeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gloss I N/P/S Heat Cod Gross N/P/S Heat Cool 6 o 0.111 n 3.11 0 0 0 0 0 0 0 0 ID-h2 1D-h2am 0.870 n 0 000.00 0 0 0 0 0 0 0 0 ID-h2an 0.87C n 24.36 22.27 2 27 0 0 0 0 0 0 0 0 13A.6omc 0,111 a 24. 21 0 0 0 0 0 0 0 0 11 �pl 13A-Bocs 0. 111 a 311 11 48 163 0 0 0 0 0 0 0 0 1D-h2om 0.870 a 24.36 52.63 0 0 0 0 0 0 0 0 0. a 2436 5371 0 0 0 0 0 0 0 0 laA-6cm 13A�om 111 0.111 s 3.11 0 0 0 0 0 0 0 10.112an 0.870 s 24.36 227 22 27 0 C 0 0 0 0 0 0 0 1D-h2om 0.870 s 2436 2227 0 0 0 0 0 0 0 0 ID-h2ob 0.650 s 0,00 0.00 0 C 0 0 0 0 0 0 +N 13A-G c 0.111 w 3,11 1,48 0 0 0 0 0 0 0 0 1D-h2an 0,870 w 24.36 53.31 0 0 0 0 0 0 0 0 L��r 1D-12o1n 0.870 w 24.36 53.71 0 0 0 0 0 0 0 0 12B-Obw 0.097 - 272 0.61 56 34 92 21 32 32 87 20 D 11DO 0.390 a 10.92 10.34 22 22 240 227 0 0 0 0 C 16B-30ad 0,032 a 0.90 1.60 70 70 63 112 26 26 23 42 F 22A-tpm 1. 180 a 3304 0.00 70 7 231 0 28 4 132 0 6 c) AED excursion 41 4 Envelope loswgain 627 320 242 57 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internet gains. Occupants 230 0 0 0 0 Applianceslother 300 0 Subtotal (lines 6 to 13) 627 620 242 57 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 627 620 242 57 15 Duct loads 16% 33% 102 207 16% 33% 39 19 Total room load 729 827 282 77 Air required (cfm) 37 46 14 4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .+�. -HW wrkjnasore^ 2020-Jun-2611:40:57 --•�- Rlghl-SulteS Univerial 201919.0. 12 RSUG8398 Page 5 ...OJECTS ENERGYW- MANUAL AHOMECRETE -BYERS rup Calc = MJ8 Front Door faces: N ��»� Right House ksheet Job: House Date: 6.2020 Lindstrom Air Conditioning By: LINDSTROM 3581 W MC NAB RD, POMPANO BEACH, FL 33069 Phone: 954421-4117 Fax: 954-420-0054 Webwww.linoatrom air. corn 1 MASTER BATH WIC MASTER INT 2ll flcrimensions 23.5 R 0 f t 3 10.0 ft heaUcool 10.0 ft heaticool 4 12.0 x 12.0 k 8.0 x 6.0 n 5 144.0 W 48.0 W Ty Construction U-value Or HTM Aiwa (tt� Load Area (W) Load number (BlutvfN--°F) stuwftx or perimeter (ft) (Btuh) or perimeter (ft) (Btuh ) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 1QJ 13A-6ocs 0.111 n 3,11 1AS 0 0 0 0 0 0 0 0 1D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 ���-----GGG 1D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 1D-h2omd 0.870 n 24.36 2227 0 0 0 0 0 0 0 0 11 13A-600s 0.111 a 3,11 1.48 0 0 0 0 0 0 0 0 1D-h2om 0,870 a 24.36 52.63 0 0 0 0 0 0 0 0 1 D-h2am 0,870 a 24.36 5371 0 0 0 0 0 0 0 0 15/ 13A-Bocs 0.111 s 3.11 0 0 0 0 0 0 0 0 1 D-h2o n 0,870 s 24,36 2 27 2227 0 0 0 0 0 0 0 0 1 D-h2om 0.650 s 24.38 20.00 0 0 0 0 0 0 0 0 t 0.111 s 0 0 0 0 0 0 0 aA-6ob 13A8ocs 0.111 t w 4..11 311 lA8 112 92 292 6 0 0 0 0 1D-h2om 0.870 w 24.36 3 31 53.31 12 1 292 640 840 0 0 0 0 1 D-h2om 0.870 w 24.36 53.71 0 0 0 0 0 0 0 0 q �-D 12"low 0.097 - 2,72 0,61 84 84 228 $1 0 0 0 0 11D0 0.390 a 10,92 10.34 0 