HomeMy WebLinkAboutTruss Layout - 06-23-20 20-0633=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY. o,
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Sp4n or less
60 degrees
or less
Tag line �� 112 span
approx
Tag line �ipprox 213 to —�
rz Df span.
REFER TO BCSI
REFER TO BCSI
Truss must be set this way IT crane is used.
Truss must b e set this way d crane is used.
I
Truss is an example, your truss may not match.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
Insist vane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. 1\t
•
•
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
h WARNING !N
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
SEAT PLATES BY CHAMBERS TRUSS
REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
TRUSS
HANGERID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
JCARRIEDCARRYING
GR
THD26-2
1 -
0D
-16D
`Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1 /2"
Hatch Legend
CEILING
AT8'-8"
INDICATES
VOLUME
CEILING
LOAD
BEARING
AT 8'-0"
LOAD
BEARING
AT 10'-8"
Do not stand on
trusses
until they are braced per BCSI
&
properly nailed to
straps
and
hangers !!
&ARRANGE
WITH
CRANE
OPERATOR
IN ADVANCE
FOR
A
SPREADER
BAR
OF 28'
- 35'
IN
LENGTH!!
a
HIV CMRIER LOCATED AS OOAI INSIONED ON LAYOVT
I
i
g '
CORNDERJADKS
ME NOT aEV a i
i SEE ENGINEERING BTMDMD •*
O
I�
I
ii
1 _I
i
21'OC ➢MuJACI(- i
CORNER 5
ONLY 20" 1. 1411 i
I
CORNER DETAIL
i m ---oveiHANNOT SHOV" FOR CI iTY
'
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 8'-0"
END DETAIL: COFFER
2-08-00
1-04-00
12
5r-
PLUMB CUT END
12
2X4 TOP CHORD
5r—
WALL HEIGHT 8'-0"
END DETAIL: VAULT
4-01—
12 2.5
8-00
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT VARIES
ENC DETAIL: TYPICAL
1
12
5 r—
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The undersigned acknowledges and agrees:
I 1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for
determining successful fabrication of the trusses. i
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the I
Undersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss i
shall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
After 10 days of delivery remedy will be according to Florida statute 558,
4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has I
the sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
be responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has
to redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is;
responsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour;
tee for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
�nvoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of:
delivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss!
reasonable attorneys fee for Collections in event of payment not timely made. 1-1/2 °h per month service charge will be I.
added for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein. j
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
payment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
undersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the
recipient.
, 10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
herein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
! 11. Design responsibilities are per liNational Standard And Recommended Guidelines On Responsibilities For
Construction Using Metal Plate Connected Wood Trusses ANSIITPIWTCA 4 - 2002m
12. Warranty is per Chambers Truss Warranty attached.
, I
DATED
SIGNED
FOR TITLE
A spreader bar may be required per "BCSI" to prevent Injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
' ® i
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage. I
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 I
can err Avenue j
Fort Pierce, Florida 34982-6423
800.551.5932
Fort Pierce 772-465.2012 Fax 772-465-8711
Vero Beach 772-569.2012 Stuart 772-286.3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
QREmwo ORLIEMD
O REVIEWED AS NOTED O REVISE AND RESUBMIT
A'1`7HITECT
rli 1T81 VERSION YT43T—
LOADING/OESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 16N.6.1
i
DESIGN CRITERIA
County ST. LUCIE
Building Department ST. LUCIE COUNTY
Wind Design Criteria ASCE 2010 j
Wind Design Method MWFRS(Directionai)/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
j Loading in PSF Roof R.D.L. Floor -
Top Chord Live 20 0
Top Chord Dead 7 4.2 0 i
Bottom Chord Live -10-Non Conccurent 0
Bottom Chord Dead 10 3 0 j
Total Load 47 7.2 0
Duration Factor 1.25 0 -
I Wind Speed 160mph
i
Top Chord C.B. Sheathing by builder
Bottom Chord C.B. Sheathing by builder
Highest Mean Height 15'-6"
Building Type Enclosed
Building Category 11: Non Restrictive i
Exposure Category C>Open Terrain with scattered obstructions
Miles from Ocean 5 i
Conforms to Florida Building Code 2017
I R.D.L.=Restraining Dead Load C.8 =Continuous Bracing
i I
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 76800
SCALE: 1 /4" = V-0"
145 total trusses, 47 unique designs
Designer: RLC Reviewed by: RLC
Date: 06/15/20
FOR
HOMECRETE HOMES INC.
DESCRIPTION:
8682 LONESOME/ BYERS
Page 1 of 1 CUSTOMER INITIALS EACH PAGE
76800