0 0 0 0 0 0 0 C 16B-30ad 0,032 a D90 1,60 144 144 129 230 48 48 43 77 F 22A-tpm 1.180 a 33.04 0,00 144 24 T76 0 48 0 0 0 6 C) AED excursion 1 230 -5 Envelope loss/gain 1712 1287 43 72 12 a) Infiltration 290 82 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants Q 230 0 0 0 0 Applian0es/other 0 0 Subtotal (lines 6 to 13) 1 1 2002 1369 43 72 Less external load 0 0 0 0 Less hater 0 0 0 0 Recistribubw 0 0 0 0 14 Subtotal 2002 1369 43 72 151 Duct loacis 16% 33% 326 458 i6% 33% 7 24 Total room Imtl 2327 1626 50 96 Air required (Cfm) 118 101 3 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. y -•'i•- taofe' 2020-Jun-2611:40:57 wregli RAhHOUniversal 2019 19,0.12 RSU 08398 Page 6 �� _.OJ ECTS ENER GYIA'MAN UAL L JIHOMECRETE - BYERS.rup Calc = MJB Front Door faces: N Right -A) ®Worksheet Job: E w ntrre House Date: 6-2020 Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 964421-4117 Fax 954420.0084 Web: www.l,ndstrome[r.com WIC MASTER Exr MASTER SUITE so ft 30.0 ft 7Rm 10.0 ft heaV000l 10.0 ft heal/Cool ions 8.0 x 6.0 H 15.0 x 20.5 ft 48.0 ft- 308,2 fH Ty Construction U-value Or HTM Area (ft� Load Area (fts) Load number (Stuh/ft"F) (BtutdfV) or perimeter (ft) (Btuh) or perimeter (ft) (Stuh) Heat I Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cad 6 Vb13A-60C8 0,111 n 3.11 1.48 0 0 0 0 112 82 255 121 1D-h2w 0.970 n 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 n 24.36 22.27 0 0 0 0 30 0 731 e68 1D-h2omd 0.87D n 24,36 22.27 0 0 0 0 0 0 0 0 11 1p/ 13A11oc5 o111 a 3.11 1.48 0 0 0 0 0 0 0 0 1D-h2om 0.870 a 24.36 52.63 0 C 0 0 0 0 0 0 10-h2om 0.870 a 24.36 53.71 0 0 0 0 0 0 0 0 13A-6as 0.111 s 3.11 1.48 0 0 0 D 0 0 0 0 10-h2om 0.870 s 2438 22.27 0 0 0 0 0 0 0 0 1D-h2om 0,870 s 2436 22.27 0 0 0 0 0 0 0 0 1D-h2ob 0,650 s 0,00 0.00 0 0 0 0 0 0 0 0 lyY 13A-6ocs 0.111 w 3.11 1.48 64 64 199 94 128 98 305 145 ID-h2om 0.870 w 24.36 53,31 0 0 0 0 0 0 0 0 I{_G.G ID-h2om 0.870 w 24.36 5371 0 0 0 0 30 1 731 1611 li-128-OM 0.097 - 272 0.61 0 0 0 0 0 0 0 0 D 1100 0.390 a 1o92 10.34 0 0 0 0 0 0 0 0 C 16"Gad 0o32 a 0.90 1,60 48 48 43 77 308 308 276 493 F 22A4pm 1.180 a 33.04 0,00 48 a 284 0 308 30 991 0 6 c) AEG excursion 1 -14 1 407 Envelope loss/gain 506 158 3288 3445 12 a) Infiltration 178 50 668 188 b) Roan ventilation 0 0 0 0 13 Intemai gains'. Occupants 0 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 684 208 3957 4093 Less external Iced 0 0 0 0 Less transfea 0 0 0 0 Redistributlort 0 0 0 0 14 Subtotal 884 ZDB 3957 4093 15 Duct 1px5 1 16% 33%1 ill 70 16% 33% 644 1368 Total room Iced 796 277 4601 5462 Air required (cfm) 40 15 234 .1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wregh4:esof�' 2020.Jun-Jun 11,40.57 .1C�A- ---- -^ Right-SuaeV Universal 2019 19.0.12 RSU083W Page 7 .,.OJECTS ENERGYIA- MANUAL JIHOMECRETE- BYERS.rup Calc-MJ8 Front Door faces. N